Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 41
Filtrar
Más filtros










Intervalo de año de publicación
1.
Opt Lett ; 48(12): 3123-3126, 2023 Jun 15.
Artículo en Inglés | MEDLINE | ID: mdl-37319042

RESUMEN

Devices based on the lossy mode resonance (LMR) effect have found numerous sensing applications. Herein, the enhancement of the sensing properties by the introduction of an intermediate layer between the substrate and the LMR-supporting film is discussed. Experimental results for a silicon oxide (SiO2) layer of tuned thickness between a glass slide substrate and a thin film of titanium oxide (TiO2) prove the possibility of significantly increasing the LMR depth and the figure of merit (FoM) for refractive index sensing applications, which is supported by a numerical analysis using the plane wave method for a one-dimensional multilayer waveguide. The application of the intermediate layer allows the introduction of a new, to the best of our knowledge, degree of freedom into the design of LMR-based sensors, resulting in improved performance for demanding fields such as chemical sensing or biosensing.


Asunto(s)
Técnicas Biosensibles , Refractometría , Dióxido de Silicio
2.
Analyst ; 147(23): 5477-5485, 2022 Nov 21.
Artículo en Inglés | MEDLINE | ID: mdl-36321954

RESUMEN

Lossy mode resonance (LMR)-based optical sensors change their wavelength upon contact with substances or gases. This allows developing applications to detect the refractive index of the surrounding medium and even the thickness of the biolayers deposited on the waveguide. In the same way, when acoustic sensors are in contact with a liquid, it is possible to determine parameters, especially mechanical ones such as shape of the particle or molecule, mass load, elastic constants and viscosity of the liquid. This work reports the development of a system that combines LMR with surface acoustic wave (SAW) technologies to characterize a liquid in terms of its refractive index and viscosity simultaneously. Conveniently prepared glucose solutions are used for sensor calibration. The refractive index of the solutions ranges from 1.33 to 1.41 and its viscosity ranges from 1.005 mPa·s to 9 mPa·s, respectively. A sensitivity of 332 nm per RIU has been achieved with the optical sensor while the acoustic sensor has shown a sensitivity of -1.5 dB/(mPa·s). This new combinational concept could be expanded to the development of more demanding applications such as chemical sensors or biosensors.

3.
Biosensors (Basel) ; 12(6)2022 Jun 10.
Artículo en Inglés | MEDLINE | ID: mdl-35735551

RESUMEN

The development of resonance phenomena-based optical biosensors has gained relevance in recent years due to the excellent optical fiber properties and progress in the research on materials and techniques that allow resonance generation. However, for lossy mode resonance (LMR)-based sensors, the optical fiber presents disadvantages, such as the need for splicing the sensor head and the complex polarization control. To avoid these issues, planar waveguides such as coverslips are easier to handle, cost-effective, and more robust structures. In this work, a microfluidic LMR-based planar waveguide platform was proposed, and its use for biosensing applications was evaluated by detecting anti-immunoglobulin G (anti-IgG). In order to generate the wavelength resonance, the sensor surface was coated with a titanium dioxide (TiO2) thin-film. IgG antibodies were immobilized by covalent binding, and the detection assay was carried out by injecting anti-IgG in PBS buffer solutions from 5 to 20 µg/mL. The LMR wavelength shifted to higher values when increasing the analyte concentration, which means that the proposed system was able to detect the IgG/anti-IgG binding. The calibration curve was built from the experimental data obtained in three repetitions of the assay. In this way, a prototype of an LMR-based biosensing microfluidic platform developed on planar substrates was obtained for the first time.


Asunto(s)
Técnicas Biosensibles , Microfluídica , Bioensayo , Inmunoglobulina G , Fibras Ópticas
4.
Phys Chem Chem Phys ; 24(16): 9236-9246, 2022 Apr 20.
Artículo en Inglés | MEDLINE | ID: mdl-35388844

RESUMEN

The combination of a reducible transition metal oxide and a noble metal such as Pt often leads to active low-temperature catalysts for the preferential oxidation of CO in excess H2 gas (PROX reaction). While CO oxidation has been investigated for such systems in model studies, the added influence of hydrogen gas, representative of PROX, remains less explored. Herein, we use ambient pressure scanning tunneling microscopy and ambient pressure X-ray photoelectron spectroscopy on a CoOx/Pt(111) planar model catalyst to analyze the active phase and the adsorbed species at the CoOx/Pt(111) interface under atmospheres of CO and O2 with a varying partial pressure of H2 gas. By following the evolution of the Co oxidation state as the catalyst is brought to a reaction temperature of above 150 °C, we determine that the active state is characterized by the transformation from planar CoO with Co in the 2+ state to a mixed Co2+/Co3+ phase at the temperature where CO2 production is first observed. Furthermore, our spectroscopy observations of the surface species suggest a reaction pathway for CO oxidation, proceeding from CO exclusively adsorbed on Co2+ sites reacting with the lattice O from the oxide. Under steady state CO oxidation conditions (CO/O2), the mixed oxide phase is replenished from oxygen incorporating into cobalt oxide nanoislands. In CO/O2/H2, however, the onset of the active Co2+/Co3+ phase formation is surprisingly sensitive to the H2 pressure, which we explain by the formation of several possible hydroxylated intermediate phases that expose both Co2+ and Co3+. This variation, however, has no influence on the temperature where CO oxidation is observed. Our study points to the general importance of a dynamic reducibility window of cobalt oxide, which is influenced by hydroxylation, and the bonding strength of CO to the reduced oxide phase as important parameters for the activity of the system.

5.
Sensors (Basel) ; 21(12)2021 Jun 12.
Artículo en Inglés | MEDLINE | ID: mdl-34204709

RESUMEN

A fiber Bragg grating patterned on a SnO2 thin film deposited on the flat surface of a D-shaped polished optical fiber is studied in this work. The fabrication parameters of this structure were optimized to achieve a trade-off among reflected power, full width half maximum (FWHM), sensitivity to the surrounding refractive index (SRI), and figure of merit (FOM). In the first place, the influence of the thin film thickness, the cladding thickness between the core and the flat surface of the D-shaped fiber (neck), and the length of the D-shaped zone over the reflected power and the FWHM were assessed. Reflected peak powers in the range from -2 dB to -10 dB can be easily achieved with FWHM below 100 pm. In the second place, the sensitivity to the SRI, the FWHM, and the FOM were analyzed for variations of the SRI in the 1.33-1.4 range, the neck, and the thin-film thickness. The best sensitivities theoretically achieved for this device are next to 40 nm/RIU, while the best FOM has a value of 114 RIU-1.

6.
Sci Rep ; 11(1): 13228, 2021 Jun 24.
Artículo en Inglés | MEDLINE | ID: mdl-34168261

RESUMEN

Multi-parameter detection is key in the domain of sensors. Here it is demonstrated that an indium tin oxide (ITO) nanocoating can be used to generate multiple lossy mode resonances (LMRs) in the optical spectrum. To achieve this, a nanocoating with a gradient in thickness is generated on the surface of a planar waveguide, permitting broadening of the LMR because the position of an LMR in the optical spectrum is directly related to the nanocoating thickness. The nanocoating with a gradient in thickness contributes multiple LMRs, each one centred at a different wavelength. With a further etching or deposition using a mask, a pattern of deposited and non-deposited regions can be created, resulting in isolation of the LMRs by preventing LMR overlap. This enables tracking of each central wavelength separately, which can be tuned through control of the gradient or nanocoating pattern. The array of LMR-based sensors is a photonics analogue to the interdigital concept in electronics, enabling multiple resonances to be used for multiparameter sensing.

7.
Sci Rep ; 11(1): 11266, 2021 May 28.
Artículo en Inglés | MEDLINE | ID: mdl-34050199

RESUMEN

With the goal of ultimate control over the light propagation, photonic crystals currently represent the primary building blocks for novel nanophotonic devices. Bloch surface waves (BSWs) in periodic dielectric multilayer structures with a surface defect is a well-known phenomenon, which implies new opportunities for controlling the light propagation and has many applications in the physical and biological science. However, most of the reported structures based on BSWs require depositing a large number of alternating layers or exploiting a large refractive index (RI) contrast between the materials constituting the multilayer structure, thereby increasing the complexity and costs of manufacturing. The combination of fiber-optic-based platforms with nanotechnology is opening the opportunity for the development of high-performance photonic devices that enhance the light-matter interaction in a strong way compared to other optical platforms. Here, we report a BSW-supporting platform that uses geometrically modified commercial optical fibers such as D-shaped optical fibers, where a few-layer structure is deposited on its flat surface using metal oxides with a moderate difference in RI. In this novel fiber optic platform, BSWs are excited through the evanescent field of the core-guided fundamental mode, which indicates that the structure proposed here can be used as a sensing probe, along with other intrinsic properties of fiber optic sensors, as lightness, multiplexing capacity and easiness of integration in an optical network. As a demonstration, fiber optic BSW excitation is shown to be suitable for measuring RI variations. The designed structure is easy to manufacture and could be adapted to a wide range of applications in the fields of telecommunications, environment, health, and material characterization.

8.
Sci Rep ; 11(1): 3669, 2021 Feb 11.
Artículo en Inglés | MEDLINE | ID: mdl-33574474

RESUMEN

The incidence of light on the edge of a glass coverslip for a microscope slide, deposited with a thin film on both faces, permits exciting two resonances in each polarisation state of the input light, TE and TM. This dually nanocoated waveguide can be used for detecting simultaneously two different parameters on the basis of a further deposition of suitable materials on each face. As an example, the possibility of detecting temperature and humidity by using polydimethylsiloxane and agarose coatings, respectively, was demonstrated, which opens the path for the development of other dual-parameter sensors, and for even more parameters in cases in which each face of the coverslip is patterned. Moreover, the device was optimised in order to position two resonances in the near infrared (NIR) and two resonances in the visible region, with sensitivities of 0.34 nm/°C and 0.23 nm/%RH in the visible region and 1.16 nm/°C and 0.34 nm/%RH in the NIR, respectively, demonstrating the possibility of using the device in both spectral ranges and opening the path for the development of sensors based on multiple resonances, each one related to a different parameter to be detected.

9.
Opt Lett ; 45(17): 4738-4741, 2020 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-32870845

RESUMEN

The full width at half maximum (FWHM) of lossy mode resonances (LMRs) in the optical spectrum depends on the homogeneity of the thin film deposited. In this Letter, a method for improving the FWHM is applied for an LMR generated by a D-shaped optical fiber in reflection configuration. For this purpose, three samples with different attenuation were deposited with DC sputtering thin films of SnO2-x, and a further controlled immersion of the samples in water was performed. A laser-cleaner method was used to improve the FWHM characteristics of one of the samples from 106 to 53 nm. This improvement can be applied to thin-film-based sensors where there is a problem with the inhomogeneity of the coating thickness. Moreover, with this technique, it was proved that a coated length of just 3-4 mm permits the generation of an LMR, with implications for the miniaturization of the final device.

10.
Opt Lett ; 45(9): 2547-2550, 2020 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-32356813

RESUMEN

Bloch surface wave (BSW) platforms are particularly interesting for light confinement and surface sensitivity, as an alternative to the metal-based surface plasmon polaritons (SPP). However, most of the reported BSW platforms require depositing a large number of alternating dielectric layers to realize the excitation of the surface waves. In this Letter, we demonstrate an experimentally feasible D-shaped photonic crystal fiber (PCF) platform consisting of only a single dielectric layer on its flat surface, which can sustain Bloch waves at the boundary between the dielectric layer and the PCF cladding. The presence of the dielectric layer modifies the local effective refractive index, enabling a direct manipulation of the BSWs. In addition, the D-shaped structure provides direct contact with the external medium for sensing applications with an ultrahigh sensing figure of merit ($2451\;{{\rm RIU}^{ - 1}}$2451RIU-1) and has the potential to be used over a wide range of analyte refractive indices.

11.
Opt Express ; 28(1): 288-301, 2020 Jan 06.
Artículo en Inglés | MEDLINE | ID: mdl-32118958

RESUMEN

The generation of lossy mode resonances (LMRs) with a setup based on lateral incidence of light in coverslips is a simple platform that can be used for sensing. Here the versatility of this platform is proved by studying the deposition of different coating materials. The devices were characterized with both SEM and AFM microscopy, as well as ellipsometry, which allowed obtaining the main parameters of the coatings (thickness, refractive index and extinction coefficient) and relating them with the different sensitivities to refractive index attained with each material. In this way it was possible to confirm and complete the basic rules observed with lossy mode resonance based optical fiber sensors towards the design of simpler and more compact applications in domains such as chemical sensors or biosensors.

12.
Sci Rep ; 10(1): 4507, 2020 Mar 06.
Artículo en Inglés | MEDLINE | ID: mdl-32144335

RESUMEN

An amendment to this paper has been published and can be accessed via a link at the top of the paper.

13.
Small ; 15(40): e1902817, 2019 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-31433561

RESUMEN

A deep comprehension of the local anodic oxidation process in 2D materials is achieved thanks to an extensive experimental and theoretical study of this phenomenon in graphene. This requires to arrange a novel instrumental device capable to generate separated regions of monolayer graphene oxide (GO) over graphene, with any desired size, from micrometers to unprecedented mm2 , in minutes, a milestone in GO monolayer production. GO regions are manufactured by overlapping lots of individual oxide spots of thousands µm2 area. The high reproducibility and circular size of the spots allows not only an exhaustive experimental characterization inside, but also establishing an original model for oxide expansion which, from classical first principles, overcomes the traditional paradigm of the water bridge, and is applicable to any 2D-material. This tool predicts the oxidation behavior with voltage and exposure time, as well as the expected electrical current along the process. The hitherto unreported transient current is measured during oxidation, gaining insight on its components, electrochemical and transport. Just combining electrical measurements and optical imaging estimating carrier mobility and degree of oxidation is possible. X-ray photoelectron spectroscopy reveals a graphene oxidation about 30%, somewhat lower to that obtained by Hummers' method.

14.
Sci Rep ; 9(1): 8882, 2019 Jun 20.
Artículo en Inglés | MEDLINE | ID: mdl-31222069

RESUMEN

The deposition of an indium oxide (In2O3) thin film on conventional planar waveguides (a coverslip and a glass slide) allows generating lossy mode resonances (LMR) by lateral incidence of light on the waveguide and by registering the optical spectrum in a spectrometer. This novel sensing system becomes an alternative to optical fibre, the substrate where LMR-based sensors have been developed so far, since it is easier to handle and more robust. An additional advantage is that cost effective waveguides, such as slides or coverslips, can be used in a platform that resembles surface plasmon resonance-based sensors in the Kretschmann configuration but without the need for a coupling prism and with the advantage of being able to generate TE and TM LMR resonances with metallic oxide or polymer thin films. The results are corroborated with simulations, which provide in-depth understanding of the phenomena involved in the sensing system. As a proof-of-concept for the optical platform, two refractometers were developed, one with low sensitivity and for a wide range of refractive indices, and the other with higher sensitivity but for a narrower refractive index range. The sensors presented here open up the path for the development of LMR-based chemical sensors, environmental sensors, biosensors, or even the generation of other optical phenomena with the deposition of multilayer structures, gratings or nanostructures, which is much easier in a planar waveguide than in an optical fibre.

15.
Gac. sanit. (Barc., Ed. impr.) ; 33(3): 242-248, mayo-jun. 2019. tab, graf
Artículo en Español | IBECS | ID: ibc-183743

RESUMEN

Objetivo: Valorar diferencias entre necesidad e implementación de prácticas seguras recomendadas para la seguridad del paciente y utilidad del uso de señales de tráfico para promover su implementación. Método: El estudio constó de dos fases: 1) revisión de recomendaciones sobre prácticas seguras de diferentes organizaciones y 2) encuesta a una muestra de oportunidad de profesionales del ámbito asistencial, organizativo y académico de la seguridad del paciente de España y Latinoamérica para evaluar necesidad y la implementación percibida de las prácticas seguras y la utilidad de las señales para tal fin. Resultados: Se recibieron 365 cuestionarios. Todas las prácticas seguras identificadas fueron valoradas como necesarias (media y límite inferior del intervalo de confianza por encima de 3 sobre 5 puntos). Sin embargo, la implementación se valoró como insuficiente en seis de ellas: escritura ilegible, conciliación de medicación, estandarización de comunicación, sistemas de alerta rápida, aplicación de procedimientos por profesionales o equipos entrenados, y cumplimiento de voluntades del paciente al final de la vida. Mejorar cumplimiento de la higiene de manos, aplicación de precauciones de barrera, asegurar la identificación correcta de los pacientes y utilizar listados de verificación fueron las cuatro prácticas en las que más del 75% de los encuestados encuentran mayor grado de consenso sobre la utilidad de las señales de tráfico para mejorar su implementación. Conclusiones: Las diferencias entre necesidad percibida e implementación real de las prácticas seguras consideradas indican áreas de mejora. El lenguaje común de las señales de tráfico es un instrumento sencillo para mejorar su cumplimiento


Objective: To evaluate differences between the need and degree of implementation of safe practices recommended for patient safety and to check the usefulness of traffic sign iconicity to promote their implementation. Method: The study was developed in two stages: 1) review of safe practices recommended by different organizations and 2) a survey to assess the perceptions for the need and implementation of them and the usefulness of signs to improve their implementation. The sample consisted of professionals from Spain and Latin America working in healthcare settings and in the academic field related to patient safety. Results: 365 questionnaires were collected. All safe practices included were considered necessary (mean and lower limit of confidence interval over 3 out of 5 points). However, in six of the patient safety practices evaluated the implementation was considered insufficient: illegible handwriting, medication reconciliation, standardization of communication systems, early warning systems, procedures performed or equipment used only by trained people, and compliance with patient preferences at the end of life. Improve compliance of with hand hygiene and barrier precautions to prevent infections, ensure the correct identification of patients and the use of checklists are the four practices in which more than 75% of respondents found a high degree of consensus on the usefulness of traffic sings to broaden their use. Conclusion: The differences between perceived need and actual implementation in some safe practices indicate areas for improvement in patient safety. With this aim, the common language and the iconicity of traffic signs could constitute a simple instrument to improve compliance with safe practices for patient safety


Asunto(s)
Humanos , Seguridad del Paciente/normas , Gestión de Riesgos/métodos , Daño del Paciente/prevención & control , Enfermedad Iatrogénica/prevención & control , Efectos Colaterales y Reacciones Adversas Relacionados con Medicamentos/prevención & control , Evaluación de Necesidades/organización & administración , Guías de Práctica Clínica como Asunto
16.
Gac Sanit ; 33(3): 242-248, 2019.
Artículo en Español | MEDLINE | ID: mdl-29395125

RESUMEN

OBJECTIVE: To evaluate differences between the need and degree of implementation of safe practices recommended for patient safety and to check the usefulness of traffic sign iconicity to promote their implementation. METHOD: The study was developed in two stages: 1) review of safe practices recommended by different organizations and 2) a survey to assess the perceptions for the need and implementation of them and the usefulness of signs to improve their implementation. The sample consisted of professionals from Spain and Latin America working in healthcare settings and in the academic field related to patient safety. RESULTS: 365 questionnaires were collected. All safe practices included were considered necessary (mean and lower limit of confidence interval over 3 out of 5 points). However, in six of the patient safety practices evaluated the implementation was considered insufficient: illegible handwriting, medication reconciliation, standardization of communication systems, early warning systems, procedures performed or equipment used only by trained people, and compliance with patient preferences at the end of life. Improve compliance of with hand hygiene and barrier precautions to prevent infections, ensure the correct identification of patients and the use of checklists are the four practices in which more than 75% of respondents found a high degree of consensus on the usefulness of traffic sings to broaden their use. CONCLUSION: The differences between perceived need and actual implementation in some safe practices indicate areas for improvement in patient safety. With this aim, the common language and the iconicity of traffic signs could constitute a simple instrument to improve compliance with safe practices for patient safety.


Asunto(s)
Adhesión a Directriz/estadística & datos numéricos , Adhesión a Directriz/normas , Necesidades y Demandas de Servicios de Salud , Seguridad del Paciente/normas , Humanos , América Latina , España
17.
Sensors (Basel) ; 18(6)2018 Jun 07.
Artículo en Inglés | MEDLINE | ID: mdl-29880731

RESUMEN

Here, we present a novel method to fabricate long period gratings using standard single mode optical fibers (SMF). These optical devices were fabricated in a three-step process, which consisted of etching the SMF, then coating it with a thin-film and, the final step, which involved removing sections of the coating periodically by laser ablation. Tin dioxide was chosen as the material for this study and it was sputtered using a pulsed DC sputtering system. Theoretical simulations were performed in order to select the appropriate parameters for the experiments. The responses of two different devices to different external refractive indices was studied, and the maximum sensitivity obtained was 6430 nm/RIU for external refractive indices ranging from 1.37 to 1.39.

18.
ACS Sens ; 3(5): 936-943, 2018 05 25.
Artículo en Inglés | MEDLINE | ID: mdl-29726679

RESUMEN

The advent of optical fiber-based biosensors combined with that of nanotechnologies has provided an opportunity for developing in situ, portable, lightweight, versatile, and high-performance optical sensing platforms. We report on the generation of lossy mode resonances by the deposition of nanometer-thick metal oxide films on optical fibers, which makes it possible to measure precisely and accurately the changes in optical properties of the fiber-surrounding medium with very high sensitivity compared to other technology platforms, such as long period gratings or surface plasmon resonances, the gold standard in label-free and real-time biomolecular interaction analysis. This property, combined with the application of specialty structures such as D-shaped fibers, permits enhancing the light-matter interaction. SEM and TEM imaging together with X-EDS tool have been utilized to characterize the two films used, i.e., indium tin oxide and tin dioxide. Moreover, the experimental transmission spectra obtained after the deposition of the nanocoatings have been numerically corroborated by means of wave propagation methods. With the use of a conventional wavelength interrogation system and ad hoc developed microfluidics, the shift of the lossy mode resonance can be reliably recorded in response to very low analyte concentrations. Repeated experiments confirm a big leap in performance thanks to the capability to detect femtomolar concentrations in human serum, improving the detection limit by 3 orders of magnitude when compared with other fiber-based configurations. The biosensor has been regenerated several times by injecting sodium dodecyl sulfate, which proves the capability of sensor to be reused.


Asunto(s)
Técnicas Biosensibles , Nanotecnología , Fibras Ópticas , Bioensayo , Límite de Detección , Microscopía Electrónica de Rastreo , Microscopía Electrónica de Transmisión , Compuestos de Estaño/química
19.
Sensors (Basel) ; 17(10)2017 Oct 11.
Artículo en Inglés | MEDLINE | ID: mdl-29019945

RESUMEN

The measurement of chemical and biomedical parameters can take advantage of the features exclusively offered by optical fibre: passive nature, electromagnetic immunity and chemical stability are some of the most relevant ones. The small dimensions of the fibre generally require that the sensing material be loaded into a supporting matrix whose morphology is adjusted at a nanometric scale. Thanks to the advances in nanotechnology new deposition methods have been developed: they allow reagents from different chemical nature to be embedded into films with a thickness always below a few microns that also show a relevant aspect ratio to ensure a high transduction interface. This review reveals some of the main techniques that are currently been employed to develop this kind of sensors, describing in detail both the resulting supporting matrices as well as the sensing materials used. The main objective is to offer a general view of the state of the art to expose the main challenges and chances that this technology is facing currently.

20.
Sensors (Basel) ; 17(9)2017 Sep 13.
Artículo en Inglés | MEDLINE | ID: mdl-28902137

RESUMEN

The diameter of long-period fiber gratings (LPFGs) fabricated in optical fibers with a low cutoff wavelength was be reduced by hydrofluoric acid etching, enhancing the sensitivity to refractive index by more than a factor of 3, to 2611 nm/refractive index unit in the range from 1.333 to 1.4278. The grating period selected for the LPFGs allowed access to the dispersion turning point at wavelengths close to the visible range of the optical spectrum, where optical equipment is less expensive. As an example of an application, a pH sensor based on the deposition of a polymeric coating was analyzed in two situations: with an LPFG without diameter reduction and with an LPFG with diameter reduction. Again, a sensitivity increase of a factor of near 3 was obtained, demonstrating the ability of this method to enhance the sensitivity of thin-film-coated LPFG chemical sensors.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...