Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Gastrointest Endosc ; 2024 Apr 03.
Artículo en Inglés | MEDLINE | ID: mdl-38580134

RESUMEN

BACKGROUND AND AIMS: Endoscopists' competence can vary widely, as shown in the variation in adenoma detection rate (ADR). Computer-aided quality assessment (CAQ) can automatically assess performance during individual procedures. This review aims to identify and describe different CAQ systems for colonoscopy. METHODS: A systematic review of the literature was done using MEDLINE, EMBASE, and SCOPUS based on three blocks of terms according to the inclusion criteria: Colonoscopy, Competence assessment, and Automatic evaluation. Articles were systematically reviewed by two reviewers, first by abstract and then in full text. The methodological quality was assessed using the Medical Education Research Study Quality Instrument (MERSQI). RESULTS: 12,575 studies were identified, 6,831 remained after removal of duplicates, and 6,806 did not pass the eligibility criteria and were excluded, leaving thirteen studies for final analysis. Five categories of CAQ systems were identified: Withdrawal speedometer (seven studies), Scope movement analysis (three studies), Effective withdrawal time (one study), Fold examination quality (one study), and Visual gaze pattern (one study). The withdrawal speedometer was the only CAQ system that tested its feedback by examining changes in ADR. Three studies observed an improvement in ADR, and two studies did not. The methodological quality of the studies was high (mean MERSQI 15.2 points, maximum 18 points). CONCLUSIONS: Thirteen studies developed or tested CAQ systems, most frequently by correlating it to ADR. Only five studies tested feedback by implementing the CAQ system. A meta-analysis was impossible due to the heterogeneous study designs, and more studies are warranted.

2.
Gastrointest Endosc ; 95(5): 1002-1010, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-34979117

RESUMEN

BACKGROUND AND AIMS: The success of preventing colorectal cancer relies on the expertise of the colonoscopists. Studies suggest that the retraction technique is a powerful indicator of expertise in distinguishing endoscopists with various adenoma detection rates (ADRs). We aimed to develop a retraction technique score and explore the correlation between endoscopists' retraction technique and their ADRs. METHODS: In a prospective, multicenter study, 8 colonoscopist nurses and physicians with various ADRs were included. Data from patients admitted for a colonoscopy, as part of the Danish nationwide screening program, were gathered directly from the Olympus ScopeGuide system (UPD-3; Olympus Optical, Tokyo, Japan) providing XYZ-coordinates from the coils along the length of the colonoscope. Motor skill measures were developed based on tip retraction, retraction efficiency, and retraction distance. The principal component analysis was used to study the association among the 3 measures and the historical ADR to create a combined score, the colonoscopy retraction score (CoRS). RESULTS: Three hundred thirty-three recordings were analyzed. We demonstrated a significant and strong correlation between CoRS and ADR (.90, P < .01). Conversely, withdrawal time did not correlate significantly with ADR (.33, P = .42). In procedures without polypectomies or biopsy sampling, a significant and strong correlation was found between CoRS and ADR (.88, P < .01) and between withdrawal time and ADR (.75, P = .03). CONCLUSIONS: This study presents a novel, real-time computerized and unbiased assessment tool for colonoscopy withdrawal. CoRS strongly correlated with ADR with and without therapeutic interventions during withdrawal and could be used to ensure quality instead of minimal withdrawal time. (Clinical trial registration number: NCT03587935.).


Asunto(s)
Adenoma , Neoplasias Colorrectales , Adenoma/diagnóstico , Adenoma/patología , Colonoscopios , Colonoscopía/métodos , Neoplasias Colorrectales/diagnóstico , Neoplasias Colorrectales/patología , Detección Precoz del Cáncer , Humanos , Estudios Prospectivos
3.
Endosc Int Open ; 8(6): E783-E791, 2020 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-32490164

RESUMEN

Background and study aims Patient safety during a colonoscopy highly depends on endoscopist competence. Endoscopic societies have been calling for an objective and regular assessment of the endoscopists, but existing assessment tools are time-consuming and prone to bias. We aimed to develop and gather evidence of validity for a computerized assessment tool delivering automatic and unbiased assessment of colonoscopy based on 3 dimensional coordinates from the colonoscope. Methods Twenty-four participants were recruited and divided into two groups based on experience: 12 experienced and 12 novices. Participants performed twice on a physical phantom model with a standardized alpha loop in the sigmoid colon. Data was gathered directly from the Olympus ScopeGuide system providing XYZ-coordinates along the length of the colonoscope. Five different motor skill measures were developed based on the data, named: Travel Length, Tip Progression, Chase Efficiency, Shaft movement without tip progression, and Looping. Results The experinced had a lower travel length ( P  < 0.001), tip progression ( P  < 0.001), chase efficiency ( P  = 0.001) and looping ( P  = 0.006), and a higher shaft movement without tip progression ( P  < 0.001) reaching the cecum compared with the novices. A composite score was developed based on the five measurements to create a combined score of progression, the 3D-Colonoscopy-Progression-Score (3D-CoPS). The 3D-CoPS revealed a significant difference between groups (experienced: 0.495 (SD 0.303) and novices -0.454 (SD 0.707), P  < 0.001). Conclusion This study presents a novel, real-time computerized assessment tool for colonoscopy, and strong evidence of validity was gathered in a simulation-based setting. The system shows promising opportunities for automatic, unbiased and continuous assessment of colonoscopy performance.

4.
Gastrointest Endosc ; 88(5): 869-876, 2018 11.
Artículo en Inglés | MEDLINE | ID: mdl-30031803

RESUMEN

BACKGROUND AND AIMS: Simulation-based training in colonoscopy is increasingly replacing the traditional apprenticeship method to avoid patient-related risk. Mentoring during simulation is necessary to provide feedback and to motivate, but expert supervisors are a scarce resource. We aimed to determine whether computerized feedback in simulated colonoscopy would improve performance, optimize time spent practicing, and optimize the pattern of training. METHODS: Forty-four participants were recruited and randomized to either a feedback group (FG) or a control group (CG). Participants were allowed 2 hours of self-practice during which they could practice as they saw fit on 2 different cases: 1 easy and 1 difficult. The CG practiced without feedback, but the participants in the FG were given a score of progression every time they reached the cecum. All participants were tested on a different case after end of training. The primary outcome was the progression score in the final case, and secondary outcomes were time spent practicing and the training pattern. RESULTS: Regression analysis adjusting for sex was done because of an uneven sex distribution between groups (P = .026) and significantly higher performance scores by men (37.6, standard deviation [SD] 25.9) compared with women (19.7, SD 18.7); P = .012. The FG outperformed the CG in the final case, FG scoring 14.4 points (95% confidence interval [CI], 1.2-27.6) more than the CG; P = .033, and they spent more time practicing, FG practicing 25.8 minutes (95% CI, 11.6-39.9) more than the CG; P = .001. The FG practiced more on the easy case and reached the cecum 3.2 times more (95% CI, 2-4.5) during practice (P < .001). CONCLUSIONS: Our findings of this study revealed that an automatic, computerized score of progression during simulated colonoscopy motivates the novices to improve performance, optimizes time spent practicing, and optimizes their pattern of training. (Clinical trial registration number: NCT03248453.).


Asunto(s)
Colonoscopía/métodos , Computadores , Educación de Postgrado en Medicina/métodos , Retroalimentación , Entrenamiento Simulado/métodos , Adulto , Competencia Clínica , Dinamarca , Femenino , Humanos , Internado y Residencia/métodos , Modelos Logísticos , Masculino , Análisis Multivariante , Aprendizaje Basado en Problemas/métodos
5.
Ugeskr Laeger ; 176(50)2014 Dec 08.
Artículo en Danés | MEDLINE | ID: mdl-25498187

RESUMEN

Pain is among the most common symptoms in patients with pancreatic cancer and up to 80% require analgesics, most often as opioids. Unfortunately the analgesic effect is frequently insufficient, and increasing doses are required, resulting in unpleasant side effects. Endoscopic ultrasound-guided neurolysis is a well established method to alleviate or reduce pain due to pancreatic cancer with a documented effect in 80% of patients. The aim of this review is to draw attention to endoscopic ultrasound-guided neurolysis and to discuss its potential which may not be fully utilized.


Asunto(s)
Dolor Abdominal/terapia , Bloqueo Nervioso Autónomo/métodos , Plexo Celíaco/cirugía , Neoplasias Pancreáticas/complicaciones , Dolor Abdominal/diagnóstico por imagen , Dolor Abdominal/etiología , Plexo Celíaco/diagnóstico por imagen , Endosonografía/métodos , Humanos , Manejo del Dolor/métodos , Ultrasonografía , Ultrasonografía Intervencional
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...