Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
J Ultrasound ; 20(1): 1-9, 2017 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-28298939

RESUMEN

Endoscopy remains the main technique in the diagnosis and treatment of Crohn's disease (CD); nevertheless, the recent development of innovative and non-invasive imaging techniques has led to a new tool in the exploration of small bowel in CD patients. This paper reviews the available data on ultrasound imaging used for the evaluation of CD, highlighting the role of small intestine contrast-enhanced ultrasonography with the use of oral and intravenous contrast agents.


Asunto(s)
Medios de Contraste , Enfermedad de Crohn/diagnóstico por imagen , Ultrasonografía/métodos , Administración Intravenosa , Administración Oral , Humanos , Intestino Delgado/diagnóstico por imagen
2.
Abdom Imaging ; 36(2): 142-8, 2011 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-20464392

RESUMEN

The evaluation of inflammatory activity in Crohn's disease (CD), a crucial aspect of treatment planning and monitoring, is currently based on a sum of clinical data and imaging findings. Among the contrast enhanced cross-sectional imaging techniques (CE-US, CE-CT, CE-MR), CE-US is less invasive, more comfortable for the patient, and has significant diagnostic accuracy. In addition, it is a portable, easily repeatable, well tolerated, and ionizing radiation-free imaging modality. CE-US has been introduced as effective method in the quantitative and qualitative evaluation of CD inflammatory activity. CE-US might help in characterizing bowel-wall thickening by differentiating inflammatory neovascularisation, edema, and fibrosis. The recent chance to evaluate the bowel-wall stiffness by US elastography imaging could allow further assessment of fibrosis that characterizes the evolution of the inflammatory activity.


Asunto(s)
Medios de Contraste , Enfermedad de Crohn/diagnóstico por imagen , Ultrasonografía/métodos , Humanos , Inflamación/diagnóstico por imagen , Microburbujas
3.
Recenti Prog Med ; 101(5): 185-93, 2010 May.
Artículo en Italiano | MEDLINE | ID: mdl-20590014

RESUMEN

Improvements in the ultrasound examination of bowel disease have registered in the last years the introduction of new technologies regarding high frequency probes (US), highly sensitive color or power Doppler units (CD-US), and the development of new non-linear technologies that optimize detection of microbubbles contrast agents responses. Contrast-enhanced ultrasound (CE-US) most importantly increases the results in sonographic evaluation of Crohn disease inflammatory activity. CE-US has become an imaging modality routinely employed in the clinical practice for the evaluation of parenchymal organs due to the introduction of new generation microbubble contrast agents which persist in the bloodstream for several minutes after intravenous injection. The availability of high frequency dedicated contrast-specific US techniques provide accurate depiction of small bowel wall perfusion due to the extremely high sensitivity of non-linear signals produced by microbubble insonation. In Crohn's disease, CE-US may characterize the bowel wall thickness by differentiating fibrosis from edema and may grade the inflammatory disease activity by assessing the presence and distribution of vascularity within the layers of the bowel wall (submucosa alone or the entire bowel wall). Peri-intestinal inflammatory involvement can be also characterized. CE-US can provide prognostic data concerning clinical recurrence of the inflammatory disease and evaluate the efficacy of drugs treatments.


Asunto(s)
Medios de Contraste , Enfermedad de Crohn/diagnóstico por imagen , Ultrasonografía Doppler en Color/métodos , Enfermedad de Crohn/patología , Humanos , Microburbujas , Valor Predictivo de las Pruebas , Sensibilidad y Especificidad , Índice de Severidad de la Enfermedad
4.
Gastroenterology ; 137(1): 43-52, 2009 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-19422826

RESUMEN

BACKGROUND & AIMS: We sought to test the diagnostic accuracy of ultrasound (US), color Doppler US (CD-US), and contrast-enhanced US (CE-US) in the evaluation of inflammatory activity in patients with Crohn's disease (CD), and to correlate the findings of these sonographic studies with inflammatory activity, as scored by the CD activity index (CDAI). METHODS: Patients with CD were enrolled in the study. Radiologists performing the scans were blinded to clinical status. Baseline US, CD-US, and CE-US examinations were conducted with high-frequency probes (8-14 and 5-7 MHz) before and after injection of sulfur hexafluoride-filled microbubbles. The diagnostic accuracy of baseline US, CD-US, and CE-US were calculated by using the endoscopic and histologic findings as reference standards and correlated with the CDAIs by using the Pearson linear correlation coefficient. RESULTS: Forty-seven patients (20 men; 27 women; mean age +/- SD, 38 +/- 14 years) with a CDAI > 150 (n = 30) or < 150 (n = 17), were recruited. CE-US showed the highest performance, with 93.5% sensitivity, 93.7% specificity, and 93.6% overall accuracy. CE-US revealed 3 bowel wall perfusion patterns after microbubble injection: submucosal enhancement and inward and outward transparietal enhancement. The linear correlation coefficient for CE-US versus CDAI was 0.74 (P < .0001); for baseline US (assessing thickness, length, and multilayer appearance of the diseased bowel) versus the CDAI, the coefficients were 0.68 (P < .0001), 0.47 (P = .0009), and 0.60 (P < .0001), respectively; and for CD-US versus CDAI the coefficient was 0.73 (P < .0001). CONCLUSIONS: CE-US has a high sensitivity and specificity in detecting inflammatory activity and a strong correlation with the CDAI.


Asunto(s)
Medios de Contraste , Enfermedad de Crohn/diagnóstico por imagen , Hexafluoruro de Azufre , Ultrasonografía Doppler en Color , Adolescente , Adulto , Anciano , Enfermedad de Crohn/patología , Femenino , Humanos , Masculino , Microburbujas , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Sensibilidad y Especificidad , Índice de Severidad de la Enfermedad , Adulto Joven
5.
Abdom Imaging ; 33(5): 589-97, 2008.
Artículo en Inglés | MEDLINE | ID: mdl-18172707

RESUMEN

Improvements in the ultrasound examination of bowel disease have registered in the last years the introduction of new technologies regarding high frequency probes (US), highly sensitive color or power Doppler units (CD-US), and the development of new non-linear technologies that optimize detection of contrast agents. Contrast-enhanced ultrasound (CE-US) most importantly increases the results in sonographic evaluation of Crohn disease inflammatory activity. CE-US has become an imaging modality routinely employed in the clinical practice for the evaluation of parenchymal organs due to the introduction of new generation microbubble contrast agents which persist in the bloodstream for several minutes after intravenous injection. The availability of high frequency dedicated contrast-specific US techniques provide accurate depiction of small bowel wall perfusion due to the extremely high sensitivity of non-linear signals produced by microbubble insonation. In Crohn's disease, CE-US may characterize the bowel wall thickness by differentiating fibrosis from edema and may grade the inflammatory disease activity by assessing the presence and distribution of vascularity within the layers of the bowel wall (submucosa alone or the entire bowel wall). Peri-intestinal inflammatory involvement can be also characterized. CE-US can provide prognostic data concerning clinical recurrence of the inflammatory disease and evaluate the efficacy of drugs treatments.


Asunto(s)
Enfermedad de Crohn/diagnóstico por imagen , Ultrasonografía Doppler en Color , Medios de Contraste , Humanos , Inflamación/diagnóstico por imagen , Pronóstico
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...