Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Int J Cardiol ; 405: 131939, 2024 Jun 15.
Artículo en Inglés | MEDLINE | ID: mdl-38458388

RESUMEN

BACKGROUND: Advances in imaging have led to procedural optimization of left atrial appendage closure (LAAC). Contrast-free approaches, guided merely by echocardiography, have been established, however data on this topic remains scarce. In this analysis, we assessed contrast-free procedural results with the LAMBRE LAAC device. METHODS: The multicenter retrospective BoBoMa (Bonn/Bordeaux/Mainz)-Registry included a total of 118 patients that underwent LAAC with LAMBRE devices omitting contrast-dye. Baseline and echocardiographic characteristics as well as intra- and postprocedural complications and outcomes were assessed. RESULTS: Patients were at a mean age of 77.5 ± 7.5 years with high thromboembolic and bleeding risk (CHADS-VASc-score 4.6 ± 1.4, HAS-BLED-score 3.7 ± 1.0, respectively). Renal function was impaired with a mean glomerular filtration rate (GFR) of 50 ± 22 ml/min. Mean procedural time was 47.2 ± 37.5  minutes with a mean radiation dose of 4.75 ± 5.25 Gy*cm2. Device success, defined as proper deployment in a correct position, was achieved in 97.5% (115/118) of cases with repositioning of the occluder in 7.6% (9/118) and resizing in 3.4% (4/118) of cases. No relevant peri-device leakage (>3 mm) was observed with 42% of occluders being implanted in an ostial position. Periprocedural complications occurred in 6.8% (8/118) of cases, including two cases of device embolization and one case of clinically-relevant pericardial effusion requiring surgical intervention. Other complications included pericardial effusion (2.5%, 3/118) and vascular access site complications (1.7%, 2/118). CONCLUSION: Echocardiography-guided contrast-free LAAC using the LAMBRE device is safe and feasible. Further prospective studies including the direct comparison of devices as well as imaging techniques are warranted in contrast-free LAAC.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Dispositivo Oclusor Septal , Humanos , Apéndice Atrial/cirugía , Apéndice Atrial/diagnóstico por imagen , Masculino , Femenino , Anciano , Estudios Retrospectivos , Fibrilación Atrial/cirugía , Fibrilación Atrial/diagnóstico por imagen , Anciano de 80 o más Años , Sistema de Registros , Resultado del Tratamiento , Ecocardiografía Transesofágica/métodos , Medios de Contraste/administración & dosificación , Estudios de Seguimiento
2.
Clin Res Cardiol ; 112(12): 1790-1799, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37294311

RESUMEN

BACKGROUND: Device-related thrombus (DRT) after left atrial appendage closure (LAAC) is associated with adverse outcomes, i.e. ischemic stroke or systemic embolism (SE). Data on predictors of stroke/SE in the context of DRT are limited. AIMS: This study aimed to identify predisposing factors for stroke/SE in DRT patients. In addition, the temporal connection of stroke/SE to DRT diagnosis was analyzed. METHODS: The EUROC-DRT registry included 176 patients, in whom DRT after LAAC were diagnosed. Patients with symptomatic DRT, defined as stroke/SE in the context of DRT diagnosis, were compared against patients with non-symptomatic DRT. Baseline characteristics, anti-thrombotic regimens, device position, and timing of stroke/SE were compared. RESULTS: Stroke/SE occurred in 25/176 (14.2%) patients diagnosed with DRT (symptomatic DRT). Stroke/SE occurred after a median of 198 days (IQR 37-558) after LAAC. In 45.8% stroke/SE occurred within one month before/after DRT diagnosis (DRT-related stroke). Patients with symptomatic DRT had lower left ventricular ejection fractions (50.0 ± 9.1% vs. 54.2 ± 11.0%, p = 0.03) and higher rates of non-paroxysmal atrial fibrillation (84.0% vs. 64.9%, p = 0.06). Other baseline parameters and device positions were not different. Most ischemic events occurred among patients with single antiplatelet therapy (50%), however, stroke/SE was also observed under dual antiplatelet therapy (25%) or oral anticoagulation (20%). CONCLUSION: Stroke/SE are documented in 14.2% and occur both in close temporal relation to the DRT finding and chronologically independently therefrom. Identification of risk factors remains cumbersome, putting all DRT patients at substantial risk for stroke/SE. Further studies are necessary to minimize the risk of DRT and ischemic events.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Accidente Cerebrovascular , Trombosis , Humanos , Resultado del Tratamiento , Fibrilación Atrial/complicaciones , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/epidemiología , Trombosis/diagnóstico , Trombosis/epidemiología , Trombosis/etiología , Accidente Cerebrovascular/diagnóstico , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/etiología , Sistema de Registros , Apéndice Atrial/diagnóstico por imagen
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...