Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Clin Res Cardiol ; 112(5): 667-676, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-36656376

RESUMEN

BACKGROUND: Ejection time (ET), acceleration time (AT) and time between left ventricular and aortic systolic pressure peaks (T-LVAo) might be of diagnostic and prognostic use in patients with aortic stenosis (AS) undergoing transcatheter aortic valve implantation (TAVI). AIM: We aimed to assess the diagnostic value and prognostic impact of invasively measured ET, AT, and T-LVAo in patients undergoing TAVI. METHODS: A total of 1274 patients received invasive measurement of ET, AT and T-LVAo prior to TAVI. Anatomic AS severity was assessed by CT-derived aortic valve calcification density (AVCd). Impact on all-cause mortality was retrospectively analyzed. RESULTS: In multivariable linear regression, T-LVAo showed the strongest correlation with AVCd. No prognostic impact of T-LVAo was found according to uni- and multivariable analyses. In contrast, using an individual C-statistic derived cutoff (CD), patients with ET or AT ≥ CD showed lower mortality rates compared to patients with ET or AT < CD (1-year mortality: ET ≥ vs. < CD: 15.01vs. 33.1%, AT ≥ vs < CD 16.3 vs. 26.5%, p < 0.001). Moreover, multivariable analysis identified ET ≥ CD (HR 0.61 [95% CI 0.43-0.87; p < 0.007]) to be associated with beneficial outcome after TAVI, independent from clinical risk factors and echocardiography-derived parameters. CONCLUSION: Among the studied hemodynamic parameters T-LVAo provides the highest diagnostic value, whereas ET is an outcome predictor beyond clinical risk factors and echocardiographic parameters in AS patients following TAVI. These parameters could be of considerable use in diagnostic evaluation and risk assessment of patients scheduled for TAVI. T-LVAo (yellow): defined as time between left ventricular and aortic systolic pressure peaks. ET (green): Ejection Time defined as time from the start to flow end. AT (orange): Acceleration time defined as time from the start to the peak flow. AOP: aortic pressure, AVC: aortic valve calcification, CI: confidence interval, HGAS: high-gradient aortic stenosis, LGAS: low-gradient aortic stenosis, LVP: left ventricular pressure, SD: standard deviation.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Estudios Retrospectivos , Resultado del Tratamiento , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Hemodinámica , Función Ventricular Izquierda , Volumen Sistólico , Índice de Severidad de la Enfermedad
2.
JACC Cardiovasc Interv ; 15(15): 1543-1554, 2022 08 08.
Artículo en Inglés | MEDLINE | ID: mdl-35926921

RESUMEN

BACKGROUND: As transcatheter aortic valve (TAV) replacement is increasingly used in patients with longer life expectancy, a sizable proportion will require redo TAV replacement (TAVR). The unique configuration of balloon-expandable TAV (bTAV) vs a self-expanding TAV (sTAV) potentially affects TAV-in-TAV outcome. OBJECTIVES: The purpose of this study was to better inform prosthesis selection, TAV-in-TAV outcomes were assessed according to the type of initial and subsequent TAV. METHODS: Patients from the Redo-TAVR registry were analyzed using propensity weighting according to their initial valve type (bTAV [n = 115] vs sTAV [n = 106]) and subsequent valve type (bTAV [n = 130] vs sTAV [n = 91]). RESULTS: Patients with failed bTAVs presented later (vs sTAV) (4.9 ± 2.1 years vs 3.7 ± 2.3 years; P < 0.001), with smaller effective orifice area (1.0 ± 0.7 cm2 vs 1.3 ± 0.8 cm2; P = 0.018) and less frequent dominant regurgitation (16.2% vs 47.3%; P < 0.001). Mortality at 30 days was 2.3% (TAV-in-bTAV) vs 0% (TAV-in-sTAV) (P = 0.499) and 1.7% (bTAV-in-TAV) vs 1.0% (sTAV-in-TAV) (P = 0.612); procedural safety was 72.6% (TAV-in-bTAV) vs 71.2% (TAV-in-sTAV) (P = 0.817) and 73.2% (bTAV-in-TAV) vs 76.5% (sTAV-in-TAV) (P = 0.590). Device success was similar according to initial valve type but higher with subsequent sTAV vs bTAV (77.2% vs 64.3%; P = 0.045), primarily because of lower residual gradients (10.3 mm Hg [8.9-11.7 mm Hg] vs 15.2 mm Hg [13.2-17.1 mm Hg]; P < 0.001). Residual regurgitation (moderate or greater) was similar after bTAV-in-TAV and sTAV-in-TAV (5.7%) and nominally higher after TAV-in-bTAV (9.1%) vs TAV-in-sTAV (4.4%) (P = 0.176). CONCLUSIONS: In selected patients, no association was observed between TAV type and redo TAVR safety or mortality, yet subsequent sTAV was associated with higher device success because of lower redo gradients. These findings are preliminary, and more data are needed to guide valve choice for redo TAVR.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Humanos , Diseño de Prótesis , Sistema de Registros , Factores de Riesgo , Resultado del Tratamiento
3.
J Am Coll Cardiol ; 75(16): 1882-1893, 2020 04 28.
Artículo en Inglés | MEDLINE | ID: mdl-32327098

RESUMEN

BACKGROUND: Transcatheter aortic valve replacement (TAVR) use is increasing in patients with longer life expectancy, yet robust data on the durability of transcatheter heart valves (THVs) are limited. Redo-TAVR may play a key strategy in treating patients in whom THVs fail. OBJECTIVES: The authors sought to examine outcomes following redo-TAVR. METHODS: The Redo-TAVR registry collected data on consecutive patients who underwent redo-TAVR at 37 centers. Patients were classified as probable TAVR failure or probable THV failure if they presented within or beyond 1 year of their index TAVR, respectively. RESULTS: Among 63,876 TAVR procedures, 212 consecutive redo-TAVR procedures were identified (0.33%): 74 within and 138 beyond 1 year of the initial procedure. For these 2 groups, TAVR-to-redo-TAVR time was 68 (38 to 154) days and 5 (3 to 6) years. The indication for redo-TAVR was THV stenosis in 12 (16.2%) and 51 (37.0%) (p = 0.002) and regurgitation or combined stenosis-regurgitation in 62 (83.8%) and 86 (62.3%) (p = 0.028), respectively. Device success using VARC-2 criteria was achieved in 180 patients (85.1%); most failures were attributable to high residual gradients (14.1%) or regurgitation (8.9%). At 30-day and 1-year follow-up, residual gradients were 12.6 ± 7.5 mm Hg and 12.9 ± 9.0 mm Hg; valve area 1.63 ± 0.61 cm2 and 1.51 ± 0.57 cm2; and regurgitation ≤mild in 91% and 91%, respectively. Peri-procedural complication rates were low (3 stroke [1.4%], 7 valve malposition [3.3%], 2 coronary obstruction [0.9%], 20 new permanent pacemaker [9.6%], no mortality), and symptomatic improvement was substantial. Survival at 30 days was 94.6% and 98.5% (p = 0.101) and 83.6% and 88.3% (p = 0.335) at 1 year for patients presenting with early and late valve dysfunction, respectively. CONCLUSIONS: Redo-TAVR is a relatively safe and effective option for selected patients with valve dysfunction after TAVR. These results are important for applicability of TAVR in patients with long life expectancy in whom THV durability may be a concern.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Estenosis de la Válvula Aórtica/cirugía , Prótesis Valvulares Cardíacas/efectos adversos , Complicaciones Posoperatorias , Reoperación , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/diagnóstico , Insuficiencia de la Válvula Aórtica/epidemiología , Insuficiencia de la Válvula Aórtica/etiología , Insuficiencia de la Válvula Aórtica/cirugía , Análisis de Falla de Equipo , Femenino , Salud Global , Humanos , Masculino , Evaluación de Resultado en la Atención de Salud , Complicaciones Posoperatorias/diagnóstico , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/cirugía , Sistema de Registros/estadística & datos numéricos , Reoperación/instrumentación , Reoperación/métodos , Reoperación/estadística & datos numéricos , Análisis de Supervivencia , Evaluación de Síntomas/estadística & datos numéricos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Reemplazo de la Válvula Aórtica Transcatéter/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...