Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
1.
Neurocrit Care ; 40(2): 698-706, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37639204

RESUMEN

BACKGROUND: Even though mechanical recanalization techniques have dramatically improved acute stroke care since the pivotal trials of decompressive hemicraniectomy for malignant courses of ischemic stroke, decompressive hemicraniectomy remains a mainstay of malignant stroke treatment. However, it is still unclear whether prior thrombectomy, which in most cases is associated with application of antiplatelets and/or anticoagulants, affects the surgical complication rate of decompressive hemicraniectomy and whether conclusions derived from prior trials of decompressive hemicraniectomy are still valid in times of modern stroke care. METHODS: A total of 103 consecutive patients who received a decompressive hemicraniectomy for malignant middle cerebral artery infarction were evaluated in this retrospective cohort study. Surgical and functional outcomes of patients who had received mechanical recanalization before surgery (thrombectomy group, n = 49) and of patients who had not received mechanical recanalization (medical group, n = 54) were compared. RESULTS: The baseline characteristics of the two groups did significantly differ regarding preoperative systemic thrombolysis (63.3% in the thrombectomy group vs. 18.5% in the medical group, p < 0.001), the rate of hemorrhagic transformation (44.9% vs. 24.1%, p = 0.04) and the preoperative Glasgow Coma Score (median of 7 in the thrombectomy group vs. 12 in the medical group, p = 0.04) were similar to those of prior randomized controlled trials of decompressive hemicraniectomy. There was no significant difference in the rates of surgical complications (10.2% in the thrombectomy group vs. 11.1% in the medical group), revision surgery within the first 30 days after surgery (4.1% vs. 5.6%, respectively), and functional outcome (median modified Rankin Score of 4 at 5 and 14 months in both groups) between the two groups. CONCLUSIONS: A prior mechanical recanalization with possibly associated systemic thrombolysis does not affect the early surgical complication rate and the functional outcome after decompressive hemicraniectomy for malignant ischemic stroke. Patient characteristics have not changed significantly since the introduction of mechanical recanalization; therefore, the results from former large randomized controlled trials are still valid in the modern era of stroke care.


Asunto(s)
Craniectomía Descompresiva , Accidente Cerebrovascular Isquémico , Accidente Cerebrovascular , Humanos , Craniectomía Descompresiva/efectos adversos , Craniectomía Descompresiva/métodos , Infarto de la Arteria Cerebral Media/cirugía , Infarto de la Arteria Cerebral Media/complicaciones , Accidente Cerebrovascular Isquémico/cirugía , Estudios Retrospectivos , Accidente Cerebrovascular/cirugía , Accidente Cerebrovascular/etiología , Trombectomía , Resultado del Tratamiento , Ensayos Clínicos Controlados Aleatorios como Asunto
2.
Int J Hyperthermia ; 40(1): 2205071, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37127281

RESUMEN

OBJECTIVES: To compare metal artifacts and evaluation of metal artifact reduction algorithms during probe positioning in computed tomography (CT)-guided microwave ablation (MWA), cryoablation (CRYO), and radiofrequency ablation (RFA). MATERIALS AND METHODS: Using CT guidance, individual MWA, CRYO, and RFA ablation probes were placed into the livers of 15 pigs. CT imaging was then performed to determine the probe's position within the test subject's liver. Filtered back projection (B30f) and iterative reconstructions (I30-1) were both used with and without dedicated iterative metal artifact reduction (iMAR) to generate images from the initial data sets. Semi-automatic segmentation-based quantitative evaluation was conducted to estimate artifact percentage within the liver, while qualitative evaluation of metal artifact extent and overall image quality was performed by two observers using a 5-point Likert scale: 1-none, 2-mild, 3-moderate, 4-severe, 5-non-diagnostic. RESULTS: Among MWA, RFA, and CRYO, compared with non-iMAR in B30f reconstruction, the largest extent of artifact volume percentages were observed for CRYO (11.5-17.9%), followed by MWA (4.7-6.6%) and lastly in RFA (5.5-6.2%). iMAR significantly reduces metal artifacts for CRYO and MWA quantitatively (p = 0.0020; p = 0.0036, respectively) and qualitatively (p = 0.0001, p = 0.0005), but not for RFA. No significant reduction in metal artifact percentage was seen after applying iterative reconstructions (p > 0.05). Noise, contrast-to-noise-ratio, or overall image quality did not differ between probe types, irrespective of the application of iterative reconstruction and iMAR. CONCLUSION: A dedicated metal artifact algorithm may decrease metal artifacts and improves image quality significantly for MWA and CRYO probes. Their application alongside with dedicated metal artifact algorithm should be considered during CT-guided positioning.


Asunto(s)
Artefactos , Criocirugía , Ablación por Radiofrecuencia , Tomografía Computarizada por Rayos X , Tomografía Computarizada por Rayos X/métodos , Algoritmos , Imágenes de Microonda , Porcinos , Animales
3.
AJNR Am J Neuroradiol ; 44(4): 474-480, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36997283

RESUMEN

BACKGROUND AND PURPOSE: Flow diverters with antithrombotic coatings are increasingly used to improve the safety of flow diverter treatments of intracranial aneurysms. This study aimed to investigate the safety and short-term efficacy of the new FRED X flow diverter. MATERIALS AND METHODS: Medical charts and procedural and imaging data of a consecutive series of patients with intracranial aneurysms who were treated with the FRED X at 9 international neurovascular centers were retrospectively analyzed. RESULTS: One hundred sixty-one patients (77.6% women; mean age, 55 years) with 184 aneurysms (11.2% acutely ruptured) were included in this study. Most aneurysms were located in the anterior circulation (77.0%), most frequently at the ICA (72.7%). The FRED X was successfully implanted in all procedures. Additional coiling was performed in 29.8%. In-stent balloon angioplasty was necessary in 2.5%. The rate of major adverse events was 3.1%. Thrombotic events occurred in 7 patients (4.3%) with 4 intra- and 4 postprocedural in-stent thromboses, respectively (1 patient had both peri- and postprocedural thrombosis). Of these thrombotic events, only 2 (1.2%) led to major adverse events (ischemic strokes). Postinterventional neurologic morbidity and mortality were observed in 1.9% and 1.2%, respectively. The rate of complete aneurysm occlusion after a mean follow-up of 7.0 months was 66.0%. CONCLUSIONS: The new FRED X is a safe and feasible device for aneurysm treatment. In this retrospective multicenter study, the rate of thrombotic complications was low, and the short-term occlusion rates are satisfactory.


Asunto(s)
Embolización Terapéutica , Procedimientos Endovasculares , Aneurisma Intracraneal , Humanos , Femenino , Persona de Mediana Edad , Masculino , Resultado del Tratamiento , Fibrinolíticos , Aneurisma Intracraneal/diagnóstico por imagen , Aneurisma Intracraneal/terapia , Estudios Retrospectivos , Procedimientos Endovasculares/métodos , Stents , Embolización Terapéutica/métodos
4.
AJNR Am J Neuroradiol ; 43(12): 1749-1755, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-36357152

RESUMEN

BACKGROUND AND PURPOSE: Endovascular embolization using liquid embolic agents is a safe and effective treatment option for AVMs and fistulas. Because reliable visibility of these liquid embolic agents is essential for intraprocedural visual control to prevent complications, novel angiographic systems are equipped with material-specific roadmap modes. The aim of this study was the systematic in vitro comparison of conventional and material-specific roadmap modes regarding the visibility of the most used liquid embolic agents. MATERIALS AND METHODS: A recently introduced in vitro model, resembling cerebral vessels, was embolized with Onyx 18, Squid 18, PHIL 25%, and n-BCA mixed with iodized oil (n = 4 for each liquid embolic agent), as well as with contrast medium and saline, both serving as a reference. Imaging was performed in conventional and material-specific roadmap modes. The visibility of the liquid embolic agents in both modes was compared quantitatively and qualitatively. RESULTS: Significant differences between conventional and material-specific roadmap modes regarding the visibility of the liquid embolic agents were observed for all study groups. All liquid embolic agents were better visible in the material-specific roadmap modes compared with the conventional mode in qualitative and quantitative analyses (eg, Onyx in conventional-versus-material-specific modes along the 1.0-mm sector: mean contrast-to-noise ratio, 5.69 [SD, 0.85] versus 47.18 [SD, 5.72]; P < .001, respectively). CONCLUSIONS: In this in vitro study, we demonstrated a better visibility of all investigated liquid embolic agents by using material-specific roadmap modes compared with the conventional roadmap technique. Especially in complex anatomic situations, these novel roadmap modes could improve the visual control and thus the safety and efficacy of embolization procedures in clinical practice.


Asunto(s)
Embolización Terapéutica , Malformaciones Arteriovenosas Intracraneales , Humanos , Dimetilsulfóxido/uso terapéutico , Embolización Terapéutica/métodos , Resultado del Tratamiento , Malformaciones Arteriovenosas Intracraneales/terapia , Polivinilos/uso terapéutico , Angiografía
5.
AJNR Am J Neuroradiol ; 42(1): 126-131, 2021 01.
Artículo en Inglés | MEDLINE | ID: mdl-33214178

RESUMEN

BACKGROUND AND PURPOSE: Endovascular embolization using liquid embolic agents is a safe and effective treatment option for AVMs and dural arteriovenous fistulas. The aim of this study was to assess the degree of artifact inducement by the most frequently used liquid embolic agents in conventional CT in an experimental in vitro model. MATERIALS AND METHODS: Dimethyl-sulfoxide-compatible tubes were filled with the following liquid embolic agents (n = 10, respectively): Onyx 18, all variants of Squid, PHIL 25%, PHIL LV, and n-BCA mixed with iodized oil. After inserting the tubes into a CT imaging phantom, we acquired images. Artifacts were graded quantitatively by the use of Hounsfield units in a donut-shaped ROI using a customized software application that was specifically designed for this study and were graded qualitatively using a 5-point scale. RESULTS: Quantitative and qualitative analyses revealed the most artifacts for Onyx 18 and the least artifacts for n-BCA, PHIL 25%, and PHIL LV. Squid caused more artifacts compared with PHIL, both for the low-viscosity and for the extra-low-viscosity versions (eg, quantitative analysis, Squid 18: mean ± SD, 30.3 ± 9.7 HU versus PHIL 25%: mean ± SD, 10.6 ± 0.8 HU; P < .001). Differences between the standard and low-density variants of Squid were observed only quantitatively for Squid 12. There were no statistical differences between the different concentrations of Squid and PHIL. CONCLUSIONS: In this systematic in vitro analysis investigating the most commonly used liquid embolic agents, relevant differences in CT imaging artifacts could be demonstrated. Ethylene-vinyl alcohol-based liquid embolic agents induced more artifacts compared with liquid embolic agents that use iodine as a radiopaque component.


Asunto(s)
Artefactos , Embolización Terapéutica , Fantasmas de Imagen , Tomografía Computarizada por Rayos X , Dimetilsulfóxido , Combinación de Medicamentos , Embolización Terapéutica/métodos , Técnicas In Vitro , Polivinilos , Tantalio , Tomografía Computarizada por Rayos X/métodos
6.
AJNR Am J Neuroradiol ; 42(2): 319-326, 2021 01.
Artículo en Inglés | MEDLINE | ID: mdl-33303523

RESUMEN

BACKGROUND AND PURPOSE: Stent-assisted treatment techniques can be an effective treatment option for intracranial aneurysms. The aim of this study was to evaluate the periprocedural feasibility and safety of the new LVIS EVO stent for the treatment of intracranial aneurysms. MATERIALS AND METHODS: Patients with intracranial aneurysms treated with the LVIS EVO in 11 European neurovascular centers were retrospectively reviewed. Patient and aneurysm characteristics, procedural parameters, immediate grade of occlusion, and technical and clinical complications were assessed. RESULTS: Fifty-seven patients with 59 aneurysms were treated with the LVIS EVO device; 57.6% of the aneurysms were incidental; 15.3% were acutely ruptured; 15.3% were recanalized or residual aneurysms; and 11.9% were treated for symptoms other than acute hemorrhage. The most frequent aneurysm locations were the middle cerebral artery (25.4%) and the anterior communicating artery (22.0%). The rate of immediate successful deployment was 93.2%. In 6.8% (n = 4) of cases, additional in-stent angioplasty was needed. The immediate complete occlusion rate was 54.2%, while there was a residual aneurysm in 35.6% and a residual neck in 10.2%. Periprocedural technical complications occurred in 7/59 treatments (11.9%; the most frequent technical complication [n = 3] was thrombus formation), which all resolved completely without clinical sequelae. Postprocedural neurologic complications occurred after 4/59 treatments (6.8%; 2 transient ischemic attacks, 1 minor stroke, 1 major stroke), of which only 1 persistent complication was directly related to the procedure (minor stroke in the vascular territory distal to the stent). CONCLUSIONS: The LVIS EVO stent is a safe, feasible device for the treatment of intracranial aneurysms.


Asunto(s)
Procedimientos Endovasculares/instrumentación , Aneurisma Intracraneal/cirugía , Complicaciones Posoperatorias/epidemiología , Stents , Adulto , Anciano , Procedimientos Endovasculares/métodos , Estudios de Factibilidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/etiología , Estudios Retrospectivos , Stents/efectos adversos , Resultado del Tratamiento
7.
PLoS One ; 15(2): e0228578, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32040496

RESUMEN

OBJECTIVES: To compare image quality and metal artifact reduction between virtual monochromatic spectral imaging (VMSI), linearly blended dual-energy (DE) and single-energy (SE) images, each with and without dedicated iterative metal artifact reduction (iMAR) for CT-guided biopsy. MATERIALS AND METHODS: A biopsy trocar was positioned in the liver of six pigs. DE (Sn140/100kVp) and SE (120kVp/200mAs) acquisitions were performed with equivalent dose. From dual-energy datasets DE Q30-3 images and VMSI between 40-180 keV in steps of 20 keV were generated. From SE datasets I30-3 images were reconstructed. All images were reconstructed with and without iMAR. Objective image quality was analyzed applying density measurements at standardized positions (e.g. trocar tip and liver parenchyma adjacent to the trocar tip) and semi-automated threshold based segmentation. Subjective image quality was performed using semi-quantitative scores. Analyses were performed by two observers. RESULTS: At the trocar tip quantitative image analysis revealed significant difference in CT numbers between reconstructions with iMAR compared to reconstructions without iMAR for VMSI at lower keV levels (80 and 100 keV; p = 0.03) and DE (p = 0.03). For liver parenchyma CT numbers were significantly higher in VMSI at high keV compared to low keV (p≤0.01). VMSI at high keV also showed higher CT numbers compared to DE and SE images, though not the level of statistical significance. The best signal-to-noise ratio for VMSI was at 80 keV and comparable to DE and SE. Noise was lowest at 80 keV and lower than in DE and SE. Subjective image quality was best with VMSI at 80 keV regardless of the application of iMAR. iMAR significantly improved image quality at levels of 140 keV and 160 keV. Interreader-agreement was good for quantitative and qualitative analysis. CONCLUSION: iMAR improved image quality in all settings. VMSI with iMAR provided metal artifact reduction and better image quality at 80 keV and thus could improve the accurate positioning in CT-guided needle biopsy. In comparison, DE imaging did not improve image quality compared to SE.


Asunto(s)
Biopsia con Aguja , Procesamiento de Imagen Asistido por Computador/métodos , Biopsia Guiada por Imagen , Hígado/diagnóstico por imagen , Tomografía Computarizada por Rayos X , Algoritmos , Animales , Artefactos , Variaciones Dependientes del Observador , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Imagen Radiográfica por Emisión de Doble Fotón , Relación Señal-Ruido , Porcinos , Vena Cava Inferior/diagnóstico por imagen
8.
AJNR Am J Neuroradiol ; 40(12): 2130-2136, 2019 12.
Artículo en Inglés | MEDLINE | ID: mdl-31753837

RESUMEN

BACKGROUND AND PURPOSE: Endovascular embolization can be an effective treatment for cranial dural arteriovenous fistulas. However, a considerable number of dural arteriovenous fistulas still cannot be treated sufficiently. The purpose of this study was to report our single-center experience of endovascular embolization of dural arteriovenous fistulas with Onyx, including the investigation of the influence of angioarchitectural features on the treatment success. MATERIALS AND METHODS: Clinical data, angioarchitectural features, complications, treatment success (defined as complete symptom remission for low-grade dural arteriovenous fistulas and complete occlusion for high-grade dural arteriovenous fistulas), and occlusion rates were assessed. The influence of various angioarchitectural features (including location, pattern of venous drainage, and quantity and origin of feeding arteries) was investigated using multivariable backward logistic regression. RESULTS: One hundred four patients with 110 dural arteriovenous fistulas were treated in 132 treatment procedures. Treatment success and complete occlusion rates were 81.8% and 90.9%, respectively. After a mean follow-up of 23.6 months, 95.5% of the patients showed complete symptom remission or symptom relief. The overall complication rate was 8.3% (4.5% asymptomatic, 2.3% transient, and 1.5% permanent complications). Logistic regression showed that ≥10 feeding arteries (P = .041) and involvement of the ascending pharyngeal artery (P = .039) significantly lowered the probability of treatment success. Treatment success tended to be lower for low-grade dural arteriovenous fistulas, Cognard type I dural arteriovenous fistulas, and dural arteriovenous fistulas with involvement of dural branches of the internal carotid artery, however without reaching statistical significance in the multivariable model. CONCLUSIONS: The presence of multiple feeding arteries and involvement of the pharyngeal artery negatively influence the treatment success of endovascular embolization of cranial dural arteriovenous fistulas with Onyx.


Asunto(s)
Malformaciones Vasculares del Sistema Nervioso Central/patología , Malformaciones Vasculares del Sistema Nervioso Central/terapia , Embolización Terapéutica/métodos , Polivinilos/uso terapéutico , Adulto , Anciano , Procedimientos Endovasculares/métodos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Resultado del Tratamiento
9.
Nervenarzt ; 89(10): 1179-1194, 2018 Oct.
Artículo en Alemán | MEDLINE | ID: mdl-30215133

RESUMEN

Intracranial vascular malformations range from incidental asymptomatic vascular alterations up to life-threatening vascular disorders. Arteriovenous malformations and dural arteriovenous fistulas are cerebral vascular malformations with arteriovenous shunting of blood. In the majority of cases they are accompanied by an elevated risk of intracerebral hemorrhage and can cause severe symptoms. They can be treated conservatively or interventionally via microneurosurgery, endovascular embolization and radiation therapy. Cavernous malformations, developmental venous anomalies (DVA) and capillary telangiectasia are cerebral vascular malformations without arteriovenous shunting. Cavernous malformations are rarely symptomatic in the form of cerebral hemorrhage, headache or seizures and in such cases an operative treatment can be indicated. The DVA and capillary telangiectasia are usually asymptomatic and do not require treatment.


Asunto(s)
Malformaciones Vasculares del Sistema Nervioso Central , Malformaciones Vasculares del Sistema Nervioso Central/complicaciones , Hemorragia Cerebral/etiología , Hemorragia Cerebral/cirugía , Humanos , Procedimientos Neuroquirúrgicos
10.
AJNR Am J Neuroradiol ; 39(9): 1696-1702, 2018 09.
Artículo en Inglés | MEDLINE | ID: mdl-30093480

RESUMEN

BACKGROUND AND PURPOSE: The type and composition of an embolic agent have a relevant influence on the performance of endovascular embolization. The aim of this study was to investigate a new version of the liquid embolic agent precipitating hydrophobic injectable liquid (PHIL) with extra-low-viscosity in an in vivo embolization model. MATERIALS AND METHODS: Twenty-four embolization procedures were performed in the porcine rete mirabile. Eight embolizations were performed with PHIL 25% low viscosity, Squid 12, and standard PHIL 25%, respectively. Procedure time, required volume of embolic agent, visibility of the embolic agent, embolization control, embolization extent (ie, penetration of the rete mirabile), amount of reflux, and degree of embolization distal to the rete mirabile were assessed. RESULTS: All embolic agents were adequately visible. The embolization extent was not significantly different among the 3 investigated agents; however, there was a tendency toward a higher embolization extent for PHIL 25% low viscosity (median embolization extent: 88% [PHIL 25% low viscosity]; 65% [Squid 12]; 60% [PHIL 25%]; P = .146). The amount of reflux was significantly lower for the extra-low-viscosity agents PHIL 25% low viscosity and Squid 12 compared with the standard PHIL 25% (median reflux distance: 8 mm [PHIL 25% low viscosity]; 6 mm [Squid 12]; 17 mm [PHIL 25%]; P = .011). All other embolization features did not differ among agents. CONCLUSIONS: PHIL 25% low viscosity is a promising liquid embolic agent for endovascular embolization, featuring effective distal penetration, adequate visibility, a low amount of reflux, and good flow control.


Asunto(s)
Embolización Terapéutica/métodos , Polivinilos , Animales , Femenino , Modelos Animales , Porcinos , Viscosidad
11.
AJNR Am J Neuroradiol ; 39(7): 1296-1302, 2018 07.
Artículo en Inglés | MEDLINE | ID: mdl-29724762

RESUMEN

BACKGROUND AND PURPOSE: Sinus-preserving endovascular embolization was described as a promising treatment technique for dural arteriovenous fistulas. Our aim was to report our single-center experience in patients with dural arteriovenous fistulas who were treated with transarterial liquid embolization in combination with transvenous balloon-assisted protection of the affected venous sinus. MATERIALS AND METHODS: A retrospective analysis of a prospectively collected data base was performed. Demographic and clinical data, angiographic features of the dural arteriovenous fistulas, procedural parameters, complications, treatment success, follow-up imaging, and clinical outcome were assessed. RESULTS: Twenty-two patients were treated in 25 procedures. All patients were symptomatic, of whom 81.8% presented with tinnitus; 9.1%, with ocular symptoms; and 9.1%, with headache. Most fistulas were located at the transverse and/or sigmoid sinus. The most frequent fistula type was Cognard IIa+b (40.9%), followed by Cognard I (31.8%) and Cognard IIa (27.3%)/Borden I (59.1%), followed by Borden II (40.9%). The affected sinus could be preserved in all except for 1 patient in whom it was sacrificed in a second treatment procedure by coil embolization. The overall complete occlusion rate was 86.4%. The overall complication rate was 20%, with transient and permanent morbidity and mortality of 8%, 0%, and 0%, respectively. After a mean follow-up of 18 months, most patients (68.2%) achieved complete symptom remission, 27.3% showed symptom relief, and 4.6% had stable symptoms. CONCLUSIONS: Transarterial liquid embolization of dural arteriovenous fistulas in combination with transvenous balloon-assisted protection of the venous sinus is feasible and safe and offers high rates of occlusion and of symptom remission.


Asunto(s)
Oclusión con Balón/métodos , Malformaciones Vasculares del Sistema Nervioso Central/terapia , Embolización Terapéutica/métodos , Procedimientos Endovasculares/métodos , Polivinilos/uso terapéutico , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Resultado del Tratamiento
12.
AJNR Am J Neuroradiol ; 38(7): 1377-1382, 2017 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-28522669

RESUMEN

BACKGROUND AND PURPOSE: Embolization plays a key role in the treatment of arteriovenous malformations. The aim of this study was to evaluate an established (Onyx) and a novel (precipitating hydrophobic injectable liquid [PHIL]) liquid embolic agent in an in vitro AVM model. MATERIALS AND METHODS: An AVM model was integrated into a circuit system. The artificial nidus (subdivided into 28 honeycomb-like sections) was embolized with Onyx 18 (group Onyx; n = 8) or PHIL 25 (group PHIL; n = 8) with different pause times between the injections (30 and 60 seconds, n = 4 per study group) by using a 1.3F microcatheter. Procedure times, number of injections, embolization success (defined as the number of filled sections of the artificial nidus), volume of embolic agent, and frequency and extent of reflux and draining vein embolization were assessed. RESULTS: Embolization success was comparable between Onyx and PHIL. Shorter pause times resulted in a significantly higher embolization success for PHIL (median embolization score, 28 versus 18; P = .011). Compared with Onyx, lower volumes of PHIL were required for the same extent of embolization (median volume per section of the artificial nidus, 15.5 versus 3.6 µL; P < .001). CONCLUSIONS: While the embolization success was comparable for Onyx and PHIL, pause time had a considerable effect on the embolization success in an in vitro AVM model. Compared with Onyx, lower volumes of PHIL were required for the same extent of embolization.


Asunto(s)
Embolización Terapéutica/métodos , Procedimientos Endovasculares/métodos , Malformaciones Arteriovenosas Intracraneales/tratamiento farmacológico , Malformaciones Arteriovenosas Intracraneales/cirugía , Embolia Intracraneal/tratamiento farmacológico , Embolia Intracraneal/cirugía , Polivinilos , Tantalio , Terapia Combinada , Dimetilsulfóxido/uso terapéutico , Combinación de Medicamentos , Femenino , Humanos , Inyecciones , Masculino , Modelos Biológicos , Resultado del Tratamiento
13.
Radiologe ; 57(2): 80-89, 2017 Feb.
Artículo en Alemán | MEDLINE | ID: mdl-28130580

RESUMEN

CLINICAL/METHODICAL ISSUE: In the treatment of localized renal cell carcinoma, the lack of randomization in controlled trials on thermal ablation is a major limitation. The latter leads to significant study bias and it ultimately remains unclear whether the improved overall survival in favor of partial nephrectomy can actually be attributed to the treatment method. STANDARD RADIOLOGICAL METHODS: For T1a (≤4 cm) renal cell carcinoma without lymph node and distant metastases, excellent technical and clinical results have been described after imaging-guided radiofrequency ablation and cryoablation. METHODICAL INNOVATIONS: Low major complication rates, preservation of renal function and three-dimensional confirmation of negative ablation margins (A0 ablation) are the advantages of computed tomography (CT)-guided thermal ablation. PERFORMANCE: According to the results of controlled (non-randomized) trials on T1a renal cell cancer, the cancer-specific survival rates are comparable between ablative and surgical techniques. ACHIEVEMENTS: It is high time for prospective randomized controlled trials to define the actual value of percutaneous thermal ablation and partial nephrectomy in the treatment of T1a renal cell carcinoma. PRACTICAL RECOMMENDATIONS: Apart from localized renal cell carcinoma, angiomyolipoma and oncocytoma can be treated by thermal ablation. Transarterial embolization extends the radiological spectrum for the treatment of renal tumors, either as complementary embolization (e. g. before thermal ablation of T1a and T1b renal cell carcinoma), prophylactic embolization (e. g. angiomyolipoma >6 cm), preoperative embolization (e. g. before laparoscopic partial nephrectomy) or palliative embolization (e. g. in patients with symptomatic macrohematuria due to renal cell carcinoma).


Asunto(s)
Técnicas de Ablación/estadística & datos numéricos , Carcinoma de Células Renales/epidemiología , Carcinoma de Células Renales/cirugía , Neoplasias Renales/epidemiología , Neoplasias Renales/cirugía , Nefrectomía/estadística & datos numéricos , Sesgo , Carcinoma de Células Renales/diagnóstico por imagen , Medicina Basada en la Evidencia , Humanos , Neoplasias Renales/diagnóstico por imagen , Selección de Paciente , Prevalencia , Pronóstico , Factores de Riesgo , Resultado del Tratamiento
14.
Eur J Radiol ; 86: 143-162, 2017 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-28027741

RESUMEN

Percutaneous radiofrequency ablation (RFA) for the treatment of stage I renal cell carcinoma has recently gained significant attention as the now available long-term and controlled data demonstrate that RFA can result in disease-free and cancer-specific survival comparable with partial and/or radical nephrectomy. In the non-controlled single center trials, however, the rates of treatment failure vary. Operator experience and ablation technique may explain some of the different outcomes. In the controlled trials, a major limitation is the lack of adequate randomization. In case reports, original series and overview articles, transarterial embolization (TAE) before percutaneous RFA was promising to increase tumor control and to reduce complications. The purpose of this study was to systematically review the literature on TAE as add-on to percutaneous RFA for renal tumors. Specific data regarding technique, tumor and patient characteristics as well as technical, clinical and oncologic outcomes have been analyzed. Additionally, an overview of state-of-the-art embolization materials and the radiological perspective of advanced image-guided tumor ablation (TA) will be discussed. In conclusion, TAE as add-on to percutaneous RFA is feasible and very effective and safe for the treatment of T1a tumors in difficult locations and T1b tumors. Advanced radiological techniques and technologies such as microwave ablation, innovative embolization materials and software-based solutions are now available, or will be available in the near future, to reduce the limitations of bland RFA. Clinical implementation is extremely important for performing image-guided TA as a highly standardized effective procedure even in the most challenging cases of localized renal tumors.


Asunto(s)
Carcinoma de Células Renales/terapia , Ablación por Catéter/métodos , Neoplasias Renales/terapia , Carcinoma de Células Renales/diagnóstico por imagen , Terapia Combinada/métodos , Embolización Terapéutica/métodos , Femenino , Humanos , Neoplasias Renales/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Nefrectomía/métodos , Radiografía , Cirugía Asistida por Computador , Insuficiencia del Tratamiento , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...