Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 25
Filtrar
1.
Interv Neuroradiol ; 27(3): 339-345, 2021 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-33164617

RESUMEN

BACKGROUND: The novel low-profile p48 flow diverter has been designed to treat aneurysms on small vessels of 1.75-3mm. We report our first clinical experiences. METHODS: Between March 2018-January 2020, 22 patients with 25 aneurysms were treated with the p48 in 3 centers. One patient had 3 aneurysms covered by one p48 and one patient had 2 aneurysms. There were 5 men, 17 women, with a mean age of 55 years (median 59, range 29-73 years). RESULTS: In 25 aneurysms, 24 p48 flow diverters were placed. In 1 patient additional coils were placed in the aneurysm. Procedural vessel rupture by the micro guidewire occurred in 2 patients and vessel rupture during p48 balloon dilatation occurred in 1 patient. Overall, the permanent morbidity rate was 13.6% (3 of 22, 95%CI 3.9-34.2%) and mortality was 4.5% (1 of 22, 95%CI <0.01-23.5%). Most complications were procedure-related and not device-specific. Of 22 patients with 25 aneurysms treated with p48, 18 patients with 20 aneurysms had angiographic follow-up after 5-18 months. Of 19 aneurysms, 10 were occluded and 7 showed a remnant. Two aneurysms were open after 6 months. Three aneurysms were still not occluded after 12, 14, and 18 months and these 3 were retreated. Retreatment rate was 16% (3 of 19) and the adequate occlusion rate was 90% (17 of 19). CONCLUSIONS: Treatment of aneurysms in small-caliber vessels with the p48 is feasible and effective but is not without complications. More data is needed to establish indications, safety, and efficacy more accurately.


Asunto(s)
Embolización Terapéutica , Procedimientos Endovasculares , Aneurisma Intracraneal , Adulto , Anciano , Angiografía , Femenino , Humanos , Aneurisma Intracraneal/diagnóstico por imagen , Aneurisma Intracraneal/terapia , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Stents , Resultado del Tratamiento
3.
J Belg Soc Radiol ; 99(2): 65-73, 2015 Dec 30.
Artículo en Inglés | MEDLINE | ID: mdl-30039110

RESUMEN

Epistaxis or nosebleed is relatively common in the general population. Depending on the location of the bleeding in the nasal cavity, epistaxis can be divided in two types: anterior or posterior type. The anterior type is far more frequent, often self-limiting and, if needed, is relatively easy treatable. Posterior type epistaxis is rare and more likely to require medical attention. The cornerstone of the conservative therapy of posterior epistaxis is nasal packing. Only in patients with persistent or recurrent epistaxis, endovascular intervention or surgery is indicated. Both treatment options have a similar success and complication rate, but endovascular treatment, if feasible, has several advantages above surgical treatment. The choice of procedure should be made on a patient-to-patient basis, taking several parameters into account. In this pictorial essay we present an overview of the relevant radiological anatomy and a review of various causes of epistaxis, with the emphasis on the endovascular treatment.

4.
JBR-BTR ; 97(1): 17-20, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-24765765

RESUMEN

Developmental venous anomaly (DVA) is probably the most common anomaly of the intracranial vasculature. DVAs consist of multiple, radially oriented dilated medullary veins that converge into a transcerebral vein. We describe the imaging findings of this vascular anomaly in different patients and the role of different imaging modalities.


Asunto(s)
Venas Cerebrales/anomalías , Venas Cerebrales/patología , Malformaciones Arteriovenosas Intracraneales/diagnóstico , Imagen por Resonancia Magnética/métodos , Adulto , Diagnóstico Diferencial , Femenino , Humanos , Malformaciones Arteriovenosas Intracraneales/patología , Angiografía por Resonancia Magnética/métodos , Masculino , Persona de Mediana Edad
5.
Ann Cardiol Angeiol (Paris) ; 62(6): 442-5, 2013 Dec.
Artículo en Francés | MEDLINE | ID: mdl-24119773

RESUMEN

Coronary-cameral fistulas are usually congenital, rarely acquired; the complication of this anomaly with ventricular pseudoaneurysm is exceptional. We report a new case of acquired coronary-cameral fistula, occurred in a patient who had received a bypass graft and who had suffered from angina 1 year after the surgery. On computed tomography coronary angiography, the fistula seems to communicate the first diagonal to a left ventricle pseudoaneurysm. Embolization of the fistula and filling of the pseudoaneurysm by neurocoil were successfully performed. The clinical and angiographic control after 3 months showed symptoms improvement and absence of recanalization of the fistula.


Asunto(s)
Aneurisma Falso/diagnóstico por imagen , Puente de Arteria Coronaria/efectos adversos , Enfermedad de la Arteria Coronaria/etiología , Fístula/etiología , Atrios Cardíacos , Ventrículos Cardíacos/patología , Anciano , Aneurisma Falso/terapia , Enfermedad de la Arteria Coronaria/diagnóstico , Embolización Terapéutica/métodos , Fístula/diagnóstico , Fístula/terapia , Estudios de Seguimiento , Ventrículos Cardíacos/diagnóstico por imagen , Humanos , Masculino , Radiografía , Resultado del Tratamiento , Fístula Vascular/etiología
8.
JBR-BTR ; 93(4): 189-92, 2010.
Artículo en Inglés | MEDLINE | ID: mdl-20957889

RESUMEN

The authors report the case of a 21-year-old man who suffered from a blunt abdominal trauma. Initial imaging revealed a liver laceration at the right lobe, a perirenal hematoma of the right kidney and a hematoma of the right adrenal gland. Follow-up MDCT-scan on day 10 after admission showed at the arterial-phase contrast-enhanced study perfusion alterations and two hepatic pseudoaneurysms. The diagnosis of pseudoaneurysm was confirmed and treated angiographically with superselective coil embolization. A follow-up CT-scan on day 17 showed at a nontreated area an arterioportal shunt and a wedge-shaped transient hepatic parenchymal enhancement. This was confirmed angiographically and subsequently treated with coil embolization.


Asunto(s)
Aneurisma Falso/diagnóstico por imagen , Fístula Arteriovenosa/diagnóstico por imagen , Arteria Hepática/lesiones , Tomografía Computarizada por Rayos X/métodos , Accidentes por Caídas , Aneurisma Falso/etiología , Aneurisma Falso/terapia , Angiografía , Fístula Arteriovenosa/etiología , Fístula Arteriovenosa/terapia , Embolización Terapéutica , Arteria Hepática/diagnóstico por imagen , Humanos , Masculino , Adulto Joven
9.
Eur Spine J ; 19 Suppl 1: S8-17, 2010 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-19727855

RESUMEN

Traumatic injuries of the spine and spinal cord are common and potentially devastating lesions. We present a comprehensive overview of the classification of vertebral fractures, based on morphology (e.g., wedge, (bi)concave, or crush fractures) or on the mechanism of injury (flexion-compression, axial compression, flexion-distraction, or rotational fracture-dislocation lesions). The merits and limitations of different imaging techniques are discussed, including plain X-ray films, multi-detector computed tomography (MDCT), and magnetic resonance imaging (MRI) for the detection. There is growing evidence that state-of-the-art imaging techniques provide answers to some of the key questions in the management of patients with spine and spinal cord trauma: is the fracture stable or unstable? Is the fracture recent or old? Is the fracture benign or malignant? In summary, we show that high-quality radiological investigations are essential in the diagnosis and management of patients with spinal trauma.


Asunto(s)
Diagnóstico por Imagen/métodos , Traumatismos de la Médula Espinal/diagnóstico , Fracturas de la Columna Vertebral/diagnóstico , Traumatismos Vertebrales/diagnóstico , Diagnóstico por Imagen/tendencias , Humanos , Imagen por Resonancia Magnética/métodos , Imagen por Resonancia Magnética/normas , Pronóstico , Radiografía/métodos , Radiografía/normas , Traumatismos de la Médula Espinal/clasificación , Traumatismos de la Médula Espinal/fisiopatología , Fracturas de la Columna Vertebral/clasificación , Fracturas de la Columna Vertebral/fisiopatología , Traumatismos Vertebrales/clasificación , Traumatismos Vertebrales/fisiopatología , Tomografía Computarizada por Rayos X/métodos , Tomografía Computarizada por Rayos X/normas , Índices de Gravedad del Trauma , Heridas y Lesiones/clasificación , Heridas y Lesiones/diagnóstico , Heridas y Lesiones/fisiopatología
10.
Ultrasound Med Biol ; 34(2): 196-207, 2008 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-17935871

RESUMEN

Automated segmentation approaches for the left ventricle (LV) in 3-D echocardiography (3DE) often rely on manual initialization. So far, little effort has been put into automating the initialization procedure to get to a fully automatic segmentation approach. We propose a fully automatic method for the detection of the LV long axis (LAX) and the mitral valve plane (MVP) over the full cardiac cycle, for the initialization of segmentation algorithms in 3DE. Our method exploits the cyclic motion of the LV and therefore detects salient structures in a time-continuous way. Probabilities to candidate LV center points are assigned through a Hough transform for circles. The LV LAX is detected by combining dynamic programming detections on these probabilities in 3-D and 2D + time to obtain a time continuous solution. Subsequently, the mitral valve plane is detected in a projection of the data on a plane through the previously detected LAX. The method easily adjusts to different acquisition routines and combines robustness with good accuracy and low computational costs. Automatic detection was evaluated using patient data acquired with the fast rotating ultrasound (FRU) transducer (n=11 patients) and with the Philips Sonos 7500 ultrasound system (Philips Medical Systems, Andover, MA, USA), with the X4 matrix transducer (n=14 patients). For the FRU-transducer data, the LAX was estimated with a distance error of 2.85+/-1.70 mm (mean+/-SD) and an angle of 5.25+/-3.17 degrees; the mitral valve plane was estimated with a distance of -1.54+/-4.31 mm. For the matrix data, these distances were 1.96+/-1.30 mm with an angle error of 5.95+/-2.11 and -1.66+/-5.27 mm for the mitral valve plane. These results confirm that the method is very suitable for automatic detection of the LV LAX and MVP. It provides a basis for further automatic exploration of the LV and could therefore serve as a replacement of manual initialization of 3-D segmentation approaches.


Asunto(s)
Ecocardiografía Tridimensional/métodos , Cardiopatías/diagnóstico por imagen , Ventrículos Cardíacos/diagnóstico por imagen , Interpretación de Imagen Asistida por Computador/métodos , Válvula Mitral/diagnóstico por imagen , Humanos , Variaciones Dependientes del Observador
12.
AJNR Am J Neuroradiol ; 28(3): 555-60, 2007 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-17353335

RESUMEN

PURPOSE: To prospectively assess the short-term clinical outcome of patients with subacute or chronic painful osteoporotic vertebral compression fractures (VCF) treated with percutaneous vertebroplasty (PV) compared with optimal pain medication (OPM). METHODS: Randomization of patients in 2 groups: treatment by PV or OPM. After 2 weeks, patients from the OPM arm could change therapy to PV. Patients were evaluated 1 day and 2 weeks after treatment. Visual analog score (VAS) for pain and analgesic use were assessed before, and 1 day and 2 weeks after start of treatment. Quality of Life Questionnaire of the European Foundation for Osteoporosis (QUALEFFO) and Roland-Morris Disability (RMD) questionnaire scores were assessed before and 2 weeks after start of treatment. Follow-up scores in patients requesting PV treatment after 2 weeks OPM treatment were compared with scores during their OPM period. RESULTS: Eighteen patients treated with PV compared with 16 patients treated with OPM had significantly better VAS and used less analgesics 1 day after treatment. Two weeks after treatment, the mean VAS was less but not significantly different in patients treated with OPM, whereas these patients used significantly less analgesics and had better QUALEFFO and RMD scores. Scores in the PV arm were influenced by occurrence of new VCF in 2 patients. After 2 weeks OPM, 14 patients requested PV treatment. All scores, 1 day and 2 weeks after PV, were significantly better compared with scores during conservative treatment. CONCLUSION: Pain relief and improvement of mobility, function, and stature after PV is immediate and significantly better in the short term compared with OPM treatment.


Asunto(s)
Analgésicos/uso terapéutico , Cementos para Huesos/uso terapéutico , Fracturas por Compresión/terapia , Procedimientos Ortopédicos , Dolor/tratamiento farmacológico , Fracturas de la Columna Vertebral/terapia , Enfermedad Aguda , Anciano , Anciano de 80 o más Años , Enfermedad Crónica , Estudios Cruzados , Femenino , Estudios de Seguimiento , Fracturas por Compresión/etiología , Humanos , Inyecciones , Masculino , Persona de Mediana Edad , Osteoporosis/complicaciones , Dolor/etiología , Estudios Prospectivos , Fracturas de la Columna Vertebral/etiología , Resultado del Tratamiento
13.
AJNR Am J Neuroradiol ; 27(7): 1579-85, 2006 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-16908585

RESUMEN

BACKGROUND AND PURPOSE: Presence of bone marrow edema (BME) in osteoporotic vertebral compression fractures (VCF) detected by MR imaging as selection criterion for percutaneous vertebroplasty (PV) is speculative. To clarify significance of BME in VCF, we assessed pain response after PV in patients with VCF with full BME versus patients with VCF with absent BME. METHODS: From a cohort of patients with painful VCF selected for PV, pain response in 14 patients with absent BME in VCF was prospectively compared with pain response in 31 patients with full BME in VCF. Pain was evaluated before PV and at 1 and 3 months after PV with visual analog scores and analgesics used. Back pain in general and at treated vertebral levels was assessed. RESULTS: Pain decrease after PV at treated levels was observed in 10 (71%) patients with absent BME in VCF at both follow-up periods and in 29 (94%) patients with full BME 1 month after PV and 30 (97%) at 3 months after PV. Differences between the groups were significant (P = .04 at 1 month; P = .01 at 3 months). Pain response was not affected by other patient or imaging characteristics. General back pain after PV was comparable in both groups after PV (P = .08 at 1 month; P = .4 at 3 months). CONCLUSION: Pain decrease after PV in patients with VCF is more frequently observed when full BME is present. Because 71% of patients with VCF with absent BME responded favorably on pain, PV should not be withheld based on absence of BME alone.


Asunto(s)
Enfermedades de la Médula Ósea/complicaciones , Edema/complicaciones , Fracturas por Compresión/cirugía , Osteoporosis/cirugía , Dimensión del Dolor , Procedimientos de Cirugía Plástica/métodos , Fracturas de la Columna Vertebral/cirugía , Columna Vertebral/cirugía , Anciano , Anciano de 80 o más Años , Analgésicos/uso terapéutico , Dolor de Espalda/fisiopatología , Dolor de Espalda/cirugía , Cementos para Huesos/uso terapéutico , Estudios de Cohortes , Femenino , Estudios de Seguimiento , Humanos , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Polimetil Metacrilato/uso terapéutico , Estudios Prospectivos
14.
Ultrasonics ; 44 Suppl 1: e131-4, 2006 Dec 22.
Artículo en Inglés | MEDLINE | ID: mdl-16843511

RESUMEN

A number of recent studies have indicated the potential of ultrasound contrast agent imaging at high ultrasound frequencies. However, the acoustic properties of microbubbles at frequencies above 10 MHz remain poorly understood at present. In this study we characterize the high frequency attenuation properties of (1) BR14, (2) BR14 that has been mechanically filtered (1 and 2 microm pore sizes) to exclude larger bubbles, and (3) the micron to submicron agent BG2423. A narrowband pulse-echo substitution method is employed with a series of four transducers covering the frequency range from 2 to 50 MHz. For BR14, attenuation decreases rapidly from 2 to 10 MHz and then more gradually from 10 to 50 MHz. For 2 microm filtration, the attenuation peaks between 10 and 15 MHz. For 1 microm filtration, attenuation continues to rise until 50 MHz. The agent BG2423 exhibits a diffuse attenuation peak in the range of 15-25 MHz and remains high until 50 MHz. These results demonstrate a strong influence of bubble size on high frequency attenuation curves, with bubble diameters of 1-2 microm and below having more pronounced acoustic activity at frequencies above 10 MHz.


Asunto(s)
Cápsulas/química , Cápsulas/efectos de la radiación , Fluorocarburos/química , Fluorocarburos/efectos de la radiación , Interpretación de Imagen Asistida por Computador/métodos , Microburbujas , Fosfolípidos/química , Fosfolípidos/efectos de la radiación , Ultrasonografía/métodos , Relación Dosis-Respuesta en la Radiación , Aumento de la Imagen/métodos , Lípidos/química , Lípidos/efectos de la radiación , Ensayo de Materiales , Tamaño de la Partícula , Dosis de Radiación , Ondas de Radio
15.
AJNR Am J Neuroradiol ; 27(5): 983-8, 2006 May.
Artículo en Inglés | MEDLINE | ID: mdl-16687528

RESUMEN

BACKGROUND AND PURPOSE: Little is known about the evolution of bone marrow edema (BME) in osteoporotic vertebral compression fractures (VCF) after percutaneous vertebroplasty (PV) or about its relation with relief of pain. In this study, we prospectively assessed changes in BME with MR imaging at 3, 6, and 12 months after PV and related changes in BME with pain evolution and analgesic use over time. METHODS: BME percentage was assessed in 64 patients after PV of 89 VCF with serial MR imaging follow-up at 3, 6, and 12 months. Pain was assessed before PV and at every follow-up interval by visual analog scale for pain and type of analgesic used. Relation between changes in BME and pain evolution was assessed in a subgroup of 31 patients with a single treated VCF and neither new VCF at follow-up nor pain at another untreated level. RESULTS: BME gradually decreased over time. At 1 year after PV, 29% of treated VCF still demonstrated BME. Once BME disappeared, it did not return. Pain relief was most striking the first 3 months after PV and remained constant thereafter. There was no relation between relief of pain and extent, presence, or absence of BME after PV. CONCLUSION: A gradual decrease of BME in osteoporotic VCF treated with PV is apparent during 12 months of MR imaging follow-up. Decrease of BME is unrelated to relief of pain.


Asunto(s)
Enfermedades de la Médula Ósea/etiología , Edema/etiología , Fracturas por Compresión/etiología , Fracturas por Compresión/terapia , Osteoporosis/complicaciones , Fracturas de la Columna Vertebral/etiología , Fracturas de la Columna Vertebral/terapia , Anciano , Anciano de 80 o más Años , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Resultado del Tratamiento
17.
Ultrasonics ; 42(1-9): 739-43, 2004 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-15047376

RESUMEN

Improved endocardial border delineation with the application of contrast agents should allow for less complex and faster tracing algorithms for left ventricular volume analysis. We developed a fast rotating phased array transducer for 3D imaging of the heart with harmonic capabilities making it suitable for contrast imaging. In this study the feasibility of 3D harmonic contrast imaging is evaluated in vitro. A commercially available tissue mimicking flow phantom was used in combination with Sonovue. Backscatter power spectra from a tissue and contrast region of interest were calculated from recorded radio frequency data. The spectra and the extracted contrast to tissue ratio from these spectra were used to optimize the excitation frequency, the pulse length and the receive filter settings of the transducer. Frequencies ranging from 1.66 to 2.35 MHz and pulse lengths of 1.5, 2 and 2.5 cycles were explored. An increase of more than 15 dB in the contrast to tissue ratio was found around the second harmonic compared with the fundamental level at an optimal excitation frequency of 1.74 MHz and a pulse length of 2.5 cycles. Using the optimal settings for 3D harmonic contrast recordings volume measurements of a left ventricular shaped agar phantom were performed. Without contrast the extracted volume data resulted in a volume error of 1.5%, with contrast an accuracy of 3.8% was achieved. The results show the feasibility of accurate volume measurements from 3D harmonic contrast images. Further investigations will include the clinical evaluation of the presented technique for improved assessment of the heart.


Asunto(s)
Ecocardiografía Tridimensional/métodos , Medios de Contraste , Estudios de Factibilidad , Técnicas In Vitro , Fantasmas de Imagen , Fosfolípidos , Hexafluoruro de Azufre , Transductores
18.
Ned Tijdschr Geneeskd ; 147(32): 1549-53, 2003 Aug 09.
Artículo en Holandés | MEDLINE | ID: mdl-12942845

RESUMEN

OBJECTIVE: To describe the technique of percutaneous vertebroplasty and the short-term results in patients with symptomatic, osteoporotic vertebral compression fractures. DESIGN: Prospective follow-up study. METHOD: In a pilot-study to evaluate the short-term safety and effectiveness of percutaneous vertebroplasty, 18 consecutive patients with a total of 33 osteoporotic thoracic or lumbar vertebral compression fractures were treated from October 2001 to June 2002 with a follow-up of 3-6 months. The indication for treatment was a symptomatic, therapy-resistant osteoporotic vertebral compression fracture. Percutaneous vertebroplasty was performed under radiographic control, after previous intraossal venography, using bone cement mixed with barium sulphate. Post-procedural follow-up consisted of radiological evaluation with conventional thoracolumbar X-rays and MRI scans, and interviews of the patients. RESULTS: Percutaneous vertebroplasty was technically successful in 31 of 33 vertebral fractures (94%), and in 16 of 18 patients (89%). One patient with extreme venous contrast leakage could not be treated. Sixteen patients had less or no pain after treatment. One patient retained thoracolumbar back pain after inadequate cementations and refused further treatment. None of the patients reported aggravation of symptoms following the procedure. Contrast leakage was absent in 18 vertebrae. In 8 vertebrae there was contrast leakage to paravertebral veins. In three of these cases the leakage was so severe that embolisation was performed, with success in one case. In 13 vertebrae, cement leakage to intervertebral and paravertebral spaces and pedicular cement spurs were seen, without clinical consequences. Immediately after the procedure and during follow-up there were no clinically relevant complications. CONCLUSION: Percutaneous vertebroplasty was a technically feasible treatment in these patients with symptomatic, therapy-resistant, osteoporotic vertebral fractures. The first short-term results were comparable with results in the literature. A prospective randomised intervention study will be needed to compare percutaneous vertebroplasty with optimal conservative treatment.


Asunto(s)
Fracturas Espontáneas/cirugía , Vértebras Lumbares/lesiones , Osteoporosis/complicaciones , Fracturas de la Columna Vertebral/cirugía , Vértebras Torácicas/lesiones , Anciano , Anciano de 80 o más Años , Dolor de Espalda/cirugía , Cementación , Femenino , Estudios de Seguimiento , Fracturas Espontáneas/etiología , Humanos , Vértebras Lumbares/cirugía , Masculino , Persona de Mediana Edad , Proyectos Piloto , Complicaciones Posoperatorias/epidemiología , Estudios Prospectivos , Seguridad , Fracturas de la Columna Vertebral/etiología , Vértebras Torácicas/cirugía , Resultado del Tratamiento
19.
Ned Tijdschr Geneeskd ; 147(32): 1553-9, 2003 Aug 09.
Artículo en Holandés | MEDLINE | ID: mdl-12942846

RESUMEN

OBJECTIVE: To determine the effectiveness and safety of percutaneous vertebroplasty for the treatment of osteoporotic vertebral compression fractures as published in the scientific literature. DESIGN: Literature review. METHOD: Medline and the Cochrane library were searched with the terms 'percutaneous vertebroplasty', 'vertebral compression fractures', 'osteoporotic' and 'osteoporosis'. Criteria for inclusion were: (a) the studies had to have been published in the period January 1985-August 2002, (b) the study population had to include at least 10 patients, (c) the patients had to have been treated with percutaneous vertebroplasty, and (d) the diagnosis had to have been 'osteoporotic vertebral compression fracture'. RESULTS: Twelve studies met the inclusion criteria. Pain relief was seen in 60%-100% of the patients within the first 24 hours and this result improved to 78-100% in the long term (maximum 4 years). The complications immediately after the procedure were related to cement leakages and were mostly of no clinical consequence. Serious complications such as pulmonary embolism were rare. In the long term, percutaneous vertebroplasty was associated with an increased risk of fractures in the adjacent vertebrae. CONCLUSION: Percutaneous vertebroplasty seems to be effective and safe in the treatment of osteoporotic vertebral compression fractures. A prospective randomised intervention study has, however, not yet been performed. For the time being, percutaneous vertebroplasty should be reserved for carefully selected patients in whom conservative therapy has not produced results.


Asunto(s)
Fracturas de la Columna Vertebral/cirugía , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Fracturas Espontáneas/cirugía , Humanos , MEDLINE , Masculino , Metaanálisis como Asunto , Persona de Mediana Edad , Osteoporosis/complicaciones , Dolor/cirugía , Complicaciones Posoperatorias/epidemiología , Seguridad , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...