Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Sci Rep ; 10(1): 10061, 2020 Jun 17.
Artículo en Inglés | MEDLINE | ID: mdl-32555402

RESUMEN

An amendment to this paper has been published and can be accessed via a link at the top of the paper.

2.
Anal Chem ; 92(7): 4908-4916, 2020 04 07.
Artículo en Inglés | MEDLINE | ID: mdl-31909981

RESUMEN

Functional screenings in droplet-based microfluidics require the analysis of various types of activities of individual cells. When screening for enzymatic activities, the link between the enzyme of interest and the information-baring molecule, the DNA, must be maintained to relate phenotypes to genotypes. This linkage is crucial in directed evolution experiments or for the screening of natural diversity. Micro-organisms are classically used to express enzymes from nucleic acid sequences. However, little information is available regarding the most suitable expression system for the sensitive detection of enzymatic activity at the single-cell level in droplet-based microfluidics. Here, we compare three different expression systems for l-asparaginase (l-asparagine amidohydrolase, EC 3.5.1.1), an enzyme of therapeutic interest that catalyzes the conversion of l-asparagine to l-aspartic acid and ammonia. We developed three expression vectors to produce and localize l-asparaginase (l-ASNase) in E. coli either in the cytoplasm, on the surface of the inner membrane (display), or in the periplasm. We show that the periplasmic expression is the most optimal strategy combining both a good yield and a good accessibility for the substrate without the need for lysing the cells. We suggest that periplasmic expression may provide a very efficient platform for screening applications at the single-cell level in microfluidics.


Asunto(s)
Asparaginasa/metabolismo , Escherichia coli/genética , Técnicas Analíticas Microfluídicas , Asparaginasa/análisis , Escherichia coli/metabolismo , Tamaño de la Partícula , Propiedades de Superficie
3.
Microsyst Nanoeng ; 4: 33, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-31057921

RESUMEN

Fluorescence-activated droplet sorting (FADS) is one of the most important features provided by droplet-based microfluidics. However, to date, it does not allow to compete with the high-throughput multiplexed sorting capabilities offered by flow cytometery. Here, we demonstrate the use of a dielectrophoretic-based FADS, allowing to sort up to five different droplet populations simultaneously. Our system provides means to select droplets of different phenotypes in a single experimental run to separate initially heterogeneous populations. Our experimental results are rationalized with the help of a numerical model of the actuation of droplets in electric fields providing guidelines for the prediction of sorting designs for upscaled or downscaled microsystems.

4.
Sci Rep ; 7(1): 1366, 2017 05 02.
Artículo en Inglés | MEDLINE | ID: mdl-28465615

RESUMEN

Droplet-based microfluidics is extensively and increasingly used for high-throughput single-cell studies. However, the accuracy of the cell counting method directly impacts the robustness of such studies. We describe here a simple and precise method to accurately count a large number of adherent and non-adherent human cells as well as bacteria. Our microfluidic hemocytometer provides statistically relevant data on large populations of cells at a high-throughput, used to characterize cell encapsulation and cell viability during incubation in droplets.


Asunto(s)
Ensayos Analíticos de Alto Rendimiento/métodos , Técnicas Analíticas Microfluídicas , Análisis de la Célula Individual/métodos , Proliferación Celular , Supervivencia Celular , Escherichia coli/aislamiento & purificación , Células HL-60 , Ensayos Analíticos de Alto Rendimiento/instrumentación , Humanos , Dispositivos Laboratorio en un Chip , Microfluídica , Análisis de la Célula Individual/instrumentación
5.
Biomicrofluidics ; 9(3): 034101, 2015 May.
Artículo en Inglés | MEDLINE | ID: mdl-26015838

RESUMEN

Droplet-based microfluidic technologies are powerful tools for applications requiring high-throughput, for example, in biochemistry or material sciences. Several systems have been proposed for the high-throughput production of monodisperse emulsions by parallelizing multiple droplet makers. However, these systems have two main limitations: (1) they allow the use of only a single disperse phase; (2) they are based on multiple layer microfabrication techniques. We present here a pipette-and-play solution offering the possibility of manipulating simultaneously 10 different disperse phases on a single layer device. This system allows high-throughput emulsion production using aqueous flow rates of up to 26 ml/h (>110 000 drops/s) leading to emulsions with user-defined complex chemical composition. We demonstrate the multiplex capabilities of our system by measuring the kinetics of ß-galactosidase in droplets using nine different concentrations of a fluorogenic substrate.

6.
Sci Rep ; 4: 4787, 2014 Apr 30.
Artículo en Inglés | MEDLINE | ID: mdl-24781785

RESUMEN

Music is a form of art interweaving people of all walks of life. Through subtle changes in frequencies, a succession of musical notes forms a melody which is capable of mesmerizing the minds of people. With the advances in technology, we are now able to generate music electronically without relying solely on physical instruments. Here, we demonstrate a musical interpretation of droplet-based microfluidics as a form of novel electronic musical instruments. Using the interplay of electric field and hydrodynamics in microfluidic devices, well controlled frequency patterns corresponding to musical tracks are generated in real time. This high-speed modulation of droplet frequency (and therefore of droplet sizes) may also provide solutions that reconciles high-throughput droplet production and the control of individual droplet at production which is needed for many biochemical or material synthesis applications.

7.
Soft Matter ; 10(17): 3066-76, 2014 May 07.
Artículo en Inglés | MEDLINE | ID: mdl-24695668

RESUMEN

We designed, developed and characterized a microfluidic method for the measurement of surfactant adsorption kinetics via interfacial tensiometry on a microfluidic chip. The principle of the measurement is based on the deformability of droplets as a response to hydrodynamic forcing through a series of microfluidic expansions. We focus our analysis on one perfluoro surfactant molecule of practical interest for droplet-based microfluidic applications. We show that although the adsorption kinetics is much faster than the kinetics of the corresponding pendant drop experiment, our droplet-based microfluidic system has a sufficient time resolution to obtain quantitative measurement at the sub-second time-scale on nanoliter droplet volumes, leading to both a gain by a factor of ∼10 in time resolution and a downscaling of the measurement volumes by a factor of ∼1000 compared to standard techniques. Our approach provides new insight into the adsorption of surfactant molecules at liquid-liquid interfaces in a confined environment, relevant to emulsification, encapsulation and foaming, and the ability to measure adsorption and desorption rate constants.


Asunto(s)
Éteres/química , Compuestos de Flúor/química , Fluorocarburos/química , Microfluídica , Compuestos Organofosforados/química , Polietilenglicoles/química , Tensoactivos/química , Agua/química , Adsorción , Etanol/química , Cinética
8.
Appl Phys Lett ; 103(20): 203704, 2013 Nov 11.
Artículo en Inglés | MEDLINE | ID: mdl-32095020

RESUMEN

We demonstrate the use of a hybrid microfluidic-micro-optical system for the screening of enzymatic activity at the single cell level. Escherichia coli ß-galactosidase activity is revealed by a fluorogenic assay in 100 pl droplets. Individual droplets containing cells are screened by measuring their fluorescence signal using a high-speed camera. The measurement is parallelized over 100 channels equipped with microlenses and analyzed by image processing. A reinjection rate of 1 ml of emulsion per minute was reached corresponding to more than 105 droplets per second, an analytical throughput larger than those obtained using flow cytometry.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA