PLoS One ; 19(5): e0300451, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38739643

RESUMEN

PURPOSE: The aim of this study was to evaluate the imaging capabilities of Butterfly iQ with conventional ophthalmic (piezoelectric) ultrasound (COU) for ophthalmic imaging. METHODS: Custom phantom molds were designed and imaged with Butterfly iQ and COU to compare spatial resolution capabilities. To evaluate the clinical imaging performance of Butterfly iQ and COU, a survey containing pathological conditions from human subjects, imaged with both Butterfly iQ and COU probes, was given to three retina specialists and graded on image detail, resolution, quality, and diagnostic confidence on a ten-point Likert scale. Kruskal-Wallis analysis was performed for survey responses. RESULTS: Butterfly iQ and COU had comparable capabilities for imaging small axial and lateral phantom features (down to 0.1 mm) of high and low acoustic reflectivity. One of three retina specialists demonstrated a statistically significant preference for COU related to resolution, detail, and diagnostic confidence, but the remaining graders showed no significant preference for Butterfly iQ or COU across all sample images presented. CONCLUSION: The emergence of portable ultrasound probes offers an affordable alternative to COU technologies with comparable qualitative imaging resolution down to 0.1 mm. These findings suggest the value to further study the use of portable ultrasound systems and their utility in routine eye care.


Asunto(s)
Fantasmas de Imagen , Ultrasonografía , Humanos , Ultrasonografía/métodos , Ultrasonografía/instrumentación , Oftalmopatías/diagnóstico por imagen
2.
Respir Med Case Rep ; 49: 102000, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38576860

RESUMEN

Coccidioidomycosis is a fungal infection primarily Endemic in the Southwest United States. Disseminated Coccidioidomycosis is a life-threatening variant that mainly occurs in an immunocompromised host. This report describes an unusual presentation of disseminated Coccidioidomycosis in an immunocompetent individual. The patient was admitted with a subacute cough, progressively worsening shortness of breath, significant weight loss, nodular skin lesions in upper extremities, and acute hypoxemic respiratory failure. Chest imaging revealed extensive nodularity and mass-like lesions. What sets this case apart is the significant endotracheal and endobronchial involvement, which mimicked metastatic lung cancer. The diagnosis was confirmed through serology and bronchoscopy biopsy. This case underscores the critical importance of considering detailed travel history and maintaining a high index of suspicion for fungal infections in patients with endobronchial lesions, particularly in regions where Coccidioidomycosis is endemic.

3.
Ophthalmol Sci ; 4(3): 100450, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38327842

RESUMEN

Purpose: To investigate the use of super-resolution imaging techniques to enable telepathology using low-cost commercial cameras. Design: Experimental study. Participants: A total of 139 ophthalmic pathology slides obtained from the Ophthalmic Pathology service at the University of California, Irvine. Methods: Denoising Diffusion Probabilistic Model (DDPM) was developed to predict super-resolution pathology slide images from low-resolution inputs. The model was pretrained using 150 000 images randomly sampled from the ImageNet dataset. Patch aggregation was used to generate large images with DDPM. The performance of DDPM was evaluated against that of generative adversarial networks (GANs) and Robust UNet, which were also trained on the same dataset. Main Outcome Measures: The performance of models trained to generate super-resolution output images from low-resolution input images can be evaluated by using the mean squared error (MSE) and Structural Similarity Index Measure (SSIM), as well as subjective grades provided by expert pathologist graders. Results: In total, our study included 110 training images, 9 validation images, and 20 testing images. The objective performance scores were averaged over patches generated from 20 test images. The DDPM-based approach with pretraining produced the best results, with an MSE score of 1.35e-5 and an SSIM score of 0.8987. A qualitative analysis of super-resolution images was conducted by expert 3 pathologists and 1 expert ophthalmic microscopist, and the average accuracy of identifying the correct ground truth images ranged from 25% to 70% (with an average accuracy of 46.5%) for widefield images and 25% to 60% (with an average accuracy of 38.25%) for individual patches. Conclusions: The DDPM-based approach with pretraining is assessed to be effective at super-resolution prediction for ophthalmic pathology slides both in terms of objective and subjective measures. The proposed methodology is expected to decrease the reliance on costly slide scanners for acquiring high-quality pathology slide images, while also streamlining clinical workflow and expanding the scope of ophthalmic telepathology. Financial Disclosures: Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.

4.
medRxiv ; 2023 Apr 21.
Artículo en Inglés | MEDLINE | ID: mdl-37131650

RESUMEN

Introduction: Clinical tools are neither standardized nor ubiquitous to monitor volumetric or morphological changes in the periorbital region and ocular adnexa due to pathology such as oculofacial trauma, thyroid eye disease, and the natural aging process. We have developed a low-cost, three dimensionally printed PHotogrammetry for Automated CarE (PHACE) system to evaluate three-dimensional (3D) measurements of periocular and adnexal tissue. Methods: The PHACE system uses two Google Pixel 3 smartphones attached to automatic rotating platforms to image a subject's face through a cutout board patterned with registration marks. Photographs of faces were taken from many perspectives by the cameras placed on the rotating platform. Faces were imaged with and without 3D printed hemispheric phantom lesions (black domes) affixed on the forehead above the brow. Images were rendered into 3D models in Metashape (Agisoft, St. Petersburg, Russia) and then processed and analyzed in CloudCompare (CC) and Autodesk's Meshmixer. The 3D printed hemispheres affixed to the face were then quantified within Meshmixer and compared to their known volumes. Finally, we compared digital exophthalmometry measurements with results from a standard Hertel exophthalmometer in a subject with and without an orbital prosthesis. Results: Quantification of 3D printed phantom volumes using optimized stereophotogrammetry demonstrated a 2.5% error for a 244µL phantom, and 7.6% error for a 27.5µL phantom. Digital exophthalmometry measurements differed by 0.72mm from a standard exophthalmometer. Conclusion: We demonstrated an optimized workflow using our custom apparatus to analyze and quantify oculofacial volumetric and dimensions changes with a resolution of 244µL. This apparatus is a low-cost tool that can be used in clinical settings to objectively monitor volumetric and morphological changes in periorbital anatomy.

5.
medRxiv ; 2023 Apr 21.
Artículo en Inglés | MEDLINE | ID: mdl-37131657

RESUMEN

Purpose: To compare a custom Photogrammetry for Anatomical CarE (PHACE) system with other cost-effective 3-dimensional (3D) facial scanning systems to objectively characterize morphology and volume of periorbital and adnexal anatomy. Methods: The imaging systems evaluated include the low-cost custom PHACE system and commercial software product for the iPhone called Scandy Pro (iScandy) application (Scandy, USA), and the mid-priced Einscan Pro 2X (Shining3D Technologies, China) device and Array of Reconstructed Cameras 7 (ARC7) facial scanner (Bellus3D, USA). Imaging was performed on a manikin facemask and humans with various Fitzpatrick scores. Scanner attributes were assessed using mesh density, reproducibility, surface deviation, and emulation of 3D printed phantom lesions affixed above the superciliary arch (brow line). Results: The Einscan served as a reference for lower cost imaging systems because it qualitatively and quantitatively renders facial morphology with the highest mesh density, reproducibility (0.13 ± 0.10 mm), and volume recapitulation (approximately 2% of 33.5 µL). Compared to the Einscan, the PHACE system (0.35 ± 0.03 mm, 0.33 ± 0.16 mm) demonstrated non-inferior mean accuracy and reproducibility root mean square (RMS) compared to the iScandy (0.42 ± 0.13 mm, 0.58 ± 0.09 mm), and significantly more expensive ARC7 (0.42 ± 0.03 mm, 0.26 ± 0.09 mm). Similarly, the PHACE system showed non-inferior volumetric modeling when rendering a 124 µL phantom lesion compared to the iScandy and more costly ARC7 (mean percent difference from the Einscan: 4.68 ± 3.73%, 9.09 ± 0.94%, and 21.99 ± 17.91% respectively). Conclusions: The affordable PHACE system accurately measures periorbital soft tissue as well as other established mid-cost facial scanning systems. Additionally, the portability, affordability, and adaptability of PHACE can facilitate widespread adoption of 3D facial anthropometric technology as an objective measurement tool in ophthalmology.

6.
PLoS One ; 17(4): e0265185, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35385502

RESUMEN

Humans perceive light in the visible spectrum (400-700 nm). Some night vision systems use infrared light that is not perceptible to humans and the images rendered are transposed to a digital display presenting a monochromatic image in the visible spectrum. We sought to develop an imaging algorithm powered by optimized deep learning architectures whereby infrared spectral illumination of a scene could be used to predict a visible spectrum rendering of the scene as if it were perceived by a human with visible spectrum light. This would make it possible to digitally render a visible spectrum scene to humans when they are otherwise in complete "darkness" and only illuminated with infrared light. To achieve this goal, we used a monochromatic camera sensitive to visible and near infrared light to acquire an image dataset of printed images of faces under multispectral illumination spanning standard visible red (604 nm), green (529 nm) and blue (447 nm) as well as infrared wavelengths (718, 777, and 807 nm). We then optimized a convolutional neural network with a U-Net-like architecture to predict visible spectrum images from only near-infrared images. This study serves as a first step towards predicting human visible spectrum scenes from imperceptible near-infrared illumination. Further work can profoundly contribute to a variety of applications including night vision and studies of biological samples sensitive to visible light.


Asunto(s)
Visión de Colores , Aprendizaje Profundo , Algoritmos , Humanos , Rayos Infrarrojos , Redes Neurales de la Computación
7.
J Ophthalmic Vis Res ; 17(1): 130-134, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35194503

RESUMEN

PURPOSE: To illustrate the regression of a metastatic lesion through ophthalmic imaging and correlating findings with standard chest imaging and treatment with osimertinib, an oral chemotherapy agent specific to Epidermal Growth Factor Receptor + Non-small Cell Lung Cancer (EGFR+ NSCLC). CASE REPORT: A 63-year-old Asian male presented to ophthalmology with a complaint of left blurry vision. Initial ophthalmic exam revealed a choroidal lesion and imaging results highlighted a spiculated lung mass with brain and bony metastases. Osimertinib was chosen for its specificity and ability to cross the blood-brain barrier. Follow-up ophthalmic and radiographic imaging were repeated over the course of treatment. CONCLUSION: After the initiation of osimertinib, ophthalmic and computed tomography imaging highlighted the regression of the ocular metastatic disease and primary malignancy, respectively.Osimertinib is an effective first-line treatment of EGFR+ NSCLC and corresponding metastatic sites. Additionally, ophthalmic imaging can be used to monitor general response to chemotherapy agents when ocular metastasis is identified.

8.
Cornea ; 40(8): 1048-1054, 2021 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-33369939

RESUMEN

PURPOSE: To describe cases in which netarsudil ophthalmic solution 0.02% precipitated reversible, reticular cystic epithelial edema. METHODS: A retrospective case review at the Brooklyn Veteran's Association Hospital of patients with corneal stromal edema that were treated with netarsudil and subsequently developed cystic epithelial edema. RESULTS: Four male patients with a mean age of 72 ± 8.0 years developed a reticular, honeycomb-like pattern of epithelial edema located in the interpalpebral and inferior cornea. In 3 of 4 patients, epithelial edema arose within 1 month compared with 2 months in 1 patient. New epithelial cysts did not correlate with worsening central corneal thickness and best spectacle-corrected visual acuity in every patient, which was likely due to the location of the cysts. Two of 4 patients developed increased central corneal thickness with worsening best spectacle-corrected visual acuity. In comparison, 1 patient had improvement in both parameters, whereas 1 patient had no significant change. In all cases, there was resolution of the epithelial cysts after discontinuation of netarsudil. CONCLUSIONS: Although rho-kinase inhibitors have been suggested to improve endothelial function, we have documented worsening epithelial cysts in a subset of patients with pre-existing corneal edema. These effects of netarsudil were transient and resolved after discontinuing treatment within 2 weeks in most patients. We hypothesize that the incidence of this adverse finding is more common than previously believed. Nevertheless, large-scale studies are needed to accurately report on the incidence and clinical significance of this novel finding.


Asunto(s)
Benzoatos/administración & dosificación , Edema Corneal/tratamiento farmacológico , Epitelio Corneal/patología , Presión Intraocular/efectos de los fármacos , Agudeza Visual , beta-Alanina/análogos & derivados , Anciano , Anciano de 80 o más Años , Edema Corneal/patología , Edema Corneal/fisiopatología , Epitelio Corneal/efectos de los fármacos , Humanos , Masculino , Soluciones Oftálmicas/administración & dosificación , Estudios Retrospectivos , Microscopía con Lámpara de Hendidura , beta-Alanina/administración & dosificación , Quinasas Asociadas a rho/antagonistas & inhibidores