Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
J Esthet Restor Dent ; 2024 Aug 20.
Artículo en Inglés | MEDLINE | ID: mdl-39165048

RESUMEN

OBJECTIVE: To analyze and compare the impact of acidic media on the surface characteristics of highly filled flowable resin-based composites. MATERIALS AND METHODS: Two hundred fifty-six specimens were divided into four groups: GUF (G-aenial Universal Flo), GUI (G-aenial Universal Injectable), TEF (Tetric EvoFlow), and FSF (Filtek Supreme Flowable Restorative). Surface characteristics were analyzed before (T0) and after specimens immersion in different media, such as gastric juice (GJ), fizzy drink (FD), citric juice (CJ), or artificial saliva (AS), for 9 h (T1) and 18 h (T2). The analyses included surface roughness (SR) measurements, where average roughness (Ra) was obtained, scanning electron microscopy (SEM) analysis, and surface hardness (SH) evaluation, with Vickers numbers (HV) reported. The differences in values among groups/subgroups within the same stage were assessed using two-way ANOVA and Tukey's post hoc test, whereas repeated measures ANOVA with Bonferroni post hoc test was performed to compare the changes in values through the stages. Data were presented as mean ± standard deviation (SD). RESULTS: At T0, GUI and GUF revealed lower Ra values (p < 0.05), more evenness in SEM micrographs, and higher HV values (p < 0.05) than FSF and TEF. At T1 and T2, specimens of all groups/subgroups demonstrated an increase in Ra and a decrease in HV compared with T0 (p < 0.05), as well as the changes in surface morphology on SEM micrographs. The lowest Ra and highest HV values were observed in GUI group, in contrast to FSF group, and in specimens immersed in GJ. CONCLUSIONS: GUI revealed lower SR and higher SH compared to GUF and FSF both before and after exposure to acidic media. The presence of acidic media, especially GJ, significantly increases SR and decreases SH of tested materials. CLINICAL SIGNIFICANCE: Information on the changes in the surface characteristics of highly filled resin-based composites after exposure to acidic media may be essential for the longevity of restorations like composite veneers fabricated from these materials.

2.
Odontology ; 2024 May 05.
Artículo en Inglés | MEDLINE | ID: mdl-38705962

RESUMEN

The aim of this research was to determine if there are differences in early bacterial adhesion among CAD/CAM dental materials after 24 h exposure in the oral environment. One hundred twenty specimens were prepared according to the manufacturer's recommendations and divided into six groups: RBC (resin-based composite), PMMA (polymethyl methacrylate), PEEK (polyether ether ketone), ZP (zirconia polished), ZG (zirconia glazed), and cobalt-chromium alloy (CoCr alloy). Twenty healthy participants were instructed to carry an intraoral device with six specimens, one per group, for 24 h. Thereafter, real-time polymerase chain reaction (qPCR) and scanning electron microscopy (SEM) analyses enabled quantification and 2D view of biofilm formed on the specimens' surfaces. Kruskal-Wallis test and Dunn's post hoc analysis were used for inter-group comparison and data were presented as median (minimum-maximum). RBC specimens accumulated less bacteria, in comparison with ZG (p = 0.017) and PEEK specimens (p = 0.030), that dominated with the highest amount of adhered bacterial biofilm. PMMA, CoCr, and ZP specimens adhered more bacteria than RBC (p > 0.05), and less than ZG (p > 0.05) and PEEK (p > 0.05). The bacterial number varied considerably among participants. The obtained results enable a closer view into the susceptibility of CAD/CAM materials to microorganisms during the presence in the oral environment, which can be beneficial for a proper selection of these materials for a variety of dental restorations.

3.
Polymers (Basel) ; 15(9)2023 Apr 29.
Artículo en Inglés | MEDLINE | ID: mdl-37177285

RESUMEN

Dental polymers are now available as monolithic materials which can be readily used in computer-aided design and computer-aided manufacturing (CAD/CAM) systems. Despite possessing numerous advantages over conventionally produced polymers, the polymers produced by either of these systems fail to exhibit immunity to surface microbial adhesion when introduced into the oral environment, leading to the development of oral diseases. The aim of this study was to analyze the biofilm formation of six microorganisms from the oral cavity and its correlation to the surface characteristics of CAD/CAM dental polymers. A total of ninety specimens were divided into three groups: resin-based composite, polymethyl methacrylate, and polyether ether ketone. The experimental procedure included surface roughness and water contact angle measurements, colony forming unit counting, and scanning electron microscopy analysis of biofilm formed on the surface of the tested materials. The data were analyzed using the Kruskal-Wallis test, with a Dunn's post hoc analysis, and one way analysis of variance, with a Tukey's post hoc test; the correlation between the measurements was tested using Spearman's correlation coefficient, and descriptive statistics were used to present the data. Despite using the same manufacturing procedure, as well as the identical manufacturer's finishing and polishing protocols, CAD/CAM dental polymers revealed significant differences in surface roughness and water contact angle, and the increased values of both parameters led to an increase in biofilm formation on the surface of the materials. The CAD/CAM resin-based composite showed the lowest number of adhered microorganisms compared to CAD/CAM polymethyl methacrylate and CAD/CAM polyether ether ketone.

4.
J Esthet Restor Dent ; 35(6): 917-926, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37039335

RESUMEN

OBJECTIVE: To evaluate the effect of different finishing and polishing procedures on surface roughness and microbial adhesion and viability of Streptococcus mutans on novel highly-filled composites for injectable mold technique. MATERIALS AND METHODS: One hundred sixty specimens were divided into four material groups: FSF (Filtek Supreme Flowable Restorative), TE (Tetric EvoFlow), GUI (G-aenial Universal Injectable) and GUF (G-aenial Universal Flo). Within each group, specimens were split regarding finishing and polishing (F/P) procedures into: SLD (Sof-Lex Discs), SLS (Sof-Lex Spirals), OG (OneGloss) and PG (PoGo). Surface roughness was analyzed using profilometer (Ra and Rz) and scanning electron microscopy (SEM) and Strep. mutans biofilm formation was analyzed using colony forming unit (CFU) and cell viability assay. Two-way analysis of variance (ANOVA) followed by Tukey's post hoc test were used for comparison among groups, Pearson's coefficient was applied for the correlation between Ra and CFU/ml and all data were presented as mean ± SD. RESULTS: Both materials and F/P procedures affect Ra, Rz and Strep. mutans CFU/ml values (p ≤ 0.05). Considering the Ra and Rz, GUI and GUF revealed lower values, compared to FSF and TE and SLD and SLS revealed lower values, compared to OG and PG. Considering the Strep. mutans CFU/ml and viability, GUI and TE presented lower values, compared to GUF and FSF and SLD and SLS presented lower values, compared to OG and PG. Moderate positive correlation was found between Ra and CFU/ml (r = 0.552). CONCLUSIONS: The smoothest surfaces possess GUI and GUF, among materials and SLD and SLS, among F/P procedures. GUI adhered the lowest amount of Strep. mutans, due to the smoothest surfaces. FSF and GUF revealed the highest amount of Strep. mutans, due to bis-GMA, bis-MEPP and TEGDMA in their composition. CLINICAL SIGNIFICANCE: The findings of the present study may be beneficial for the proper selection of highly-filled composites and an adequate finishing and polishing procedure when performing the injectable mold composite resin veneer technique.


Asunto(s)
Pulido Dental , Restauración Dental Permanente , Restauración Dental Permanente/métodos , Pulido Dental/métodos , Propiedades de Superficie , Ensayo de Materiales , Resinas Compuestas , Bisfenol A Glicidil Metacrilato
5.
Eur J Oral Sci ; 131(1): e12911, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36585796

RESUMEN

The aim of the study was to investigate the adhesion and viability of Streptococcus oralis and Candida albicans under in vitro conditions on CAD/CAM framework materials for implant-supported hybrid prostheses. Twenty-nine specimens were prepared from each of three different materials: ZR (zirconia), PEEK (polyether ether ketone) and CoCr4 (CoCr4 alloy). The experimental part included surface roughness (SR) and contact angle of water (CAW) measurements, followed by colony forming unit (CFU), cell viability assay and scanning electron microscopy (SEM) analyses of Strep. oralis and C. albicans biofilms on the materials' surfaces. Kruskal-Wallis and one-way analysis of variance (ANOVA) tests were used for differences between materials, and the correlation between measurements was estimated using Spearman's correlation coefficient. PEEK specimens revealed higher SR, CAW and CFU mean values, than ZR and CoCr4 specimens. Strong positive correlation was found between SR and CFU and between CAW and CFU for both microbial species. Cell viability assay revealed similar values for both species across materials. Higher numbers of Strep. oralis and C. albicans on PEEK specimens confirm the impact of the higher surface roughness and contact angle values on the microbial adhesion and describes PEEK as less desirable than ZR and CoCr4 from microbiological aspect.


Asunto(s)
Implantes Dentales , Propiedades de Superficie , Biopelículas , Polímeros , Ensayo de Materiales
6.
J Esthet Restor Dent ; 34(7): 1132-1141, 2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-35997320

RESUMEN

OBJECTIVE: To determine if there are any differences in surface characteristics (surface roughness and contact angle) among different CAD/CAM materials indicated for fabricating implant-supported restorations, following all the material preparation protocols provided by the manufacturer. MATERIALS AND METHODS: One-hundred forty-four specimens were divided into six groups: RBC (resin-based composite), PMMA (polymethyl methacrylate), PEEK (polyether ether ketone), ZP (zirconia polished), ZG (zirconia glazed) and CoCr4 (CoCr4 alloy). The experimental part included surface roughness (SR) and contact angle of water (WCA) analyses, fulfilled with Atomic Force Microscopy (AFM) and Scanning Electron Microscopy (SEM) view of surface topography. The data were analyzed using Kruskal-Wallis test with a Dunn's post hoc analysis, the correlation between measurements was tested using Spearman's rank correlation coefficient and all data were presented as mean ± SD. RESULTS: ZG specimens were significantly rougher compared to other groups (p ≤ 0.05). The WCA measurements revealed significantly lower mean values in ZG group (p ≤ 0.05), contrary to PEEK and CoCr4 , where significantly higher mean values were observed, compared to other groups (p ≤ 0.05). There exist a moderate negative correlation between the SR and WCA (ρ = -0.41). AFM 3D and SEM 2D images presented more or less heterogeneous surface of all materials. CONCLUSIONS: There were statistically significant differences in surface roughness and contact angle among tested material groups. Moderate negative correlation was found between surface roughness and contact angle of tested material groups. CLINICAL SIGNIFICANCE: The study gives us a better understanding of influence of physicochemical characteristics of investigated materials on their surface properties and provides useful knowledge for future researches in a view of material's behavior under in vivo conditions, when it comes to a question of features related to surface quality, such as microbial adhesion, corrosion, wear, biocompatibility and esthetics.


Asunto(s)
Diseño Asistido por Computadora , Polimetil Metacrilato , Aleaciones , Benzofenonas , Éteres , Cetonas , Ensayo de Materiales , Polietilenglicoles/química , Polímeros , Propiedades de Superficie , Agua , Circonio
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA