Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Histol Histopathol ; 29(3): 353-60, 2014 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-24190861

RESUMEN

In this study, we describe a new semi-quantitative method for measuring the extent of bleeding in pathohistological tissue samples. To test our novel method, we recruited 120 female patients in their first trimester of pregnancy and divided them into three groups of 40. Group I was the control group, in which no dilation was applied. Group II was an experimental group, in which dilation was performed using classical mechanical dilators. Group III was also an experimental group, in which dilation was performed using a hydraulic dilator. Tissue samples were taken from the patients' cervical canals using a Novak's probe via energetic single-step curettage prior to any dilation in Group I and after dilation in Groups II and III. After the tissue samples were prepared, light microscopy was used to obtain microphotographs at 100x magnification. The surfaces affected by bleeding were measured in the microphotographs using the Autodesk AutoCAD 2009 program and its "polylines" function. The lines were used to mark the area around the entire sample (marked A) and to create "polyline" areas around each bleeding area on the sample (marked B). The percentage of the total area affected by bleeding was calculated using the formula: N = Bt x 100 / At where N is the percentage (%) of the tissue sample surface affected by bleeding, At (A total) is the sum of the surfaces of all of the tissue samples and Bt (B total) is the sum of all the surfaces affected by bleeding in all of the tissue samples. This novel semi-quantitative method utilizes the Autodesk AutoCAD 2009 program, which is simple to use and widely available, thereby offering a new, objective and precise approach to estimate the extent of bleeding in tissue samples.


Asunto(s)
Cuello del Útero , Dilatación/efectos adversos , Dilatación/instrumentación , Hemorragia/diagnóstico , Adulto , Femenino , Hemorragia/etiología , Humanos , Interpretación de Imagen Asistida por Computador , Embarazo , Primer Trimestre del Embarazo , Adulto Joven
3.
J BUON ; 11(2): 241-4, 2006.
Artículo en Inglés | MEDLINE | ID: mdl-17318979

RESUMEN

Two cases of female patients with solitary fibrous tumor of the pleura are described. Chest radiography and computed tomography showed the presence of a giant mass with inhomogeneous density in the hemithorax in both cases. Transthoracic needle biopsy of the masses showed benign fibrous tissue. Both patients underwent thoracotomy. The tumors arose from the visceral pleura, were peduncular, appeared well-circumscribed with exterior surface smooth, firm and multinodular. The size of tumors were 16x11x6 cm and 15x11x4.5 cm, weighed 650 g and 573 g and both were successfully resected. The pathological diagnosis was benign solitary fibrous tumor of the pleura. Seven years after the operations the clinical condition and chest radiography are normal in both women.


Asunto(s)
Fibroma/patología , Neoplasias Pleurales/patología , Adulto , Femenino , Humanos , Persona de Mediana Edad