1.
Rev Sci Instrum ; 79(10): 10E702, 2008 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-19044520

RESUMEN

Two-dimensional phase contrast imaging (2D) installed on the large helical device (LHD) is a unique diagnostic for local turbulence measurements. A 10.6 microm infrared CO(2) laser and 6x8 channel HgCdTe 2D detector are used. The length of the scattering volume is larger than plasma size. However, the asymmetry of turbulence structure with respect to the magnetic field and magnetic shear make local turbulence measurements possible. From a 2D image of the integrated fluctuations, the spatial cross-correlation function was estimated using time domain correlation analysis, then, the integrated 2D k-spectrum is obtained using maximum entropy method. The 2D k-spectrum is converted from Cartesian coordinates to cylindrical coordinates. Finally, the angle in cylindrical coordinate is converted to flux surface labels. The fluctuation profile over almost the entire plasma diameter can be obtained at a single moment. The measurable k-region can be varied by adjusting the detection optics. Presently, k=0.1-1.0 mm(-1) can be measured which is expected region of ion temperature gradient modes and trapped electron mode in LHD. The spatial resolution is 10%-50% of the minor radius.

2.
Rev Sci Instrum ; 79(10): 10E724, 2008 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-19044541

RESUMEN

High k turbulence, up to 30 cm(-1), can be measured using the two dimensional CO2 laser phase contrast imaging system on LHD. Recent hardware improvements and experimental results are presented. Precise control over the lens positions in the detection system is necessary because of the short depth of focus for high k modes. Remote controllable motors to move optical elements were installed, which, combined with measurements of the response to ultrasound injection, allowed experimental verification and shot-to-shot adjustment of the object plane. Strong high k signals are observed within the first 100-200 ms after the initial electron cyclotron heating (ECH) breakdown, in agreement with gyrotron scattering. During later times in the discharge, the entire k spectrum shifts to lower values (although the total amplitude does not change significantly), and the weaker high k signals are obscured by leakage of low k components at low frequency, and detector noise, at high frequency.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...