Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Intervalo de año de publicación
1.
Artículo en Chino | WPRIM (Pacífico Occidental) | ID: wpr-822613

RESUMEN

Objective@#To study the effect of the edentulous arch with implant supported telescopic overdenture. @*Methods@#Fifteen patients with edentulous jaws underwent telescopic overdenture restoration. A total of 26 prostheses were fabricated (11 in the upper jaws, 15 in the lower jaws) with 104 placed implants. The secondary crown was fabricated by wax-lost cast method. Clinical examination and radiographs were conducted. Changes in the marginal bone level around the implants were evaluated by radiograph. The satisfaction level of complete denture and implant-supported overdenture were compared. The mean follow-up time was 32 months (range 6-60 months).@*Results@#Twenty-six prostheses showed better stability, maintenance and occlusion. There were statistical differences between complete denture and implant-supported overdenture in comfort level and chewing function. 1 mm bone lost was found in two patients after 4 years. No implant was lost during the loading time. @*Conclusion @#The preliminary clinical results of this research showed that implant supported telescopic overdentures were reliable for edentulous patients.

2.
Hua Xi Kou Qiang Yi Xue Za Zhi ; 27(6): 629-32, 2009 Dec.
Artículo en Chino | MEDLINE | ID: mdl-20077898

RESUMEN

OBJECTIVE: To study the influence of two slot size brackets on torque control when teeth interacted in the same arch. METHODS: After the upper arch was aligned and leveled in Typodont study, the inclinations of upper teeth 5 +/- 5 were measured when 0.457 2 mm x 0.635 0 mm OPA-K brackets and 0.558 8 mmx0.711 2 mm OPA-K brackets were filled with 0.431 8 mm x 0.635 0 mm stainless steel wire. This experiment was duplicated 10 times. The inclin of each tooth were transformed to the absolute values of the torque play angle psi by computing program, and paired-t test was used. RESULTS: The two kinds of slot size brackets were different with statistical significance on torque control. When the brackets were filled with 0.431 8 mm x 0.635 0 mm stainless steel wire, the absolute values of the angle psi in 0.558 8 mm x 0.711 2 mm and 0.457 2 mm x 0.635 0 mm slot size brackets were 6.140 degrees +/- 3.758 degrees and 2.608 degrees +/- 1.479 degrees respectively, and the average difference of that between the two slot size brackets was 3.532 degrees. The absolute values of the angle psi in the upper left and right canine brackets were 2.560 degrees +/- 2.605 degrees, 4.230 degrees +/- 2.817 degrees, 1.260 degrees +/- 0.747 degrees and 2.070 degrees +/- 0.663 degrees respectively, and average differences between them were smaller than that in the other teeth. CONCLUSION: There was difference between the two kinds of slot size brackets on torque control, and 0.457 2 mm x 0.635 0 mm slot size bracket controls torque better when filled with the same size wire. In this study, the teeth interaction in the same arch probably caused the result that the difference of two slot size brackets on torque control was less than the study results of the theory calculations and material studys before.


Asunto(s)
Diseño de Aparato Ortodóncico , Torque , Humanos , Soportes Ortodóncicos , Acero Inoxidable , Diente
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...