Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
J Contemp Brachytherapy ; 14(3): 260-267, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-36199991

RESUMEN

Purpose: Novel hybrid Venezia applicator enables intracavitary and interstitial brachytherapy (BT) for locally advanced cervical cancer. However, the method to determine the optimal interstitial needle number, position, and depth using this applicator is unknown. Therefore, we aimed to establish a method for reliable needle optimization. Material and methods: We produced a template model of the Venezia applicator with whole needles, and acquired computed tomography (CT) images (template CT). Using this template CT as a map, clinicians could define interstitial needle's insertion route in advance. During treatment, we first placed tandem and ovoid, and acquired a CT (tandem + ovoid CT). This was fused to the template CT by matching the contour of applicators with high accuracy. Then, we determined the optimal interstitial needle number, position, and depth to fit high-risk clinical target volume (HR-CTV) and avoid organs at risk (OARs) on the fused CT (intra pre-plan). Next, we re-inserted the tandem and ovoids with interstitial needle into patient's uterus and vagina. We inserted the optimized interstitial needle using insertion tool of optimal depth immediately following the applicator insertion. Lastly, a real-time treatment planning CT was performed, followed by planning and treatment. Results: We achieved a good dose distribution of Venezia applicator BT using intra pre-plan method to optimize the number of interstitial needles, position, and depth. Conclusions: This novel intra pre-plan method of interstitial needle optimization using template CT fusion provides high reproducibility, efficiency, and safety for patients with cervical cancer treated with brachytherapy using Venezia applicator.

2.
Lung Cancer ; 173: 75-82, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-36156324

RESUMEN

OBJECTIVES: Locoregional recurrence of non-small cell lung cancer (NSCLC) occurs even among patients with stage I disease, as a result of tumor proliferative activity. The aim of this study was to evaluate the clinical reliability of a new rapid immunohistochemistry (IHC) technique for assessing malignant potential through detection of tumoral Ki-67 expression. MATERIALS AND METHODS: The rapid IHC method uses non-contact alternating current (AC) mixing to achieve more rapid/stable staining within 20 min during surgery. First, to investigate the association between clinical outcomes and tumoral Ki-67 labeling with rapid IHC, 21 pairs of surgical patients treated between 2012 and 2020 for pStage IA1-3 NSCLC with/without recurrence were retrospectively reviewed. Second, 40 frozen section (FS) samples in patients with NSCLC for whom radical surgery was planned between April 2021 and February 2022 were deemed eligible for comparison of the clinical performance of conventional IHC and intraoperative rapid Ki-67 IHC with FS. RESULTS: Detection of tumoral Ki-67 expression using rapid IHC with formalin-fixed, paraffin-embedded (FFPE) blocks was significantly associated with clinical outcomes in R0 pStage IA NSCLC surgical patients, including overall and recurrence-free survival (P = 0.0043 and P < 0.0001, respectively). Levels of Ki-67 expression among resectable NSCLC patients detected using rapid IHC with FS significantly correlated with those detected using conventional FFPE-IHC (p < 0.001). An intraoperative cut-off of > 7.5 % tumor cell Ki-67 positivity accurately predicted pathological stage more advanced than IA3 [P = 0.0185, Odds ratio = 20.477, 95 % confidence interval (CI): 1.660-252.55]. CONCLUSION: Rapid Ki-67 IHC with AC mixing could potentially serve as a clinical tool for intraoperative determination of tumor malignancy status. The present study suggests that segmentectomy for early small NSCLCs is oncologically safe and a reasonable alternative to lobectomy, but only when there is adequate intraoperative selection for primary tumors with low-grade malignancy, which could be verified using intraoperative rapid Ki-67 IHC with FS.


Asunto(s)
Carcinoma de Pulmón de Células no Pequeñas , Neoplasias Pulmonares , Humanos , Inmunohistoquímica , Neoplasias Pulmonares/diagnóstico , Neoplasias Pulmonares/cirugía , Neoplasias Pulmonares/tratamiento farmacológico , Carcinoma de Pulmón de Células no Pequeñas/diagnóstico , Carcinoma de Pulmón de Células no Pequeñas/cirugía , Antígeno Ki-67 , Reproducibilidad de los Resultados , Estudios Retrospectivos , Recurrencia Local de Neoplasia , Formaldehído/uso terapéutico
5.
Thorac Cancer ; 12(8): 1187-1194, 2021 04.
Artículo en Inglés | MEDLINE | ID: mdl-33650770

RESUMEN

BACKGROUND: Immune checkpoint inhibitors (ICIs) are a promising advance in the treatment of patients with lung cancer. However, each ICI has been tested with an independently designed companion diagnostic assay that is based on a unique antibody. Consequently, the different trial-validated programmed death ligand 1 (PD-L1) immunohistochemistry (IHC) assays should not be considered interchangeable. Our aim was to compare the performance of each available PD-L1 antibody for its ability to accurately measure PD-L1 expression and to investigate the possibility of harmonization across antibodies through the use of a new rapid IHC system, which uses noncontact alternating current (AC) mixing to achieve more stable staining. METHODS: First, 58 resected non-small cell lung cancer (NSCLC) specimens were stained using three PD-L1 IHC assays (28-8, SP142, and SP263) to assess the harmonization achieved with AC mixing IHC. Second, specimens from 27 patients receiving ICIs for postoperative recurrent NSCLC were stained using the same IHC method to compare the clinical performance of ICIs to PD-L1 scores. All patients received a tumor proportion score (TPS) with the 22C3 companion diagnostic test. RESULTS: Better staining was achieved with the new AC mixing IHC method than the conventional IHC in PD-L1-positive cases, and the interchangeability of some combinations of assays was increased in PD-L1-positive. In addition, AC mixing IHC provided more appropriate overall response rates for ICIs in all assays. CONCLUSIONS: Stable PD-L1 IHC driven by AC mixing helped to improve TPS scoring and patient selection for ICIs through interchangeable assays.


Asunto(s)
Anticuerpos Monoclonales/uso terapéutico , Neoplasias Pulmonares/tratamiento farmacológico , Anciano , Anticuerpos Monoclonales/farmacología , Femenino , Humanos , Inmunohistoquímica , Masculino , Persona de Mediana Edad , Pronóstico
6.
Cancer Med ; 10(2): 586-594, 2021 01.
Artículo en Inglés | MEDLINE | ID: mdl-33280268

RESUMEN

BACKGROUND: Human epidermal growth factor receptor 2-in situ hybridization (HER2-ISH) is widely approved for diagnostic, prognostic biomarker testing of formalin-fixed paraffin-embedded tissue blocks. However, cytologic ISH analysis has a potential advantage in tumor samples such as pleural effusion and ascites that are difficult to obtain the histological specimens. Our aim was to evaluate the clinical reliability of a novel rapid cytologic HER2 fluorescence ISH protocol (rapid-CytoFISH). MATERIALS AND METHODS: Using a new device, we applied a high-voltage/frequency, noncontact alternating current electric field to tissue imprints and needle rinses, which mixed the probe within microdroplets as the voltage was switched on and off (AC mixing). Cytologic samples (n = 143) were collected from patients with immunohistochemically identified HER2 breast cancers. The specimens were then tested using standard dual-color ISH using formalin-fixed paraffin-embedded tissue (FFPE-tissue DISH) for HER2-targeted therapies, CytoFISH, and rapid-CytoFISH (completed within 4 h). RESULTS: All 143 collected cytologic specimens (50 imprinted cytology specimens from resected tumors and 93 liquid-based cytology specimens from needle rinses) were suitable for FISH analysis. The HER2/chromosome enumeration probe (CEP) 17 ratios did not significantly differ between FFPE-tissue DISH and either CytoFISH protocol. Based on HER2 scoring criteria, we found 95.1% agreement between FFPE-tissue DISH and CytoFISH (Cohen's kappa coefficient = 0.771 and 95% confidence interval (CI): 0.614-0.927). CONCLUSION: CytoFISH could potentially serve as a clinical tool for prompt determination of HER2 status in breast cancer cytology. Rapid-CytoFISH with AC mixing will enable cancer diagnoses and HER2 status to be determined on the same day a patient comes to a clinic or hospital.


Asunto(s)
Neoplasias de la Mama/diagnóstico , Carcinoma Ductal de Mama/diagnóstico , Carcinoma Lobular/diagnóstico , Citodiagnóstico/métodos , Electricidad , Hibridación Fluorescente in Situ/métodos , Receptor ErbB-2/metabolismo , Adulto , Anciano , Anciano de 80 o más Años , Neoplasias de la Mama/metabolismo , Carcinoma Ductal de Mama/metabolismo , Carcinoma Lobular/metabolismo , Pruebas Diagnósticas de Rutina , Femenino , Estudios de Seguimiento , Humanos , Persona de Mediana Edad , Pronóstico
7.
Thorac Cancer ; 11(12): 3547-3554, 2020 12.
Artículo en Inglés | MEDLINE | ID: mdl-33075198

RESUMEN

BACKGROUND: Although lobectomy is considered the standard surgery for any non-small cell lung cancer (NSCLC), recent evidence indicates that for early NSCLCs segmentectomy may be equally effective. For segmentectomy to be oncologically safe, however, adequate intraoperative lymph node staging is essential. The aim of this study was to compare the results of a new rapid-IHC system to the HE analysis for intraoperative nodal diagnosis in lung cancer patients considered for segmentectomy. METHODS: This retrospective study analyzed the pathological reports from NSCLC resections over a six-year period between 2014 and 2020. Using a new device for rapid-IHC, we applied a high-voltage, low-frequency alternating current (AC) field, which mixes the antipancytokeratin antibody as the voltage is switched on/off. Rapid-IHC can provide a nodal diagnosis within 20 minutes. RESULTS: Frozen sections from 106 resected lymph nodes from 70 patients were intraoperatively evaluated for metastasis. Of those, five nodes were deemed positive based on both HE staining and rapid-IHC. In addition, rapid-IHC alone detected isolated tumor cells in one hilar lymph node. Three cStage IA patients with nodal metastasis detected with HE staining and rapid-IHC received complete lobectomies. Five-year relapse-free survival and overall survival among patients receiving segmentectomy with rapid-IHC were 88.77% and 88.79%, respectively. CONCLUSIONS: Rapid-IHC driven by AC mixing is simple, highly accurate, and preserves nodal tissue for subsequent tests. This system can be used effectively for intraoperative nodal diagnosis. Rapid immunohistochemistry based on alternating-current field mixing (completed within 20 minutes) is simple and highly accurate. This system will assist clinicians when making intraoperative diagnoses of lymph node metastasis and deciding upon the appropriate surgical procedure in segmentectomy for lung cancer. KEY POINTS: SIGNIFICANT FINDINGS OF THE STUDY: Rapid immunohistochemistry driven by alternating-current field mixing (completed within 20 minutes intraoperatively) is simple, highly accurate, and preserves lymph node tissue for subsequent pathological examination, including molecular assessments. WHAT THIS STUDY ADDS: Segmentectomy for lung cancer is oncologically safe, but only when there is adequate intraoperative node staging. Rapid immunohistochemistry will assist clinicians when making intraoperative nodal diagnoses.


Asunto(s)
Carcinoma de Pulmón de Células no Pequeñas/complicaciones , Neoplasias Pulmonares/complicaciones , Metástasis Linfática/fisiopatología , Anciano , Carcinoma de Pulmón de Células no Pequeñas/patología , Femenino , Humanos , Inmunohistoquímica , Neoplasias Pulmonares/patología , Masculino , Estudios Retrospectivos
8.
J Clin Pathol ; 72(9): 603-608, 2019 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-31129615

RESUMEN

AIMS: Human epidermal growth factor receptor 2 (HER2)-targeted agents are effective against HER2-positive breast cancers. However, their lack of survival benefit in HER2-negative patients as well as their toxic effects and high cost highlight the need for accurate assessment of HER2 status. Our aim was to evaluate the clinical utility of a reagent-saving in situ hybridisation (Saving ISH) that facilitates hybridisation and saves HER2/chromosome enumeration probe by taking advantage of the non-contact mixing effect of an alternating current (AC) electric field. METHODS: With a new device, we apply a high-voltage, low-frequency AC electric field to the tissue sections, which mixes the probe within microdroplets as the voltage is switched on and off. Specimens (n=113) from patients with breast cancers identified immunohistochemically as HER2 0/1(+), (2+) or (3+) were used. The specimens were all tested using conventional dual ISH (DISH), DISH with an automated slide stainer (ASS) and Saving ISH (1:1-1:3 dilution). RESULTS: The Saving ISH with 1:2 probe dilution produced stable results with less non-specific staining while using smaller amounts of probe. The accuracy of HER2 status with Saving ISH was equal to standard. We found 96.4% agreement between DISH using ASS and Saving ISH (kappa coefficient=0.912). CONCLUSIONS: These results suggest reagent-saving HER2 ISH could be used as a clinical tool for accurate and stable HER2 assessment, even when reagent concentrations vary.


Asunto(s)
Biomarcadores de Tumor/genética , Neoplasias de la Mama/genética , Electricidad , Amplificación de Genes , Hibridación in Situ/métodos , Receptor ErbB-2/genética , Biomarcadores de Tumor/análisis , Neoplasias de la Mama/enzimología , Neoplasias de la Mama/patología , Diseño de Equipo , Femenino , Humanos , Inmunohistoquímica , Hibridación in Situ/instrumentación , Valor Predictivo de las Pruebas , Receptor ErbB-2/análisis , Reproducibilidad de los Resultados
9.
Artículo en Inglés | MEDLINE | ID: mdl-24109762

RESUMEN

Infants are known to suckle and ingest breast milk by wrapping the tongue around a nipple, writhing the tongue, and pressing the nipple. However, the dynamic mechanisms of tongue movement are still obscure, and factors related to sucking difficulties of infants are not well understood. We developed an artificial nipple installed with small cantilever-type sensors and directly measured the force applied on the nipple by the tongue. Small force sensors were arranged within the artificial nipple in a two-dimensional matrix of 3 × 2 to measure the force at 6 points. Subjects were 20 healthy infants (Group A) and 5 infants who had difficulty sucking (Group B). The latter could not breastfeed well and were fed from bottles or tubes. Informed consent was provided by the parents or guardians. The measured maximum force at the tip of the nipple was 1.4 ± 0.4 N and 1.2 ± 0.3 N (mean ± SD) in Groups A and B, respectively. At the base of the nipple, the maximum force recorded was 0.8 ± 0.5 N and 0.3 ± 0.3 N (mean ± SD), respectively, showing a statistically significant difference (p<0.05). The sucking period was 0.6 ± 0.1 s (mean ± SD) in both groups. The difference in time necessary to reach the maximum forces between the sensors at the tip and base was 39.7 ± 28.8 ms (mean ± SD) and 37.2 ± 75.9 ms in Groups A and B, respectively.


Asunto(s)
Pezones/anatomía & histología , Conducta en la Lactancia/fisiología , Lengua/anatomía & histología , Lactancia Materna , Femenino , Humanos , Lactante , Masculino
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...