Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
1.
Diabet Med ; : e15340, 2024 05 13.
Artículo en Inglés | MEDLINE | ID: mdl-38741266

RESUMEN

AIMS: Impaired awareness of hypoglycaemia (IAH) increases the risk of severe hypoglycaemia in people with type 1 diabetes mellitus (T1DM). IAH can be reversed through meticulous avoidance of hypoglycaemia. Diabetic autonomic neuropathy (DAN) has been proposed as an underlying mechanism contributing to IAH; however, data are inconsistent. The aim of this study was to examine the effects of cardiac autonomic neuropathy (CAN) on IAH reversibility inT1DM. METHODS: Participants with T1DM and IAH (Gold score ≥4) recruited to the HypoCOMPaSS (24-week 2 × 2 factorial randomised controlled) trial were included. All underwent screening for cardiac autonomic function testing at baseline and received comparable education and support aimed at avoiding hypoglycaemia and improving hypoglycaemia awareness. Definite CAN was defined as the presence of ≥2 abnormal cardiac reflex tests. Participants were grouped according to their CAN status, and changes in Gold score were compared. RESULTS: Eighty-three participants (52 women [62.7%]) were included with mean age (SD) of 48 (12) years and mean HbA1c of 66 (13) mmol/mol (8.2 [3.3] %). The mean duration of T1DM was 29 (13) years. The prevalence of CAN was low with 5/83 (6%) participants having definite autonomic neuropathy with 11 (13%) classified with possible/early neuropathy. All participants, regardless of the autonomic function status, showed a mean improvement in Gold score of ≥1 (mean improvement -1.2 [95% CI -0.8, -1.6]; p < 0.001). CONCLUSIONS: IAH can be improved in people with T1DM, and a long duration of disease, with and without cardiac autonomic dysfunction. These data suggest that CAN is not a prime driver for modulating IAH reversibility.

2.
Diabetes Care ; 43(1): 44-52, 2020 01.
Artículo en Inglés | MEDLINE | ID: mdl-31484666

RESUMEN

OBJECTIVE: The HypoCOMPaSS study was designed to test the hypothesis that successful avoidance of biochemical hypoglycemia without compromising overall glycemic control would restore sufficient hypoglycemia awareness to prevent recurrent severe hypoglycemia in the majority of participants with established type 1 diabetes. Before starting the study, we planned to investigate associations between baseline characteristics and recurrent severe hypoglycemia over 2 years' follow-up. RESEARCH DESIGN AND METHODS: A total of 96 adults with type 1 diabetes and impaired awareness of hypoglycemia participated in a 24-week 2 × 2 factorial randomized controlled trial comparing insulin delivery and glucose monitoring modalities, with the goal of rigorous biochemical hypoglycemia avoidance. The analysis included 71 participants who had experienced severe hypoglycemia in the 12-month prestudy with confirmed absence (complete responder) or presence (incomplete responder) of severe hypoglycemia over 24 months' follow-up. RESULTS: There were 43 (61%) complete responders and 28 (39%) incomplete responders experiencing mean ± SD 1.5 ± 1.0 severe hypoglycemia events/person-year. At 24 months, incomplete responders spent no more time with glucose ≤3 mmol/L (1.4 ± 2.1% vs. 3.0 ± 4.8% for complete responders; P = 0.26), with lower total daily insulin dose (0.45 vs. 0.58 units/24 h; P = 0.01) and greater impairment of hypoglycemia awareness (Clarke score: 3.8 ± 2.2 vs. 2.0 ± 1.9; P = 0.01). Baseline severe hypoglycemia rate (16.9 ± 16.3 vs. 6.4 ± 10.8 events/person-year; P = 0.002) and fear of hypoglycemia were higher in incomplete responders. Peripheral neuropathy was more prevalent in incomplete responders (11 [39%] vs. 2 [4.7%]; P < 0.001) with a trend toward increased autonomic neuropathy. CONCLUSIONS: Recurrent severe hypoglycemia was associated with higher preintervention severe hypoglycemia rate, fear of hypoglycemia, and concomitant neuropathy.


Asunto(s)
Concienciación , Trastornos del Conocimiento/sangre , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Hipoglucemia/inducido químicamente , Hipoglucemia/diagnóstico , Insulina/efectos adversos , Adolescente , Adulto , Anciano , Glucemia/análisis , Glucemia/efectos de los fármacos , Glucemia/metabolismo , Automonitorización de la Glucosa Sanguínea , Trastornos del Conocimiento/complicaciones , Trastornos del Conocimiento/diagnóstico , Diabetes Mellitus Tipo 1/sangre , Diabetes Mellitus Tipo 1/complicaciones , Diabetes Mellitus Tipo 1/diagnóstico , Femenino , Humanos , Hipoglucemia/psicología , Insulina/administración & dosificación , Sistemas de Infusión de Insulina , Masculino , Persona de Mediana Edad , Pronóstico , Recurrencia , Factores de Riesgo , Índice de Severidad de la Enfermedad , Resultado del Tratamiento , Adulto Joven
3.
Diabetes Technol Ther ; 21(11): 619-626, 2019 11.
Artículo en Inglés | MEDLINE | ID: mdl-31335201

RESUMEN

Background: In the HypoCOMPaSS trial, adults with long-standing type 1 diabetes and problematic hypoglycemia were randomized to compare insulin pump (continuous subcutaneous insulin infusion; CSII) with multiple daily injections (MDI) and real-time continuous glucose monitoring (RT-CGM) with conventional self-monitoring of blood glucose (SMBG). Our aim was to investigate participants' satisfaction with these technologies at 6-month randomized, controlled trial (RCT) endpoint and at 2-year follow-up. Methods: Participants completed the Insulin Treatment Satisfaction Questionnaire subscales "device delivery" and "hypoglycemia control"; and Glucose Monitoring Experience Questionnaire, assessing "convenience", "effectiveness", "intrusiveness", and "total satisfaction." We assessed change over time and between-group differences by insulin and monitoring modalities. Results: Participants (N = 96) were 64% women, aged 49 ± 12 years, with a diabetes duration of 29 ± 12 years. At 6 months, participants reported improvements compared with baseline (all P < 0.001) in satisfaction with insulin "delivery device" (r = 0.39) and "hypoglycemia control" (r = 0.52), and trends toward significance in perceived "effectiveness" (r = 0.42) and "intrusiveness" (r = 0.27) of monitoring device (but not "convenience", P = 0.139). All improvements were sustained at 2 years. At 6 months, the only difference between arms was that greater satisfaction with insulin "delivery device" was reported in the CSII group compared with MDI (P < 0.001, r = 0.40). No between-group differences were observed at 2 years. Conclusions: Overall, significant improvements in participant satisfaction with diabetes technologies were observed over the 6-month RCT, in all domains except "convenience," and maintained at 2 years. Although HypoCOMPaSS demonstrated noninferiority of SMBG versus CGM, and MDI versus CSII in terms of biomedical outcomes, detailed assessments confirm that participants' satisfaction with delivery device was greater in those allocated to CSII than MDI.


Asunto(s)
Glucemia/efectos de los fármacos , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Hemoglobina Glucada/efectos de los fármacos , Hipoglucemia/prevención & control , Hipoglucemiantes/administración & dosificación , Sistemas de Infusión de Insulina/estadística & datos numéricos , Insulina/administración & dosificación , Satisfacción del Paciente/estadística & datos numéricos , Adulto , Anciano , Automonitorización de la Glucosa Sanguínea , Diabetes Mellitus Tipo 1/sangre , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Resultado del Tratamiento , Adulto Joven
4.
Diabetes Care ; 41(12): 2625-2633, 2018 12.
Artículo en Inglés | MEDLINE | ID: mdl-30327358

RESUMEN

OBJECTIVE: Hypoglycemia has been linked to persistent increases in cardiovascular (CV) mortality in type 2 diabetes after the event. Our aim was to examine acute and downstream effects of hypoglycemia on markers of thrombosis risk and inflammation in type 2 diabetes. RESEARCH DESIGN AND METHODS: Twelve individuals with type 2 diabetes with no history of CV disease and 11 age- and BMI-matched volunteers without diabetes underwent paired hyperinsulinemic-euglycemic (glucose 6 mmol/L for two 60-min periods) and hypoglycemic (glucose 2.5 mmol/L for two 60-min periods) clamps on separate occasions on day 0. Fibrin clot properties, platelet reactivity, and inflammatory markers were measured at baseline, end of and after recovery from the initial clamp, day 1, and day 7 using validated assays and electron microscopy. RESULTS: Euglycemic hyperinsulinemia reduced platelet reactivity, decreased fibrin clot density, and improved fibrinolytic efficiency in both groups. Platelet reactivity and aggregation increased during acute hypoglycemia in both groups, resolving at recovery. In type 2 diabetes, clot lysis times and clot maximum absorbance increased up to day 7 (P = 0.002 and 0.001 vs. euglycemia, respectively), but clots from control subjects without diabetes showed limited changes. Fibrin network density increased Δ 1.15 ± 0.28 fibers/µm2 at day 7 after the hypoglycemic clamp (P < 0.01 for glycemic arm), whereas fibrinogen and complement C3 increased after hypoglycemia up to day 7 in type 2 diabetes only. CONCLUSIONS: Antecedent hypoglycemia has acute and persistent prothrombotic effects, lasting at least 7 days, that were enhanced in individuals with type 2 diabetes. These findings identify mechanisms by which hypoglycemia might increase short- and medium-term risk of CV mortality.


Asunto(s)
Diabetes Mellitus Tipo 2/complicaciones , Angiopatías Diabéticas/etiología , Hipoglucemia/inducido químicamente , Hipoglucemia/complicaciones , Hipoglucemiantes/efectos adversos , Trombosis/etiología , Adolescente , Adulto , Anciano , Biomarcadores/sangre , Glucemia/metabolismo , Sistema Cardiovascular/efectos de los fármacos , Diabetes Mellitus Tipo 2/sangre , Diabetes Mellitus Tipo 2/tratamiento farmacológico , Diabetes Mellitus Tipo 2/epidemiología , Angiopatías Diabéticas/epidemiología , Femenino , Técnica de Clampeo de la Glucosa , Humanos , Hiperinsulinismo/sangre , Hiperinsulinismo/complicaciones , Hiperinsulinismo/epidemiología , Hipoglucemiantes/administración & dosificación , Inflamación/sangre , Inflamación/epidemiología , Inflamación/etiología , Insulina/sangre , Masculino , Persona de Mediana Edad , Proyectos de Investigación , Trombosis/sangre , Trombosis/epidemiología , Adulto Joven
5.
Diabetes Care ; 41(8): 1600-1607, 2018 08.
Artículo en Inglés | MEDLINE | ID: mdl-29661916

RESUMEN

OBJECTIVE: Severe hypoglycemia is a feared complication of type 1 diabetes; yet, few trials have targeted prevention using optimized self-management (educational, therapeutic, and technological support). We aimed to investigate whether improved awareness and reduced severe hypoglycemia, achieved during an intensive randomized clinical trial (RCT), were sustained after return to routine care. RESEARCH DESIGN AND METHODS: Ninety-six adults with type 1 diabetes (29 ± 12 years' duration) and impaired awareness of hypoglycemia at five U.K. tertiary referral diabetes centers were recruited into a 24-week 2 × 2 factorial RCT (HypoCOMPaSS). Participants were randomized to pump (continuous subcutaneous insulin infusion [CSII]) or multiple daily injections (MDIs) and real-time continuous glucose monitoring (RT-CGM) or self-monitoring of blood glucose (SMBG), with equal education/attention to all groups. At 24 weeks, participants returned to routine care with follow-up until 24 months, including free choice of MDI/CSII; RT-CGM vs. SMBG comparison continued to 24 months. Primary outcome was mean difference (baseline to 24 months [between groups]) in hypoglycemia awareness. RESULTS: Improvement in hypoglycemia awareness was sustained (Gold score at baseline 5.1 ± 1.1 vs. 24 months 3.7 ± 1.9; P < 0.0001). Severe hypoglycemia rate was reduced from 8.9 ± 12.8 episodes/person-year over the 12 months prestudy to 0.4 ± 0.8 over 24 months (P < 0.0001). HbA1c improved (baseline 8.2 ± 3.2% [66 ± 12 mmol/mol] vs. 24 months 7.7 ± 3.1% [61 ± 10 mmol/mol]; P = 0.003). Improvement in treatment satisfaction and reduced fear of hypoglycemia were sustained. There were no significant differences between interventions at 24 months. CONCLUSIONS: Optimized insulin replacement and glucose monitoring underpinned by hypoglycemia-focused structured education should be provided to all with type 1 diabetes complicated by impaired awareness of hypoglycemia.


Asunto(s)
Concienciación , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Hipoglucemia/inducido químicamente , Hipoglucemia/epidemiología , Insulina/efectos adversos , Adulto , Glucemia/efectos de los fármacos , Glucemia/metabolismo , Automonitorización de la Glucosa Sanguínea , Diabetes Mellitus Tipo 1/sangre , Diabetes Mellitus Tipo 1/epidemiología , Femenino , Estudios de Seguimiento , Hemoglobina Glucada/análisis , Humanos , Hipoglucemia/sangre , Hipoglucemia/psicología , Inyecciones , Insulina/administración & dosificación , Sistemas de Infusión de Insulina , Masculino , Persona de Mediana Edad , Índice de Severidad de la Enfermedad
6.
Diabetes ; 66(5): 1322-1333, 2017 05.
Artículo en Inglés | MEDLINE | ID: mdl-28137792

RESUMEN

Hypoglycemia is associated with increased cardiovascular mortality in trials of intensive therapy in type 2 diabetes mellitus (T2DM). We previously observed an increase in arrhythmias during spontaneous prolonged hypoglycemia in patients with T2DM. We examined changes in cardiac autonomic function and repolarization during sustained experimental hypoglycemia. Twelve adults with T2DM and 11 age- and BMI-matched control participants without diabetes underwent paired hyperinsulinemic clamps separated by 4 weeks. Glucose was maintained at euglycemia (6.0 mmol/L) or hypoglycemia (2.5 mmol/L) for 1 h. Heart rate, blood pressure, and heart rate variability were assessed every 30 min and corrected QT intervals and T-wave morphology every 60 min. Heart rate initially increased in participants with T2DM but then fell toward baseline despite maintained hypoglycemia at 1 h accompanied by reactivation of vagal tone. In control participants, vagal tone remained depressed during sustained hypoglycemia. Participants with T2DM exhibited greater heterogeneity of repolarization during hypoglycemia as demonstrated by T-wave symmetry and principal component analysis ratio compared with control participants. Epinephrine levels during hypoglycemia were similar between groups. Cardiac autonomic regulation during hypoglycemia appears to be time dependent. Individuals with T2DM demonstrate greater repolarization abnormalities for a given hypoglycemic stimulus despite comparable sympathoadrenal responses. These mechanisms could contribute to arrhythmias during clinical hypoglycemic episodes.


Asunto(s)
Arritmias Cardíacas/fisiopatología , Sistema Nervioso Autónomo/efectos de los fármacos , Presión Sanguínea/efectos de los fármacos , Diabetes Mellitus Tipo 2/fisiopatología , Frecuencia Cardíaca/efectos de los fármacos , Corazón/efectos de los fármacos , Hipoglucemia/fisiopatología , Hipoglucemiantes/farmacología , Insulina/farmacología , Adulto , Arritmias Cardíacas/inducido químicamente , Sistema Nervioso Autónomo/fisiopatología , Presión Sanguínea/fisiología , Electrocardiografía , Epinefrina/sangre , Femenino , Técnica de Clampeo de la Glucosa , Corazón/fisiopatología , Frecuencia Cardíaca/fisiología , Humanos , Hipoglucemia/inducido químicamente , Masculino , Persona de Mediana Edad , Nervio Vago/efectos de los fármacos , Nervio Vago/fisiopatología
7.
Artículo en Inglés | MEDLINE | ID: mdl-29302329

RESUMEN

Bariatric surgery is an effective therapy for obesity but is associated with long-term complications such as dumping syndromes and nutritional deficiencies. We report a case of a 26-year-old caucasian female, with history of morbid obesity and gestational diabetes (GDM), who became pregnant 4 months after Roux-en-Y bypass surgery. She developed GDM during subsequent pregnancy, which was initially managed with metformin and insulin. Nocturnal hypoglycaemia causing sleep disturbance and daytime somnolence occured at 19 weeks of pregnancy (19/40). Treatment with rapid-acting carbohydrates precipitated further hypoglycaemia. Laboratory investigations confirmed hypoglycaemia at 2.2 mmol/L with appropriately low insulin and C-peptide, intact HPA axis and negative IgG insulin antibodies. The patient was seen regularly by the bariatric dietetic team but concerns about compliance persisted. A FreeStyle Libre system was used from 21/40 enabling the patient a real-time feedback of changes in interstitial glucose following high or low GI index food intake. The patient declined a trial of acarbose but consented to an intraveneous dextrose infusion overnight resulting in improvement but not complete abolishment of nocturnal hypoglycaemia. Hypoglycaemias subsided at 34/40 and metformin and insulin had to be re-introduced due to high post-prandial blood glucose readings. An emergency C-section was indicated at 35 + 1/40 and a small-for-gestational-age female was delivered. There have been no further episodes of hypoglycaemia following delivery. This case illustrates challenges in the management of pregnancy following bariatric surgery. To our knowledge, this is the first use of FreeStyle Libre in dumping syndrome in pregnancy following bariatric surgery with troublesome nocturnal hypoglycaemia. LEARNING POINTS: Bariatric surgery represents the most effective treatment modality in cases of severe obesity. With increasing prevalence of obesity, more people are likely to undergo bariatric procedures, many of which are women of childbearing age.Fertility generally improves after bariatric surgery due to weight reduction, but pregnancy is not recommended for at least 12-24 months after surgery. If pregnancy occurs, there are currently little evidence-based guidelines available on how to manage complications such as dumping syndromes or gestational diabetes (GDM) in women with history of bariatric surgery.Diagnosis of GDM relies on the use of a 75 g oral glucose tolerance test (OGTT). The use of this test in pregnant women is not recommended due to its potential to precipitate dumping syndrome. Capillary glucose monitoring profiles or continuous glucose monitoring (CGM) is being currently discussed as alternative testing modalities.As the CGM technology becomes more available, including the recently introduced FreeStyle Libre Flash glucose monitoring system, more pregnant women, including those after bariatric surgery, will have access to this technology. We suggest urgent development of guidelines regarding the use of CGM and flash glucose monitoring tools in these circumstances and in the interim recommend careful consideration of their use on a case-to-case basis.

10.
Lancet ; 385 Suppl 1: S96, 2015 Feb 26.
Artículo en Inglés | MEDLINE | ID: mdl-26312919

RESUMEN

BACKGROUND: The closed-loop system (artificial pancreas) delivers insulin in a glucose-responsive manner by the use of a control algorithm that automatically directs insulin delivery, based on real-time sensor glucose concentrations. Results from hospital-based studies have shown improved overnight glucose control and reduced risk of hypoglycaemia in type 1 diabetes. We aimed to assess whether unsupervised closed-loop systems can provide a realistic treatment option in patients with type 1 diabetes. METHODS: We combined data from two open-label, phase 2, randomised, cross-over, unsupervised home trials of people with type 1 diabetes, one in 24 adults (mean age 43 years [SD 12], HbA1c 8·0% [0·9]) and the other in 16 adolescents (15·6 [3·6], 8·1 [0·8]). In each trial, after training on study devices, participants were allocated to two periods of sensor-augmented pump therapy either with or without overnight closed loop that used a model predictive control algorithm to direct insulin delivery. Allocation sequence was done with a computer-generated random code. Each period lasted 4 weeks in adults and 3 weeks in adolescents. Primary outcome for both trials was time when sensor glucose was in the target range (3·9-8·0 mmol/L). Analysis was by intention to treat. Participants (or parents) gave written informed consent. The trials are registered with ClinicalTrials.gov, numbers NCT01440140 and NCT01221467. FINDINGS: Closed loop was started by participants on their own volition on 866 (89%) of 978 nights. The proportion of time when sensor glucose was in the target range between 0000 h and 0800 h was increased by a mean of 18·4% (95% CI 13·5-23·4, p<0·0001) during closed loop compared with no closed loop. Closed loop significantly reduced mean overnight sensor glucose by 0·9 mmol/L (95% CI 0·4-1·3, p=0·0001), and reduced the proportion of time when sensor glucose values were suggestive of hyperglycaemia (>8·0 mmol/L) (15·9%, 10·7-21·0; p<0·0001) and hypoglycaemia (<3·9 mmol/L) (median 0·9, IQR 0·2-2·2; p=0·014). Lower mean overnight glucose was associated with increased overnight insulin delivery (p<0·0001) without changing total daily insulin amount (p=0·84). INTERPRETATION: Extended use of overnight closed loop at home without supervision is feasible in adults and adolescents with type 1 diabetes. Clinically significant reduction in overnight glucose was observed accompanied by reduced time spent by patients in hypoglycaemia. To our knowledge, such combined effect has not been documented with any other means of intensified conventional insulin delivery. Longer term studies are warranted to assess its clinical potential. FUNDING: Diabetes UK, Juvenile Diabetes Research Foundation, NIHR Cambridge Biomedical Research Centre.

11.
Diabetes Technol Ther ; 17(11): 801-7, 2015 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-26241693

RESUMEN

OBJECTIVES: Closed-loop (CL) systems modulate insulin delivery based on glucose levels measured by a continuous glucose monitor (CGM). Accuracy of the CGM affects CL performance and safety. We evaluated the accuracy of the Freestyle Navigator(®) II CGM (Abbott Diabetes Care, Alameda, CA) during three unsupervised, randomized, open-label, crossover home CL studies. MATERIALS AND METHODS: Paired CGM and capillary glucose values (10,597 pairs) were collected from 57 participants with type 1 diabetes (41 adults [mean±SD age, 39±12 years; mean±SD hemoglobin A1c, 7.9±0.8%] recruited at five centers and 16 adolescents [mean±SD age, 15.6±3.6 years; mean±SD hemoglobin A1c, 8.1±0.8%] recruited at two centers). Numerical accuracy was assessed by absolute relative difference (ARD) and International Organization for Standardization (ISO) 15197:2013 15/15% limits, and clinical accuracy was assessed by Clarke error grid analysis. RESULTS: Total duration of sensor use was 2,002 days (48,052 h). Overall sensor accuracy for the capillary glucose range (1.1-27.8 mmol/L) showed mean±SD and median (interquartile range) ARD of 14.2±15.5% and 10.0% (4.5%, 18.4%), respectively. Lowest mean ARD was observed in the hyperglycemic range (9.8±8.8%). Over 95% of pairs were in combined Clarke error grid Zones A and B (A, 80.1%, B, 16.2%). Overall, 70.0% of the sensor readings satisfied ISO criteria. Mean ARD was consistent (12.3%; 95% of the values fall within ±3.7%) and not different between participants (P=0.06) within the euglycemic and hyperglycemic range, when CL is actively modulating insulin delivery. CONCLUSIONS: Consistent accuracy of the CGM within the euglycemic-hyperglycemic range using the Freestyle Navigator II was observed and supports its use in home CL studies. Our results may contribute toward establishing normative CGM performance criteria for unsupervised home use of CL.


Asunto(s)
Automonitorización de la Glucosa Sanguínea/normas , Glucemia/análisis , Diabetes Mellitus Tipo 1/sangre , Adolescente , Adulto , Automonitorización de la Glucosa Sanguínea/instrumentación , Niño , Estudios Cruzados , Diabetes Mellitus Tipo 1/complicaciones , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Diseño de Equipo , Femenino , Hemoglobina Glucada/análisis , Humanos , Hipoglucemia/diagnóstico , Hipoglucemia/tratamiento farmacológico , Hipoglucemia/etiología , Hipoglucemiantes/administración & dosificación , Insulina/administración & dosificación , Sistemas de Infusión de Insulina/normas , Masculino , Persona de Mediana Edad , Valores de Referencia , Reproducibilidad de los Resultados , Condiciones Sociales , Método Teach-Back , Factores de Tiempo
13.
Lancet Diabetes Endocrinol ; 2(9): 701-9, 2014 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-24943065

RESUMEN

BACKGROUND: Closed-loop insulin delivery is a promising option to improve glycaemic control and reduce the risk of hypoglycaemia. We aimed to assess whether overnight home use of automated closed-loop insulin delivery would improve glucose control. METHODS: We did this open-label, multicentre, randomised controlled, crossover study between Dec 1, 2012, and Dec 23, 2014, recruiting patients from three centres in the UK. Patients aged 18 years or older with type 1 diabetes were randomly assigned to receive 4 weeks of overnight closed-loop insulin delivery (using a model-predictive control algorithm to direct insulin delivery), then 4 weeks of insulin pump therapy (in which participants used real-time display of continuous glucose monitoring independent of their pumps as control), or vice versa. Allocation to initial treatment group was by computer-generated permuted block randomisation. Each treatment period was separated by a 3-4 week washout period. The primary outcome was time spent in the target glucose range of 3·9-8·0 mmol/L between 0000 h and 0700 h. Analyses were by intention to treat. This trial is registered with ClinicalTrials.gov, number NCT01440140. FINDINGS: We randomly assigned 25 participants to initial treatment in either the closed-loop group or the control group, patients were later crossed over into the other group; one patient from the closed-loop group withdrew consent after randomisation, and data for 24 patients were analysed. Closed loop was used over a median of 8·3 h (IQR 6·0-9·6) on 555 (86%) of 644 nights. The proportion of time when overnight glucose was in target range was significantly higher during the closed-loop period compared to during the control period (mean difference between groups 13·5%, 95% CI 7·3-19·7; p=0·0002). We noted no severe hypoglycaemic episodes during the control period compared with two episodes during the closed-loop period; these episodes were not related to closed-loop algorithm instructions. INTERPRETATION: Unsupervised overnight closed-loop insulin delivery at home is feasible and could improve glucose control in adults with type 1 diabetes. FUNDING: Diabetes UK.


Asunto(s)
Glucemia/efectos de los fármacos , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Hemoglobina Glucada/efectos de los fármacos , Hipoglucemia/prevención & control , Hipoglucemiantes/administración & dosificación , Insulina/administración & dosificación , Páncreas Artificial , Adulto , Algoritmos , Glucemia/metabolismo , Estudios Cruzados , Diabetes Mellitus Tipo 1/sangre , Diabetes Mellitus Tipo 1/epidemiología , Femenino , Hemoglobina Glucada/metabolismo , Humanos , Sistemas de Infusión de Insulina , Masculino , Persona de Mediana Edad , Resultado del Tratamiento , Reino Unido/epidemiología
14.
Diabetes Care ; 37(8): 2114-22, 2014 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-24854041

RESUMEN

OBJECTIVE: To determine whether impaired awareness of hypoglycemia (IAH) can be improved and severe hypoglycemia (SH) prevented in type 1 diabetes, we compared an insulin pump (continuous subcutaneous insulin infusion [CSII]) with multiple daily injections (MDIs) and adjuvant real-time continuous glucose monitoring (RT) with conventional self-monitoring of blood glucose (SMBG). RESEARCH DESIGN AND METHODS: A 24-week 2 × 2 factorial randomized controlled trial in adults with type 1 diabetes and IAH was conducted. All received comparable education, support, and congruent therapeutic targets aimed at rigorous avoidance of biochemical hypoglycemia without relaxing overall control. Primary end point was between-intervention difference in 24-week hypoglycemia awareness (Gold score). RESULTS: A total of 96 participants (mean diabetes duration 29 years) were randomized. Overall, biochemical hypoglycemia (≤3.0 mmol/L) decreased (53 ± 63 to 24 ± 56 min/24 h; P = 0.004 [t test]) without deterioration in HbA1c. Hypoglycemia awareness improved (5.1 ± 1.1 to 4.1 ± 1.6; P = 0.0001 [t test]) with decreased SH (8.9 ± 13.4 to 0.8 ± 1.8 episodes/patient-year; P = 0.0001 [t test]). At 24 weeks, there was no significant difference in awareness comparing CSII with MDI (4.1 ± 1.6 vs. 4.2 ± 1.7; difference 0.1; 95% CI -0.6 to 0.8) and RT with SMBG (4.3 ± 1.6 vs. 4.0 ± 1.7; difference -0.3; 95% CI -1.0 to 0.4). Between-group analyses demonstrated comparable reductions in SH, fear of hypoglycemia, and insulin doses with equivalent HbA1c. Treatment satisfaction was higher with CSII than MDI (32 ± 3 vs. 29 ± 6; P = 0.0003 [t test]), but comparable with SMBG and RT (30 ± 5 vs. 30 ± 5; P = 0.79 [t test]). CONCLUSIONS: Hypoglycemia awareness can be improved and recurrent SH prevented in long-standing type 1 diabetes without relaxing HbA1c. Similar biomedical outcomes can be attained with conventional MDI and SMBG regimens compared with CSII/RT, although satisfaction was higher with CSII.


Asunto(s)
Diabetes Mellitus Tipo 1/tratamiento farmacológico , Hipoglucemiantes/administración & dosificación , Insulina/administración & dosificación , Adolescente , Adulto , Anciano , Concienciación , Glucemia/metabolismo , Automonitorización de la Glucosa Sanguínea , Diabetes Mellitus Tipo 1/sangre , Diabetes Mellitus Tipo 1/psicología , Esquema de Medicación , Femenino , Hemoglobina Glucada/metabolismo , Humanos , Hipoglucemia/sangre , Hipoglucemia/prevención & control , Hipoglucemia/psicología , Infusiones Subcutáneas , Inyecciones , Sistemas de Infusión de Insulina , Masculino , Persona de Mediana Edad , Satisfacción del Paciente , Recurrencia , Adulto Joven
15.
Diabetes Care ; 36(12): 4063-70, 2013 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-24130355

RESUMEN

OBJECTIVE: Impaired awareness of hypoglycemia (IAH) and defective counterregulation significantly increase severe hypoglycemia risk in type 1 diabetes (T1D). We evaluated restoration of IAH/defective counterregulation by a treatment strategy targeted at hypoglycemia avoidance in adults with T1D with IAH (Gold score ≥4) participating in the U.K.-based multicenter HypoCOMPaSS randomized controlled trial. RESEARCH DESIGN AND METHODS: Eighteen subjects with T1D and IAH (mean ± SD age 50 ± 9 years, T1D duration 35 ± 10 years, HbA1c 8.1 ± 1.0% [65 ± 10.9 mmol/mol]) underwent stepped hyperinsulinemic-hypoglycemic clamp studies before and after a 6-month intervention. The intervention comprised the HypoCOMPaSS education tool in all and randomized allocation, in a 2 × 2 factorial study design, to multiple daily insulin analog injections or continuous subcutaneous insulin infusion therapy and conventional glucose monitoring or real-time continuous glucose monitoring. Symptoms, cognitive function, and counterregulatory hormones were measured at each glucose plateau (5.0, 3.8, 3.4, 2.8, and 2.4 mmol/L), with each step lasting 40 min with subjects kept blinded to their actual glucose value throughout clamp studies. RESULTS: After intervention, glucose concentrations at which subjects first felt hypoglycemic increased (mean ± SE from 2.6 ± 0.1 to 3.1 ± 0.2 mmol/L, P = 0.02), and symptom and plasma metanephrine responses to hypoglycemia were higher (median area under curve for symptoms, 580 [interquartile range {IQR} 420-780] vs. 710 [460-1,260], P = 0.02; metanephrine, 2,412 [-3,026 to 7,279] vs. 5,180 [-771 to 11,513], P = 0.01). Glycemic threshold for deterioration of cognitive function measured by four-choice reaction time was unchanged, while the color-word Stroop test showed a degree of adaptation. CONCLUSIONS: Even in long-standing T1D, IAH and defective counterregulation may be improved by a clinical strategy aimed at hypoglycemia avoidance.


Asunto(s)
Concienciación , Glucemia/metabolismo , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Hemoglobina Glucada/metabolismo , Hipoglucemia/prevención & control , Hipoglucemia/psicología , Insulina/administración & dosificación , Adulto , Diabetes Mellitus Tipo 1/sangre , Diabetes Mellitus Tipo 1/psicología , Relación Dosis-Respuesta a Droga , Femenino , Técnica de Clampeo de la Glucosa , Humanos , Hipoglucemia/sangre , Hipoglucemiantes/administración & dosificación , Sistemas de Infusión de Insulina , Masculino , Persona de Mediana Edad , Resultado del Tratamiento
16.
BMC Endocr Disord ; 12: 33, 2012 Dec 13.
Artículo en Inglés | MEDLINE | ID: mdl-23237320

RESUMEN

BACKGROUND: Severe hypoglycaemia (SH) is one of the most feared complications of type 1 diabetes (T1DM) with a reported prevalence of nearly 40%. In randomized trials of Multiple Daily Injections (MDI) and Continuous Subcutaneous Insulin Infusion (CSII) therapy there is a possible benefit of CSII in reducing SH. However few trials have used basal insulin analogues as the basal insulin in the MDI group and individuals with established SH have often been excluded from prospective studies. In published studies investigating the effect of Real Time Continuous Glucose Monitoring (RT-CGM) benefit in terms of reduced SH has not yet been demonstrated. The primary objective of this study is to elucidate whether in people with T1DM complicated by impaired awareness of hypoglycaemia (IAH), rigorous prevention of biochemical hypoglycaemia using optimized existing self-management technology and educational support will restore awareness and reduce risk of recurrent SH. METHODS/DESIGN: This is a multicentre prospective RCT comparing hypoglycaemia avoidance with optimized MDI and CSII with or without RT-CGM in a 2×2 factorial design in people with type 1 diabetes who have IAH. The primary outcome measure for this study is the difference in IAH (Gold score) at 24 weeks. Secondary outcomes include biomedical measures such as HbA1c, SH incidence, blinded CGM analysis, self monitored blood glucose (SMBG) and response to hypoglycaemia in gold standard clamp studies. Psychosocial measures including well-being and quality of life will also be assessed using several validated and novel measures. Analysis will be on an intention-to-treat basis. DISCUSSION: Most existing RCTs using this study's interventions have been powered for change in HbA1c rather than IAH or SH. This trial will demonstrate whether IAH can be reversed and SH prevented in people with T1DM in even those at highest risk by using optimized conventional management and existing technology. TRIAL REGISTRATION: ISRCTN52164803 Eudract No: 2009-015396-27.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...