Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
1.
Endosc Int Open ; 12(5): E704-E714, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38812697

RESUMEN

Background and study aims Sedation of high-risk patients is a relevant issue in interventional endoscopy. This is especially because standard oximetric monitors display only hypoxia and not the preceding hypercapnia. Therefore, the question arises whether use of a nasal positive airway pressure (nPAP) system can decrease the rate of sedation-associated events. Patients and methods A randomized, prospective trial was conducted at University Hospital Ulm, including 98 consecutive patients, identified as high-risk (American Society of Anesthesiologists physical status ≥3) and scheduled for prolonged (>15 minutes) endoscopic procedures. Patients underwent 1:1 randomization to two groups: interventional (nPAP-Mask) and control (conventional oxygen supplementation). Levels of CO 2 were measured noninvasively by transcutaneous capnometry device. The primary outcome was incidence of hypoxia (SpO 2 <90% over 10 seconds) and incidence of severe hypoxia was incidence of SpO 2 <80% over 10 seconds. One of our secondary objectives was to determine if the nPAP-Mask could result in significant CO 2 retention among high-risk patients. Results Data analysis showed lower incidence of hypoxia in the interventional group (10/47 vs. 31/251) P <0.05. Episodes of severe hypoxia (SpO 2 <80% over 10 seconds) were more frequent in the control group (8/51) compared with the intervention group (2/47) P <0.05. There was no significant difference in ΔCO 2 levels in the interventional vs. control group (-6.01±7.66 vs. -7.35±8.59 mm Hg). Conclusions In high-risk patients use of a nasal positive airway pressure system could significantly lower risk of hypoxia, especially in prolonged procedures. The nPAP-Mask does not induce CO 2 retention when compared with conventional oxygen supplementation.

4.
Endoscopy ; 56(1): 63-69, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37532115

RESUMEN

BACKGROUND AND STUDY AIMS: Artificial intelligence (AI)-based systems for computer-aided detection (CADe) of polyps receive regular updates and occasionally offer customizable detection thresholds, both of which impact their performance, but little is known about these effects. This study aimed to compare the performance of different CADe systems on the same benchmark dataset. METHODS: 101 colonoscopy videos were used as benchmark. Each video frame with a visible polyp was manually annotated with bounding boxes, resulting in 129 705 polyp images. The videos were then analyzed by three different CADe systems, representing five conditions: two versions of GI Genius, Endo-AID with detection Types A and B, and EndoMind, a freely available system. Evaluation included an analysis of sensitivity and false-positive rate, among other metrics. RESULTS: Endo-AID detection Type A, the earlier version of GI Genius, and EndoMind detected all 93 polyps. Both the later version of GI Genius and Endo-AID Type B missed 1 polyp. The mean per-frame sensitivities were 50.63 % and 67.85 %, respectively, for the earlier and later versions of GI Genius, 65.60 % and 52.95 %, respectively, for Endo-AID Types A and B, and 60.22 % for EndoMind. CONCLUSIONS: This study compares the performance of different CADe systems, different updates, and different configuration modes. This might help clinicians to select the most appropriate system for their specific needs.


Asunto(s)
Pólipos del Colon , Neoplasias Colorrectales , Humanos , Pólipos del Colon/diagnóstico por imagen , Inteligencia Artificial , Colonoscopía/métodos , Neoplasias Colorrectales/diagnóstico
5.
Endoscopy ; 55(12): 1072-1080, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37451283

RESUMEN

BACKGROUND: Texture and color enhancement imaging (TXI) was recently proposed as a substitute for standard high definition white-light imaging (WLI) to increase lesion detection during colonoscopy. This international, multicenter randomized trial assessed the efficacy of TXI in detection of colorectal neoplasia. METHODS: Consecutive patients aged ≥ 40 years undergoing screening, surveillance, or diagnostic colonoscopies at five centers (Italy, Germany, Japan) between September 2021 and May 2022 were enrolled. Patients were randomly assigned (1:1) to TXI or WLI. Primary outcome was adenoma detection rate (ADR). Secondary outcomes were adenomas per colonoscopy (APC) and withdrawal time. Relative risks (RRs) adjusted for age, sex, and colonoscopy indication were calculated. RESULTS: We enrolled 747 patients (mean age 62.3 [SD 9.5] years, 50.2 % male). ADR was significantly higher with TXI (221/375, 58.9 %) vs. WLI (159/372, 42.7 %; adjusted RR 1.38 [95 %CI 1.20-1.59]). This was significant for ≤ 5 mm (RR 1.42 [1.16-1.73]) and 6-9 mm (RR 1.36 [1.01-1.83]) adenomas. A higher proportion of polypoid (151/375 [40.3 %] vs. 104/372 [28.0 %]; RR 1.43 [1.17-1.75]) and nonpolypoid (136/375 [36.3 %] vs. 102/372 [27.4 %]; RR 1.30 [1.05-1.61]) adenomas, and proximal (143/375 [38.1 %] vs. 111/372 [29.8 %]; RR 1.28 [1.05-1.57]) and distal (144/375 [38.4 %] vs. 98/372 [26.3 %]; RR 1.46 [1.18-1.80]) lesions were found with TXI. APC was higher with TXI (1.36 [SD 1.79] vs. 0.89 [SD 1.35]; incident rate ratio 1.53 [1.25-1.88]). CONCLUSIONS: TXI increased ADR and APC among patients undergoing colonoscopy for various indications. TXI increased detection of polyps < 10 mm, both in the proximal and distal colon, and may help to improve colonoscopy quality indicators.


Asunto(s)
Adenoma , Pólipos del Colon , Neoplasias Colorrectales , Pólipos , Humanos , Masculino , Persona de Mediana Edad , Femenino , Neoplasias Colorrectales/diagnóstico por imagen , Neoplasias Colorrectales/patología , Colonoscopía/métodos , Pólipos/diagnóstico , Adenoma/diagnóstico por imagen , Adenoma/patología , Pólipos del Colon/diagnóstico por imagen , Pólipos del Colon/patología
6.
J Med Internet Res ; 24(10): e37497, 2022 10 05.
Artículo en Inglés | MEDLINE | ID: mdl-36197717

RESUMEN

BACKGROUND: Gastrointestinal diseases are associated with substantial cost in health care. In times of the COVID-19 pandemic and further digitalization of gastrointestinal tract health care, mobile health apps could complement routine health care. Many gastrointestinal health care apps are already available in the app stores, but the quality, data protection, and reliability often remain unclear. OBJECTIVE: This systematic review aimed to evaluate the quality characteristics as well as the privacy and security measures of mobile health apps for the management of gastrointestinal diseases. METHODS: A web crawler systematically searched for mobile health apps with a focus on gastrointestinal diseases. The identified mobile health apps were evaluated using the Mobile Application Rating Scale (MARS). Furthermore, app characteristics, data protection, and security measures were collected. Classic user star rating was correlated with overall mobile health app quality. RESULTS: The overall quality of the mobile health apps (N=109) was moderate (mean 2.90, SD 0.52; on a scale ranging from 1 to 5). The quality of the subscales ranged from low (mean 1.89, SD 0.66) to good (mean 4.08, SD 0.57). The security of data transfer was ensured only by 11 (10.1%) mobile health apps. None of the mobile health apps had an evidence base. The user star rating did not correlate with the MARS overall score or with the individual subdimensions of the MARS (all P>.05). CONCLUSIONS: Mobile health apps might have a positive impact on diagnosis, therapy, and patient guidance in gastroenterology in the future. We conclude that, to date, data security and proof of efficacy are not yet given in currently available mobile health apps.


Asunto(s)
COVID-19 , Enfermedades Gastrointestinales , Aplicaciones Móviles , Telemedicina , Enfermedades Gastrointestinales/terapia , Humanos , Pandemias , Reproducibilidad de los Resultados
7.
Sci Rep ; 12(1): 8538, 2022 05 20.
Artículo en Inglés | MEDLINE | ID: mdl-35595856

RESUMEN

Physical stress is common in GI endoscopists, leading to musculoskeletal disorders. Considering the increasing complexity of interventional GI endoscopy with prolonged examination time, work-related musculoskeletal disorders have come into focus. However, data on work-related health stress in German endoscopists are elusive. The aim of this study was therefore to investigate the prevalence and consequences of work-related musculoskeletal disorders in German endoscopists. A 24-item questionnaire on endoscopy-associated musculoskeletal disorders and standardized pain assessment was developed by an interdisciplinary team of endoscopists and sports medics. The survey was distributed online by the leading German societies for gastroenterology and endoscopy. Overall, 151 German practicing endoscopists took part in the study. Regarding the average number of endoscopic procedures per week, the study collective consisted mainly of high-volume endoscopists. The survey showed that most participants suffered from general musculoskeletal disorders (82.8%) and from work-related musculoskeletal disorders (76.8%). The most affected body parts were the neck, low back, thumb, and shoulder. Temporary absence from work due to symptoms was reported by 9.9% of the respondents. Over 30% of participating endoscopists stated the need for analgesics or physiotherapy due to musculoskeletal disorders. Age, professional experience and work time were identified as relevant risk factors for musculoskeletal health issues. A high number of German endoscopists are affected by musculoskeletal disorders due to specific working postures and repetitive movements with a large impact on personal health. Further interventional studies are mandatory to improve the risk prevention of endoscopic activity.


Asunto(s)
Enfermedades Musculoesqueléticas , Enfermedades Profesionales , Endoscopía Gastrointestinal/efectos adversos , Alemania/epidemiología , Humanos , Enfermedades Musculoesqueléticas/epidemiología , Enfermedades Musculoesqueléticas/etiología , Enfermedades Profesionales/epidemiología , Enfermedades Profesionales/etiología , Enfermedades Profesionales/prevención & control , Prevalencia , Factores de Riesgo , Encuestas y Cuestionarios
8.
Endosc Int Open ; 10(1): E3-E8, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-35047329

RESUMEN

Background and study aims Unbiased communication is crucial for excellent teamwork in high-quality endoscopy. Personal protective equipment (PPE) (FFP-masks and face-shields) worn by endoscopists that are ubiquitous in the current COVID-19 pandemic strikingly impair communication. Digital enhancement approaches to maintain team communication, especially during complex endoscopic procedures, are urgently warranted. Materials and methods A prospective, two-armed interventional study was performed at an endoscopy unit at a tertiary center in Germany. Two hundred and three endoscopic procedures with PPE se according to pandemic risk level were randomly assigned (1:1) to a group performed by an endoscopy team equipped with digital enhanced cordless telecommunication (DECT) or one without digital-enhanced communication. The primary outcome was the team-reported number of communication-associated events (CAEs) defined as misunderstandings that impaired workflow during endoscopic examination. Secondary outcomes included perceived voice and headphone quality and overall comfort with DECT during endoscopic work. Results The use of DECT was associated with a significant reduction in communication-associated events in endoscopic procedures and overall, was perceived positively. Conclusions Digital enhancement of communication is a promising and easy-to- establish tool for improving team communication quality in endoscopy.

9.
Endosc Int Open ; 7(12): E1658-E1662, 2019 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-31788549

RESUMEN

Background and study aims Endoscopic ultrasound-guided fine-needle biopsy (EUS-FNB) represents a standard method for tissue acquisition of lesions adjacent to the gastrointestinal wall. Needles of 19 gauge acquire more tissue than needles with a smaller diameter, but are often unable to penetrate solid, rigid masses. In this study we evaluated a novel prototype that links forward movement of the needle to rotation of the needle tip. Materials and methods Two needle-models that generate either a regular axial movement or a combination of axial movement with rotation of the needle tip were compared ex vivo for measurement of pressure needed to penetrate artificial tissue. Furthermore, a standard 19-gauge EUS-FNB needle was compared to a modified model ("Twist Needle") in an ex vivo model to measure the amount of tissue obtained. Results Pressure measurements using the rotating needle revealed that significantly less pressure is needed for penetration compared to the regular axial movement (mean ± SEM; 3.7 ±â€Š0.3 N vs. 5.5 ±â€Š0.3 N). Using the modified 19-gauge "Twist Needle" did not diminish tissue acquisition measured by surface amount compared to a standard needle (37 ±â€Š5 mm² vs. 35 ±â€Š6 mm²). Conclusion The method of rotation of an EUS-FNB needle tip upon forward movement requires less pressure for penetration but does not diminish tissue acquisition. Hence, the concept of our "Twist Needle" may potentially reduce some of the current limitations of standard EUS-FNB.

11.
J Clin Invest ; 128(11): 5056-5072, 2018 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-30320600

RESUMEN

Dysregulated intestinal epithelial apoptosis initiates gut injury, alters the intestinal barrier, and can facilitate bacterial translocation leading to a systemic inflammatory response syndrome (SIRS) and/or multi-organ dysfunction syndrome (MODS). A variety of gastrointestinal disorders, including inflammatory bowel disease, have been linked to intestinal apoptosis. Similarly, intestinal hyperpermeability and gut failure occur in critically ill patients, putting the gut at the center of SIRS pathology. Regulation of apoptosis and immune-modulatory functions have been ascribed to Thirty-eight-negative kinase 1 (TNK1), whose activity is regulated merely by expression. We investigated the effect of TNK1 on intestinal integrity and its role in MODS. TNK1 expression induced crypt-specific apoptosis, leading to bacterial translocation, subsequent septic shock, and early death. Mechanistically, TNK1 expression in vivo resulted in STAT3 phosphorylation, nuclear translocation of p65, and release of IL-6 and TNF-α. A TNF-α neutralizing antibody partially blocked development of intestinal damage. Conversely, gut-specific deletion of TNK1 protected the intestinal mucosa from experimental colitis and prevented cytokine release in the gut. Finally, TNK1 was found to be deregulated in the gut in murine and porcine trauma models and human inflammatory bowel disease. Thus, TNK1 might be a target during MODS to prevent damage in several organs, notably the gut.


Asunto(s)
Proteínas Fetales/metabolismo , Enfermedades Inflamatorias del Intestino/enzimología , Intestinos/enzimología , Insuficiencia Multiorgánica/enzimología , Traumatismo Múltiple/enzimología , Proteínas Tirosina Quinasas/metabolismo , Síndrome de Respuesta Inflamatoria Sistémica/enzimología , Animales , Modelos Animales de Enfermedad , Femenino , Proteínas Fetales/genética , Enfermedades Inflamatorias del Intestino/etiología , Enfermedades Inflamatorias del Intestino/genética , Enfermedades Inflamatorias del Intestino/patología , Interleucina-6/genética , Interleucina-6/metabolismo , Intestinos/patología , Ratones , Insuficiencia Multiorgánica/etiología , Insuficiencia Multiorgánica/genética , Insuficiencia Multiorgánica/patología , Traumatismo Múltiple/complicaciones , Traumatismo Múltiple/genética , Traumatismo Múltiple/patología , Proteínas Tirosina Quinasas/genética , Factor de Transcripción STAT3/genética , Factor de Transcripción STAT3/metabolismo , Porcinos , Síndrome de Respuesta Inflamatoria Sistémica/etiología , Síndrome de Respuesta Inflamatoria Sistémica/patología , Factor de Transcripción ReIA/genética , Factor de Transcripción ReIA/metabolismo , Factor de Necrosis Tumoral alfa/genética , Factor de Necrosis Tumoral alfa/metabolismo
12.
Z Gastroenterol ; 55(6): 551-556, 2017 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-28591906

RESUMEN

Background Information provided for patients is an essential factor for communication between patients and health-care professionals. To analyze the most used sources of medical information and requested media for patient information, a questionnaire study was initiated. Methods A single-center questionnaire study at an outpatient clinic at a tertiary care hospital. Two hundred participating patients, average age 54.4 years (1:1.5 m:f). Results were displayed in total and as count per participant (i. e., how often is a medium mentioned per participant). Results As a source for general information, printed media are mentioned 112 times (0.56 counts per participant), the Internet 125 (0.62), and television 124 (0.62). As a source for medical information, printed media were mentioned 84 times (0.42) and the Internet 133 (0.67). As the most requested source for additional patient information, printed media were mentioned 105 times (0.53) and medical apps 63 (0.32). Conclusion A majority of our patients regularly use the Internet for medical information. Paper-print media are still highly requested by patients. New media are more often requested in younger patients but still reach the ages for screening programs and therefore offer big opportunities towards patient-doctor communication. By a good mixture of media provided a higher patient satisfaction and adherence could be ensured by the health-care professionals.


Asunto(s)
Atención Ambulatoria/estadística & datos numéricos , Información de Salud al Consumidor/estadística & datos numéricos , Gastroenterología/educación , Internet/estadística & datos numéricos , Medios de Comunicación de Masas/estadística & datos numéricos , Educación del Paciente como Asunto/estadística & datos numéricos , Satisfacción del Paciente/estadística & datos numéricos , Femenino , Alemania/epidemiología , Sistemas de Información en Salud/estadística & datos numéricos , Humanos , Consentimiento Informado/estadística & datos numéricos , Masculino , Persona de Mediana Edad , Folletos , Relaciones Médico-Paciente , Mejoramiento de la Calidad , Encuestas y Cuestionarios
13.
Endoscopy ; 49(8): 808-812, 2017 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-28445902

RESUMEN

Background Adequate polyp detection is crucial to colonoscopy; however, detection can be impaired. In particular, flat polyps located behind folds or near the colonic flexures appear to be a problem. We present a cheap and easily adjustable 3D-printed tool to enhance the view of a standard colonoscope using additional commercially available sideoptics. Materials and methods A cap adjustable to a standard endoscope was printed by a 3 D printer and had two microcameras fixed to offer two additional views. Fourteen endoscopists performed one standard and one sideoptic-enhanced colonoscopy in a randomized order. Flat lesions were simulated in an endoscopy training model. Time for withdrawal was measured, along with the number of flat lesions detected. Results Withdrawal time did not differ significantly between standard and sideoptic-enhanced colonoscopy (329 vs. 389 seconds). The median number of detected flat lesions per endoscopic examination was significantly higher using the sideoptic tool (8 vs. 6.5; P = 0.001). Conclusions A 3D-printed sideoptic-enhanced cap including two microcameras may be a cheap, easy, and feasible add-on to improve adenoma detection rates in routine colonoscopy.


Asunto(s)
Adenoma/diagnóstico por imagen , Neoplasias del Colon/diagnóstico por imagen , Pólipos del Colon/diagnóstico por imagen , Colonoscopía/instrumentación , Impresión Tridimensional , Colonoscopios , Diseño de Equipo , Humanos , Maniquíes , Tempo Operativo , Distribución Aleatoria
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...