Med Phys ; 43(11): 6129, 2016 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-27806609

RESUMEN

PURPOSE: Radiography and tomography using proton beams promise benefit to image guidance and treatment planning for proton therapy. A novel proton tracking detector is described and experimental demonstrations at a therapy facility are reported. A new type of proton CT reconstructing relative "scattering power" rather than "stopping power" is also demonstrated. Notably, this new type of imaging does not require the measurement of the residual energies of the protons. METHODS: A large area, silicon microstrip tracker with high spatial and temporal resolution has been developed by the Proton Radiotherapy Verification and Dosimetry Applications consortium and commissioned using beams of protons at iThemba LABS, Medical Radiation Department, South Africa. The tracker comprises twelve planes of silicon developed using technology from high energy physics with each plane having an active area of ∼10 × 10 cm segmented into 2048 microstrips. The tracker is organized into four separate units each containing three detectors at 60° to one another creating an x-u-v coordinate system. Pairs of tracking units are used to reconstruct vertices for protons entering and exiting a phantom containing tissue equivalent inserts. By measuring the position and direction of each proton before and after the phantom, the nonlinear path for each proton through an object can be reconstructed. RESULTS: Experimental results are reported for tracking the path of protons with initial energies of 125 and 191 MeV. A spherical phantom of 75 mm diameter was imaged by positioning it between the entrance and exit detectors of the tracker. Positions and directions of individual protons were used to create angular distributions and 2D fluence maps of the beam. These results were acquired for 36 equally spaced projections spanning 180°, allowing, for the first time, an experimental CT image based upon the relative scattering power of protons to be reconstructed. CONCLUSIONS: Successful tracking of protons through a thick target (phantom) has demonstrated that the tracker discussed in this paper can provide the precise directional information needed to perform proton radiography and tomography. When synchronized with a range telescope, this could enable the reconstruction of proton CT images of stopping power. Furthermore, by measuring the deflection of many protons through a phantom, it was demonstrated that it is possible to reconstruct a new kind of CT image (scattering power) based upon this tracking information alone.


Asunto(s)
Procesamiento de Imagen Asistido por Computador/métodos , Protones , Silicio , Tomografía Computarizada por Rayos X , Humanos , Radiometría
2.
Nucl Instrum Methods Phys Res A ; 831: 362-366, 2016 Sep 21.
Artículo en Inglés | MEDLINE | ID: mdl-27667884

RESUMEN

For many years, silicon micro-strip detectors have been successfully used as tracking detectors for particle and nuclear physics experiments. A new application of this technology is to the field of particle therapy where radiotherapy is carried out by use of charged particles such as protons or carbon ions. Such a treatment has been shown to have advantages over standard x-ray radiotherapy and as a result of this, many new centres offering particle therapy are currently under construction around the world today. The Proton Radiotherapy, Verification and Dosimetry Applications (PRaVDA) consortium are developing instrumentation for particle therapy based upon technology from high-energy physics. The characteristics of a new silicon micro-strip tracker for particle therapy will be presented. The array uses specifically designed, large area sensors with technology choices that follow closely those taken for the ATLAS experiment at the HL-LHC. These detectors will be arranged into four units each with three layers in an x-u-v configuration to be suitable for fast proton tracking with minimal ambiguities. The sensors will form a tracker capable of tracing the path of ~200 MeV protons entering and exiting a patient allowing a new mode of imaging known as proton computed tomography (pCT). This will aid the accurate delivery of treatment doses and in addition, the tracker will also be used to monitor the beam profile and total dose delivered during the high fluences used for treatment. We present here details of the design, construction and assembly of one of the four units that will make up the complete tracker along with its characterisation using radiation tests carried out using a 90Sr source in the laboratory and a 60 MeV proton beam at the Clatterbridge Cancer Centre.

3.
J Instrum ; 102015 Jun 03.
Artículo en Inglés | MEDLINE | ID: mdl-29225666

RESUMEN

Since the first proof of concept in the early 70s, a number of technologies has been proposed to perform proton CT (pCT), as a means of mapping tissue stopping power for accurate treatment planning in proton therapy. Previous prototypes of energy-range detectors for pCT have been mainly based on the use of scintillator-based calorimeters, to measure proton residual energy after passing through the patient. However, such an approach is limited by the need for only a single proton passing through the energy-range detector in a read-out cycle. A novel approach to this problem could be the use of pixelated detectors, where the independent read-out of each pixel allows to measure simultaneously the residual energy of a number of protons in the same read-out cycle, facilitating a faster and more efficient pCT scan. This paper investigates the suitability of CMOS Active Pixel Sensors (APSs) to track individual protons as they go through a number of CMOS layers, forming an energy-range telescope. Measurements performed at the iThemba Laboratories will be presented and analysed in terms of correlation, to confirm capability of proton tracking for CMOS APSs.

4.
J Instrum ; 102015 Feb 10.
Artículo en Inglés | MEDLINE | ID: mdl-29367858

RESUMEN

For many years, silicon micro-strip detectors have been successfully used as tracking detectors for particle and nuclear physics experiments. A new application of this technology is to the field of particle therapy, where radiotherapy is carried out by use of charged particles such as protons or carbon ions. Such a treatment has been shown to have advantages over standard x-ray radiotherapy and as a result of this, many new centres offering particle therapy are currently under construction - including two in the U.K.. The characteristics of a new silicon micro-strip detector based system for this application will be presented. The array uses specifically designed large area sensors in several stations in an x-u-v co-ordinate configuration suitable for very fast proton tracking with minimal ambiguities. The sensors will form a tracker capable of giving information on the path of high energy protons entering and exiting a patient. This will allow proton computed tomography (pCT) to aid the accurate delivery of treatment dose with tuned beam profile and energy. The tracker will also be capable of proton counting and position measurement at the higher fluences and full range of energies used during treatment allowing monitoring of the beam profile and total dose. Results and initial characterisation of sensors will be presented along with details of the proposed readout electronics. Radiation tests and studies with different electronics at the Clatterbridge Cancer Centre and the higher energy proton therapy facility of iThemba LABS in South Africa will also be shown.

5.
Appl Opt ; 34(4): 695-702, 1995 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-20963171

RESUMEN

We present a technique we developed to measure specular reflectances of mirrors immersed in liquids and in air. The method works with a broad range of angles of incidence (θ = 15-75°). The wavelength range used in this research was from 250 to 800 nm, and the state of polarization of the incident rays could be continuously varied with respect to the phase of incidence. The technique used in this study is based on a low-cost variable-angle reflectometer and a commercial spectrophotometer. Here we discuss the protocol we devised to extract reflectances with this instrument. This procedure was tested with samples that were measured through the use of ellipsometric techniques. The main advantages of the method discussed here are versatility, speed, and the availability of the equipment used; these are particularly useful for controlling the quality of a large number of samples. We present the results of reflectance measurements in water for dielectric coated aluminum intended for use in light concentrators for the Sudbury Neutrino Observatory. The error in our estimate of the overall reflectance, weighted over operational distributions of wavelength and incident angle, is ±3% for one sample and ±5% for the 2000 m(2) of coated material involved in this observatory.

6.
Appl Opt ; 33(31): 7536-40, 1994 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-20941320

RESUMEN

There is a growing class of elementary particle detectors, large-water Cerenkov detectors, that have a body of water (thousands of tons) as a sensitive medium. Particles are detected when they interact with the water and produce Cerenkov light, so detection efficiency relies on the transparency of the water. These detectors are active typically for many years, so biological activity (primarily bacterial growth) is one of the means by which the transparency of the water may be reduced. We present the results of a measurement of light scattering and absorption from a population of Escherichia coli in water, which is used as a model for bacteria in general. One can separate the scattering and absorption by varying the refractive index of the medium by using a solute of high molecular weight. We show that the results can be understood simply in terms of light scattering from small spheres (radius ≈ wavelength) with an effective refractive index, n(b), plus a small amount of absorption in the ultraviolet. We compare his scattering with Rayleigh scattering in pure water.

9.
Appl Opt ; 31(13): 2360-5, 1992 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-20720901

RESUMEN

We present a method of fabricating nonimaging light concentrators from total internal reflection film. A prototype has been made and tested and found to operate in agreement with predictions of ray-tracing codes. The performance of the prototype is comparable with that of concentrators made from specular reflecting materials.