J Acoust Soc Am ; 126(6): 3049-56, 2009 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-20000918

RESUMEN

The time domain implementation of the transfer-matrix method developed by Song and Bolton [J. Acoust. Soc. Am. 107, 1131-1154 (2000)] for measuring the characteristic impedance and wave number of porous materials is described in this paper. The so called Butterworth impulse is generated in a standing wave tube with a flat frequency response over a wide frequency range. With only two microphone measurements, the transfer matrix of porous layers can easily be determined through the calculation of complex amplitudes of incident, reflected, and transmitted pulses. The procedure has been used to measure the acoustical properties of a fiber material, and good agreement was found between measured acoustical properties and predicted results by Delany and Bazley [Appl. Acoust. 3, 105-116 (1971)] semiempirical formulas. Although the error associated with the sample-edge constraint still remains, the new method has a better frequency response as a result of the system calibration process, and the optimal inter-microphone distance is no longer required compared to the frequency domain implementation.