Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Langmuir ; 40(16): 8678-8684, 2024 Apr 23.
Artículo en Inglés | MEDLINE | ID: mdl-38606578

RESUMEN

The practical use of lithium-sulfur batteries faces the "shuttle effect" and lithium dendrite growth. Employing SiO instead of Li metal can fundamentally solve the above problems. Nevertheless, selecting a convenient prelithiation method is essential for normal operation of the battery system. Hence, this work proposed a novel SiO-sulfur battery with preloaded Li3N in a cathode as a prelithiation reagent, which can thoroughly solve the dendrite problem and the side reaction with polysulfides of lithium anode. The S@KB-Li3N vs SiO full cell can obtain a high specific capacity of 790 mAh g-1 after the activation process and be maintained at 478 mAh g-1 after 100 cycles. Our design will provide a new prelithiation strategy for a high-specific-energy SiO-sulfur battery system.

2.
J Colloid Interface Sci ; 649: 175-184, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37348337

RESUMEN

Lithium-rich manganese-based cathode has made a subject of intense scrutiny for scientists and application researchers due to their exceptional thermal stability, high specific capacity, high operating voltage, and cost-effectiveness. However, the inclusion of cobalt, as a crucial component in lithium-rich manganese-based cathode materials, has become a cause for concern due to its limited availability and non-renewable nature, which eventually limits the growth of the battery industry and increase costs. Considering the poor stability of cobalt-free cathode, this work proposes a coating strategy of LiF through a simple high-temperature melting method. Directly coating LiF on Li1.2Ni0.2Mn0.6O2 surface is found to be an effective way to protect the cathode material, decrease metal solubility, and inhibit irreversible phase transition processes, thus leading to an improved electrochemical performance. As a result, the battery employing LiF coated Li1.2Ni0.2Mn0.6O2 cathode can be stabilized over 280 cycles and maintain a capacity of 110 mAh g-1 at 1C. What's more, the mechanisms of ion insertion/extraction behavior and ion migration process are also studied systematically. This study will open the avenue to develop a high-energy battery system with cobalt-free cathode.

3.
Front Pediatr ; 10: 954337, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36299698

RESUMEN

Objective: This study examines the distribution and development of intraocular pressure (IOP) in infants aged from 0 to 36 months and analyzes its correlation with corneal diameter. Methods: The study used a retrospective case analysis methodology. Healthy infants treated in the ophthalmology department of Hebei Children's Hospital from December 2012 to December 2020 were included in the study. Among these infants, 385 had their IOP measured, and 432 had their corneal diameters measured. Furthermore, information such as birth history, growth and development, IOP, and corneal diameter were collected. Their IOPs were measured with an iCare portable rebound tonometer when the child was awake and calm, and the corneal diameter was measured with a Castroviejo caliper under chloral hydrate sedation. The infants were divided into five groups according to age, and SPSS statistical software was used to analyze, compare, and correlate IOP and corneal diameter variations. Results: The mean IOP values of 0-1 month, 1-6 months, 6-12 months, 12-24 months and 24-36 months groups were 7.42 ± 1.92, 9.10 ± 2.85, 12.00 ± 3.15, 13.72 ± 3.09, and 15.14 ± 2.67 mmHg, respectively. The differences in IOP of the 0-1 month old infants and the 1-6 months old infants with the other three groups were statistically significant; the difference in IOP between the 6-12 months group and the 24-36 months group was statistically significant. In the studied groups, the horizontal corneal diameters were 9.78 ± 0.14, 10.50 ± 0.29, 10.86 ± 0.23, 11.38 ± 0.07, and 11.72 ± 0.04 mm, respectively, and the vertical diameters of the cornea were 9.28 ± 0.26, 10.07 ± 0.18, 10.28 ± 0.14, 10.56 ± 0.24, and 10.85 ± 0.03 mm, respectively. The differences in the vertical and horizontal diameters of the cornea among the groups were statistically significant. Conclusion: Infants' IOP and corneal diameter positively correlate with age, and they peak in the first 12 months.

4.
Int J Ophthalmol ; 15(9): 1423-1430, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36124184

RESUMEN

AIM: To identify potential mutations and elucidate the clinical findings of male patients and female carriers of X-linked retinitis pigmentosa (XLRP) in a Chinese family. METHODS: A four generation pedigree was collected that consisted of 20 individuals. Genomic DNA was extracted from peripheral blood, and then the target fragments were amplified by PCR and sequenced directly. In addition, all affected patients and female carriers underwent comprehensively ophthalmic evaluation. RESULTS: A novel mutation c.2865G>A p.W955X in RPGR gene was identified of this family, including four affected individuals and eight carriers. All male patients, aging from 7 to 31y, tended to have more various, even potentially deleterious clinical features of RP. At the same time, individuals with heterozygous mutations (carriers) manifested a wide spectrum of clinical features. Herein, only two male patients and three female carriers manifested pathological myopia (PM). Among the female carriers, half of subjects who harbor poor visual acuity suffered esotropia or exotropia. Additionally, 16.7% and 66.7% of carriers had abnormal electroretinogram (ERG) and fundus, respectively. CONCLUSION: In this study, a novel mutation of the RPGR gene is identified, which broadens the spectrum of RPGR mutations, and elaborates the relationship between genotype and phenotype.

7.
J Ophthalmol ; 2014: 756059, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-25538849

RESUMEN

Purpose. To understand the current status of retinopathy of prematurity (ROP) screening in a province of North China. Methods. We retrospectively analyzed 5651 cases with ROP screening in the Provincial Screening Center of Hebei Province from January 2008 to December 2013. Results. 14.98% of all ROP patients and 1.56% of severe ROP patients required treatment. All the severe ROP patients met the criteria of screening. Severe ROP patients were detected at recommended initial screening time (4-6 weeks after birth). The frequency of other ocular diseases was 8.03%, in which the main disease was fundus hemorrhage. In 2665 more mature and unqualified infants, only 2 retinoblastoma and 2 familial exudative vitreoretinopathy were detected, which indicates the advantage of early diagnosis and treatment based on fundus examination. Conclusions. It is suggested that the standard of GA < 32 weeks and/or BW < 1800 g could be served as the screening criteria in the local region for ROP screening. 4 weeks after birth is the most appropriate time for initial screening.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA