Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
J Biomed Mater Res B Appl Biomater ; 112(8): e35458, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-39122663

RESUMEN

Bacterial infections already pose a significant threat to skin wounds, especially in diabetic patients who have difficulty healing wounds. However, wound or bacterial infections are known to produce excess reactive oxygen species (ROS), and hypoxia may further hinder wound healing and the development of chronic wounds. In this study, a multifunctional hydrogel for ROS scavenging and bacterial inhibition was developed by cross-linking polyvinyl alcohol (PVA) and sodium alginate (SA) with graphene oxide (GO) loaded with silver-platinum hybrid nanoparticles (GO@Ag-Pt). The PVA/SA hydrogel loaded with GO@Ag-Pt exhibited the ability to scavenge different types of ROS, generate O2, and kill a broad spectrum of bacteria in vitro. The silver-platinum hybrid nanoparticles significantly increased the antibacterial ability against Escherichia coli and Staphylococcus aureus compared with silver nanoparticles (AgNps). GO@Ag-Pt loaded hydrogel was effective in treating infections caused by S.aureus, thereby significantly promoting wound healing during the inflammatory phase. Hydrogel therapy significantly reduced the level of ROS and alleviated inflammation levels. Notably, our ROS-scavenging, antibacterial hydrogels can be used to effectively treat various types of wounds, including difficult-to-heal diabetic wounds with bacterial infections. Thus, this study proposes an effective strategy for various chronic wound healing based on ROS clearance and bacteriostatic hydrogels.


Asunto(s)
Antibacterianos , Escherichia coli , Hidrogeles , Nanopartículas del Metal , Especies Reactivas de Oxígeno , Plata , Staphylococcus aureus , Cicatrización de Heridas , Especies Reactivas de Oxígeno/metabolismo , Cicatrización de Heridas/efectos de los fármacos , Hidrogeles/química , Hidrogeles/farmacología , Antibacterianos/farmacología , Antibacterianos/química , Staphylococcus aureus/efectos de los fármacos , Animales , Nanopartículas del Metal/química , Plata/química , Plata/farmacología , Escherichia coli/efectos de los fármacos , Ratones , Grafito/química , Grafito/farmacología , Inflamación/tratamiento farmacológico , Alcohol Polivinílico/química , Alcohol Polivinílico/farmacología , Humanos , Alginatos/química , Alginatos/farmacología , Infección de Heridas/tratamiento farmacológico , Infecciones Estafilocócicas/tratamiento farmacológico , Masculino , Oxígeno/química , Depuradores de Radicales Libres/farmacología , Depuradores de Radicales Libres/química
2.
Biomed Environ Sci ; 37(6): 639-646, 2024 Jun 20.
Artículo en Inglés | MEDLINE | ID: mdl-38988114

RESUMEN

Objective: To develop a highly sensitive and rapid nucleic acid detection method for the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). Methods: We designed, developed, and manufactured an integrated disposable device for SARS-CoV-2 nucleic acid extraction and detection. The precision of the liquid transfer and temperature control was tested. A comparison between our device and a commercial kit for SARS-Cov-2 nucleic acid extraction was performed using real-time fluorescence reverse transcription polymerase chain reaction (RT-PCR). The entire process, from SARS-CoV-2 nucleic acid extraction to amplification, was evaluated. Results: The precision of the syringe transfer volume was 19.2 ± 1.9 µL (set value was 20), 32.2 ± 1.6 (set value was 30), and 57.2 ± 3.5 (set value was 60). Temperature control in the amplification tube was measured at 60.0 ± 0.0 °C (set value was 60) and 95.1 ± 0.2 °C (set value was 95) respectively. SARS-Cov-2 nucleic acid extraction yield through the device was 7.10 × 10 6 copies/mL, while a commercial kit yielded 2.98 × 10 6 copies/mL. The mean time to complete the entire assay, from SARS-CoV-2 nucleic acid extraction to amplification detection, was 36 min and 45 s. The detection limit for SARS-CoV-2 nucleic acid was 250 copies/mL. Conclusion: The integrated disposable devices may be used for SARS-CoV-2 Point-of-Care test (POCT).


Asunto(s)
COVID-19 , Equipos Desechables , ARN Viral , SARS-CoV-2 , SARS-CoV-2/aislamiento & purificación , COVID-19/diagnóstico , COVID-19/virología , Humanos , ARN Viral/aislamiento & purificación , ARN Viral/análisis , Prueba de Ácido Nucleico para COVID-19/instrumentación , Prueba de Ácido Nucleico para COVID-19/métodos , Técnicas de Amplificación de Ácido Nucleico/instrumentación , Técnicas de Amplificación de Ácido Nucleico/métodos , Reacción en Cadena en Tiempo Real de la Polimerasa/métodos , Reacción en Cadena en Tiempo Real de la Polimerasa/instrumentación
3.
J Chromatogr A ; 1731: 465198, 2024 Aug 30.
Artículo en Inglés | MEDLINE | ID: mdl-39059303

RESUMEN

Exploiting high-performance magnetic beads for specific enrichment of ribonucleic acid (RNA) has important significance in the biomedical research field. Herein, a simple strategy was proposed for fabricating boronate-decorated polyethyleneimine-grafted magnetic agarose beads (BPMAB), which can selectively isolate cis-diol-containing substances through boronate affinity. The size of the basic magnetic agarose beads was controlled through the emulsification of the water-in-oil emulsion with a high-speed shear machine, which enhanced the specific surface area of BPMAB. Subsequently, to modify more boronic acid ligands, branched PEI with excellent hydrophilicity and numerous reaction sites was grafted. 2,4-Difluoro-3-formylphenyl boronic acid (2,4-DFPBA) was covalently immobilized for selectively capturing cis-diol-containing substances under physiological condition (pH 7.4). The BPMAB with a diameter range from 1.86 µm to 11.60 µm possessed clearly spherical structure, and excellent magnetic responsiveness and suspension ability in aqueous solution. ß-Nicotinamide adenine dinucleotide (ß-NAD), a short-chain cis-diol carrying agent, was selected as a target molecule for evaluating the adsorption property of BPMAB and the maximum adsorption capacity of BPMAB for ß-NAD could reach 205.11 mg g-1. In addition, the BPMAB as adsorbent was used to selectively enrich RNA from mammalian cells. The maximum adsorption capacity of BPMAB for RNA was 140.50 mg g-1. Under optimized conditions, the BPMAB-based MSPE successfully enriched the high-quality total RNA with 28S to 18S ribosomal RNA ratios ranging from 2.06 to 2.16. According to the PCR analysis of GADPH gene, the extracted total RNA was successfully reverse transcribed into cDNA. Therefore, we believe that the BPMAB-based MSPE could be applicable for the specific enrichment of RNA from complex biological systems.


Asunto(s)
Ácidos Borónicos , Polietileneimina , ARN , Sefarosa , Ácidos Borónicos/química , Polietileneimina/química , Sefarosa/química , ARN/química , Humanos , Adsorción , Animales , Tamaño de la Partícula
4.
J Chromatogr A ; 1724: 464923, 2024 Jun 07.
Artículo en Inglés | MEDLINE | ID: mdl-38653039

RESUMEN

Efficient separation of deoxyribonucleic acid (DNA) through magnetic nanoparticles (MN) is a widely used biotechnology. Hedgehog-inspired MNs (HMN) possess a high-surface-area due to the distinct burr-like structure of hedgehog, but there is no report about the usage of HMN for DNA extraction. Herein, to improve the selection of MN and illustrate the performance of HMN for DNA separation, HMN and silica-coated Fe3O4 nanoparticles (Fe3O4@SiO2) were fabricated and compared for the high-efficient separation of pathogenic bacteria of DNA. Escherichia coli (E. coli) and Staphylococcus aureus (S. aureus) are typical Gram-negative and Gram-positive bacteria and are selected as model pathogenic bacteria. To enhance the extraction efficiency of two kinds of MNs, various parameters, including pretreatment, lysis, binding and elution conditions, have been optimized in detail. In most separation experiments, the DNA yield of HMN was higher than that of Fe3O4@SiO2. Therefore, a HMN-based magnetic solid-phase microextraction (MSPE) and quantitative real-time PCR (qPCR) were integrated and used to detect pathogenic bacteria in real samples. Interestingly, the HMN-based MSPE combined qPCR strategy exhibited high sensitivity with a limit of detection of 2.0 × 101 CFU mL-1 for E. coli and 4.0 × 101 CFU mL-1 for S. aureus in orange juice, and 2.8 × 102 CFU mL-1 for E. coli and 1.1 × 102 CFU mL-1 for S. aureus in milk, respectively. The performance of the proposed strategy was significantly better than that of commercial kit. This work could prove that the novel HMN could be applicable for the efficient separation of DNA from complex biological samples.


Asunto(s)
ADN Bacteriano , Escherichia coli , Nanopartículas de Magnetita , Microextracción en Fase Sólida , Staphylococcus aureus , Staphylococcus aureus/aislamiento & purificación , Staphylococcus aureus/química , Escherichia coli/química , Escherichia coli/aislamiento & purificación , Nanopartículas de Magnetita/química , ADN Bacteriano/aislamiento & purificación , ADN Bacteriano/análisis , Microextracción en Fase Sólida/métodos , Dióxido de Silicio/química , Reacción en Cadena en Tiempo Real de la Polimerasa , Límite de Detección , Erizos/microbiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA