J Radiol Prot ; 2024 Jul 24.
Artículo en Inglés | MEDLINE | ID: mdl-39047756

RESUMEN

This study reports the performance of 7 types of consumer grade passive Electronic Radon Integrating Monitors, ERIM (AlphaE, AER Plus, Canary, Corentium Pro, Radon Scout Home, Ramon and Wave) and passive etched track radon detectors. All monitors and passive radon detectors were exposed side by side for 2 periods of 3 months under controlled conditions in the UKHSA radon chamber and in a stainless steel container to an average radon concentration of 4781 Bq m-3 and 166 Bq m-3, respectively. The performance of each individual monitor was compared with Atmos 12DPX and AlphaGUARD P30 reference instruments. The performance of the monitors was evaluated by estimating the biased, precision and measurement errors of each type. It was found that UKHSA passive radon detectors showed excellent performance (measurement error < 10%) at both higher and lower exposures. The AlphaE, Canary and Ramon showed excellent performance, with measurement error < 10%, when they were exposed to radon concentrations between 4000 Bq m-3 and 6000 Bq m-3 in the UKHSA radon chamber. However, when the monitors were exposed to radon levels below the UK radon Action Level of 200 Bq m-3, the only ERIM which had a measurement error <10% was the Radon Scout Home. All other monitors showed a significant decrease in their performance with measurement errors ranging between 20% and 50%. The calibration factor, which is the ratio between the measured value (background is subtracted) and the reference value, was also studied. It was found that the calibration factors of individual monitors changed significantly. Calibration measurements in 2019 and in 2023 found that the percentage change varied between -46% and +63%. This shows the importance of initial and regular calibration, and maintenance of the monitors. .

2.
Radiat Prot Dosimetry ; 177(1-2): 140-143, 2017 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-28981884

RESUMEN

The Vale of Pickering in Yorkshire, England has been identified as a potential area for shale gas extraction. Public Health England joined a collaboration led by the British Geological Survey for environmental baseline monitoring near the potential shale gas extraction site following a grant award from UK Government Department for Business, Energy and Industrial Strategy. The analysis of results for the first 6 months of indoor monitoring indicated that the results followed a log-normal distribution. The numbers of homes found to be at or above the Action Level followed the numbers predicted by the radon potential maps. The results from the measurements of outdoor air in this study indicated that the radon concentrations are slightly higher than previously measured but close to the detection limit of the technique.


Asunto(s)
Contaminantes Radiactivos del Aire/análisis , Contaminación del Aire Interior/análisis , Contaminación Radiactiva del Aire/análisis , Exposición a Riesgos Ambientales/análisis , Sedimentos Geológicos/análisis , Monitoreo de Radiación/métodos , Inglaterra , Vivienda , Humanos , Radón/análisis
3.
Med Device Technol ; 18(6): 30, 32-5, 2007 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-18078180

RESUMEN

Recent work on modifying silicone rubber to improve water permeability and biocompatibility is described. In addition, modifications to the interface between an active implanted device and the body are reported, which have led to reduced power consumption and improved device performance.


Asunto(s)
Materiales Biocompatibles/química , Biotecnología/tendencias , Diseño de Equipo/tendencias , Equipos y Suministros , Ensayo de Materiales , Estados Unidos