Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
RSC Adv ; 13(35): 24801-24804, 2023 Aug 11.
Artículo en Inglés | MEDLINE | ID: mdl-37608968

RESUMEN

Supervised classification of handwritten digits via physical reservoir computing (PRC) using electrochemistry with a three-electrode electrochemical setup was demonstrated. Short-term memory required for the PRC was realized for 3 bit pulse patterns by adjusting the formation/reduction ratio of gold oxides, showing a wide potential of electrochemistry as resources of PR devices.

2.
J Vasc Surg Cases Innov Tech ; 8(4): 748-751, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-36438668

RESUMEN

We have presented the case of a 76-year-old patient with a type V thoracoabdominal aortic aneurysm treated by retrograde in situ branched stent grafting to the superior mesenteric artery (SMA). Via a 9-cm, median laparotomy, a percutaneous transhepatic gallbladder drainage needle was inserted from the distal part of the first jejunal artery to the origin of the SMA. After stent graft placement into the aorta, the graft was retrogradely punctured using the percutaneous transhepatic gallbladder drainage needle. The SMA ischemic time was 6 minutes. The puncture site was dilated, and a small, covered stent was deployed. Postoperative computed tomography scanning showed no endoleak with sac regression.

3.
J Endovasc Ther ; : 15266028221131450, 2022 Oct 27.
Artículo en Inglés | MEDLINE | ID: mdl-36300538

RESUMEN

PURPOSE: To demonstrate the efficacy of a combination of Amplatzer vascular plug (AVP2) and Endologix AFX for a visceral entry closure. CASE REPORT: A 70-year-old woman with treated chronic type B aortic dissection was seen to have sac enlargement. An isolated residual tear was observed at the origin of the celiac artery. A 12 mm AVP2 was successfully deployed for the entry closure. Angiography after the plug deployment still demonstrated residual flow to the false lumen. Hence, an Endologix AFX VELA proximal endograft was deployed, covering the AVP membrane and leaving no endoleak. CONCLUSION: Deployment of a vascular plug with Endologix AFX lining was efficacious for securing complete closure of an entry tear at the origin of the celiac artery in our patient. CLINICAL IMPACT: Vascular plugs are reported to be effective for closing small entries, although their effectiveness is limited when the entry site is not located on the flat intima, or in a high-flow situation. In the presented case, an isolated entry tear at the origin of the celiac artery was successfully closed with a vascular plug following Endologix AFX stent-graft lining of the true lumen.

4.
J Card Surg ; 36(10): 3933-3935, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-34291837

RESUMEN

A 74-year-old woman developed inferior myocardial infarction due to right coronary artery occlusion and underwent percutaneous coronary intervention. Two days later, echocardiography revealed ventricular septal rupture, and Impella CP was inserted to avoid emergency surgery. However, the patient's hemodynamics deteriorated rapidly, necessitating additional venoarterial extracorporeal membranous oxygenation support with concomitant Impella support (ECPELLA). The ventricular septal rupture was surgically repaired using the extended sandwich technique via a right ventricular approach; the ascending aorta was clamped with the clampable portion of the Impella. The patient was successfully weaned from the Impella 3 days postsurgery. This case suggests that urgent surgery with ECPELLA support could be a useful option for patients with ventricular septal rupture, even in severe cases wherein emergency surgery is unavoidable.


Asunto(s)
Oxigenación por Membrana Extracorpórea , Rotura Septal Ventricular , Anciano , Ecocardiografía , Femenino , Ventrículos Cardíacos , Hemodinámica , Humanos , Rotura Septal Ventricular/etiología , Rotura Septal Ventricular/cirugía
5.
Polymers (Basel) ; 10(10)2018 Sep 29.
Artículo en Inglés | MEDLINE | ID: mdl-30961008

RESUMEN

Poly-l-lactic acid (PLLA) has biocompatibility and unique characteristics such as piezoelectric properties. This attracts attention not only in the environmental field but also in the biomedical and electronic materials fields. In recent years, the literature about orienting PLLA crystals has been promoting new applications for PLLA such as high strength fiberization and piezoelectric properties. This paper presents a new technique to orient the PLLA crystalline through casting under magnetic irradiation. The advantage of this technique is that it is possible to radiate the magnetic field to the PLLA crystalline in an extremely low viscosity environment. Moreover, the heat treatment condition was optimized in order to improve the low crystallinity of casting, and it succeeded in producing a PLLA film with a high degree of orientation and high crystallinity. Furthermore, PLLA/1-butyl-3-methylimidazolium dibutylphosphate (bmimjdbp) composite films were prepared under the same conditions, and this also succeeded in the further improvement of crystallinity.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...