Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
J Clin Anesth ; 8(8): 656-8, 1996 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-8982894

RESUMEN

Multiple reports of cauda equina syndrome and transient radicular nerve root irritation have suggested that lidocaine spinal anesthesia may be responsible. In this case report, a patient with a preexisting diabetic neuropathy received a partial block following a tetracaine spinal, which was followed by a lidocaine spinal. Following block resolution, a new conus medullaris syndrome was diagnosed. Because of the close proximity of the cauda equina and the conus medullaris, differentiation between these syndromes can be difficult. The preexisting diabetic neuropathy may have predisposed this patient to neurologic injury. The choice of a different local anesthetic drug with less neurotoxic potential such as bupivacaine may have prevented this injury.


Asunto(s)
Anestesia Raquidea/efectos adversos , Anestésicos Locales/efectos adversos , Lidocaína/efectos adversos , Compresión de la Médula Espinal/inducido químicamente , Médula Espinal/efectos de los fármacos , Tetracaína/efectos adversos , Bupivacaína/administración & dosificación , Cauda Equina , Circuncisión Masculina , Diabetes Mellitus Tipo 1/complicaciones , Neuropatías Diabéticas/complicaciones , Procedimientos Quirúrgicos Electivos , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Bloqueo Nervioso/efectos adversos , Síndromes de Compresión Nerviosa/diagnóstico
2.
J Air Waste Manag Assoc ; 45(1): 29-35, 1995 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-15658164

RESUMEN

This paper describes a portable, low-cost whole air sampler capable of collecting 12 1-L samples in tedlar bags and using a single "D" cell for power. The results are presented from two tests of an intensive sampling and analysis method for measuring ambient carbon monoxide (CO) concentrations in urban areas using this sampler. The method is evaluated in comparison with an approved continuous CO analyzer, in intercomparisons of the results of re-analysis of the samples, and by examination of the results from co-located samplers. The precision of the analytical method was found to be +/-0.30 ppmv. The precision of the sampling method was found to be +/-0.73 ppmv and therefore is the limiting factor in the method's overall precision. These values are sufficient to verify attainment of National Ambient Air Quality Standards (NAAQS) levels in urban areas. Improvements in the sampler and analytical procedure are discussed.


Asunto(s)
Contaminantes Atmosféricos/análisis , Monóxido de Carbono/análisis , Monitoreo del Ambiente/instrumentación , Automatización , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA