Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
J Am Vet Med Assoc ; 221(4): 541-5, 2002 Aug 15.
Artículo en Inglés | MEDLINE | ID: mdl-12184706

RESUMEN

OBJECTIVE: To report the postoperative outcome in horses undergoing jejunoileal anastomosis performed with a 2-layer simple continuous technique. DESIGN: Retrospective study. ANIMALS: 7 horses. PROCEDURE: Information regarding signalment, clinical signs, findings at surgery, and postoperative complications was obtained from medical records of horses that underwent exploratory ventral midline celiotomy, small intestinal resection, and jejunoileal anastomosis to correct various small intestinal strangulating lesions. Follow-up information was obtained via telephone conversations with owners or trainers. RESULTS: Six males and 1 female of various breeds aged 10 months to 27 years and weighing 312 to 785 kg (686.4 to 1,727 lb) were included. The most common complications were mild to moderate tachycardia and mild to moderate signs of abdominal pain. Two horses developed incisional infections and soft, fluctuant swelling at the incision site following resolution of the infection. Follow-up time ranged from 7 to 17 months after surgery. Owners reported no further colic episodes and no diet change necessary following surgery. All horses had returned to their intended level of use. CONCLUSIONS AND CLINICAL RELEVANCE: Advantages to the jejunoileal technique include maintaining the normal ileocecal valve and a postoperative recovery period similar to that described following other small intestinal anastomoses. Jejunoileal anastomosis is a viable alternative to ileal bypass. This technique appears to result in a postoperative complication rate similar to that reported following jejunojejunostomy procedures.


Asunto(s)
Enfermedades de los Caballos/cirugía , Íleon/cirugía , Obstrucción Intestinal/veterinaria , Yeyuno/cirugía , Complicaciones Posoperatorias/veterinaria , Dolor Abdominal/etiología , Dolor Abdominal/veterinaria , Anastomosis Quirúrgica/métodos , Anastomosis Quirúrgica/veterinaria , Animales , Femenino , Caballos , Obstrucción Intestinal/cirugía , Masculino , Estudios Retrospectivos , Taquicardia/etiología , Taquicardia/veterinaria , Resultado del Tratamiento
3.
Vet Surg ; 31(1): 85-93, 2002.
Artículo en Inglés | MEDLINE | ID: mdl-11778172

RESUMEN

OBJECTIVE: To compare the biomechanical characteristics and mode of failure of two different dynamic compression plate (DCP) techniques for proximal interphalangeal joint (PIPJ) arthrodesis in horses. STUDY DESIGN: Randomized block-design blocking on horse (1-5), method of fixation (two 7-hole, 3.5-mm broad DCP vs two 5-hole, 4.5-mm narrow DCP), side (left, right), and end (front, hind). Constructs were loaded to failure in 3-point bending in a dorsal-to-palmar (plantar) direction. SAMPLE POPULATION: Ten paired limbs from 5 equine cadavers. METHODS: Two 7-hole, 3.5-mm broad dynamic compression plates (bDCP) were used in 1 limb of a pair, and two 5-hole 4.5-mm narrow dynamic compression plates (nDCP) were used on the contralateral limb. Plates were positioned abaxially across the dorsomedial and dorsolateral aspect of the PIPJ. Arthrodesis constructs were loaded (19 mm/s) in 3-point bending in a dorsal-to-palmar (plantar) direction using a materials-testing machine. Composite stiffness, yield point, and maximal bending moment at failure were obtained from bending moment-angular deformation curves. Data were analyzed using ANOVA, X(2) analysis, and Fisher's exact tests; the power of the test was calculated when differences were not significant. RESULTS: There were no significant differences in composite stiffness (P >.05; power = 0.8 @ delta = 21.9%), yield point (P >.05; power = 0.8 @ delta = 34.4%), or maximal bending moment (P >.05; power = 0.8 @ delta = 17.8%) between the two fixation techniques. For bDCP constructs, 11% (15 of 140) of the 3.5-mm screws were damaged; 7 of the screw heads pulled through plates where the plates bent, 1 screw head broke off, and 7 screws were bent or pulled out of the phalanx. For nDCP constructs, 8% (8 of 100) of the 4.5-mm screws were damaged; 1 screw head pulled through a plate, 1 screw head broke off, and 6 screws were bent or pulled out of the phalanx. CONCLUSIONS: There were no biomechanical or failure differences between bDCP and nDCP fixation of the PIPJ in horses when evaluated in single-cycle 3-point bending to failure. CLINICAL RELEVANCE: There is no biomechanical advantage to the use of two 7-hole, 3.5-mm bDCP in equine proximal interphalangeal arthrodesis compared with two 5-hole, 4.5-mm nDCP. Two 5-hole, 4.5-mm nDCP may be easier to place, whereas two 7-hole, 3.5-mm bDCP may provide more versatility in fracture repair.


Asunto(s)
Artrodesis/veterinaria , Placas Óseas/veterinaria , Caballos/cirugía , Articulación del Dedo del Pie/cirugía , Animales , Artrodesis/instrumentación , Fenómenos Biomecánicos , Diseño de Equipo , Miembro Anterior , Miembro Posterior , Caballos/lesiones , Articulación del Dedo del Pie/lesiones
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA