Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
J Arthroplasty ; 37(12): 2406-2411, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-35738363

RESUMEN

BACKGROUND: Revision total hip arthroplasty (THA) for adverse local tissue reactions (ALTRs) secondary to head-neck taper corrosion is associated with a high complication rate. Diagnosis of ALTR is based on risk stratification using the patient's history and examination, implant risk, serum metal ion levels, and imaging. The purpose of this study was to determine if stratification using similar risk factors is predictive of outcomes following revision THA for metal-on-polyethylene (MoP) ALTR. METHODS: We performed a retrospective review on 141 patients revised for ALTR due to head-neck taper corrosion. Pain outcomes following surgery were analyzed using a generalized linear mixed model. Complications were defined as instability/dislocation, infection, fracture, nerve palsy, leg-length discrepancy, or reoperation. RESULTS: The overall complication rate was 17.7%. The odds of having pain decreased by 44% after revision surgery (Odds Ratio = 0.56, 95% Confidence Interval: 0.324 to 0.952). There was no significant difference in instability/dislocation based on either increased or decreased head-neck offset (P = .67) or magnetic resonance imaging findings of abductor loss, effusion size, and degree of ALTR (P = .73). Increased serum cobalt (P = .31) and chromium (P = .08) levels did not predict complications; however, a decreased cobalt-chromium ratio was associated with postoperative complications (2.8 versus 3.5; P = .002). CONCLUSION: These findings are the first to suggest that patients who have ALTR after MoP THA undergoing revision surgery demonstrated major pain relief. Increasing femoral head offset did not change rates of instability/dislocation. In clinical scenarios where preoperative cobalt-chromium femoral head offsets were greater than available ceramic head offsets, a mandatory decrease in femoral head offset did not increase rates of instability/dislocation.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Humanos , Artroplastia de Reemplazo de Cadera/efectos adversos , Reoperación/efectos adversos , Prótesis de Cadera/efectos adversos , Falla de Prótesis , Diseño de Prótesis , Polietileno , Cobalto , Cromo , Corrosión , Metales , Medición de Riesgo , Dolor/etiología
2.
Arthroplast Today ; 13: 125-129, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-35106348

RESUMEN

BACKGROUND: Adverse local tissue reaction (ALTR) is a recognized complication of total hip arthroplasty (THA) with metal-on-polyethylene (MoP) bearing surface implants. Specific models of THA implants have been identified as having a higher incidence of ALTR. The purpose of this study is to determine if serum metal levels, patient symptoms, implant factors, and imaging findings can be predictive of ALTR within this high-risk population. METHODS: We retrospectively reviewed an observational cohort of 474 patients who underwent MoP THA and were at increased risk of having ALTR. Patients were stratified based on the presence or absence of ALTR. Patient symptoms, serum metal ions, implant head offset, and imaging findings were compared. RESULTS: Patients with ALTR were more likely to be symptomatic (52.9% vs 9.9%, P < .0001). The presence of ALTR was associated with significantly higher serum cobalt and chromium levels (6.2 ppb vs 3.6 ppb, P < .0001; 2.3 ppb vs 1.2 ppb, P < .0001). Head offsets greater than 4 mm were associated with a higher prevalence of ALTR (53% vs 38%, P = .05). On metal artifact reduction sequence magnetic resonance imaging, patients with ALTR had larger effusions (4.7 cm vs 2.1 cm, P < .001) and a higher incidence of trochanteric bursitis (47% vs 16%, P < .001). CONCLUSIONS: In high-risk MoP implants, serum cobalt and chromium levels are elevated, even in patients without ALTR. A larger femoral head offset is a risk factor for the development of ALTR. Our study suggests that patients presenting with painful THA and elevated metal ions require risk stratification based on patient symptoms, metal artifact reduction sequence magnetic resonance imaging findings, and implant factors.

3.
J Arthroplasty ; 36(7S): S358-S362, 2021 07.
Artículo en Inglés | MEDLINE | ID: mdl-33036841

RESUMEN

BACKGROUND: Diagnosis of adverse local tissue reaction (ALTR) in metal-on-polyethylene (MoP) total hip arthroplasty (THA) secondary to head-neck taper corrosion is challenging. The purpose of this study is to compare differences between asymptomatic and symptomatic ALTR in an observational cohort, including presentation, metal ion differences, and metal artifact reduction sequence (MARS) magnetic resonance imaging (MRI) findings. METHODS: We performed a retrospective review of an observational cohort of 492 MoP THA patients at increased risk of developing ALTR. Ninety-four patients underwent revision arthroplasty for ALTR. Patients were stratified into symptomatic and asymptomatic ALTR groups. Presentation, metal ion levels, and imaging findings were compared. RESULTS: For patients with confirmed ALTR, 41% were asymptomatic. There was a statistically significant difference in the serum chromium levels between symptomatic and asymptomatic ALTR patients (2.2 µg/L vs 3.1 µg/L, P = .05). There was no statistically significant difference between the serum cobalt levels or MRI findings in these 2 groups. We observed that extracapsular disease associated with ALTR could be misinterpreted as trochanteric bursitis. CONCLUSION: Almost half of the MoP THA ALTR cases identified were asymptomatic. Cobalt levels could not differentiate between symptomatic and asymptomatic pseudotumor formation. Symptomatic and asymptomatic MoP ALTRs have similar MARS MRI characteristics. Our findings suggest that it is essential to risk stratify patients who could potentially have ALTR based on implant type, symptoms, ion levels, and MARS MRI.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Artroplastia de Reemplazo de Cadera/efectos adversos , Cromo , Cobalto/efectos adversos , Corrosión , Prótesis de Cadera/efectos adversos , Humanos , Diseño de Prótesis , Falla de Prótesis , Reoperación , Estudios Retrospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA