1.
Int J Mol Sci ; 24(12)2023 Jun 20.
Artículo en Inglés | MEDLINE | ID: mdl-37373510

RESUMEN

The diagnosis of liquid and solid biopsies by different instruments makes the clinic loading difficult in many aspects. Given the compositions of magnetic particles (MPs) with diverse characterizations and the innovative acoustic type of vibration sample magnetometer (VSM), the versatile, accessible magnetic diagnosis platform was proposed to meet clinical demands, such as low loading for multiple biopsies. In liquid biopsies of alpha-fetoprotein (AFP) standard solutions and subject serums, molecular concentration was analyzed from saturation magnetization by the soft type of Fe3O4 MPs with AFP bioprobe coating. In the phantom mixture simulated as bounded MPs in tissue, the bounded MPs was evaluated from the area of the hysteresis loop by hard type of cobalt MPs without bio-probes coating. Not only a calibration curve was founded for many hepatic cell carcinoma stages, but also microscale images verified the Ms increase due to magnetic protein clusters, etc. Hence, its wide populations in clinics could be expected.


Asunto(s)
Neoplasias Hepáticas , alfa-Fetoproteínas , Humanos , Magnetismo , Neoplasias Hepáticas/diagnóstico , Fenómenos Magnéticos , Biopsia
2.
Sensors (Basel) ; 22(22)2022 Nov 20.
Artículo en Inglés | MEDLINE | ID: mdl-36433573

RESUMEN

The objective of the proposed human-machine cooperation (HMC) workstation is to both rapidly detect calcium-based fish bones in masses of minced fish floss and visually guide operators in approaching and removing the detected fish bones by hand based on the detection of fingernails or plastic-based gloves. Because vibration is a separation mechanism that can prevent absorption or scattering in thick fish floss for UV fluorescence detection, the design of the HMC workstation included a vibration unit together with an optical box and display screens. The system was tested with commonly used fish (swordfish, salmon, tuna, and cod) representing various cooking conditions (raw meat, steam-cooked meat, and fish floss), their bones, and contaminating materials such as derived from gloves made of various types of plastic (polyvinylchloride, emulsion, and rubber) commonly used in the removal of fish bones. These aspects were each investigated using the spectrum analyzer and the optical box to obtain and analyze the fluorescence spectra and images. The filter was mounted on a charge-coupled device, and its transmission-wavelength window was based on the characteristic band for fish bones observed in the spectra. Gray-level AI algorithm was utilized to generate white marker rectangles. The vibration unit supports two mechanisms of air and downstream separation to improve the imaging screening of fish bones inside the considerable flow of fish floss. Notably, under 310 nm ultraviolet B (UVB) excitation, the fluorescence peaks of the raw fillets, steam-cooked meat, and fish floss were observed at for bands at longer wavelengths (500-600 nm), whereas those of the calcium and plastic materials occurred in shorter wavelength bands (400-500 nm). Perfect accuracy of 100% was achieved with the detection of 20 fish bones in 2 kg of fish floss, and the long test time of around 10-12 min results from the manual removal of these fish bones.


Asunto(s)
Calcio , Vibración , Animales , Humanos , Fluorescencia , Vapor , Peces , Tecnología , Plásticos
3.
Micromachines (Basel) ; 13(10)2022 Sep 27.
Artículo en Inglés | MEDLINE | ID: mdl-36295958

RESUMEN

Ablation is a clinical cancer treatment, but some demands are still unsatisfied, such as electromagnetic interferences amongst multiple ablation needles during large tumour treatments. This work proposes a physical synthesis for composite particles of biocompatible iron oxide particles and liquid metal gallium (Ga) with different alternative-current (AC)-magnetic-field-induced heat mechanisms of magnetic particle hyperthermia and superior resistance heat. By some imaging, X-ray diffraction, and vibrating sample magnetometer, utilised composite particles were clearly identified as the cluster of few iron oxides using the small weight ratio of high-viscosity liquid metal Ga as conjugation materials without surfactants for physical targeting of limited fluidity. Hence, well penetration inside the tissue and the promotion rate of heat generation to fit the ablation requirement of at least 60 °C in a few seconds are achieved. For the injection and the post-injection magnetic ablations, the volume variation ratios of mice dorsal tumours on Day 12 were expressed at around one without tumour growth. Its future powerful potentiality is expected through a percutaneous injection.

5.
Biomed Eng Online ; 21(1): 38, 2022 Jun 17.
Artículo en Inglés | MEDLINE | ID: mdl-35715781

RESUMEN

BACKGROUND: Although the powerful clinical effects of radiofrequency and microwave ablation have been established, such ablation is associated with several limitations, including a small ablation size, a long ablation time, the few treatment positioning, and biosafety risks. To overcome these limitations, biosafe and efficient magnetic ablation was achieved in this study by using biocompatible liquid gallium as an ablation medium and a contrast medium for imaging. RESULTS: Magnetic fields with a frequency (f) lower than 200 kHz and an amplitude (H) × f value lower than 5.0 × 109 Am-1 s-1 were generated using the proposed method. These fields could generate an ablation size of 3 cm in rat liver lobes under a temperature of approximately 300 °C and a time of 20 s. The results of this study indicate that biomedical gallium can be used as a contrast medium for the positioning of gallium injections and the evaluation of ablated tissue around a target site. Liquid gallium can be used as an ablation medium and imaging contrast medium because of its stable retention in normal tissue for at least 3 days. Besides, the high anticancer potential of gallium ions was inferred from the self-degradation of 100 µL of liquid gallium after around 21 days of immersion in acidic solutions. CONCLUSIONS: The rapid wireless ablation of large or multiple lesions was achieved through the simple multi-injection of liquid gallium. This approach can replace the currently favoured procedure involving the use of multiple ablation probes, which is associated with limited benefits and several side effects. METHODS: Magnetic ablation was confirmed to be highly efficient by the consistent results obtained in the simulation and in vitro tests of gallium and iron oxide as well as the electromagnetic specifics and thermotherapy performance comparison detailed in this study Ultrasound imaging, X-ray imaging, and magnetic resonance imaging were found to be compatible with the proposed magnetic ablation method. Self-degradation analysis was conducted by mixing liquid gallium in acidic solutions with a pH of approximately 5-7 (to imitate a tumour-containing microenvironment). X-ray diffraction was used to identify the gallium oxides produced by degraded gallium ions.


Asunto(s)
Técnicas de Ablación , Ablación por Catéter , Galio , Animales , Galio/farmacología , Hígado/diagnóstico por imagen , Imagen por Resonancia Magnética , Ratas , Ultrasonografía
6.
Biosensors (Basel) ; 11(10)2021 Sep 30.
Artículo en Inglés | MEDLINE | ID: mdl-34677319

RESUMEN

Infections of orchids by the Odontoglossum ringspot virus or Cymbidium mosaic virus cause orchid disfiguration and are a substantial source of economic loss for orchid farms. Although immunoassays can identify these infections, immunoassays are expensive, time consuming, and labor consuming and limited to sampling-based testing methods. This study proposes a noncontact inspection platform that uses a spectrometer and Android smartphone. When orchid leaves are illuminated with a handheld optical probe, the Android app based on the Internet of Things and artificial intelligence can display the measured florescence spectrum and determine the infection status within 3 s by using an algorithm hosted on a remote server. The algorithm was trained on optical data and the results of polymerase chain reaction assays. The testing accuracy of the algorithm was 89%. The area under the receiver operating characteristic curve was 91%; thus, the platform with the algorithm was accurate and convenient for infection screening in orchids.


Asunto(s)
Orchidaceae , Teléfono Inteligente , Inteligencia Artificial , Enfermedades de las Plantas/virología , Reacción en Cadena de la Polimerasa , Potexvirus , Tobamovirus
7.
Sensors (Basel) ; 18(4)2018 Mar 30.
Artículo en Inglés | MEDLINE | ID: mdl-29601532

RESUMEN

An alternating-current magnetosusceptometer of antibody-functionalized magnetic nanoparticles (MNPs) was developed for immunomagnetic reduction (IMR). A high-sensitivity, high-critical-temperature superconducting quantum interference device was used in the magnetosusceptometer. Minute levels of biomarkers of early-stage neurodegeneration diseases were detectable in serum, but measuring each biomarker required approximately 4 h. Hence, an eight-channel platform was developed in this study to fit minimal screening requirements for Alzheimer's disease. Two consistent results were measured for three biomarkers, namely Aß40, Aß42, and tau protein, per human specimen. This paper presents the instrument configuration as well as critical characteristics, such as the low noise level variations among channels, a high signal-to-noise ratio, and the coefficient of variation for the biomarkers' IMR values. The instrument's ultrahigh sensitivity levels for the three biomarkers and the substantially shorter total measurement time in comparison with the previous single- and four-channels platforms were also demonstrated in this study. Thus, the eight-channel instrument may serve as a powerful tool for clinical high-throughput screening of Alzheimer's disease.


Asunto(s)
Nanopartículas de Magnetita , Enfermedad de Alzheimer , Péptidos beta-Amiloides , Biomarcadores , Humanos , Inmunoensayo , Magnetismo , Proteínas tau
8.
ACS Nano ; 11(3): 3030-3037, 2017 03 28.
Artículo en Inglés | MEDLINE | ID: mdl-28276684

RESUMEN

Biofunctional magnetic nanoparticles (MNPs) have been widely applied in biomedical engineering. MNPs are used as a contrast medium in magnetic imaging. Current methods of magnetic imaging, such as magnetic particle imaging and magnetic relaxometry, use small amounts of MNPs at target points far from the surface of the patient's body; these methods always consume considerable power to produce magnetic fields of high uniformity or gradient excitations. Some drawbacks, such as a limited imaging region, imaging system shielding, and complex algorithms based on assumptions of MNP properties or environmental factors, also limit the application of MNP methods in clinics. Therefore, this work proposes an interdisciplinary methodology of ultrasound-induced magnetic imaging that lacks these drawbacks. In the proposed imaging method, magnet sets were designed with uniform magnetic fields to magnetize MNPs. Besides, magnetized MNPs are subjected to ultrasound vibrations; the motion of the MNPs induces weak induction voltages at the imaging pickup coils. The highly sensitive scanning superconducting quantum interference device biosusceptometry with three sets of ultrasound focus chips was developed to construct magnetic tomography at three depths. A phantom test showed favorable consistency between the visual photos and the magnetic images of alpha-fetoprotein antibody (anti-AFP) MNP distribution on gauzes. In animal tests, rats with liver tumors were imaged at the pre-injection and post-injection of anti-AFP MNPs. The consistent results of magnetic images and ultrasound images implied that the proposed method has high clinical potential.


Asunto(s)
Neoplasias Hepáticas/diagnóstico , Campos Magnéticos , Nanopartículas de Magnetita/química , Ultrasonografía , alfa-Fetoproteínas/química , Animales , Magnetismo , Ratas
9.
Nanotechnology ; 27(23): 235101, 2016 Jun 10.
Artículo en Inglés | MEDLINE | ID: mdl-27138705

RESUMEN

After a needle biopsy, immunohistochemistry is generally used to stain tissue slices for clinically confirming tumours. Currently, tissue slices are immersed in a bioprobe-linked fluorescent reagent for several minutes, washed to remove the unbound reagent, and then observed using a fluorescence microscope. However, the observation must be performed by experienced pathologists, and producing a qualitative analysis is time consuming. Therefore, this study proposes a novel scanning superconducting quantum interference device biosusceptometry (SSB) method for avoiding these drawbacks. First, stain reagents were synthesised for the dual modalities of fluorescent and magnetic imaging by combining iron-oxide magnetic nanoparticles and the currently used fluorescent reagent. The reagent for the proposed approach was stained using the same procedure as that for the current fluorescent reagent, and tissue slices were rapidly imaged using the developed SSB for obtaining coregistered optical and magnetic images. Analysing the total intensity of magnetic spots in SSB images enables quantitatively determining the tumour cells of tissue slices. To confirm the magnetic imaging results, a traditional observation methodology entailing the use of a fluorescence microscope was also performed as the gold standard. This study determined high consistency between the fluorescent and magnetic spots in different regions of the tissue slices, demonstrating the feasibility of the proposed approach, which will benefit future clinical pathology.


Asunto(s)
Neoplasias , Humanos , Magnetismo , Microscopía Fluorescente , Nanopartículas
10.
J Nanobiotechnology ; 13: 11, 2015 Feb 12.
Artículo en Inglés | MEDLINE | ID: mdl-25889863

RESUMEN

BACKGROUND: For intraoperative imaging in operating theaters or preoperative imaging in clinics, compact and economic integration rather than large and expensive equipment is required to coregister structural and functional imaging. However, current technologies, such as those integrating optical and gamma cameras or infrared and fluorescence imaging, involve certain drawbacks, including the radioactive biorisks of nuclear medicine indicators and the inconvenience of conducting measurements in dark environments. METHODS: To specifically and magnetically label liver tumors, an anti-alpha-fetoprotein (AFP) reagent was synthesized from biosafe iron oxide magnetic nanoparticles (MNPs) coated with anti-AFP antibody and solved in a phosphate buffered saline solution. In addition, a novel dual-imaging model system integrating an optical camera and magnetic scanning superconducting-quantum-interference device (SQUID) biosusceptometry (SSB) was proposed. The simultaneous coregistration of low-field magnetic images of MNP distributions and optical images of anatomical regions enabled the tumor distribution to be determined easily and in real time. To simulate targeted MNPs within animals, fewer reagents than the injected dose were contained in a microtube as a sample for the phantom test. The phantom test was conducted to examine the system characteristics and the analysis method of dual images. Furthermore, the animal tests were classified into two types, with liver tumors implanted either on the backs or livers of rats. The tumors on the backs were to visually confirm the imaging results of the phantom test, and the tumors on the livers were to simulate real cases in hepatocellular carcinoma people. RESULTS: A phantom test was conducted using the proposed analysis method; favorable contour agreement was shown between the MNP distribution in optical and magnetic images. Consequently, the positioning and discrimination of liver tumors implanted on the backs and livers of rats were verified by conducting in vivo and ex vivo tests. The results of tissue staining verified the feasibility of using this method to determine the distribution of liver tumors. CONCLUSION: The results of this study indicate the clinical potential of using anti-AFP-mediated MNPs and the dual-imaging model SSB for discriminating and locating tumors.


Asunto(s)
Neoplasias Hepáticas Experimentales/diagnóstico , Nanopartículas de Magnetita , Magnetometría/métodos , Animales , Diseño de Equipo , Procesamiento de Imagen Asistido por Computador/métodos , Cuidados Intraoperatorios , Neoplasias Hepáticas Experimentales/patología , Magnetometría/instrumentación , Masculino , Fantasmas de Imagen , Cuidados Preoperatorios , Ratas , Ratas Endogámicas F344 , Grabación en Video/instrumentación , alfa-Fetoproteínas/química
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...