Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
PLoS One ; 10(8): e0134980, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-26244982

RESUMEN

Fluorescence confocal microscopy represents one of the central tools in modern sciences. Correspondingly, a growing amount of research relies on the development of novel microscopic methods. During the last decade numerous microscopic approaches were developed for the investigation of various scientific questions. Thereby, the former qualitative imaging methods became replaced by advanced quantitative methods to gain more and more information from a given sample. However, modern microscope systems being as complex as they are, require very precise and appropriate calibration routines, in particular when quantitative measurements should be compared over longer time scales or between different setups. Multispectral beads with sub-resolution size are often used to describe the point spread function and thus the optical properties of the microscope. More recently, a fluorescent layer was utilized to describe the axial profile for each pixel, which allows a spatially resolved characterization. However, fabrication of a thin fluorescent layer with matching refractive index is technically not solved yet. Therefore, we propose a novel type of calibration concept for sectioned image property (SIP) measurements which is based on fluorescent solution and makes the calibration concept available for a broader number of users. Compared to the previous approach, additional information can be obtained by application of this extended SIP chart approach, including penetration depth, detected number of photons, and illumination profile shape. Furthermore, due to the fit of the complete profile, our method is less susceptible to noise. Generally, the extended SIP approach represents a simple and highly reproducible method, allowing setup independent calibration and alignment procedures, which is mandatory for advanced quantitative microscopy.


Asunto(s)
Algoritmos , Fluorescencia , Microscopía Confocal/métodos , Microscopía Fluorescente/métodos , Calibración/normas , Interpretación de Imagen Asistida por Computador/métodos , Interpretación de Imagen Asistida por Computador/normas , Mediciones Luminiscentes/métodos , Mediciones Luminiscentes/normas , Microscopía Confocal/normas , Microscopía Fluorescente/normas , Reproducibilidad de los Resultados
2.
PLoS One ; 7(7): e41688, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-22844515

RESUMEN

Expression of activity-regulated cytoskeleton associated protein (Arc) is crucial for diverse types of experience-dependent synaptic plasticity and long-term memory in mammals. However, the mechanisms governing Arc-specific translation are little understood. Here, we asked whether Arc translation is regulated by microRNAs. Bioinformatic analysis predicted numerous candidate miRNA binding sites within the Arc 3'-untranslated region (UTR). Transfection of the corresponding microRNAs in human embryonic kidney cells inhibited expression of an Arc 3'UTR luciferase reporter from between 10 to 70% across 16 microRNAs tested. Point mutation and deletion of the microRNA-binding seed-region for miR-34a, miR-326, and miR-19a partially or fully rescued reporter expression. In addition, expression of specific microRNA pairs synergistically modulated Arc reporter expression. In primary rat hippocampal neuronal cultures, ectopic expression of miR-34a, miR-193a, or miR-326, downregulated endogenous Arc protein expression in response to BDNF treatment. Conversely, treatment of neurons with cell-penetrating, peptide nucleic acid (PNA) inhibitors of miR-326 enhanced Arc mRNA expression. BDNF dramatically upregulated neuronal expression of Arc mRNA and miR-132, a known BDNF-induced miRNA, without affecting expression of Arc-targeting miRNAs. Developmentally, miR-132 was upregulated at day 10 in vitro whereas Arc-targeting miRNAs were downregulated. In the adult brain, LTP induction in the dentate gyrus triggered massive upregulation of Arc and upregulation of miR-132 without affecting levels of mature Arc-targeting miRNAs. Turning to examine miRNA localization, qPCR analysis of dentate gyrus synaptoneurosome and total lysates fractions demonstrated synaptic enrichment relative to small nucleolar RNA. In conclusion, we find that Arc is regulated by multiple miRNAs and modulated by specific miRNA pairs in vitro. Furthermore, we show that, in contrast to miR-132, steady state levels of Arc-targeting miRNAs do not change in response to activity-dependent expression of Arc in hippocampal neurons in vitro or during LTP in vivo.


Asunto(s)
Proteínas del Citoesqueleto/genética , MicroARNs/genética , MicroARNs/metabolismo , Proteínas del Tejido Nervioso/genética , Plasticidad Neuronal/genética , Sinapsis/metabolismo , Regiones no Traducidas 3'/genética , Animales , Secuencia de Bases , Factor Neurotrófico Derivado del Encéfalo/metabolismo , Proteínas del Citoesqueleto/metabolismo , Dendritas/metabolismo , Células HEK293 , Hipocampo/citología , Hipocampo/fisiología , Humanos , Espacio Intracelular/metabolismo , Potenciación a Largo Plazo/genética , Masculino , Proteínas del Tejido Nervioso/metabolismo , Neuronas/citología , Neuronas/metabolismo , Oligonucleótidos Antisentido/genética , Mutación Puntual , Transporte de Proteínas , Ratas , Ratas Sprague-Dawley , Eliminación de Secuencia , Transcriptoma , Regulación hacia Arriba/genética
3.
Knee Surg Sports Traumatol Arthrosc ; 18(5): 673-80, 2010 May.
Artículo en Inglés | MEDLINE | ID: mdl-19838673

RESUMEN

The purpose of this study was to analyze the impact of monopolar radiofrequency energy treatment on subchondral bone viability. The femoral grooves of six chinchilla bastard rabbits were exposed bilaterally to monopolar radiofrequency energy for 2, 4 and 8 s, creating a total of 36 defects. An intravital fluorescence bone-labeling technique characterized the process of subchondral bone mineralization within the 3 months following exposure to radiofrequency energy and was analyzed by widefield epifluorescence optical sectioning microscopy using an ApoTome. After 2 s of radiofrequency energy exposure, regular fluorescence staining of the subchondral bone was evident in all samples when compared to untreated areas. The depth of osteonecrosis after 4 and 8 s of radiofrequency energy treatment averaged 126 and 942 microm at 22 days (P < .05; P < .01). The 4 s treatment group showed no osteonecrosis after 44 days whereas the depth of osteonecrosis extended from 519 microm at 44 days (P < .01), to 281 microm at 66 days (P < .01) and to 133 microm at 88 days (P < .05) after 8 s of radiofrequency energy application. Though radiofrequency energy may induce transient osteonecrosis in the superficial zone of the subchondral bone, the results of this study suggest that post-arthroscopic osteonecrosis appears to be of only modest risk given the current clinical application in humans.


Asunto(s)
Regeneración Ósea/efectos de la radiación , Diatermia/efectos adversos , Fémur/cirugía , Ondas de Radio/efectos adversos , Animales , Femenino , Conejos , Traumatismos Experimentales por Radiación
4.
J Biomed Opt ; 14(1): 014022, 2009.
Artículo en Inglés | MEDLINE | ID: mdl-19256710

RESUMEN

The essential feature of the confocal laser scanning microscope (cLSM) is the generation of optical sections by the removal of out-of-focus light. About ten years ago, structured illumination microscopy (SIM) was introduced as an alternative method for obtaining optical sections from biological specimens. Here we compare the resolution of the ApoTome (commercial SIM by Zeiss) to that achieved by a cLSM (Zeiss LSM 510). If fluorescent beads are used as test objects, then the ApoTome will achieve a lower axial resolution than the cLSM. In contrast to that, its lateral resolution scores slightly better. If subresolution homogeneous fluorescent layers are used as test objects, then the ApoTome will achieve a higher axial resolution than the cLSM. The ApoTome's axial resolution is homogeneous over the field-of-view while that of the cLSM changes markedly. Finally, the anisotropy of the ApoTome's resolution was found to be negligible for standard applications while its capability to resolve fine structures within stained tissue slices is limited to one or two cell layers and thus worse than in the cLSM.


Asunto(s)
Anatomía Transversal/instrumentación , Microscopía Confocal/instrumentación , Microscopía Fluorescente/instrumentación , Diseño de Equipo , Análisis de Falla de Equipo , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA