Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 85
Filtrar
2.
Eur Radiol ; 2024 Apr 16.
Artículo en Inglés | MEDLINE | ID: mdl-38625611

RESUMEN

Stable chest pain is a common symptom with multiple potential causes. Non-invasive imaging has an important role in diagnosis and guiding management through the assessment of coronary stenoses, atherosclerotic plaque, myocardial ischaemia or infarction, and cardiac function. Computed tomography (CT) provides the anatomical evaluation of coronary artery disease (CAD) with the assessment of stenosis, plaque type and plaque burden, with additional functional information available from CT fractional flow reserve (FFR) or CT myocardial perfusion imaging. Stress magnetic resonance imaging, nuclear stress myocardial perfusion imaging, and stress echocardiography can assess myocardial ischaemia and other cardiac functional parameters. Coronary CT angiography can be used as a first-line test for many patients with stable chest pain, particularly those with low to intermediate pre-test probability. Functional testing may be considered for patients with known CAD, where the clinical significance is uncertain based on anatomical testing, or in patients with high pre-test probability. This practice recommendations document can be used to guide the selection of non-invasive imaging for patients with stable chest pain and provides brief recommendations on how to perform and report these diagnostic tests. KEY POINTS: The selection of non-invasive imaging tests for patients with stable chest pain should be based on symptoms, pre-test probability, and previous history. Coronary CT angiography can be used as a first-line test for many patients with stable chest pain, particularly those with low to intermediate pre-test probability. Functional testing can be considered for patients with known CAD, where the clinical significance of CAD is uncertain based on anatomical testing, or in patients with high pre-test probability. KEY RECOMMENDATIONS: Non-invasive imaging is an important part of the assessment of patients with stable chest pain. The selection of non-invasive imaging test should be based on symptoms, pre-test probability, and previous history. (Level of evidence: High). Coronary CT angiography can be used as a first line test for many patients with stable chest pain, particularly those with low to intermediate pre-test probability. CT provides information on stenoses, plaque type, plaque volume, and if required functional information with CT fractional flow reserve or CT perfusion. (Level of evidence: High). Functional testing can be considered for patients with known CAD, where the clinical significance of CAD is uncertain based on anatomical testing, or in patients with high pre-test probability. Stress MRI, SPECT, PET, and echocardiography can provide information on myocardial ischemia, along with cardiac functional and other information. (Level of evidence: Medium).

3.
Radiol Clin North Am ; 62(3): 419-434, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38553178

RESUMEN

The range of potential transcatheter solutions to valve disease is increasing, bringing treatment options to those in whom surgery confers prohibitively high risk. As the range of devices and their indications grow, so too will the demand for procedural planning. Computed tomography will continue to enable this growth through the provision of accurate device sizing and procedural risk assessment.


Asunto(s)
Válvula Aórtica , Tomografía Computarizada por Rayos X , Humanos , Válvula Aórtica/cirugía , Tomografía Computarizada por Rayos X/métodos , Medición de Riesgo , Resultado del Tratamiento , Tomografía Computarizada Multidetector/métodos
5.
J Am Soc Echocardiogr ; 37(1): 2-63, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38182282

RESUMEN

In patients with significant cardiac valvular disease, intervention with either valve repair or valve replacement may be inevitable. Although valve repair is frequently performed, especially for mitral and tricuspid regurgitation, valve replacement remains common, particularly in adults. Diagnostic methods are often needed to assess the function of the prosthesis. Echocardiography is the first-line method for noninvasive evaluation of prosthetic valve function. The transthoracic approach is complemented with two-dimensional and three-dimensional transesophageal echocardiography for further refinement of valve morphology and function when needed. More recently, advances in computed tomography and cardiac magnetic resonance have enhanced their roles in evaluating valvular heart disease. This document offers a review of the echocardiographic techniques used and provides recommendations and general guidelines for evaluation of prosthetic valve function on the basis of the scientific literature and consensus of a panel of experts. This guideline discusses the role of advanced imaging with transesophageal echocardiography, cardiac computed tomography, and cardiac magnetic resonance in evaluating prosthetic valve structure, function, and regurgitation. It replaces the 2009 American Society of Echocardiography guideline on prosthetic valves and complements the 2019 guideline on the evaluation of valvular regurgitation after percutaneous valve repair or replacement.


Asunto(s)
Enfermedades de las Válvulas Cardíacas , Corazón , Adulto , Humanos , Imagen por Resonancia Magnética , Ecocardiografía , Prótesis e Implantes , Enfermedades de las Válvulas Cardíacas/diagnóstico , Enfermedades de las Válvulas Cardíacas/cirugía , Espectroscopía de Resonancia Magnética
6.
J Biomech ; 161: 111857, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37939424

RESUMEN

For image-based computational fluid dynamics (CFD) analysis to characterize the local coronary hemodynamic environment, the accuracy depends on the flow rate which is in turn associated with outlet branches' morphology. A good flow distribution strategy is important to mitigate the effect when certain branches cannot be considered. In this study, stenotic coronary arteries from 13 patients were used to analyze the effect of missing branches and different flow distribution strategies. Pressure- and wall shear stress (WSS)-derived parameters around the stenotic region (ROI) were compared, including fractional flow reserve (CT-FFR), instantaneous wave-free ratio (CT-iFR), resting distal to aortic coronary pressure (CT-Pd/Pa), time-averaged WSS, oscillatory shear index (OSI) and relative residence time (RRT). Three flow distribution strategies were the Huo-Kassab model at distal outlets (Type I), flow distribution based on outlet resistances (Type II), and a developed algorithm distributing flow at each bifurcation until the final outlets (Type III). Results showed that Type III strategy for models with truncated branch(es) had a good agreement in both pressure- and WSS-related results (interquatile range less than 0.12% and 4.02%, respectively) with the baseline model around the ROI. The relative difference of pressure- and WSS-related results were correlated with the flow differences in the ROI to the baseline mode. Type III strategy had the best performance in maintaining the flow in intermediate branches. It is recommended for CFD analysis. Removal of branches distal to a stenosis can be undertaken with an improved performance and maintained accuracy, while those proximal to the ROI should be kept.


Asunto(s)
Estenosis Coronaria , Reserva del Flujo Fraccional Miocárdico , Humanos , Vasos Coronarios , Estenosis Coronaria/diagnóstico por imagen , Hidrodinámica , Corazón , Hemodinámica , Angiografía Coronaria
7.
Radiology ; 308(2): e221963, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37526539

RESUMEN

Background In the Scottish Computed Tomography of the Heart (SCOT-HEART) trial in individuals with stable chest pain, a treatment strategy based on coronary CT angiography (CTA) led to improved outcomes. Purpose To assess 5-year cumulative radiation doses of participants undergoing investigation for suspected angina due to coronary artery disease with or without coronary CTA. Materials and Methods This secondary analysis of the SCOT-HEART trial included data from six of 12 recruiting sites and two of three imaging sites. Participants were recruited between November 18, 2010, and September 24, 2014, with follow-up through January 31, 2018. Study participants had been randomized (at a one-to-one ratio) to standard care with CT (n = 1466) or standard care alone (n = 1428). Imaging was performed on a 64-detector (n = 223) or 320-detector row scanner (n = 1466). Radiation dose from CT (dose-length product), SPECT (injected activity), and invasive coronary angiography (ICA; kerma-area product) was assessed for 5 years after enrollment. Effective dose was calculated using conversion factors appropriate for the imaging modality and body region imaged (using 0.026 mSv/mGy · cm for cardiac CT). Results Cumulative radiation dose was assessed in 2894 participants. Median effective dose was 3.0 mSv (IQR, 2.6-3.3 mSv) for coronary calcium scoring, 4.1 mSv (IQR, 2.6-6.1 mSv) for coronary CTA, 7.4 mSv (IQR, 6.2-8.5 mSv) for SPECT, and 4.1 mSv (IQR, 2.5-6.8 mSv) for ICA. After 5 years, total per-participant cumulative dose was higher in the CT group (median, 8.1 mSv; IQR, 5.5-12.4 mSv) compared with standard-care group (median, 0 mSv; IQR, 0-4.5 mSv; P < .001). In participants who underwent any imaging, cumulative radiation exposure was higher in the CT group (n = 1345; median, 8.6 mSv; IQR, 6.1-13.3 mSv) compared with standard-care group (n = 549; median, 6.4 mSv; IQR, 3.4-9.2 mSv; P < .001). Conclusion In the SCOT-HEART trial, the 5-year cumulative radiation dose from cardiac imaging was higher in the coronary CT angiography group compared with the standard-care group, largely because of the radiation exposure from CT. Clinical trial registration no. NCT01149590 © RSNA, 2023 Supplemental material is available for this article. See also the editorial by Dodd and Bosserdt in this issue.


Asunto(s)
Enfermedad de la Arteria Coronaria , Exposición a la Radiación , Humanos , Dolor en el Pecho/diagnóstico por imagen , Dolor en el Pecho/etiología , Angiografía por Tomografía Computarizada , Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/complicaciones , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Dosis de Radiación , Tomografía Computarizada por Rayos X
8.
11.
Sci Data ; 10(1): 493, 2023 07 27.
Artículo en Inglés | MEDLINE | ID: mdl-37500661

RESUMEN

The National COVID-19 Chest Imaging Database (NCCID) is a centralized UK database of thoracic imaging and corresponding clinical data. It is made available by the National Health Service Artificial Intelligence (NHS AI) Lab to support the development of machine learning tools focused on Coronavirus Disease 2019 (COVID-19). A bespoke cleaning pipeline for NCCID, developed by the NHSx, was introduced in 2021. We present an extension to the original cleaning pipeline for the clinical data of the database. It has been adjusted to correct additional systematic inconsistencies in the raw data such as patient sex, oxygen levels and date values. The most important changes will be discussed in this paper, whilst the code and further explanations are made publicly available on GitLab. The suggested cleaning will allow global users to work with more consistent data for the development of machine learning tools without being an expert. In addition, it highlights some of the challenges when working with clinical multi-center data and includes recommendations for similar future initiatives.


Asunto(s)
COVID-19 , Tórax , Humanos , Inteligencia Artificial , Aprendizaje Automático , Medicina Estatal , Radiografía Torácica , Tórax/diagnóstico por imagen
12.
J Cardiovasc Comput Tomogr ; 17(6): 459-464, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37429770

RESUMEN

The Society of Cardiovascular Computed Tomography (SCCT) is an international community of physicians, scientists and technologists advocating for research, education, and clinical excellence in the use of cardiovascular computed tomography (CCT). SCCT members are committed to improving health outcomes through effective use of CCT. The SCCT routinely authors, endorses, and jointly collaborates on scientific documents that reflect the best available evidence and expert consensus supported in practice of CCT. This paper outlines SCCT's methodology for developing scientific documents. It was formulated by members of the SCCT Guidelines Committee and approved by the SCCT Board of Directors.


Asunto(s)
Sistema Cardiovascular , Tomografía Computarizada por Rayos X , Humanos , Valor Predictivo de las Pruebas , Sociedades Científicas , Consenso
13.
Pulm Circ ; 13(3): e12265, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-37415805

RESUMEN

Pulmonary endarterectomy (PEA) may not achieve full clearance of vascular obstructions in patients with more distal chronic thromboembolic pulmonary hypertension (CTEPH). Balloon pulmonary angioplasty (BPA) may be indicated to treat these residual vascular lesions. We compared whether patients post-PEA (PP) treated by BPA derived similar benefit to those who had inoperable CTEPH (IC), and assessed predictors of BPA response after surgery. We treated 109 patients with BPA-89 with IC and 20 PP. Serial right heart catheterization performed at baseline (immediately before BPA) and 3 months after completing BPA, compared pulmonary vascular resistance (PVR), mean pulmonary artery pressure (mPAP) as well as change in WHO functional class and 6-minute walk distance. We also assessed the impact of total thrombus tail length (TTTL) from photographed PEA surgical specimens and PP computed tomography pulmonary angiography (CTPA)-quantified residual disease burden on BPA response. PP and IC groups did not differ significantly in terms of demographics, baseline hemodynamics or procedural characteristics. However, IC derived greater hemodynamic benefit from BPA: ΔPVR (-27.9 ± 20.2% vs. -13.9 ± 23.9%, p < 0.05) and ΔmPAP (-17.1 ± 14.4% vs. -8.5 ± 18.0%, p < 0.05). There was a negative correlation between pre-BPA PVR and TTTL (r = -0.47, p < 0.05) which persisted post-BPA. PVR, mPAP, WHO FC and 6MWD were not improved significantly post-BPA in PP patients. BPA response was not related to TTTL terciles or CTPA-quantified residual disease burden. Patients PP experienced inferior response to BPA, despite similar baseline and procedural characteristics to IC. BPA does not abolish the relationship between TTTL and postsurgical PVR in PP patients, suggesting that BPA is less effective in treating residual PH after surgery in an experienced surgical center.

16.
J Cardiovasc Comput Tomogr ; 17(3): 226-230, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37015851

RESUMEN

BACKGROUND: As cardiovascular computed tomography (CCT) practice evolves, the demand for specialists continues to increase. However, CCT training remains variable globally with limited contemporaneous data to understand this heterogeneity. We sought to understand the role of CCT globally and the training available to underpin its use. METHODS: We performed two consecutive surveys of cardiology and radiology physicians, two years apart, utilizing the Society of Cardiovascular Computed Tomography (SCCT) website, weblinks, social media platforms, and meeting handouts to maximize our response rate. We compared United States (US)-based vs. international responses to understand global similarities and differences in practice and training in the surveys. RESULTS: 235 respondents (37% trainees and 63% educators/non-trainees) initiated the first survey with 174 (74%) completing the core survey, with 205 providing their work location (114 US and 91 international). Eighty-four percent (92/110) of educator respondents stated a need for increased training opportunities to meet growing demand. Dedicated training fellowships are heterogenous, with limited access to structural heart imaging training, despite structural scanning being performed within institutions. The lack of a standardized curriculum was identified as the main obstacle to effective CCT learning, particularly in the US, with web-based learning platforms being the most popular option for improving access to CCT training. 148 trainees initiated the second survey with 107 (72%) completing the core components (51% North America, 49% international). Only 68% said they would be able to meet their required CCT education needs via their training program. Obstacles in obtaining CCT training again included a lack of a developed curriculum (51%), a lack of dedicated training time (35%), and a lack of local faculty expertise (31%). There was regional variability in access to CCT training, and, in contrast to the first survey, most (89%) felt 1:1 live review of cases with trained/expert reader was most useful for improving CCT training alongside formal curriculum/live lectures (72%). CONCLUSIONS: There is a need to expand dedicated CCT training globally to meet the demand for complex CCT practice. Access to CCT education (didactic and 1:1 case-based teaching from expert faculty), implementation of recently published global training curricula, and increased teaching resources (web-based) as an adjunct to existing experiential learning opportunities, are all deemed necessary to address current educational shortfalls.


Asunto(s)
Cardiología , Curriculum , Humanos , Estados Unidos , Valor Predictivo de las Pruebas , Encuestas y Cuestionarios , Tomografía Computarizada por Rayos X
17.
JACC Cardiovasc Imaging ; 16(5): 659-671, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-36752441

RESUMEN

BACKGROUND: In 2016, the National Institute for Health and Care Excellence Clinical Guideline Number 95 ("Chest pain of recent onset") (CG95) recommended coronary computed tomography angiography (CCTA) as the first-line test for possible angina. OBJECTIVES: The purpose of this study was to determine the impact of temporal trends in imaging use on outcomes for coronary artery disease (CAD) following the CG95 recommendations. METHODS: Investigations from 2012 to 2018 were extracted from a national database and linked to hospital admission and mortality registries. Growth rates were adjusted for population size, with image modality use, cardiovascular hospital admissions, and mortality compared using Kendall's rank correlation. The impact of CG95 was assessed using an interrupted time-series analysis. RESULTS: A total of 1,909,314 investigations for CAD were performed, with an annualized per capita growth of 4.8%. Costs were £0.35 million/100,000 population/year with an increase of 2.8%/year mirroring inflation (2.5%/year). CG95 was associated with a rise in CCTA (exp[ß]: 1.10; 95% CI: 1.03-1.18), no change in myocardial perfusion imaging, and a potential modest fall (exp[ß]: 0.997; 95% CI: 0.993-1.00]) in invasive coronary angiography. There was an apparent trend between computed tomography angiography growth and invasive catheter angiography reduction across regions (Kendall Tau: -0.19; P = 0.08). CCTA growth was associated with a reduction in cardiovascular mortality (Kendall Tau: -0.21; P = 0.045), and ischemic heart disease deaths (Kendall Tau: -0.22; P = 0.042), with an apparent trend with reduced all-cause mortality (Kendall Tau: -0.19; P = 0.07). CONCLUSIONS: Imaging investigations for CAD are increasing. Greater regional increases in CCTA were associated with fewer hospitalizations for myocardial infarction and a more rapid decline in CAD mortality.


Asunto(s)
Enfermedad de la Arteria Coronaria , Humanos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/terapia , Enfermedad de la Arteria Coronaria/complicaciones , Valor Predictivo de las Pruebas , Angina de Pecho , Angiografía Coronaria/métodos , Angiografía por Tomografía Computarizada , Atención a la Salud
18.
J Card Fail ; 29(5): 834-840, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-36521726

RESUMEN

BACKGROUND: Heart transplantation (HTx) after donation after circulatory death (DCD) is an expanding practice but is associated with increased warm ischemic time. The impact of DCD HTx on cardiac mechanics and myocardial fibrosis has not been reported. We aimed to compare cardiac mechanics and myocardial fibrosis using cardiovascular magnetic resonance (CMR) imaging in donation after brain death (DBD) and DCD HTx recipients and healthy controls. METHODS AND RESULTS: Consecutive HTx recipients between March 2015 and March 2021 who underwent routine surveillance CMR imaging were included. Cardiac mechanics were assessed using CMR feature tracking to compute global longitudinal strain, global circumferential strain, and right ventricular free-wall longitudinal myocardial strain. Fibrosis was assessed using late gadolinium enhancement imaging and estimation of extracellular volume. There were 82 (DBD n = 42, DCD n = 40) HTx recipients (aged 53 years, interquartile range 41-59 years, 24% female) who underwent CMR imaging at median of 9 months (interquartile range 6-14 months) after transplantation. HTx recipients had increased extracellular volume (29.7 ± 3.6%) compared with normal ranges (25.9%, interquartile range 25.4-26.5). Myocardial strain was impaired after transplantation compared with controls (global longitudinal strain -12.6 ± 3.1% vs -17.2 ± 1.8%, P < .0001; global circumferential strain -16.9 ± 3.1% vs -19.2 ± 2.0%, P = .002; right ventricular free-wall longitudinal strain -15.7 ± 4.5% vs -21.6 ± 4.7%, P < .0001). There were no differences in fibrosis burden (extracellular volume 30.6 ± 4.4% vs 29.2 ± 3.2%; P = .39) or cardiac mechanics (global longitudinal strain -13.1 ± 3.0% vs -12.1 ± 3.1%, P = .14; global circumferential strain -17.3 ± 2.9% vs -16.6 ± 3.1%, P = .27; right ventricular free-wall longitudinal strain -15.9 ± 4.9% vs -15.5 ± 4.1%, P = .71) between DCD and DBD HTx. CONCLUSIONS: HTx recipients have impaired cardiac mechanics compared with controls, with increased myocardial fibrosis. There were no differences in early CMR imaging characteristics between DBD and DCD heart transplants, providing further evidence that DCD and DBD HTx outcomes are comparable.


Asunto(s)
Cardiomiopatías , Insuficiencia Cardíaca , Trasplante de Corazón , Humanos , Femenino , Masculino , Medios de Contraste , Gadolinio , Insuficiencia Cardíaca/diagnóstico por imagen , Insuficiencia Cardíaca/cirugía , Trasplante de Corazón/efectos adversos , Fibrosis , Estudios Retrospectivos , Donantes de Tejidos
19.
Chest ; 163(2): 444-454, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36087795

RESUMEN

BACKGROUND: Solitary pulmonary nodules (SPNs) measuring 8 to 30 mm in diameter require further workup to determine the likelihood of malignancy. RESEARCH QUESTION: What is the diagnostic performance of a lung cancer prediction convolutional neural network (LCP-CNN) in SPNs using unenhanced and contrast-enhanced CT imaging compared with the current clinical workup? STUDY DESIGN AND METHODS: This was a post hoc analysis of the Single Pulmonary Nodule Investigation: Accuracy and Cost-Effectiveness of Dynamic Contrast Enhanced Computed Tomography in the Characterisation of Solitary Pulmonary Nodules trial, a prospective multicenter study comparing the diagnostic accuracy of dynamic contrast-enhanced (DCE) CT imaging with PET imaging in SPNs. The LCP-CNN was designed and validated in an external cohort. LCP-CNN-generated risk scores were created from the noncontrast and contrast-enhanced CT scan images from the DCE CT imaging. The gold standard was histologic analysis or 2 years of follow-up. The area under the receiver operating characteristic curves (AUC) were calculated using LCP-CNN score, maximum standardized uptake value, and DCE CT scan maximum enhancement and were compared using the DeLong test. RESULTS: Two hundred seventy participants (mean ± SD age, 68.3 ± 8.8 years; 49% women) underwent PET with CT scan imaging and DCE CT imaging with CT scan data available centrally for LCP-CNN analysis. The accuracy of the LCP-CNN on the noncontrast images (AUC, 0.83; 95% CI, 0.79-0.88) was superior to that of DCE CT imaging (AUC, 0.76; 95% CI, 0.69-0.82; P = .03) and equal to that of PET with CT scan imaging (AUC, 0.86; 95% CI, 0.81-0.90; P = .35). The presence of contrast resulted in a small reduction in diagnostic accuracy, with the AUC falling from 0.83 (95% CI, 0.79-0.88) on the noncontrast images to 0.80 to 0.83 after contrast (P < .05 for 240 s after contrast only). INTERPRETATION: An LCP-CNN algorithm provides an AUC equivalent to PET with CT scan imaging in the diagnosis of solitary pulmonary nodules. TRIAL REGISTRATION: ClinicalTrials.gov Identifier; No.: NCT02013063.


Asunto(s)
Neoplasias Pulmonares , Nódulo Pulmonar Solitario , Humanos , Femenino , Persona de Mediana Edad , Anciano , Masculino , Nódulo Pulmonar Solitario/patología , Estudios Prospectivos , Radiofármacos , Fluorodesoxiglucosa F18 , Tomografía Computarizada por Rayos X/métodos , Neoplasias Pulmonares/diagnóstico , Tomografía de Emisión de Positrones , Redes Neurales de la Computación , Sensibilidad y Especificidad
20.
J Cardiovasc Comput Tomogr ; 17(1): 11-17, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-35977872

RESUMEN

This manuscript has been written as a follow-up to the "AI/ML great debate" featured at the 2021 Society of Cardiovascular Computed Tomography (SCCT) Annual Scientific Meeting. In debate style, we highlighti the need for expectation management of AI/ML, debunking the hype around current AI techniques, and countering the argument that in its current day format AI/ML is the "silver bullet" for the interpretation of daily clinical CCTA practice.


Asunto(s)
Inteligencia Artificial , Motivación , Humanos , Valor Predictivo de las Pruebas , Corazón , Tomografía Computarizada por Rayos X
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...