1.
Arch Orthop Trauma Surg ; 144(2): 755-762, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38129717

RESUMEN

PURPOSE: To compare primary arthrodesis (PA) versus open reduction and internal fixation (ORIF) in displaced intra-articular calcaneal fractures (DIACFs), based on clinical outcome and 2D and 3D geometrical analyses obtained from weight-bearing (WB) cone-beam CT images. MATERIALS AND METHODS: In this prospective study, 40 patients with surgically treated calcaneal fractures were included, consisting of 20 PA and 20 ORIF patients. Weight-bearing cone-beam CT-images of the left and right hindfoot and forefoot were acquired on a Planmed Verity cone-beam CT-scanner after a minimum of 1-year follow-up. Automated 2D and 3D geometric analyses, i.e., (minimal and average) talo-navicular joint space, calcaneal pitch (CP), and Meary's angle (MA), were obtained for injured and healthy feet. Clinical outcomes were measured using the EQ5D and FFI questionnaires. RESULTS: Overall, there were no differences in baseline patient characteristics apart from age (p < 0.005). The calcaneal pitch in 2D after treatment by ORIF (13.8° ± 5.6) was closer to the uninjured side (18.1° ± 5.5) compared to PA (10.9° ± 4.5) (p < 0.001). Meary's angle in 2D was closer to the uninjured side (8.7° ± 6.3) after surgery in the PA cohort (7.0° ± 5.8) compared to the ORIF cohort (15.5° ± 5.9) (p = 0.046). In 3D measurements, CP was significantly decreased for both cohorts after surgery (- 4.09° ± 6.2) (p = 0.001). MA was not significantly affected overall or between cohorts in 3D. Clinical outcomes were not significantly different between the ORIF and PA cohorts. None of the radiographic measurements in 2D or 3D correlated with any of the clinical outcomes studied. CONCLUSION: Three-dimensional WB CT imaging enables functional 2D and 3D analyses under natural load in patients with complex calcaneal fractures. Based on clinical outcome, both PA and ORIF appear viable treatment options. Clinical correlation with geometrical outcomes remains to be established.


Asunto(s)
Traumatismos del Tobillo , Calcáneo , Traumatismos de los Pies , Fracturas Óseas , Fracturas Intraarticulares , Humanos , Fijación Interna de Fracturas/métodos , Estudios Prospectivos , Fracturas Óseas/diagnóstico por imagen , Fracturas Óseas/cirugía , Calcáneo/diagnóstico por imagen , Calcáneo/cirugía , Artrodesis , Tomografía Computarizada por Rayos X/métodos , Soporte de Peso , Resultado del Tratamiento , Fracturas Intraarticulares/diagnóstico por imagen , Fracturas Intraarticulares/cirugía
2.
Clin Biomech (Bristol, Avon) ; 110: 106126, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37883885

RESUMEN

BACKGROUND: This study assessed the use of dual-energy computed tomography (CT) to evaluate sub-calcaneal plantar fat pad changes in people with diabetic neuropathy. METHODS: Dual-energy CT scans of people with diabetic neuropathy and non-diabetic controls were retrospectively included. Average CT values (in Hounsfield Units) and thickness (in centimeters) of the sub-calcaneal plantar fat pad were measured in mono-energetic images at two energy levels (40 keV and 70 keV). The CT values measured in patients with diabetic neuropathy were correlated to barefoot plantar pressure measurements performed during walking in a clinical setting. FINDINGS: Forty-five dual-energy CT scans of people with diabetic neuropathy and eleven DECT scans of non-diabetic controls were included. Mean sub-calcaneal plantar fat pad thickness did not significantly differ between groups (diabetes group 1.20 ± 0.34 cm vs. control group 1.21 ± 0.28 cm, P = 0.585). CT values at both 40 keV (-34.7 ± 48.7 HU vs. -76.0 ± 42.8 HU, P = 0.013) and 70 keV (-11.2 ± 30.8 HU vs. -36.3 ± 27.2 HU, P = 0.017) were significantly higher in the diabetes group compared to controls, thus contained less fatty tissue. This elevation was most apparent in patients with Type 1 diabetes. CT values positively correlated with the mean peak plantar pressure. INTERPRETATION: Dual-energy CT was able to detect changes in the plantar fat pad of people with diabetic neuropathy.


Asunto(s)
Diabetes Mellitus Tipo 1 , Pie Diabético , Neuropatías Diabéticas , Humanos , Pie Diabético/diagnóstico por imagen , Neuropatías Diabéticas/diagnóstico por imagen , Estudios Retrospectivos , Tomografía Computarizada por Rayos X/métodos , Tejido Adiposo/diagnóstico por imagen
3.
Contemp Clin Trials Commun ; 33: 101107, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-36950303

RESUMEN

Foot ulcers are a frequent and costly problem in people with diabetes mellitus and can lead to amputations. Prevention of these ulcers is therefore of paramount importance. Claw/hammer toe deformities are commonly seen in people with diabetes. These deformities increase the risk of ulcer development specifically at the (tip of) the toe. Percutaneous needle tenotomy of the tendon of the m. flexor digitorum longus (tendon tenotomy) can be used to reduce the severity of claw/hammer toe deformity with the goal to prevent ulcer recurrence. The main objective of this randomized controlled trial is to assess the efficacy of flexor tenotomy to prevent recurrence of toe ulcers in people with diabetes and a history of toe (pre-)ulcers. Additionally, we aim to assess interphalangeal joints (IPJ) and metatarsophalangeal joint (MTPJ) angles in a weight-bearing and non-weight-bearing position, barefoot plantar pressure during walking, cost-effectiveness and quality of life before and after the intervention and compare intervention and control study groups. Sixty-six subjects with diabetes and claw/hammer toe deformity and a recent history of (pre-)ulceration on the tip of the toe will be included and randomized between flexor tenotomy of claw/hammer toes (intervention) versus standard of care including orthosis and shoe offloading (controls) in a mono-center randomized controlled trial. Clinicaltrialsgov registration: NCT05228340.

4.
Eur Radiol ; 33(8): 5645-5652, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-36820925

RESUMEN

OBJECTIVES: The purpose of this study is to evaluate the value of dual-energy CT (DECT) with virtual non-calcium (VNCa) in quantitatively assessing the presence of bone marrow edema (BME) in patients with diabetic foot ulcers and suspected osteomyelitis. METHODS: Patients with a diabetic foot ulcer and suspected osteomyelitis that underwent DECT (80 kVp/Sn150 kVp) with VNCa were retrospectively included. Two observers independently measured CT values of the bone adjacent to the ulcer and a reference bone not related to the ulcer. The patients were divided into two clinical groups, osteomyelitis or no-osteomyelitis, based on the final diagnosis by the treating physicians. RESULTS: A total of 56 foot ulcers were identified of which 23 were included in the osteomyelitis group. The mean CT value at the ulcer location was significantly higher in the osteomyelitis group (- 17.23 ± 34.96 HU) compared to the no-osteomyelitis group (- 69.34 ± 49.40 HU; p < 0.001). Within the osteomyelitis group, the difference between affected bone and reference bone was statistically significant (p < 0.001), which was not the case in the group without osteomyelitis (p = 0.052). The observer agreement was good for affected bone measurements (ICC = 0.858) and moderate for reference bone measurements (ICC = 0.675). With a cut-off value of - 40.1 HU, sensitivity was 87.0%, specificity was 72.7%, PPV was 69.0%, and NPV was 88.9%. CONCLUSION: DECT with VNCa has a potential value for quantitatively assessing the presence of BME in patients with diabetic foot ulcers and suspected osteomyelitis. KEY POINTS: • Dual-energy CT (DECT) with virtual non-calcium (VNCa) is promising for detecting bone marrow edema in the case of diabetic foot ulcers with suspected osteomyelitis. • DECT with VNCa has the potential to become a more practical alternative to MRI in assessing the presence of bone marrow edema in suspected osteomyelitis when radiographs are not sufficient to form a diagnosis.


Asunto(s)
Enfermedades de la Médula Ósea , Diabetes Mellitus , Pie Diabético , Osteomielitis , Humanos , Médula Ósea , Pie Diabético/complicaciones , Pie Diabético/diagnóstico por imagen , Estudios Retrospectivos , Sensibilidad y Especificidad , Tomografía Computarizada por Rayos X , Enfermedades de la Médula Ósea/diagnóstico , Osteomielitis/complicaciones , Osteomielitis/diagnóstico por imagen , Calcio , Edema/complicaciones , Edema/diagnóstico por imagen , Imagen por Resonancia Magnética
5.
Foot Ankle Surg ; 29(7): 538-543, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-36641368

RESUMEN

BACKGROUND: The aim of this study was to present and evaluate methods of measuring toe joint angels using joint-surface based and inertial axes approaches. METHODS: Nine scans of one frozen human cadaveric foot were obtained using weight-bearing CT. Two observers independently segmented bones in the forefoot and measured metatarsalphalangeal joint (MTPJ) angles, proximal and distal interphalangeal joint (PIPJ and DIPJ) angles and interphalangeal angles of the hallux (IPJ) using 1) inertial axes, representing the long anatomical axes, of the bones and 2) axes determined using centroids of articular joint surfaces. RESULTS: The standard deviations (SD) of the IPJ/PIPJ and DIPJ angles were lower using joint-surface based axes (between 1.5˚ and 4.1˚) than when the inertial axes method was used (between 3.3˚ and 16.4˚), for MTPJ the SD's were similar for both methods (between 0.5˚ and 2.6˚). For the IPJ/PIPJ and DIPJ angles, the width of the 95% CI and the range were also lower using the joint-surface axes method (95% CI: 2.0˚-4.1˚ vs 3.2˚-16.3˚; range: 3.1˚-7.4˚ vs 3.8˚-35.8˚). Intra-class correlation coefficients (ICC) representing inter- and intra-rater reliability were good to excellent regarding the MTPJ and IPJ/PIPJ angles in both techniques (between 0.85 and 0.99). For DIPJ angles, ICC's were good for the inertial axes method (0.78 and 0.79) and moderate for the joint-surface axes method (0.60 and 0.70). CONCLUSION: The joint-surface axes method enables reliable and reproducible measurements of MTPJ, IPJ/PIPJ and DIPJ angles. For PIPJ and DIPJ angles this method is preferable over the use of inertial axes.


Asunto(s)
Articulación Metatarsofalángica , Humanos , Articulación Metatarsofalángica/diagnóstico por imagen , Articulación Metatarsofalángica/cirugía , Reproducibilidad de los Resultados , Articulación del Dedo del Pie/diagnóstico por imagen , Tomografía Computarizada por Rayos X , Soporte de Peso
6.
Skeletal Radiol ; 52(7): 1313-1320, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-36585514

RESUMEN

OBJECTIVE: The aims of this study were to visualize and quantify relative bone positions in the feet of individuals with cerebral palsy (CP) with a foot deformity and compare bone positions with those of typically developed (TD) controls. MATERIALS AND METHODS: Weight-bearing CT images of 14 individuals with CP scheduled for tendon transfer and/or bony surgery and of 20 TD controls were acquired on a Planmed Verity WBCT scanner. Centroids of the navicular and calcaneus with respect to the talus were used to quantify foot deformities. All taluses were aligned and the size and dimensions of the individuals' talus were scaled to correct for differences in bone sizes. In order to visualize and quantify variations in relative bone positions, 95% CI ellipsoids and standard deviations in its principle X-, Y-, and Z-directions were determined. RESULTS: In individuals with CP (age 11-17), a large variation in centroid positions was observed compared to data of TD controls. Radiuses of the ellipsoids, representing the standard deviations of the 95% CI in the principle X-, Y-, and Z-directions, were larger in individuals with CP compared to TD controls for both the calcaneus (3.16 vs 1.86 mm, 4.26 vs 2.60 mm, 9.19 vs 3.60 mm) and navicular (4.63 vs 1.55 mm, 5.18 vs 2.10 mm, 16.07 vs 4.16 mm). CONCLUSION: By determining centroids of the calcaneus and navicular with respect to the talus on WBCT images, normal and abnormal relative bone positions can be visualized and quantified in individuals with CP with various foot deformities.


Asunto(s)
Calcáneo , Parálisis Cerebral , Deformidades del Pie , Astrágalo , Humanos , Niño , Adolescente , Parálisis Cerebral/complicaciones , Parálisis Cerebral/diagnóstico por imagen , Parálisis Cerebral/cirugía , Calcáneo/diagnóstico por imagen , Deformidades del Pie/diagnóstico por imagen , Soporte de Peso , Tomografía Computarizada por Rayos X
7.
Eur J Radiol ; 138: 109674, 2021 May.
Artículo en Inglés | MEDLINE | ID: mdl-33798932

RESUMEN

OBJECTIVES: We hypothesize that three-dimensional (3D) geometric analyses in weight bearing CT-images of the foot and ankle are more reproducible compared to two-dimensional (2D) analyses. Therefore, we compared 2D and 3D analyses on bones of weight-bearing and non weight-bearing cone-beam CT images of healthy volunteers. METHODS: Twenty healthy volunteers (10 male, 10 female, mean age 37.5 years) underwent weight-bearing and non weight-bearing cone-beam CT imaging of both feet. Clinically relevant height and angle measurements were performed in 2D and 3D (for example: cuboid height, calcaneal pitch, talo-calcaneal angle, Meary's angle, intermetatarsal angle). Three-dimensional measurements were obtained using automated software. Intra-observer and inter-observer agreement were evaluated for all 2D measurements. RESULTS: Overall intraclass correlation coefficients (ICC's) were higher than 0.750 for most 2D measurements, ranging from 0.352 to 0.995. Calcaneal pitch, angle between the first metatarsal (MT1) and proximal phalange 1, between the fifth metatarsal (MT5) and the calcaneus and heights of the sesamoid bones, navicular, cuboid and talus decreased during weight-bearing in both 2D and 3D results (p < 0.01). Meary's angle was not statistically different in 2D (p = 0.627) and 3D (p = 0.765). Higher coefficients of variation in 2D geometric analysis parameters (0.27 versus 0.16) indicate that 3D analyses are more precise compared to 2D (p < 0.01). Results of left and right feet are comparable for 2D and 3D analyses. CONCLUSION: Although 2D and 3D geometrical analyses are fundamentally different, automated 3D analyses are more reproducible and precise compared to 2D analyses. In addition, 3D evaluation better demonstrates differences in bone configurations between weight-bearing and non weight-bearing conditions, which may be of value to demonstrate pathology.


Asunto(s)
Tobillo , Tomografía Computarizada de Haz Cónico , Adulto , Articulación del Tobillo/diagnóstico por imagen , Femenino , Humanos , Masculino , Estándares de Referencia , Soporte de Peso
8.
Eur J Radiol ; 132: 109159, 2020 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-33091864

RESUMEN

PURPOSE: The aim of this study was to determine whether virtual monochromatic dual-energy CT imaging improves the evaluation of suspected non-union of the appendicular skeleton treated with titanium or stainless steel intramedullary nails and plates. METHOD: Forty-one patients with a clinical suspected non-union with hardware in place were included and scanned on a dual-source CT-scanner using 100/Sn150kVp. Images including titanium hardware were extracted at 130 keV. Images including stainless steel hardware were extracted at 150 keV. Monochromatic 70 keV images served as reference. Non-union confirmed during revision surgery was used as gold standard. A musculoskeletal radiologist and orthopedic trauma surgeon evaluated images on image quality, degree and location of consolidation, non-union type and diagnostic confidence. RESULTS: Likert scores with respect to image quality improved from 0.88 to 1.83 (p < 0.001) in high (130 and 150) keV images. High keV images reduced the number of false negative non-unions based on consolidation grade with 5% (p = 0.283). Agreement between observers regarding location of consolidation and non-union type did not improve in 130 and 150 keV images. Diagnostic confidence improved from 1.43 to 2.37 in high keV images compared to 70 keV images (p < 0.001). Overall diagnostic confidence was higher in intramedullary nails than plates (p < 0.05). CONCLUSIONS: Use of virtual monochromatic 130 and 150 keV dual-energy CT compared to 70 keV images improves the evaluation of suspected non-union of the appendicular skeleton treated with titanium or stainless steel intramedullary nails and plates.


Asunto(s)
Interpretación de Imagen Radiográfica Asistida por Computador , Imagen Radiográfica por Emisión de Doble Fotón , Humanos , Titanio , Tomografía Computarizada por Rayos X
9.
Clin Radiol ; 75(6): 448-456, 2020 06.
Artículo en Inglés | MEDLINE | ID: mdl-32070481

RESUMEN

AIM: To investigate possible differences between surgeons and radiologists in selecting optimal photon energy settings from a set of virtual monochromatic dual-energy computed tomography (CT) images for the assessment of bone union in patients with a suspected non-union of the appendicular skeleton. MATERIALS AND METHODS: Fifty patients suspected of having bone non-union after operative fracture treatment with a variety of fixation implants were included. Patients were scanned on a dual-source CT machine using 150/100-kVp. Monochromatic images were extracted at 70, 90, 110, 130, 150, and 190 keV. Images were reviewed by 159 orthopaedic trauma surgeons and 12 musculoskeletal radiologists in order to select the best and worst energy setting to assess bone union. Furthermore, a confidence score (1-4) was given in selecting the best and worst setting to assess bone union. RESULTS: Monochromatic 190 keV images were selected most frequently as the optimal energy in titanium (34.8%), stainless steel (40%), and combined implants of stainless steel and titanium (40.5%). Confidence scores and average optimal energies were higher and average worst energies were lower for radiologists compared to surgeons in all hardware (p<0.05). Differences in optimal energy were not statistically significant for different alloys or type of fixation implant in both groups. CONCLUSIONS: In both observer groups, 190 keV images were selected most frequently as the optimal energy to assess bone union in patients with a suspected non-union of the appendicular skeleton with hardware in situ. On average, musculoskeletal radiologists selected higher optimal and lower worst energy settings and were more confident in selecting both energy settings than orthopaedic trauma surgeons.


Asunto(s)
Fracturas no Consolidadas/diagnóstico por imagen , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Tomografía Computarizada por Rayos X/métodos , Consenso , Femenino , Fijación Interna de Fracturas/instrumentación , Fijación Interna de Fracturas/métodos , Fracturas no Consolidadas/cirugía , Humanos , Masculino , Fotones , Estudios Prospectivos , Prótesis e Implantes
10.
Phys Med ; 69: 9-18, 2020 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-31812728

RESUMEN

PURPOSE: To quantitatively assess CT image quality and fracture visibility using virtual monochromatic imaging and iterative metal artifact reduction (iMAR) in a femoral bone fracture phantom with different fixation implants. METHODS: A custom made phantom was scanned at 120-kVp and 140-kVp single-energy and 100/150-kVp dual-energy. Three stainless steel and two titanium implants with different thicknesses were placed on the phantom containing simulated one and two mm fractures. Single-energy CT images were reconstructed with and without iMAR, while DECT images were reconstructed at monochromatic energies between 70 and 190 keV. Non-metal scans were used as a reference. A Fourier power spectrum method and fracture model were used to analyze several anatomical areas. RESULTS: CT-value deviations of titanium implants were much lower compared to stainless steel implants. These deviations decreased for both DECT and iMAR. Fracture visibility, measured with the fracture model, improved the most when DECT was used while artifact reduction benefitted more from iMAR. The optimal monochromatic energy for metal artifact reduction, based on CT-value deviation, varied for each metal between 130 and 150 keV. The fracture model provided a signal-to-noise ratio for the near metal fracture visibility, providing the optimal keV. CONCLUSION: iMAR and high keV monochromatic images extracted from DECT both reduce metal artifacts caused by different metal fixation implants. Quantitative femoral phantom results show that DECT is superior to iMAR regarding fracture visualization adjacent to metal fixation implants. The introduction of new artifacts when using iMAR impedes its value in near metal fixation implant imaging.


Asunto(s)
Artefactos , Procesamiento de Imagen Asistido por Computador/métodos , Metales/química , Tomografía Computarizada por Rayos X , Fracturas del Fémur/cirugía , Fémur/diagnóstico por imagen , Fémur/fisiología , Análisis de Fourier , Humanos , Fantasmas de Imagen , Prótesis e Implantes , Relación Señal-Ruido , Titanio/química
11.
Eur J Radiol ; 107: 60-69, 2018 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-30292274

RESUMEN

It is known that metal artifacts can be reduced by modifying standard acquisition and reconstruction, by modifying projection data and/or image data and by using virtual monochromatic imaging extracted from dual-energy CT. In this review we focus on the origin of metal artifacts, technical background of commercially available metal artifact reduction (MAR) algorithms and the value of dual-energy CT and MAR software for different metal hardware in current clinical practice. Virtual monochromatic imaging reduces beam-hardening artifacts, where metal artifact reduction software effectively reduces artifacts caused by extensive photon-starvation. Both techniques have their advantages and disadvantages, and the combination of both techniques is often but not always the best solution regarding metal artifact reduction. Advances in prosthetic imaging are reinforced by advances in prosthetic design. Providing implant specific information prior to scanning is important in order to adjust the metal artifact reduction approach, minimize artifacts and optimize image quality and diagnostic value of CT.


Asunto(s)
Artefactos , Procesamiento de Imagen Asistido por Computador/métodos , Metales , Sistema Musculoesquelético/diagnóstico por imagen , Prótesis e Implantes , Tomografía Computarizada por Rayos X/métodos , Humanos , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Procedimientos de Cirugía Plástica
12.
Skeletal Radiol ; 46(5): 623-632, 2017 May.
Artículo en Inglés | MEDLINE | ID: mdl-28204857

RESUMEN

OBJECTIVE: To compare quantitative measures of image quality, in terms of CT number accuracy, noise, signal-to-noise-ratios (SNRs), and contrast-to-noise ratios (CNRs), at different dose levels with filtered-back-projection (FBP), iterative reconstruction (IR), and model-based iterative reconstruction (MBIR) alone and in combination with orthopedic metal artifact reduction (O-MAR) in a total hip arthroplasty (THA) phantom. MATERIALS AND METHODS: Scans were acquired from high- to low-dose (CTDIvol: 40.0, 32.0, 24.0, 16.0, 8.0, and 4.0 mGy) at 120- and 140- kVp. Images were reconstructed using FBP, IR (iDose4 level 2, 4, and 6) and MBIR (IMR, level 1, 2, and 3) with and without O-MAR. CT number accuracy in Hounsfield Units (HU), noise or standard deviation, SNRs, and CNRs were analyzed. RESULTS: The IMR technique showed lower noise levels (p < 0.01), higher SNRs (p < 0.001) and CNRs (p < 0.001) compared with FBP and iDose4 in all acquisitions from high- to low-dose with constant CT numbers. O-MAR reduced noise (p < 0.01) and improved SNRs (p < 0.01) and CNRs (p < 0.001) while improving CT number accuracy only at a low dose. At the low dose of 4.0 mGy, IMR level 1, 2, and 3 showed 83%, 89%, and 95% lower noise values, a factor 6.0, 9.2, and 17.9 higher SNRs, and 5.7, 8.8, and 18.2 higher CNRs compared with FBP respectively. CONCLUSIONS: Based on quantitative analysis of CT number accuracy, noise values, SNRs, and CNRs, we conclude that the combined use of IMR and O-MAR enables a reduction in radiation dose of 83% compared with FBP and iDose4 in the CT imaging of a THA phantom.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Artefactos , Procesamiento de Imagen Asistido por Computador/métodos , Metales , Dosis de Radiación , Tomografía Computarizada por Rayos X/métodos , Articulación de la Cadera/diagnóstico por imagen , Fantasmas de Imagen , Intensificación de Imagen Radiográfica/métodos , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Reproducibilidad de los Resultados
13.
Eur J Radiol ; 88: 61-70, 2017 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-28189210

RESUMEN

PURPOSE: To quantify the impact of prosthesis material and design on the reduction of metal artefacts in total hip arthroplasties using virtual monochromatic dual-layer detector Spectral CT imaging. METHODS: The water-filled total hip arthroplasty phantom was scanned on a novel 128-slice Philips IQon dual-layer detector Spectral CT scanner at 120-kVp and 140-kVp at a standard computed tomography dose index of 20.0mGy. Several unilateral and bilateral hip prostheses consisting of different metal alloys were inserted and combined which were surrounded by 18 hydroxyapatite calcium carbonate pellets representing bone. Images were reconstructed with iterative reconstruction and analysed at monochromatic energies ranging from 40 to 200keV. CT numbers in Hounsfield Units (HU), noise measured as the standard deviation in HU, signal-to-noise-ratios (SNRs) and contrast-to-noise-ratios (CNRs) were analysed within fixed regions-of-interests placed in and around the pellets. RESULTS: In 70 and 74keV virtual monochromatic images the CT numbers of the pellets were similar to 120-kVp and 140-kVp polychromatic results, therefore serving as reference. A separation into three categories of metal artefacts was made (no, mild/moderate and severe) where pellets were categorized based on HU deviations. At high keV values overall image contrast was reduced. For mild/moderate artefacts, the highest average CNRs were attained with virtual monochromatic 130keV images, acquired at 140-kVp. Severe metal artefacts were not reduced. In 130keV images, only mild/moderate metal artefacts were significantly reduced compared to 70 and 74keV images. Deviations in CT numbers, noise, SNRs and CNRs due to metal artefacts were decreased with respectively 64%, 57%, 62% and 63% (p<0.001) compared to unaffected pellets. Optimal keVs, based on CNRs, for different unilateral and bilateral metal hip prostheses consisting of different metal alloys varied from 74 to 150keV. The Titanium alloy resulted in less severe artefacts and were reduced more effectively compared to the Cobalt alloy. CONCLUSIONS: Virtual monochromatic dual-layer Spectral CT imaging results in a significant reduction of streak artefacts produced by beam-hardening in mild and moderate artefacts by improving CT number accuracy, SNRs and CNRs, while decreasing noise values in a total hip arthroplasty phantom. An optimal monochromatic energy of 130keV was found ranging from 74keV to 150keV for different unilateral and bilateral hip prostheses consisting of different metal alloys.


Asunto(s)
Artefactos , Prótesis de Cadera , Metales , Fantasmas de Imagen , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Tomografía Computarizada por Rayos X/métodos , Humanos , Relación Señal-Ruido , Titanio
SELECCIÓN DE REFERENCIAS