1.
Skeletal Radiol ; 2024 Jun 04.
Artículo en Inglés | MEDLINE | ID: mdl-38833168

RESUMEN

OBJECTIVE: This study aimed to quantitatively assess the diagnostic value of bone marrow edema (BME) detection on virtual non-calcium (VNCa) images calculated from dual-energy CT (DECT) in people with diabetes mellitus and suspected Charcot neuro-osteoarthropathy (CN). MATERIALS AND METHODS: People with diabetes mellitus and suspected CN who underwent DECT of the feet (80kVp/Sn150kVp) were included retrospectively. Two blinded observers independently measured CT values on VNCa images using circular regions of interest in five locations in the midfoot (cuneiforms, cuboid and navicular) and the calcaneus of the contralateral or (if one foot was available) the ipsilateral foot. Two clinical groups were formed, one with active CN and one without active CN (no-CN), based on the clinical diagnosis. RESULTS: Thirty-two people with diabetes mellitus and suspected CN were included. Eleven had clinically active CN. The mean CT value in the midfoot was significantly higher in the CN group (-55.6 ± 18.7 HU) compared to the no-CN group (-94.4 ± 23.5 HU; p < 0.001). In the CN group, the difference in CT value between the midfoot and calcaneus was statistically significant (p = 0.003); this was not the case in the no-CN group (p = 0.357). The overall observer agreement was good for the midfoot (ICC = 0.804) and moderate for the calcaneus (ICC = 0.712). Sensitivity was 100.0% and specificity was 71.4% using a cutoff value of -87.6 HU. CONCLUSION: The detection of BME on VNCa images has a potential value in people with diabetes mellitus and suspected active CN.

2.
EJNMMI Phys ; 11(1): 45, 2024 May 24.
Artículo en Inglés | MEDLINE | ID: mdl-38789880

RESUMEN

PURPOSE: Long axial field-of-view (LAFOV) PET/CT systems enable PET/CT scans with reduced injected activities because of improved sensitivity. With this study, we aimed to examine the foetal radiation dose from an 18F-FDG PET/CT scan on a LAFOV PET/CT system with reduced injected activity. METHODS: Two pregnant women were retrospectively included and received an 18F-FDG PET/CT scan on a LAFOV PET/CT system with an intravenous bolus injection of 0.30 MBq/kg. Foetal radiation exposure from the PET was estimated using dose conversion factors from three published papers. Radiation exposure from the CT scans was estimated using CT-Expo. RESULTS: Foetal radiation dose from the PET scan ranged between 0.11 and 0.44 mGy. Foetal radiation exposure from the CT scan ranged between < 0.10 - 0.90 mGy depending if the foetus was included in the field-of-view. CONCLUSION: Foetal radiation dose could be reduced to < 1.5 mGy when scanning pregnant patients on a LAFOV PET/CT system. The radiation dose to the foetus was reduced significantly in our study due to the increased sensitivity of the LAFOV PET/CT system.

3.
Eur Radiol Exp ; 8(1): 31, 2024 Mar 14.
Artículo en Inglés | MEDLINE | ID: mdl-38480603

RESUMEN

BACKGROUND: To compare image quality, metal artifacts, and diagnostic confidence of conventional computed tomography (CT) images of unilateral total hip arthroplasty patients (THA) with deep learning-based metal artifact reduction (DL-MAR) to conventional CT and 130-keV monoenergetic images with and without orthopedic metal artifact reduction (O-MAR). METHODS: Conventional CT and 130-keV monoenergetic images with and without O-MAR and DL-MAR images of 28 unilateral THA patients were reconstructed. Image quality, metal artifacts, and diagnostic confidence in bone, pelvic organs, and soft tissue adjacent to the prosthesis were jointly scored by two experienced musculoskeletal radiologists. Contrast-to-noise ratios (CNR) between bladder and fat and muscle and fat were measured. Wilcoxon signed-rank tests with Holm-Bonferroni correction were used. RESULTS: Significantly higher image quality, higher diagnostic confidence, and less severe metal artifacts were observed on DL-MAR and images with O-MAR compared to images without O-MAR (p < 0.001 for all comparisons). Higher image quality, higher diagnostic confidence for bone and soft tissue adjacent to the prosthesis, and less severe metal artifacts were observed on DL-MAR when compared to conventional images and 130-keV monoenergetic images with O-MAR (p ≤ 0.014). CNRs were higher for DL-MAR and images with O-MAR compared to images without O-MAR (p < 0.001). Higher CNRs were observed on DL-MAR images compared to conventional images and 130-keV monoenergetic images with O-MAR (p ≤ 0.010). CONCLUSIONS: DL-MAR showed higher image quality, diagnostic confidence, and superior metal artifact reduction compared to conventional CT images and 130-keV monoenergetic images with and without O-MAR in unilateral THA patients. RELEVANCE STATEMENT: DL-MAR resulted into improved image quality, stronger reduction of metal artifacts, and improved diagnostic confidence compared to conventional and virtual monoenergetic images with and without metal artifact reduction, bringing DL-based metal artifact reduction closer to clinical application. KEY POINTS: • Metal artifacts introduced by total hip arthroplasty hamper radiologic assessment on CT. • A deep-learning algorithm (DL-MAR) was compared to dual-layer CT images with O-MAR. • DL-MAR showed best image quality and diagnostic confidence. • Highest contrast-to-noise ratios were observed on the DL-MAR images.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Aprendizaje Profundo , Humanos , Tomografía Computarizada por Rayos X/métodos , Artefactos , Algoritmos
4.
Eur J Radiol ; 170: 111276, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38142571

RESUMEN

Metal artifacts degrade CT image quality, hampering clinical assessment. Numerous metal artifact reduction methods are available to improve the image quality of CT images with metal implants. In this review, an overview of traditional methods is provided including the modification of acquisition and reconstruction parameters, projection-based metal artifact reduction techniques (MAR), dual energy CT (DECT) and the combination of these techniques. Furthermore, the additional value and challenges of novel metal artifact reduction techniques that have been introduced over the past years are discussed such as photon counting CT (PCCT) and deep learning based metal artifact reduction techniques.


Asunto(s)
Artefactos , Tomografía Computarizada por Rayos X , Humanos , Tomografía Computarizada por Rayos X/métodos , Prótesis e Implantes , Metales , Algoritmos
6.
Eur J Radiol ; 163: 110844, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-37119708

RESUMEN

PURPOSE: To develop a deep learning-based metal artifact reduction technique (dl-MAR) and quantitatively compare metal artifacts on dl-MAR-corrected CT-images, orthopedic metal artifact reduction (O-MAR)-corrected CT-images and uncorrected CT-images after sacroiliac (SI) joint fusion. METHODS: dl-MAR was trained on CT-images with simulated metal artifacts. Pre-surgery CT-images and uncorrected, O-MAR-corrected and dl-MAR-corrected post-surgery CT-images of twenty-five patients undergoing SI joint fusion were retrospectively obtained. Image registration was applied to align pre-surgery with post-surgery CT-images within each patient, allowing placement of regions of interest (ROIs) on the same anatomical locations. Six ROIs were placed on the metal implant and the contralateral side in bone lateral of the SI joint, the gluteus medius muscle and the iliacus muscle. Metal artifacts were quantified as the difference in Hounsfield units (HU) between pre- and post-surgery CT-values within the ROIs on the uncorrected, O-MAR-corrected and dl-MAR-corrected images. Noise was quantified as standard deviation in HU within the ROIs. Metal artifacts and noise in the post-surgery CT-images were compared using linear multilevel regression models. RESULTS: Metal artifacts were significantly reduced by O-MAR and dl-MAR in bone (p < 0.001), contralateral bone (O-MAR: p = 0.009; dl-MAR: p < 0.001), gluteus medius (p < 0.001), contralateral gluteus medius (p < 0.001), iliacus (p < 0.001) and contralateral iliacus (O-MAR: p = 0.024; dl-MAR: p < 0.001) compared to uncorrected images. Images corrected with dl-MAR resulted in stronger artifact reduction than images corrected with O-MAR in contralateral bone (p < 0.001), gluteus medius (p = 0.006), contralateral gluteus medius (p < 0.001), iliacus (p = 0.017), and contralateral iliacus (p < 0.001). Noise was reduced by O-MAR in bone (p = 0.009) and gluteus medius (p < 0.001) while noise was reduced by dl-MAR in all ROIs (p < 0.001) in comparison to uncorrected images. CONCLUSION: dl-MAR showed superior metal artifact reduction compared to O-MAR in CT-images with SI joint fusion implants.


Asunto(s)
Aprendizaje Profundo , Tomografía Computarizada por Rayos X , Humanos , Tomografía Computarizada por Rayos X/métodos , Artefactos , Articulación Sacroiliaca/diagnóstico por imagen , Articulación Sacroiliaca/cirugía , Estudios Retrospectivos , Algoritmos
7.
Skeletal Radiol ; 52(6): 1073-1088, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-36350387

RESUMEN

Weight bearing CT (WBCT) of the lower extremity is gaining momentum in evaluation of the foot/ankle and knee. A growing number of international studies use WBCT, which is promising for improving our understanding of anatomy and biomechanics during natural loading of the lower extremity. However, we believe there is risk of excessive enthusiasm for WBCT leading to premature application of the technique, before sufficiently robust protocols are in place e.g. standardised limb positioning and imaging planes, choice of anatomical landmarks and image slices used for individual measurements. Lack of standardisation could limit benefits from introducing WBCT in research and clinical practice because useful imaging information could become obscured. Measurements of bones and joints on WBCT are influenced by joint positioning and magnitude of loading, factors that need to be considered within a 3-D coordinate system. A proportion of WBCT studies examine inter- and intraobserver reproducibility for different radiological measurements in the knee or foot with reproducibility generally reported to be high. However, investigations of test-retest reproducibility are still lacking. Thus, the current ability to evaluate, e.g. the effects of surgery or structural disease progression, is questionable. This paper presents an overview of the relevant literature on WBCT in the lower extremity with an emphasis on factors that may affect measurement reproducibility in the foot/ankle and knee. We discuss the caveats of performing WBCT without consensus on imaging procedures and measurements.


Asunto(s)
Tomografía Computarizada de Haz Cónico , Motivación , Humanos , Reproducibilidad de los Resultados , Pie , Soporte de Peso
8.
Diabet Med ; 39(4): e14761, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-34877692

RESUMEN

OBJECTIVE: To assess the effect of flexor tenotomy in patients with diabetes on barefoot plantar pressure, toe joint angles and ulcer recurrence during patient follow-up. METHODS: Patients with a history of ulceration on the toe apex were included. They underwent minimally invasive needle flexor tenotomy by an experienced musculoskeletal surgeon. Dynamic barefoot plantar pressure measurements and static weight-bearing radiographs were taken before and 2-4 weeks after the procedure. RESULTS: A total of 14 patients underwent flexor tenotomy on 50 toes in 19 feet. There was a mean follow-up time of 11.4 months. No ulcer recurrence occurred during follow-up. Mean barefoot plantar pressure was assessed on 34 toes and decreased significantly after the procedure by a mean 279 kPa (95% CI: 204-353; p < 0.001). Metatarsophalangeal, proximal interphalangeal and distal interphalangeal joint angles were assessed on nine toes and all decreased significantly (by 7° [95% CI: 4-9; p < 0.001], 19° [95% CI: 11-26; p < 0.001] and 28° [95% CI: 13-44; p = 0.003], respectively). CONCLUSION: These observations show a beneficial effect of flexor tenotomy on biomechanical and musculoskeletal outcomes in the toes, without ulcer recurrence.


Asunto(s)
Diabetes Mellitus , Pie Diabético , Neuropatías Diabéticas , Úlcera del Pie , Pie Diabético/cirugía , Neuropatías Diabéticas/cirugía , Úlcera del Pie/etiología , Úlcera del Pie/prevención & control , Úlcera del Pie/cirugía , Humanos , Tenotomía/métodos , Dedos del Pie/cirugía , Úlcera
9.
Insights Imaging ; 12(1): 171, 2021 Nov 24.
Artículo en Inglés | MEDLINE | ID: mdl-34817722

RESUMEN

OBJECTIVE: To quantify metal artifact reduction using 130 keV virtual monochromatic imaging (VMI) with and without orthopedic metal artifact reduction (O-MAR) in total hip arthroplasty. METHODS: Conventional polychromatic images and 130 keV VMI of a phantom with pellets representing bone with unilateral or bilateral prostheses were reconstructed with and without O-MAR on a dual-layer CT. Pellets were categorized as unaffected, mildly affected and severely affected. RESULTS: When 130 keV VMI with O-MAR was compared to conventional imaging with O-MAR, a relative metal artifact reduction in CT values, contrast-to-noise (CNR), signal-to-noise (SNR) and noise in mildly affected pellets (67%, 74%, 48%, 68%, respectively; p < 0.05) was observed but no significant relative metal artifact reduction in severely affected pellets. Comparison between 130 keV VMI without O-MAR and conventional imaging with O-MAR showed relative metal artifact reduction in CT values, CNR, SNR and noise in mildly affected pellets (92%, 72%, 38%, 51%, respectively; p < 0.05) but negative relative metal artifact reduction in CT values and noise in severely affected pellets (- 331% and -223%, respectively; p < 0.05), indicating aggravation of metal artifacts. CONCLUSION: Overall, VMI of 130 keV with O-MAR provided the strongest metal artifact reduction.

10.
Skeletal Radiol ; 48(11): 1775-1785, 2019 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-31016340

RESUMEN

OBJECTIVE: To evaluate the impact of radiation dose reduction on image quality in patients with metal-on-metal total hip arthroplasties (THAs) using model-based iterative reconstruction (MBIR) combined with orthopaedic metal artefact reduction (O-MAR). MATERIALS AND METHODS: Patients with metal-on-metal THAs received a pelvic CT with a full (FD) and a reduced radiation dose (RD) with -20%, -40%, -57%, or -80% CT radiation dose respectively, when assigned to group 1, 2, 3, or 4 respectively. FD acquisitions were reconstructed with iterative reconstruction, iDose4. RD acquisitions were additionally reconstructed with iterative model-based reconstruction (IMR) levels 1-3 with different levels of noise suppression. CT numbers, noise and contrast-to-noise ratios were measured in muscle, fat and bladder. Subjective image quality was evaluated on seven aspects including artefacts, osseous structures, prosthetic components and soft tissues. RESULTS: Seventy-six patients were randomly assigned to one of the four groups. While reducing radiation dose by 20%, 40%, 57%, or 80% in combination with IMR, CT numbers remained constant. Compared with iDose4, the noise decreased (p < 0.001) and contrast-to-noise ratios increased (p < 0.001) with IMR. O-MAR improved CT number accuracy in the bladder and reduced noise in the bladder, muscle and fat (p < 0.01). Subjective image quality was rated lower on RD IMR images than FD iDose4 images on all seven aspects (p < 0.05) and was not related to the applied radiation dose reduction. CONCLUSION: In RD IMR with O-MAR images, CT numbers remained constant, noise decreased and contrast-to-noise ratios between muscle and fat increased compared with FD iDose4 with O-MAR images in patients with metal-on-metal THAs. Subjective image quality reduced, regardless of the degree of radiation dose reduction.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Artefactos , Articulación de la Cadera/diagnóstico por imagen , Dosis de Radiación , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Tomografía Computarizada por Rayos X/métodos , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Metales , Persona de Mediana Edad , Ortopedia , Reproducibilidad de los Resultados
11.
Skeletal Radiol ; 47(6): 839-845, 2018 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-28842739

RESUMEN

OBJECTIVE: To quantify and optimize metal artifact reduction using virtual monochromatic dual-energy CT for different metal implants compared to non-metal reference scans. METHODS: Dual-energy CT scans of a pair of human cadaver limbs were acquired before and after implanting a titanium tibia plate, a stainless-steel tibia plate and a titanium intramedullary nail respectively. Virtual monochromatic images were analyzed from 70 to 190 keV. Region-of-interest (ROI), used to determine fluctuations and inaccuracies in CT numbers of soft tissues and bone, were placed in muscle, fat, cortical bone and intramedullary tibia canal. RESULTS: The stainless-steel implant resulted in more pronounced metal artifacts compared to both titanium implants. CT number inaccuracies in 70 keV reference images were minimized at 130, 180 and 190 keV for the titanium tibia plate, stainless-steel tibia plate and titanium intramedullary nail respectively. Noise, measured as the standard deviation of pixels within a ROI, was minimized at 130, 150 and 140 keV for the titanium tibia plate, stainless-steel tibia plate and titanium intramedullary nail respectively. CONCLUSION: Tailoring dual-energy CT protocols using implant specific virtual monochromatic images minimizes fluctuations and inaccuracies in CT numbers in bone and soft tissues compared to non-metal reference scans.


Asunto(s)
Artefactos , Prótesis e Implantes , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Tibia , Tomografía Computarizada por Rayos X/métodos , Cadáver , Humanos , Acero Inoxidable , Tibia/diagnóstico por imagen , Tibia/cirugía , Titanio
12.
J Comput Assist Tomogr ; 40(6): 971-978, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27331924

RESUMEN

OBJECTIVES: To quantify the combined use of iterative model-based reconstruction (IMR) and orthopaedic metal artefact reduction (O-MAR) in reducing metal artefacts and improving image quality in a total hip arthroplasty phantom. METHODS: Scans acquired at several dose levels and kVps were reconstructed with filtered back-projection (FBP), iterative reconstruction (iDose) and IMR, with and without O-MAR. Computed tomography (CT) numbers, noise levels, signal-to-noise-ratios and contrast-to-noise-ratios were analysed. RESULTS: Iterative model-based reconstruction results in overall improved image quality compared to iDose and FBP (P < 0.001). Orthopaedic metal artefact reduction is most effective in reducing severe metal artefacts improving CT number accuracy by 50%, 60%, and 63% (P < 0.05) and reducing noise by 1%, 62%, and 85% (P < 0.001) whereas improving signal-to-noise-ratios by 27%, 47%, and 46% (P < 0.001) and contrast-to-noise-ratios by 16%, 25%, and 19% (P < 0.001) with FBP, iDose, and IMR, respectively. CONCLUSIONS: The combined use of IMR and O-MAR strongly improves overall image quality and strongly reduces metal artefacts in the CT imaging of a total hip arthroplasty phantom.


Asunto(s)
Artefactos , Articulación de la Cadera/diagnóstico por imagen , Prótesis de Cadera , Intensificación de Imagen Radiográfica/métodos , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Tomografía Computarizada por Rayos X/métodos , Algoritmos , Articulación de la Cadera/cirugía , Humanos , Metales , Fantasmas de Imagen , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Tomografía Computarizada por Rayos X/instrumentación