Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
J AOAC Int ; 97(3): 868-75, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-25051636

RESUMEN

A multilaboratory study was conducted to evaluate the ability of the DuPont BAX System Real-Time PCR Assay for Salmonella to detect the target species in a variety of foods and environmental surfaces. Internal validation studies were performed by DuPont Nutrition & Health on 24 different sample types to demonstrate the reliability of the test method among a wide variety of sample types. Two of these matrixes-pork and turkey frankfurters and pasteurized, not-from-concentrate orange juice without pulp-were each evaluated in 14 independent laboratories as part of the collaborative study to demonstrate repeatability and reproducibility of the internal laboratory results independent of the end user. Frankfurter samples were evaluated against the U.S. Department of Agriculture, Food Safety and Inspection Service reference method as a paired study, while orange juice samples were evaluated against the U.S. Food and Drug Administration reference method as an unpaired study, using a proprietary media for the test method. Samples tested in this study were artificially inoculated with a Salmonella strain at levels expected to produce low (0.2-2.0 CFU/test portion) or high (5 CFU/test portion) spike levels on the day of analysis. For each matrix, the collaborative study failed to show a statistically significant difference between the candidate method and the reference method using the probability of detection statistical model.


Asunto(s)
Técnicas Bacteriológicas/métodos , Microbiología de Alimentos , Reacción en Cadena en Tiempo Real de la Polimerasa/métodos , Salmonella/aislamiento & purificación , Reproducibilidad de los Resultados , Salmonella/genética
2.
Int Arch Occup Environ Health ; 84(3): 267-77, 2011 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-20496180

RESUMEN

PURPOSE: Recent research by the authors on the effects of extremely low-frequency (ELF) magnetic field (MF) exposure on human heart rate (HR), heart rate variability (HRV), and skin blood perfusion found no cardiovascular effects of exposure to an 1,800-µT, 60-Hz MF. Research from our group using rats, however, has suggested a microcirculatory response to a 200-µT, 60-Hz MF exposure. The present pilot study investigated the effects of 1 h of exposure to a 200-µT, 60-Hz MF on the human circulation. Microcirculation (as skin blood perfusion) and HR were measured using laser Doppler flowmetry. Mean arterial pressure was monitored with a non-invasive blood pressure system. METHODS: Ten volunteers were recruited to partake in a counterbalanced, single-blinded study consisting of two testing sessions (real and sham exposure) administered on separate days. Each session included four consecutive measurement periods separated by rest, allowing assessment of cumulative and residual MF effects. RESULTS: A within-subjects analysis of variance did not reveal session by time period interactions for any of the parameters which would have been suggestive of a MF effect (p > 0.05). Perfusion, HR, and skin surface temperature decreased over the course of the experiment (p < 0.05). CONCLUSIONS: The MF used in this experiment did not affect perfusion, HR, or mean arterial pressure. Decreasing perfusion and HR trends over time were similar to our previous results and appear to be associated with a combination of inactivity (resulting in decreasing body temperatures) and reduced physiological arousal.


Asunto(s)
Campos Electromagnéticos/efectos adversos , Dedos/efectos de la radiación , Microcirculación/efectos de la radiación , Piel/efectos de la radiación , Adolescente , Adulto , Femenino , Dedos/irrigación sanguínea , Hemodinámica/efectos de la radiación , Humanos , Flujometría por Láser-Doppler , Masculino , Microcirculación/fisiología , Persona de Mediana Edad , Proyectos Piloto , Piel/irrigación sanguínea , Adulto Joven
3.
Neurosci Lett ; 482(2): 160-2, 2010 Sep 27.
Artículo en Inglés | MEDLINE | ID: mdl-20643187

RESUMEN

Functional magnetic resonance imaging (fMRI) was used to investigate the dose-response relationship (sham, 100, 200, 1000 microT) between a pulsed extremely low frequency magnetic field (ELFMF) and acute thermal pain on the dominant right hand. Forty-seven participants were recruited, and pulsed ELFMF was applied through the MRI gradient system using a novel technique. Regions of interest (ROIs) matching those of previous studies were examined for a potential dose response. Significant correlations between applied field strength and change in BOLD activity were found in the anterior cingulate and the ipsilateral insula, indicating that there might be either a dose response or a threshold effect of the ELFMF.


Asunto(s)
Encéfalo/efectos de la radiación , Campos Electromagnéticos , Dolor/fisiopatología , Enfermedad Aguda , Adulto , Encéfalo/fisiopatología , Mapeo Encefálico , Relación Dosis-Respuesta en la Radiación , Humanos , Imagen por Resonancia Magnética , Percepción del Dolor , Temperatura , Adulto Joven
4.
Bioelectromagnetics ; 31(6): 445-53, 2010 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-20564168

RESUMEN

For 8 weeks, adult CD-1 male mice were continuously exposed to complex time-varying pulsed magnetic fields (PMF) generated in the horizontal direction by a set of square Helmholtz coils. The PMF were <1000 Hz and delivered at a peak flux density of 1 mT. Sham-exposed mice were kept in a similar exposure system without a PMF. Positive control animals exposed to 1 Gy gamma radiation were also included in the study. Blood samples were collected before (time 0) and at 2, 4, 6, and 8 weeks. All mice were euthanized at the end of 8 weeks and their bone marrow was collected. From each blood and bone marrow sample, smears were prepared on microscope slides, fixed in absolute methanol, air-dried, and stained with acridine orange. All slides were coded and examined using a fluorescence microscope. The extent of genotoxicity and cytotoxicity was assessed from the incidence of micronuclei (MN) and percent polychromatic erythrocytes (PCE) in the blood and bone marrow, respectively. The data indicated that both indices in PMF-exposed mice were not significantly different from those observed in sham-exposed animals. In contrast, positive control mice exhibited significantly increased MN, and decreased percentages of PCE in both tissues. Thus, the overall data suggested that 8 weeks of continuous exposure to PMF did not induce significantly increased genotoxicity and cytotoxicity in experimental mice. Further investigations are underway using other genotoxicity assays (comet assay, gamma-H2AX foci, and chromosomal aberrations) to assess genotoxicity following PMF exposure.


Asunto(s)
Células Sanguíneas/metabolismo , Células Sanguíneas/efectos de la radiación , Células de la Médula Ósea/metabolismo , Células de la Médula Ósea/efectos de la radiación , Campos Electromagnéticos/efectos adversos , Micronúcleos con Defecto Cromosómico , Animales , Células Sanguíneas/citología , Células de la Médula Ósea/citología , Eritrocitos/citología , Eritrocitos/efectos de la radiación , Masculino , Ratones , Pruebas de Micronúcleos , Factores de Tiempo
5.
J R Soc Interface ; 7(44): 467-73, 2010 Mar 06.
Artículo en Inglés | MEDLINE | ID: mdl-19656823

RESUMEN

Extremely low-frequency magnetic fields (from DC to 300 Hz) have been shown to affect pain sensitivity in snails, rodents and humans. Here, a functional magnetic resonance imaging study demonstrates how the neuromodulation effect of these magnetic fields influences the processing of acute thermal pain in normal volunteers. Significant interactions were found between pre- and post-exposure activation between the sham and exposed groups for the ipsilateral (right) insula, anterior cingulate and bilateral hippocampus/caudate areas. These results show, for the first time, that the neuromodulation induced by exposure to low-intensity low-frequency magnetic fields can be observed in humans using functional brain imaging and that the detection mechanism for these effects may be different from those used by animals for orientation and navigation. Magnetoreception may be more common than presently thought.


Asunto(s)
Campos Electromagnéticos/efectos adversos , Exposición a Riesgos Ambientales/análisis , Dolor , Transmisión Sináptica/efectos de la radiación , Adolescente , Adulto , Encéfalo/patología , Encéfalo/efectos de la radiación , Humanos , Imagen por Resonancia Magnética , Persona de Mediana Edad , Estimulación Física
6.
Int Arch Occup Environ Health ; 83(4): 441-54, 2010 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-19902234

RESUMEN

PURPOSE: Previously published literature has suggested an effect of extremely low-frequency (ELF) magnetic fields (MF) on human heart rate (HR) and heart rate variability (HRV). The combined response of the microcirculation and macrocirculation to ELF MF exposure has not previously been studied in humans. This study investigated the effects of 1-h exposure to an 1800-muT, 60-Hz MF on human microcirculation (represented in this study as skin blood perfusion), HR, low-frequency HRV, and high-frequency HRV. METHODS: Fifty-eight volunteers were recruited to partake in a double-blinded, counterbalanced study consisting of two testing sessions (real and sham) administered on separate days. Each session included four consecutive blocks of measurements, separated by 15-min rest periods, allowing measurement of cumulative and residual MF effects. Within subjects, ANOVA were conducted on each of the measured parameters. RESULTS: A decrease of skin blood perfusion and HR, and an increase of HRV were observed over blocks (p < 0.05). No session by block interactions were found for any of the cardiovascular parameters which would have suggested a MF effect (p > 0.05). A session by block interaction (p < 0.001) and a MF order effect (sham or real exposure first, p < 0.05) were observed for skin surface temperature. CONCLUSIONS: The MF used in this experiment did not affect cardiovascular parameters. Although an alternative explanation for why skin surface temperatures decreased in the sham and not in the real exposure condition is presented, the possibility of a MF effect cannot be excluded.


Asunto(s)
Campos Electromagnéticos/efectos adversos , Frecuencia Cardíaca/efectos de la radiación , Microcirculación/efectos de la radiación , Adolescente , Adulto , Método Doble Ciego , Femenino , Humanos , Masculino , Persona de Mediana Edad , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA