Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Foods ; 13(13)2024 Jul 08.
Artículo en Inglés | MEDLINE | ID: mdl-38998663

RESUMEN

In the present study, a new degraded konjac glucomannan (DKGM) was prepared using a crude enzyme from abalone (Haliotis discus hannai) viscera, and its physicochemical properties were investigated. After enzymatic hydrolysis, the viscosity of KGM obviously decreased from 15,500 mPa·s to 398 mPa·s. The rheological properties analysis of KGM and DKGMs revealed that they were pseudoplastic fluids, and pseudoplasticity, viscoelasticity, melting temperature, and gelling temperature significantly decreased after enzymatic hydrolysis, especially for KGM-180 and KGM-240. In addition, the molecular weight of KGM decreased from 1.80 × 106 Da, to 0.45 × 106 Da and the polydispersity index increased from 1.17 to 1.83 after 240 min of degradation time. Compared with natural KGM, the smaller particle size distribution of DKGM further suggests enzyme hydrolysis reduces the aggregation of molecular chains with low molecular weight. FT-IR and FESEM analyses showed that the fragmented KMG chain did not affect the structural characteristics of molecular monomers; however, the dense three-dimensional network microstructure formed by intermolecular interaction changed to fragment microstructure after enzyme hydrolysis. These results revealed that the viscosity and rheological properties of KGM could be controlled and effectively changed using crude enzymes from abalone viscera. This work provides theoretical guidance for the promising application of DKGM in the food industry.

2.
BMC Nurs ; 23(1): 219, 2024 Mar 29.
Artículo en Inglés | MEDLINE | ID: mdl-38553742

RESUMEN

BACKGROUND: Guaranteeing nursing service safety and quality is a prioritized issue in the healthcare setting worldwide. However, there still lacks a valid scale to measure the quality and safety competencies of newly graduated nurses globally. METHODS: This scale was developed in two phases. In Phase One, a literature review and three-round e-Delphi were conducted to generate the initial item pool; while in Phase Two, five experts tested the content validity of the scale. The construct validity was evaluated using confirmatory factor analysis (CFA), and the data were collected among 1,221 newly graduated nursing students between May, 2017 and August, 2017. Finally, the internal consistency reliability and test-retest reliability were tested. RESULTS: The final version's Competency Scale of Quality and Safety (CSQS) was confirmed by the CFA involving 64 items in six dimensions, including patient-center care, safety, evidence-based practice, collaboration and teamwork, continuous quality improvement, and informatics. The results of data showed that the data supported the modified model of CSQS (Standardized Root Mean Square Residual = 0.03, p = 0.053, Adjusted Goodness of Normed Fit Index = 1.00, Root Mean Square Error of Approximation = 0.007, Fit Index = 0.95, Goodness of Fit Index = 0.97, χ2/df = 1.06), and the standardized factor loadings of items were from 0.59 to 0.74 (p < 0.05). The internal consistency reliability of the total scale was 0.98, and the test-retest reliability was 0.89. CONCLUSIONS: CSQS was a valid and reliable instrument to measure the safety and quality abilities of greenhand nurses, and could be fully utilized by nursing students, greenhand nurses, nursing educators, as well as hospital nursing managers.

3.
J Arthroplasty ; 39(9): 2248-2253, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38508345

RESUMEN

BACKGROUND: There is an increasing number of different brands of robotic total knee arthroplasty (TKA) systems. Most robotic TKA systems share the same coronal alignment, while the definitions of sagittal alignment vary. The purpose of this study was to investigate whether these discrepancies impact the sagittal alignment of the lower extremity. METHODS: A total of 72 lower extremity computed tomography scans were included in our study, and 3-dimensional models were obtained using software. A total of 7 brands of robotic TKA systems were included in the study. The lower extremity axes were defined based on the surgical guide for each implant. We also set the intramedullary axis as a reference to evaluate the discrepancies in sagittal alignment of each brand of robotic system. RESULTS: On the femoral side, the axis definition was the same for all 7 robotic TKA systems. The robotic TKA axes showed a 2.41° (1.58°, 3.38°) deviation from the intramedullary axis. On the tibial side, the 7 robots had different axis definitions. The tibial mechanical axis of 6 of the TKA systems was more flexed than that of the intramedullary axis, which means the posterior tibial slope was decreased while the tibial mechanical axis of the remaining system was more extended. CONCLUSIONS: The sagittal alignment of the lower extremity for 7 different brands of robotic TKA systems differed from each other and all deviated from the intramedullary axis. Surgeons should be aware of this discrepancy when using different brands of robotic TKA systems to avoid unexpected sagittal alignment and corresponding adverse clinical outcomes. LEVEL OF EVIDENCE: Level IV, Therapeutic Study.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Procedimientos Quirúrgicos Robotizados , Humanos , Artroplastia de Reemplazo de Rodilla/métodos , Artroplastia de Reemplazo de Rodilla/instrumentación , Procedimientos Quirúrgicos Robotizados/métodos , Masculino , Femenino , Articulación de la Rodilla/cirugía , Articulación de la Rodilla/diagnóstico por imagen , Tomografía Computarizada por Rayos X , Prótesis de la Rodilla , Tibia/cirugía , Tibia/diagnóstico por imagen , Anciano , Extremidad Inferior/cirugía , Extremidad Inferior/diagnóstico por imagen , Fémur/cirugía , Fémur/diagnóstico por imagen , Persona de Mediana Edad , Imagenología Tridimensional
4.
Iran J Basic Med Sci ; 23(3): 329-336, 2020 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-32440319

RESUMEN

OBJECTIVES: To investigate the role of miR-22 in the efficacy of combined icotinib (BPI-2009H) and pemetrexed (LY-231514) on tumor growth and apoptosis in rats with non-small cell lung cancer (NSCLC). MATERIALS AND METHODS: Rats were injected with HCC827 cells, which were transfected with anti-miR-22, followed by the treatment of BPI-2009H and/or LY-231514. MTT assay was used to detect the inhibition rate of HCC827 cells. qRT-PCR was performed to examine miR-22 expression in HCC827 cells and lung tumor tissues. Moreover, immunohistochemistry and Western blotting were performed to detect the related-molecule expressions, while TUNEL staining was used to observe cell apoptosis of lung tumor tissues. RESULTS: MiR-22 expression was decreased in HCC827 cells after the treatment of BPI-2009H or LY-231514 in a dose-dependent manner. Both BPI-2009H and LY-231514 increased the inhibition rate of HCC827 cells, which was enhanced by anti-miR-22 with decreased IC50 values. Furthermore, the decreased expression of miR-22 was found after the treatment of BPI-2009H or/and LY-231514 in lung tumor tissues. In addition, the expressions of PCNA, Ki67, and Bcl-2 were reduced, but Bax and Caspase-3 were increased in treated rats, typically in those rats treated with the combination of anti-miR-22, BPI-2009H, and LY-231514. CONCLUSION: Inhibition of miR-22 could enhance the efficacy of icotinib combined with pemetrexed in rats with NSCLC, providing a new perspective for NSCLC therapy.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA