Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Cell Chem Biol ; 27(9): 1124-1129, 2020 09 17.
Artículo en Inglés | MEDLINE | ID: mdl-32707038

RESUMEN

Chemogenetic libraries, collections of well-defined chemical probes, provide tremendous value to biomedical research but require substantial effort to ensure diversity as well as quality of the contents. We have assembled a chemogenetic library by data mining and crowdsourcing institutional expertise. We are sharing our approach, lessons learned, and disclosing our current collection of 4,185 compounds with their primary annotated gene targets (https://github.com/Novartis/MoaBox). This physical collection is regularly updated and used broadly both within Novartis and in collaboration with external partners.


Asunto(s)
Sondas Moleculares/química , Bibliotecas de Moléculas Pequeñas/química , Bioensayo , Bases de Datos de Compuestos Químicos , Descubrimiento de Drogas , Humanos , Aprendizaje Automático , Sondas Moleculares/metabolismo , Bibliotecas de Moléculas Pequeñas/metabolismo
2.
J Biomol Screen ; 21(10): 1075-1089, 2016 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-27601436

RESUMEN

One of the central questions in the characterization of enzyme inhibitors is determining the mode of inhibition (MOI). Classically, this is done with a number of low-throughput methods in which inhibition models are fitted to the data. The ability to rapidly characterize the MOI for inhibitors arising from high-throughput screening in which hundreds to thousands of primary inhibitors may need to be characterized would greatly help in lead selection efforts. Here we describe a novel method for determining the MOI of a compound without the need for curve fitting of the enzyme inhibition data. We provide experimental data to demonstrate the utility of this new high-throughput MOI classification method based on nonparametric analysis of the activity derived from a small matrix of substrate and inhibitor concentrations (e.g., from a 4S × 4I matrix). Lists of inhibitors from four different enzyme assays are studied, and the results are compared with the previously described IC50-shift method for MOI classification. The MOI results from this method are in good agreement with the known MOI and compare favorably with those from the IC50-shift method. In addition, we discuss some advantages and limitations of the method and provide recommendations for utilization of this MOI classification method.


Asunto(s)
Inhibidores Enzimáticos/química , Enzimas/química , Ensayos Analíticos de Alto Rendimiento/métodos , Evaluación Preclínica de Medicamentos/métodos , Inhibidores Enzimáticos/clasificación , Humanos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...