1.
Clin Radiol ; 68(12): 1247-53, 2013 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-23973163

RESUMEN

AIM: To evaluate the influence of locally active Crohn's disease on systemic small-bowel motility in patients with chronic Crohn's disease compared to healthy individuals. MATERIAL AND METHODS: Fifteen healthy individuals (11 men, four women; mean age 37 years) and 20 patients with histopathologically proven active (n = 15; 10 women, 5 men; mean age 45 years) or chronic (n = 5; four women, one man; mean age 48 years) Crohn's disease were included in this institutional review board-approved, retrospective study. Magnetic resonance imaging (MRI; 1.5 T) was performed after standardized preparation. Two-dimensional (2D) cine sequences for motility acquisition were performed in apnoea (27 s). Motility assessment was performed using dedicated software in three randomly chosen areas of the small-bowel outside known Crohn's disease-affected hotspots. The main quantitative characteristics (frequency, amplitude, occlusion rate) were compared using Student's t-test and one-way analysis of variance (ANOVA). RESULTS: Three randomly chosen segments were analysed in each participant. Patients with active Crohn's disease had significantly (p < 0.05) reduced contraction frequencies (active Crohn's disease: 2.86/min; chronic: 4.14/min; healthy: 4.53/min) and luminal occlusion rates (active: 0.43; chronic: 0.70; healthy: 0.73) compared to healthy individuals and patients with chronic Crohn's disease. Contraction amplitudes were significantly reduced during active Crohn's disease (6.71 mm) compared to healthy participants (10.14 mm), but this only reached borderline significance in comparison to chronic Crohn's disease (8.87 mm). Mean bowel lumen diameter was significantly (p = 0.04) higher in patients with active Crohn's disease (16.91 mm) compared to healthy participants (14.79 mm) but not in comparison to patients with chronic Crohn's disease (13.68). CONCLUSION: The findings of the present study suggest that local inflammatory activity of small-bowel segments in patients with active Crohn's disease alters small-bowel motility in distant, non-affected segments. The motility patterns revealed reduced contraction-wave frequencies, amplitudes, and decreased luminal occlusion rates. Thus evaluation of these characteristics potentially helps to differentiate between chronic and active Crohn's disease.


Asunto(s)
Enfermedad de Crohn/patología , Motilidad Gastrointestinal , Imagen por Resonancia Cinemagnética , Adulto , Anciano , Anciano de 80 o más Años , Estudios de Casos y Controles , Enfermedad de Crohn/diagnóstico , Enfermedad de Crohn/fisiopatología , Femenino , Humanos , Íleon/patología , Íleon/fisiopatología , Intestino Delgado/patología , Intestino Delgado/fisiopatología , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Adulto Joven
2.
Acta Radiol ; 46(7): 729-33, 2005 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-16372693

RESUMEN

PURPOSE: To evaluate the three standard orthogonal imaging planes and a paracoronal imaging plane for anterior cruciate ligament (ACL) tears. MATERIAL AND METHODS: Ninety patients (91 knees; 29 F and 61 M) aged between 15 and 84 years (mean 36.9 +/- 16.4 years) underwent magnetic resonance imaging (MRI) of the knee prior to arthroscopy. At surgery, 32 knees had an intact ACL, 4 a partial tear, and 55 a complete ACL tear. In all patients, axial, sagittal, coronal, and paracoronal T2-weighted turbo-SE images were acquired. The ACL was classified as intact, partially, or completely torn. Partial and complete tears were combined for statistical evaluation. RESULTS: Partial ACL tears (four cases) were not correctly diagnosed at MRI except in one knee by one observer on coronal images. Sensitivity in detecting ACL tears was 95%/63% (reader1/reader2) in the axial, 93%/95% in the sagittal, 93%/86% in the coronal, and 100%/93% in the paracoronal plane. Specificity was 75%/81% in the axial, 72%/81% in the sagittal, 78%/94% in the coronal, and 78%/88% in the paracoronal plane. CONCLUSION: ACL tears can be diagnosed accurately with each of the standard orthogonal planes. Based on reader confidence and interobserver agreement paracoronal images may be useful in equivocal cases.


Asunto(s)
Lesiones del Ligamento Cruzado Anterior , Imagen por Resonancia Magnética/métodos , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad
3.
Lancet ; 358(9286): 987-8, 2001 Sep 22.
Artículo en Inglés | MEDLINE | ID: mdl-11583757

RESUMEN

Magnetic resonance enteroclysis is a promising technique that allows assessment of the small bowel but needs invasive nasoduodenal intubation. We propose a non-invasive distension method for magnetic-resonance imaging (MRI) in which ispaghula, dissolved in an aqueous solution with meglumine gadoterate taken orally over 4 h forms a viscous hydrogel within the intestinal lumen. MRI results from ten volunteers showed good luminal distension, constant signal homogeneity, optimum demarcation of the bowel content from surrounding tissues, and a low rate of artefacts. Our method permits non-invasive high quality MRI of the small bowel.


Asunto(s)
Catárticos/farmacología , Intestino Delgado/efectos de los fármacos , Imagen por Resonancia Magnética/métodos , Psyllium/farmacología , Adulto , Femenino , Humanos , Enfermedades Intestinales/diagnóstico , Masculino , Persona de Mediana Edad
4.
Br J Radiol ; 72(857): 448-51, 1999 May.
Artículo en Inglés | MEDLINE | ID: mdl-10505007

RESUMEN

Intravascular pressure measurements are considered useful for the monitoring and assessment of endovascular treatment effects in intracranial vascular malformations. Experimental data on the accuracy of these measurements are limited. A flow phantom with defined intraluminal pressures and pulsatility flow waveforms was used in this study. Microcatheters commercially available for neuroendovascular procedures (length 140-155 cm), with different outer (0.5-0.83 mm) and inner (0.3-0.53 mm) diameters, were introduced into the phantom in the direction of flow. In a static experiment, pressure values from 0 to 75 mmHg were applied, and in the dynamic part of the experiment mean pressure values from 25 to 65 mmHg, with a pulsatile amplitude from 70 to 170 mmHg were employed. In the static experiment, there was a linear relationship between the pressure values obtained through the microcatheters and the local transducer of the flow phantom. The pulsatile experiments showed increased damping of the pressure waveforms with decreasing inner diameter of the microcatheters. However, the mean pressure values remained accurate. This experimental study has shown that mean pressure values can be accurately measured through microcatheters from 0.3-0.5 mm inner diameter and more than 140 cm in length. In vivo pressure measurements during interventional procedures are therefore reproducible and can be used for monitoring of embolization effects in patients.


Asunto(s)
Cateterismo Periférico/normas , Velocidad del Flujo Sanguíneo , Humanos , Fantasmas de Imagen , Presión , Flujo Pulsátil , Sensibilidad y Especificidad
5.
Med Biol Eng Comput ; 36(6): 673-8, 1998 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-10367456

RESUMEN

The application of spin-echo magnetic resonance imaging sequences on non-invasive temperature imaging for temperature mapping of human limbs is investigated. In an in vitro experiment performed on a meat sample, the equilibrium magnetisation P and the spin-lattice relaxation time T1 are calculated from the values for the repetition time TR and the signal intensities obtained by a spin-echo sequence at different tissue temperatures as measured by a fibre-optic probe. T1 is linearly correlated to the tissue temperature, and P is linearly correlated to the reciprocal value of the absolute temperature. Both effects, taken together, lead to a non-linear dependency of the signal intensity on temperature. Therefore a TR leading to maximum temperature dependency of the signal intensity is calculated and used in the further experiments. In the in vivo experiments, the lower legs of two volunteers are cooled from outside. Images are acquired with a spin-echo sequence (1.5 T, TR = 1200 ms, TE = 10 ms). A rise in signal intensity in the muscle with falling skin temperature is observed, particularly in more peripheral muscle layers. This study shows that spin-echo sequences can be used to monitor temperature changes and temperature differences in living muscle tissue.


Asunto(s)
Temperatura Corporal , Imagen por Resonancia Magnética/métodos , Músculo Esquelético/fisiología , Animales , Bovinos , Femenino , Humanos , Pierna/fisiología , Masculino
6.
Circulation ; 96(12): 4286-97, 1997 Dec 16.
Artículo en Inglés | MEDLINE | ID: mdl-9416895

RESUMEN

BACKGROUND: Two-dimensional (2D) echocardiographic approaches based on geometric assumptions face the greatest limitations and inaccuracies in patients with left ventricular (LV) aneurysms. Three-dimensional (3D) echocardiographic techniques can potentially overcome these limitations; to date, however, although tested in experimental models of aneurysms, they have not been applied to a series of patients with such distortion. The purpose of this study was therefore to validate the clinical application of tomographic 3D echocardiography (3DE) by the routine transthoracic approach to determine LV chamber size and systolic function without geometric assumptions in patients with LV aneurysms. METHODS AND RESULTS: In 23 patients with chronic stable LV aneurysms, LV end-systolic and end-diastolic volumes (LVEDV, LVESV) and ejection fraction (LVEF) by tomographic 3DE were compared with results from 3D magnetic resonance tomography (3DMRT) as an independent reference as well as with the conventional techniques of single plane and biplane 2D echocardiography and biplane cineventriculography. Dynamic 3DE image data sets were obtained from a transthoracic apical view with the use of a rotating probe with acquisition gated to control for ECG and respiration (Echoscan, TomTec). Volumes were calculated from the 3D data sets by summating the volumes of multiple parallel disks. 3DE results correlated and agreed well with those by 3DMRT, with better correlation and agreement than provided by other techniques for LVEDV (3DE: r=.97, SEE=14.7 mL, SD of differences from 3DMRT=14.5 mL; other techniques: r=.84 to .93, SEE=30.7 to 41.6 mL [P<.001 versus 3DE by F test], SD of differences=31.5 to 40.7 mL [P<.001 versus 3DE by F test]). The same also pertained to LVESV (3DE: r=.97, SEE=12.4 mL, SD of differences=12.9 mL; other techniques: r=.81 to .90, SEE=24.7 to 37.2 mL [P<.001], SD of differences=27.6 to 36.8 mL [P<.005]) and LVEF (3DE: r=.74, SEE=5.6%, SD of differences=6.7%; other techniques: r=.14 to .59, SEE=9.5% to 10.1% [P<.01], SD of differences=9.5% to 12.6% [P<.05]). Compared with 3DMRT, 3DE was less time consuming and patient discomfort was less. CONCLUSIONS: Tomographic 3DE is an accurate noninvasive technique for calculating LV volumes and systolic function in patients with LV aneurysm. Unlike current 2D methods, tomographic 3DE requires no geometric assumptions that limit accuracy.


Asunto(s)
Ecocardiografía Tridimensional , Aneurisma Cardíaco/diagnóstico por imagen , Función Ventricular Izquierda/fisiología , Anciano , Ecocardiografía , Femenino , Aneurisma Cardíaco/diagnóstico , Humanos , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Películas Cinematográficas , Variaciones Dependientes del Observador , Sístole
7.
Minim Invasive Neurosurg ; 39(2): 33-7, 1996 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-8811653

RESUMEN

For neuronavigation in neuroendoscopy conventional navigation systems cannot exclude tissue movements caused by loss of cerebrospinal fluid (CSF). Open MRI can serve as a real-time navigation system if special conditions of endoscopic instruments and equipment are followed. We adapted an endoscopic system to the MRI and installed a miniaturized laser guidance system to project the central transaxial and coronal planes onto the phantom. A human cadaveric model was examined with a flexible microendoscope marked with a titanium wire inside the open magnet. The procedures were guided by gradient echo sequences refreshing the image every 4.5 seconds to control position of the endoscope. Endoscopic and corresponding MRI-findings are presented. Results and technical conditions are discussed.


Asunto(s)
Encéfalo/anatomía & histología , Endoscopía/métodos , Imagen por Resonancia Magnética , Artefactos , Endoscopios , Diseño de Equipo , Estudios de Factibilidad , Humanos , Imagen por Resonancia Magnética/instrumentación , Grabación en Video
8.
Neurol Res ; 18(3): 256-8, 1996 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-8837064

RESUMEN

The aim of the investigation was the technical realization and approval of a new method for insertion and detachment of platinum alloy microcoils and other vascular implants via standard microcatheters. Flexible lightconducting fibers, 105 microns in diameter were connected to platinum alloy microcoils. It was examined whether an insertion wire, a lightconducting fiber and a platinum alloy microcoil could be advanced through a Tracker-18 (Target) microcatheter. The detachment of the attached coil from the lightconducting fiber was investigated. Platinum alloy microcoils can be attached to available lightconducting fibers in a reliable and reproduceable manner. Together with the fiber they can be advanced via a Tracker-18 microcatheter. Only extremely tortuous vessels may increase the friction to critical values. A Ho-YAG laser source was used. This allowed the instantaneous detachment of microcoils from laser fibers. In contrast to electrolytical detachment, no foreign substances are released to the blood stream. The detachment does not require waiting time and does not activate thrombus formation. Due to specific technical features, injuries of the vessel wall are avoided. After further miniaturization and adaption of the lightconducting fibers to the required characteristics, laster detachment may have the potential to replace current methods such as electrolytical and mechanical coil detachment.


Asunto(s)
Rayos Láser , Neurocirugia/métodos , Platino (Metal)
9.
Endod Dent Traumatol ; 11(6): 297-300, 1995 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-8617167

RESUMEN

A case of a transdental fixation planned on the basis of ultrafast computed tomography is reported. This method allows to gain an insight in the osseous structures required for the operative procedure. Ultrafast computed tomography is superior to the conventional radiographs in obtaining accurate information about the vertical bone supply and the extension of the facial osseous sinus wall. A set of axial CT-images with an extension of 3 mm was acquired in the region of the alveolar bone. By means of frontal reconstructions and data processing methods the thickness of the bone layer in transverse direction was accurately determined. The calculated bone thickness allowed to anchor a transdental self-tapping titanium screw.


Asunto(s)
Pérdida de Hueso Alveolar/diagnóstico por imagen , Implantación Endodóntica Endoósea , Periodontitis Periapical/cirugía , Radiografía Dental/métodos , Tomografía Computarizada por Rayos X/métodos , Adulto , Proceso Alveolar/diagnóstico por imagen , Femenino , Humanos , Seno Maxilar/diagnóstico por imagen , Osteólisis/etiología , Planificación de Atención al Paciente , Periodontitis Periapical/etiología , Técnica de Perno Muñón/efectos adversos , Raíz del Diente/lesiones
10.
Geburtshilfe Frauenheilkd ; 54(4): 204-12, 1994 Apr.
Artículo en Alemán | MEDLINE | ID: mdl-8013855

RESUMEN

In 50 patients with suspected or proven cephalo-pelvine disproportion pelvimetry was performed with MR-tomography using a gradient-echo-sequence (FLASH 2D) before or after labour. Results were compared with measurements using digital radiography. In principle, both methods are exchangeable. The sagittal pelvic in- and outlet bispinous diameters are well reproducible. On the other hand, the transverse pelvic inlet and the distance between the ischiatic tubera are not so reliably reproduced. The accuracy of measurement does not depend on individual pelvic distances. Critical statistical analysis demonstrates, that in the worst case differences between the two methods might become unacceptable. Our results indicate two major reasons: 1. there are interobserver problems which cannot be neglected, and 2. the anatomical definition of referential landmarks for the measurements is unsafe. In 10 volunteers, a comparison was made between a T1-weighted spin-echo sequence (SE), a fast gradient echo sequence (FLASH-2D) and an ultrafast gradient echo technique (Turbo-FLASH). For the examination techniques presented here, the high-frequency exposure load or specific absorption rate (SAR loc and SAR total) is below the values permitted by the German Federal Health Bureau (Bundesgesundheitsamt). Whereas the exposure load in case of spin-echo takes (SE) is 22fold higher than with the gradient echo technique (GHE), the load values of ultra-fast GE (usGE) are only about 16% of the 2D-FLASH sequence or about 0.007% of SE. The difference in image quality does not affect the accuracy of measurement.


Asunto(s)
Distocia/diagnóstico , Imagen por Resonancia Magnética/métodos , Pelvimetría/métodos , Intensificación de Imagen Radiográfica/métodos , Adolescente , Adulto , Femenino , Humanos , Recién Nacido , Embarazo , Dosis de Radiación
11.
Radiologe ; 34(4): 212-20, 1994 Apr.
Artículo en Alemán | MEDLINE | ID: mdl-7914374

RESUMEN

2D-phase-contrast mapping is a MR method that allows for quantitative measurements of blood flow velocity in intracranial vessels. Using a modified FISP-Sequence with a 1.5 T MR scanner, flow studies were carried out on a phantom. Two matrix sizes (256 x 256 vs. 256 x 512) were compared. In 20 healthy volunteers blood flow velocity and profile of the basal (BA), middle cerebral (MCA), and anterior cerebral artery (ACA) were compared with the corresponding findings of transcranial Doppler (TCD) sonography. 2DPK and TCD yielded equivalent velocity data and profiles of the BA. The blood flow velocity in the MCA determined by 2DPK was lower than the TCD values. Using a 256 x 512 matrix, the acquired data were in better accordance with the TCD findings. Due to significant noise measurements of the ACA and PCA were frequently degraded.


Asunto(s)
Encéfalo/irrigación sanguínea , Imagen por Resonancia Magnética/métodos , Arteria Basilar/fisiopatología , Velocidad del Flujo Sanguíneo/fisiología , Arterias Cerebrales/fisiopatología , Humanos , Modelos Anatómicos , Valores de Referencia , Ultrasonografía Doppler Transcraneal
12.
Radiology ; 190(1): 105-10, 1994 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-8259384

RESUMEN

PURPOSE: To determine the reliability of magnetic resonance (MR) angiography in depicting normal vascular anatomy and its usefulness in detecting vascular disease compared with those of digital subtraction angiography (DSA). MATERIALS AND METHODS: Sixty patients with symptoms referable to disease of the vertebrobasilar system were examined with MR angiography and DSA. RESULTS: In patients with normal DSA results, all vertebral arteries (VAs) and basilar arteries (BAs) were also visualized with MR angiography. MR angiography demonstrated 117 of 120 superior cerebellar arteries and 80 of 90 posterior inferior cerebellar arteries but only 30 of 58 anterior inferior cerebellar arteries. MR angiography demonstrated disease of the VAs and BAs with 100% sensitivity. Stenoses were differentiated from occlusions in all cases. However, the degree of stenosis was overestimated in 63% of patients. In six patients with occlusive disease, collateral flow was correctly analyzed with selective saturation. CONCLUSION: Despite its limitations, MR angiography is a clinically important noninvasive technique for screening patients for macroangiopathy of the posterior arterial supply to the brain.


Asunto(s)
Arteria Basilar/patología , Imagen por Resonancia Magnética , Arteria Vertebral/patología , Insuficiencia Vertebrobasilar/diagnóstico , Adolescente , Adulto , Anciano , Angiografía de Substracción Digital , Arteria Basilar/anatomía & histología , Arteria Basilar/diagnóstico por imagen , Angiografía Cerebral , Humanos , Persona de Mediana Edad , Sensibilidad y Especificidad , Arteria Vertebral/anatomía & histología , Arteria Vertebral/diagnóstico por imagen , Insuficiencia Vertebrobasilar/diagnóstico por imagen
13.
Stroke ; 24(9): 1310-5, 1993 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-8362423

RESUMEN

BACKGROUND AND PURPOSE: Magnetic resonance angiography is a new, noninvasive technique whose diagnostic value in vertebrobasilar artery disease has not yet been determined. METHODS: Forty-one patients with acute cerebellar and/or brain-stem ischemia were examined by routine magnetic resonance imaging, extracranial and transcranial Doppler ultrasound, and selective intra-arterial arteriography. Results were correlated with magnetic resonance angiography. Magnetic resonance angiography was accomplished using a three-dimensional time-of-flight gradient-echo technique. RESULTS: Magnetic resonance angiography correctly identified all occlusions, stenoses, and an aneurysm within the distal vertebrobasilar system as revealed by conventional intra-arterial arteriography but missed the diagnosis of vertebral artery dissection in one case. This results in a sensitivity of magnetic resonance angiography of 97% and a specificity of 98.9%. However, the degree of stenoses was difficult to evaluate by magnetic resonance angiography. At least for severe obstructive lesions, this drawback can be eliminated by application of presaturation pulses, which allow the analysis of flow direction and collateral blood flow. Doppler ultrasound studies add useful hemodynamic information for less severe degrees of stenoses. CONCLUSIONS: The combined use of magnetic resonance angiography and Doppler ultrasound findings may replace the invasive intra-arterial arteriography examination in many patients with suspected macroangiopathy of the vertebrobasilar arteries.


Asunto(s)
Insuficiencia Vertebrobasilar/diagnóstico por imagen , Adulto , Anciano , Femenino , Humanos , Imagen por Resonancia Magnética , Masculino , Métodos , Persona de Mediana Edad , Radiografía , Ultrasonografía , Insuficiencia Vertebrobasilar/diagnóstico
14.
Biomed Tech (Berl) ; 38(4): 81-6, 1993 Apr.
Artículo en Alemán | MEDLINE | ID: mdl-8507807

RESUMEN

Invasive measurement of internal loads is either not possible at all, or is extremely difficult. A non-invasive method for use in the clinical setting might be the computer-aided simulation of a mechanical model. All the geometrical data required can be obtained, at a level of accuracy not previously attainable, with the aid of magnetic resonance imaging.


Asunto(s)
Simulación por Computador , Procesamiento de Imagen Asistido por Computador/instrumentación , Articulaciones/fisiología , Locomoción/fisiología , Imagen por Resonancia Magnética/instrumentación , Contracción Muscular/fisiología , Soporte de Peso/fisiología , Fenómenos Biomecánicos , Humanos , Masculino , Persona de Mediana Edad , Modelos Anatómicos , Valores de Referencia
16.
Geburtshilfe Frauenheilkd ; 53(1): 35-41, 1993 Jan.
Artículo en Alemán | MEDLINE | ID: mdl-8440456

RESUMEN

Imaging procedures suitable for diagnosis of cephalopelvic disproportion, such as radiological pelvimetry, computer- or magnetic resonance imaging (MRI) fail to reflect the dynamics of delivery, including deformations of the birth channel as well as of foetal structures. In order to validate findings of imaging procedures in this respect, a method has been developed to perform dynamic, biomechanical postprocessing of the static information obtained from MRI. Using a specially developed software MRI pixel, matrices of the maternal pelvis and the foetal head were colour-coded and--according to the principle of equal density--line data were created. After sectional attribution of the resulting polygones, a three-dimensional mesh of so called Finite Elements (FE) was created, which can then be used for deformation analysis. The foetal head was then moved through the birth channel by means of computed simulation. This allows not only ongoing deformations to be visualised, but also resulting forces can be calculated at any time of the delivery process for any point of the anatomical model. Furthermore, these calculations can be performed assuming various conditions such as different cephalopelvic dimensions and various labour forces or biomechanical properties of the tissues involved. This paper aims at presenting the method and its mode of working by means of one example of a computed birth simulation.


Asunto(s)
Traumatismos del Nacimiento/prevención & control , Simulación por Computador , Distocia/diagnóstico , Procesamiento de Imagen Asistido por Computador/instrumentación , Imagen por Resonancia Magnética/instrumentación , Pelvimetría/instrumentación , Programas Informáticos , Adulto , Fenómenos Biomecánicos , Hemorragia Cerebral/prevención & control , Femenino , Humanos , Recién Nacido , Modelos Anatómicos , Embarazo
17.
Rofo ; 157(4): 333-7, 1992 Oct.
Artículo en Alemán | MEDLINE | ID: mdl-1391834

RESUMEN

A method is presented that enables the use of (static) informations from magnetic resonance imaging (MRI) for (dynamic) biomechanical analysis. Using a specially developed software MRI pixel matrices are colour-coded and--according to the principle of same density--line data are created. After sectional attribution of the resulting polygons a three-dimensional mesh of so-called finite elements is created which can then be used in deformation analysis. This method is exemplified by a project dealing with the simulation of birth mechanics, which is finally aimed at validating the results from radiologic pelvimetry. First analyses show that even under foetal head moulding conditions, being considered as normal, such sensitive structures as the cerebellum, brain stem as well as the ventricles with the plexus chorioidei are to be found within the maximum isobars within a range of 104-140 N(10.6-14.3 kp).


Asunto(s)
Simulación por Computador , Trabajo de Parto , Imagen por Resonancia Magnética/métodos , Modelos Biológicos , Adulto , Fenómenos Biomecánicos , Color , Computadores , Femenino , Humanos , Presentación en Trabajo de Parto , Imagen por Resonancia Magnética/instrumentación , Embarazo , Programas Informáticos
18.
Am J Emerg Med ; 10(5): 418-20, 1992 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-1642704

RESUMEN

The authors conducted a prospective study to assess the performance of paramedics with prior adult endotracheal intubation experience in pediatric intubation in the operating room of a teaching hospital. Nineteen paramedic students were observed attempting endotracheal intubation on a total of 57 anesthetized pediatric patients undergoing scheduled surgical procedures. The average age of patients was 5.1 years (range, 6 months to 15.2 years). Average duration of intubation attempts was 22.7 +/- 10.7 seconds, with a success rate on first attempt of 74%. Only minor complications occurred, and were limited to intubation attempts of greater than 45 seconds duration in four cases (6%), and patient oxygen saturation less than 90% in one case (2%). The study suggests that paramedics may be successfully incorporated into a hospital's clinical training program, and can receive closely supervised experience in pediatric endotracheal intubation without compromising patient care. Such training may increase the willingness of paramedics to attempt emergent prehospital endotracheal intubation of children, as well as increase their success with this potentially life-saving procedure.


Asunto(s)
Auxiliares de Urgencia/educación , Capacitación en Servicio/métodos , Intubación Intratraqueal , Adolescente , Adulto , Niño , Preescolar , Hospitales Pediátricos , Humanos , Lactante , Quirófanos , Oxígeno/sangre , Estudios Prospectivos , Factores de Tiempo , Washingtón
19.
J Neurol ; 239(7): 404-6, 1992 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-1403024

RESUMEN

The history of a 67-year-old woman with histologically proven Creutzfeldt-Jakob disease (CJD) is presented. Before typical clinical and neurophysiological signs of CJD developed, magnetic resonance imaging (MRI) showed slightly enhanced signal intensity of the caudate nuclei and putamina in T2-weighted and proton density images, corresponding to spongiform degeneration in neuropathological examination. Five weeks later characteristical progressive cortical atrophy was demonstrated by follow-up MRI.


Asunto(s)
Síndrome de Creutzfeldt-Jakob/diagnóstico , Imagen por Resonancia Magnética , Anciano , Atrofia , Núcleo Caudado/patología , Femenino , Estudios de Seguimiento , Humanos , Putamen/patología
20.
Rofo ; 156(3): 212-7, 1992 Mar.
Artículo en Alemán | MEDLINE | ID: mdl-1550915

RESUMEN

Paramagnetic contrast agents produce local magnetic field inhomogeneity when they pass through the cerebrovascular system. This effect can be monitored with T2*-weighted gradient echo images, which show transient signal loss, while a bolus of GdDTPA is passing through the brain tissue. This signal loss is correlated to the local cerebral tissue perfusion and the local cerebral blood volume. In a prospective study 10 volunteers and 14 patients with cerebral infarcts and brain tumours were examined. After bolus application of GdDTPA a dynamic series of rapid T2*-weighted gradient echo images were recorded, and the local dynamics of contrast flow in brain tissue was examined. From the series of images, local changes in signal intensity were calculated pixel by pixel and presented as parameter images. By this method, infarcted areas and brain tumours can be distinguished from normal tissue by their contrast flow dynamics. The abnormal contrast dynamics depend on changes in local tissue perfusion and alterations in local blood volume. The separation of the influence of both parameters however is still an unsolved problem.


Asunto(s)
Encéfalo/patología , Circulación Cerebrovascular , Medios de Contraste/administración & dosificación , Imagen por Resonancia Magnética/métodos , Adolescente , Adulto , Anciano , Neoplasias Encefálicas/diagnóstico , Neoplasias Encefálicas/epidemiología , Neoplasias Encefálicas/secundario , Infarto Cerebral/diagnóstico , Infarto Cerebral/epidemiología , Niño , Gadolinio/administración & dosificación , Gadolinio DTPA , Humanos , Inyecciones Intravenosas , Imagen por Resonancia Magnética/estadística & datos numéricos , Persona de Mediana Edad , Compuestos Organometálicos/administración & dosificación , Ácido Pentético/administración & dosificación , Estudios Prospectivos , Factores de Tiempo