Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Resuscitation ; 81(4): 463-71, 2010 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-20122781

RESUMEN

INTRODUCTION: High-fidelity medical simulation of sudden cardiac arrest (SCA) presents an opportunity for systematic probing of in-hospital resuscitation systems. Investigators developed and implemented the SimCode program to evaluate simulation's ability to generate meaningful data for system safety analysis and determine concordance of observed results with institutional quality data. METHODS: Resuscitation response performance data were collected during in situ SCA simulations on hospital medical floors. SimCode dataset was compared with chart review-based dataset of actual (live) in-hospital resuscitation system performance for SCA events of similar acuity and complexity. RESULTS: 135 hospital personnel participated in nine SimCode resuscitations between 2006 and 2008. Resuscitation teams arrived at 2.5+/-1.3 min (mean+/-SD) after resuscitation initiation, started bag-valve-mask ventilation by 2.8+/-0.5 min, and completed endotracheal intubations at 11.3+/-4.0 min. CPR was performed within 3.1+/-2.3 min; arrhythmia recognition occurred by 4.9+/-2.1 min, defibrillation at 6.8+/-2.4 min. Chart review data for 168 live in-hospital SCA events during a contemporaneous period were extracted from institutional database. CPR and defibrillation occurred later during SimCodes than reported by chart review, i.e., live: 0.9+/-2.3 min (p<0.01) and 2.1+/-4.1 min (p<0.01), respectively. Chart review noted fewer problems with CPR performance (simulated: 43% proper CPR vs. live: 98%, p<0.01). Potential causes of discrepancies between resuscitation response datasets included sample size and data limitations, simulation fidelity, unmatched SCA scenario pools, and dissimilar determination of SCA response performance by complementary reviewing methodologies. CONCLUSION: On-site simulations successfully generated SCA response measurements for comparison with live resuscitation chart review data. Continued research may refine simulation's role in quality initiatives, clarify methodologic discrepancies and improve SCA response.


Asunto(s)
Paro Cardíaco/terapia , Resucitación/normas , Reanimación Cardiopulmonar , Cardioversión Eléctrica , Registros de Hospitales , Humanos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...