Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Eur J Nucl Med Mol Imaging ; 38(12): 2247-56, 2011 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-21881927

RESUMEN

PURPOSE: The aim was to compare late-time extrapolation of plasma clearance (CL) from Tikhonov adaptively regularized gamma variate fitting (Tk-GV) and from mono-exponential (E1) fitting. METHODS: Ten (51)Cr-ethylenediaminetetraacetic acid bolus IV studies in adults--8 with ascites--assessed for liver transplantation, with 12-16 plasma samples drawn from 5-min to 24-h, were fit with Tk-GV and E1 models and CL results were compared using Passing-Bablok fitting. RESULTS: The 24-h CL(Tk-GV) values ranged from 11.4 to 79.7 ml/min. Linear regression of 4- versus 24-h CL(Tk-GV) yielded no significant departure from a slope of 1, whereas the 4- versus 24-h CL(E1) slope, 1.56, was significantly increased. For CL(Tk-GV-24-h) versus CL(E1-24-h), there was a biased slope and intercept (0.85, 5.97 ml/min). Moreover, the quality of fitting of 24-h data was significantly better for Tk-GV than for E1, as follows. For 10 logarithm of concentration curves, higher r values were obtained for each Tk-GV fit (median 0.998) than for its corresponding E1 fit (median 0.965), with p < 0.0001 (paired t-test of z-statistics from Fisher r-z transformations). The E1 fit quality degraded with increasing V/W [volume of distribution (l) per kg body weight, p = 0.003]. However, Tk-GV fit quality versus V/W was uncorrelated (p = 0.8). CONCLUSION: CL(E1) values were dependent on sample time and the quality of fit was poor and degraded with increasing ascites, consistent with current opinion that CL(E1) is contraindicated in ascitic patients. CL(Tk-GV) was relatively more accurate and the good quality of fit was unaffected by ascites. CL(Tk-GV) was the preferred method for the accurate calculation of CL and was useful despite liver failure and ascites.


Asunto(s)
Ascitis/sangre , Ascitis/diagnóstico , Diagnóstico por Computador/métodos , Ácido Edético/farmacocinética , Cirrosis Hepática/diagnóstico , Pruebas de Función Hepática/métodos , Técnica de Dilución de Radioisótopos , Adulto , Anciano , Análisis de Varianza , Ascitis/etiología , Simulación por Computador , Femenino , Humanos , Cirrosis Hepática/complicaciones , Masculino , Tasa de Depuración Metabólica , Persona de Mediana Edad , Modelos Biológicos , Radiofármacos/farmacocinética , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...