J Magn Reson Imaging ; 25(3): 548-56, 2007 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-17279503

RESUMEN

PURPOSE: To integrate a high intensity focused ultrasound (HIFU) transducer with an MR receiver coil for endocavitary MR-guided thermal ablation of localized pelvic lesions. MATERIALS AND METHODS: A hollow semicylindrical probe (diameter 3.2 cm) with a rectangular upper surface (7.2 cm x 3.2 cm) was designed to house a HIFU transducer and enable acoustic contact with an intraluminal wall. The probe was distally rounded to ease endocavitary insertion and was proximally tapered to a 1.5-cm diameter cylindrical handle through which the irrigation tubes (for transducer cooling) and electrical connections were passed. MR compatibility of piezoceramic and piezocomposite transducers was assessed using gradient-echo (GRE) sequences. The radiofrequency (RF) tuning of identical 6.5 cm x 2.5 cm rectangular receiver coils on the upper surface of the probe was adjusted to compensate for the presence of the conductive components of the HIFU transducers. A T1-weighted (T1-W) sliding window dual-echo GRE sequence monitored phase changes in the focal zone of each transducer. High-intensity (2400 W/cm(-2)), short duration (<1.5 seconds) exposures produced subtherapeutic temperature rises. RESULTS: For T1-W images, signal-to-noise ratio (SNR) improved by 40% as a result of quartering the conductive surface of the piezoceramic transducer. A piezocomposite transducer showed a further 28% improvement. SNRs for an endocavitary coil in the focal plane of the HIFU trans-ducer (4 cm from its face) were three times greater than from a phased body array coil. Local shimming improved uniformity of phase images. Phase changes were detected at subtherapeutic exposures. CONCLUSION: We combined a HIFU transducer with an MR receiver coil in an endocavitary probe. SNRs were improved by quartering the conductive surface of the piezoceramic. Further improvement was achieved with a piezocomposite transducer. A phase change was seen on MR images during both subtherapeutic and therapeutic HIFU exposures.


Asunto(s)
Ablación por Catéter/instrumentación , Hígado , Imagen por Resonancia Magnética/instrumentación , Fantasmas de Imagen , Terapia por Ultrasonido/instrumentación , Animales , Artefactos , Calibración , Ablación por Catéter/normas , Bovinos , Diseño de Equipo/métodos , Calor , Aumento de la Imagen/métodos , Imagen por Resonancia Magnética/métodos , Temperatura , Transductores , Terapia por Ultrasonido/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA