Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 64
Filtrar
1.
Materials (Basel) ; 17(3)2024 Jan 31.
Artículo en Inglés | MEDLINE | ID: mdl-38591559

RESUMEN

This study aims to examine the play between various archwires and bracket systems, exploring potential variations in angle values for specific torque and torque values for a given angle along different bracket systems. Therefore, seven brackets systems were evaluated in conjunction with different stainless steel archwires of varying dimensions (0.016″ × 0.022″, 0.018″ × 0.025″, and 0.019″ × 0.025″). Biomechanical behavior during torque development and transmission was assessed using a six-component force/torque sensor. Torque angles (5-45°) were specified with subsequent torque measurement, and the sequence was reversed by setting the torque (5-30 Nmm) and measuring the angle. A reference measurement with 0 Nmm torque served to evaluate bracket slot play. Bracket play (0 Nmm) during palatal load ranged between 20.06° and 32.50° for 0.016″ × 0.022″ wire, 12.83° and 21.11° for 0.018″ × 0.025″ wire, and 8.39° and 18.73° for 0.019″ × 0.025″ wire. The BioQuick® bracket exhibited the highest play, while Wave SL® and Damon® Q brackets demonstrated the lowest play (p < 0.001). Significant differences (p < 0.001) between the brackets were observed in the torque angles required to achieve torques of 5-20 Nmm. In summary, each bracket system has a different torque transmission, which is of great clinical importance in order to achieve correct torque transmission and avoid complications such as root resorption.

2.
J Orofac Orthop ; 2024 Feb 27.
Artículo en Inglés | MEDLINE | ID: mdl-38411719

RESUMEN

PURPOSE: The aim was to investigate the influence of three different three-dimensional (3D)-printed bonding tray designs and professional experience on accuracy of indirect bracket placement. METHODS: Virtual bracket placement was performed on a scanned dental model using OnyxCeph software (Image Instruments, Chemnitz, Germany). Three different designs for indirect bonding trays (open, semi-open, and closed design) were created and produced using a 3D printer. To analyze the influence of professional experience, one of the three tray designs was produced twice. In this case, bracket placement was performed by an inexperienced dentist. Bracket positions were scanned after the indirect bonding procedure. Linear and angular transfer errors were measured. Significant differences between the target and actual situation were analyzed using the Kruskal-Wallis and χ2 test. RESULTS: All bonding tray designs resulted in comparable results. The results of the unexperienced dentist showed significantly higher deviations than those for the experienced orthodontist in the torque direction. However, the mean values were comparable. The open tray design exceeded the clinically acceptable limits of 0.25 mm and 1° more often. The inexperienced dentist exceeded these limits significantly more often than the experienced orthodontist in the vertical and torque direction. The immediate bracket loss rate showed no significant differences between the different tray designs. Significantly more bracket losses were observed for the inexperienced dentist during the procedure compared to the experienced orthodontist. CONCLUSIONS: The bonding tray design and professional experience had an influence on the exceedance of clinically relevant limits of positioning accuracy and on the bracket loss rate.

3.
Bioengineering (Basel) ; 11(2)2024 Feb 02.
Artículo en Inglés | MEDLINE | ID: mdl-38391639

RESUMEN

En-bloc retraction is a common procedure in orthodontic therapy. The application of palatal root torque moments is required to control incisor inclination during retraction, yet studies comparing forces and moments with respect to different mechanics are lacking. This study aimed to investigate the forces and moments during orthodontic en-bloc retraction using a robotic biomechanical simulation system, comparing two distinct approaches: (I) compound technique [stainless steel (SS) combined with nickel-titanium (NiTi)] using industrially pretorqued retraction-torque-archwires (RTA) in combination with NiTi closed coil springs; (II) conventional sliding mechanics using SS archwires with manually applied anterior twist bends in combination with elastic chains. Two dimensions (0.017" × 0.025" and 0.018" × 0.025") and ten archwires per group were investigated using 0.022" slot self-ligating brackets. Kruskal-Wallis tests with a significance level of α = 0.05 were conducted. The biomechanical simulation showed that en-bloc retraction was characterized by a series of tipping and uprighting movements, differing significantly regarding the examined mechanics. Collateral forces and moments occurred in all groups. Notably, RTA exhibited fewer extrusive forces. The most bodily movement was achieved with the compound technique and the 0.018" × 0.025" RTA. Sliding mechanics exhibited maximum palatal root torque moments of more than 20 Nmm, exceeding recommended values.

4.
Materials (Basel) ; 17(2)2024 Jan 22.
Artículo en Inglés | MEDLINE | ID: mdl-38276472

RESUMEN

The aim of this study was to investigate the load deflection characteristics of Gummetal® wires in comparison to nickel-titanium (NiTi) wires. Four different NiTi wires and one Gummetal® archwire were analyzed in two dimensions (0.014″ (0.36 mm) and 0.016″ × 0.022″ (0.41 mm × 0.56 mm)) and in two different orientations (edgewise and ribbonwise) using three-point bending tests at T = 37 °C. Force-displacement curves were recorded and analyzed. The Gummetal® 0.014″ wires exhibited higher forces compared to the NiTi wires at 2.0 mm deflection. At 1.0 mm deflection, the opposite pattern was observed. For the 0.016″ × 0.022″ Gummetal® wires, the forces were within the force interval of the NiTi wires at 2.0 mm deflection. At a deflection of 1.0 mm, no residual force was measurable for the Gummetal® wires. All the NiTi wires investigated showed hysteresis and a superelastic plateau. However, the Gummetal® did not form a plateau, but hysteresis was present. An easier plastic deformability compared to the NiTi wires was observed for all the tested geometries.

5.
Bioengineering (Basel) ; 10(12)2023 Nov 25.
Artículo en Inglés | MEDLINE | ID: mdl-38135947

RESUMEN

The Robot Orthodontic Measurement and Simulation System (ROSS) is a novel biomechanical, dynamic, self-regulating setup for the simulation of tooth movement. The intrusion of the front teeth with forces greater than 0.5 N poses a risk for orthodontic-induced inflammatory root resorption (OIIRR). The aim was to investigate forces and moments during simulated tooth intrusion using ROSS. Five specimens of sixteen unmodified NiTi archwires and seven NiTi archwires with intrusion steps from different manufacturers (Forestadent, Ormco, Dentsply Sirona) with a 0.012″/0.014″/0.016″ wire dimension were tested. Overall, a higher wire dimension correlated with greater intrusive forces Fz (0.012″: 0.561-0.690 N; 0.014″: 0.996-1.321 N; 0.016″: 1.44-2.254 N) and protruding moments Mx (0.012″: -2.65 to -3.922 Nmm; 0.014″: -4.753 to -7.384 Nmm; 0.016″: -5.556 to -11.466 Nmm) during the simulated intrusion of a 1.6 mm-extruded upper incisor. However, the 'intrusion efficiency' parameter was greater for smaller wire dimensions. Modification with intrusion steps led to an overcompensation of the intrusion distance; however, it led to a severe increase in Fz and Mx, e.g., the Sentalloy 0.016″ medium (Dentsply Sirona) exerted 2.891 N and -19.437 Nmm. To reduce the risk for OIIRR, 0.014″ NiTi archwires can be applied for initial aligning (without vertical challenges), and intrusion steps for the vertical levelling of extruded teeth should be bent in the initial archwire, i.e., 0.012″ NiTi.

6.
Front Bioeng Biotechnol ; 11: 1256825, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37795174

RESUMEN

Introduction: This study aimed to identify and analyze in vitro studies investigating the biological effect of fluid-flow shear stress (FSS) on cells found in the periodontal ligament and bone tissue. Method: We followed the PRISMA guideline for systematic reviews. A PubMed search strategy was developed, studies were selected according to predefined eligibility criteria, and the risk of bias was assessed. Relevant data related to cell source, applied FSS, and locus-specific expression were extracted. Based on this evidence synthesis and, as an original part of this work, analysis of differential gene expression using over-representation and network-analysis was performed. Five relevant publicly available gene expression datasets were analyzed using gene set enrichment analysis (GSEA). Result: A total of 6,974 articles were identified. Titles and abstracts were screened, and 218 articles were selected for full-text assessment. Finally, 120 articles were included in this study. Sample size determination and statistical analysis related to methodological quality and the ethical statement item in reporting quality were most frequently identified as high risk of bias. The analyzed studies mostly used custom-made fluid-flow apparatuses (61.7%). FSS was most frequently applied for 0.5 h, 1 h, or 2 h, whereas FSS magnitudes ranged from 6 to 20 dyn/cm2 depending on cell type and flow profile. Fluid-flow frequencies of 1 Hz in human cells and 1 and 5 Hz in mouse cells were mostly applied. FSS upregulated genes/metabolites responsible for tissue formation (AKT1, alkaline phosphatase, BGLAP, BMP2, Ca2+, COL1A1, CTNNB1, GJA1, MAPK1/MAPK3, PDPN, RUNX2, SPP1, TNFRSF11B, VEGFA, WNT3A) and inflammation (nitric oxide, PGE-2, PGI-2, PTGS1, PTGS2). Protein-protein interaction networks were constructed and analyzed using over-representation analysis and GSEA to identify shared signaling pathways. Conclusion: To our knowledge, this is the first review giving a comprehensive overview and discussion of methodological technical details regarding fluid flow application in 2D cell culture in vitro experimental conditions. Therefore, it is not only providing valuable information about cellular molecular events and their quantitative and qualitative analysis, but also confirming the reproducibility of previously published results.

7.
Bioengineering (Basel) ; 10(9)2023 Sep 07.
Artículo en Inglés | MEDLINE | ID: mdl-37760157

RESUMEN

This study aimed to investigate the dynamic behavior of different torque archwires for fixed orthodontic treatment using an automated, force-controlled biomechanical simulation system. A novel biomechanical simulation system (HOSEA) was used to simulate dynamic tooth movements and measure torque expression of four different archwire groups: 0.017″ x 0.025″ torque segmented archwires (TSA) with 30° torque bending, 0.018″ x 0.025″ TSA with 45° torque bending, 0.017″ x 0.025″ stainless steel (SS) archwires with 30° torque bending and 0.018″ x 0.025″ SS with 30° torque bending (n = 10/group) used with 0.022″ self-ligating brackets. The Kruskal-Wallis test was used for statistical analysis (p < 0.050). The 0.018″ x 0.025″ SS archwires produced the highest initial rotational torque moment (My) of -9.835 Nmm. The reduction in rotational moment per degree (My/Ry) was significantly lower for TSA compared to SS archwires (p < 0.001). TSA 0.018″ x 0.025″ was the only group in which all archwires induced a min. 10° rotation in the simulation. Collateral forces and moments, especially Fx, Fz and Mx, occurred during torque application. The measured forces and moments were within a suitable range for the application of palatal root torque to incisors for the 0.018″ x 0.025″ archwires. The 0.018″ x 0.025″ TSA reliably achieved at least 10° incisal rotation without reactivation.

8.
J Mech Behav Biomed Mater ; 144: 105960, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37348170

RESUMEN

OBJECTIVES: Aim of this study was to determine the forces and moments during simulated initial orthodontic tooth movements using a novel biomechanical test setup. METHODS: The test setup consisted of an industrial precision robot with a force-torque sensor, a maxillary model and a control computer and software. Forces and moments acting on the corresponding experimental tooth during the motion simulations were dynamically measured for two 0.016" NiTi round archwires (Sentalloy Light/Sentalloy Medium). Intrusive (#1), rotational (#2) and angular (#3) tooth movements were simulated by a control program based on the principle of force control and executed by the robot. The results were statistically analysed using K-S-test and Mann-Whitney U test with a significance level of α = 5%. RESULTS: Sentalloy Medium archwires generated higher forces and moments than the Sentalloy Light archwires in all simulations. In simulation #1 the mean initial forces/moments reached 1.442 N/6.781 Nmm for the Light archwires and 1.637 N/9.609 Nmm for the Medium archwires. In movement #2 Light archwires generated mean initial forces/moments of 0.302 N/-8.271 Nmm whereas Medium archwires generated 0.432 N/-9.653 Nmm. Simulation #3 showed mean initial forces/moments of -0.122 N/8.477 Nmm from the Light archwires compared to -0.300 N/11.486 Nmm for the Medium archwires. SIGNIFICANCE: The measured forces and moments were suitable for initial orthodontic tooth movement in simulations #2 and #3, however inadequate in simulation #1. Reduced archwire dimensions (<0.016″) should be selected for initial leveling of vertical malocclusions.


Asunto(s)
Soportes Ortodóncicos , Robótica , Diseño de Aparato Ortodóncico , Técnicas de Movimiento Dental/métodos , Alambres para Ortodoncia
9.
BMC Oral Health ; 23(1): 274, 2023 05 10.
Artículo en Inglés | MEDLINE | ID: mdl-37165409

RESUMEN

BACKGROUND: One of the main uses of artificial intelligence in the field of orthodontics is automated cephalometric analysis. Aim of the present study was to evaluate whether developmental stages of a dentition, fixed orthodontic appliances or other dental appliances may affect detection of cephalometric landmarks. METHODS: For the purposes of this study a Convolutional Neural Network (CNN) for automated detection of cephalometric landmarks was developed. The model was trained on 430 cephalometric radiographs and its performance was then tested on 460 new radiographs. The accuracy of landmark detection in patients with permanent dentition was compared with that in patients with mixed dentition. Furthermore, the influence of fixed orthodontic appliances and orthodontic brackets and/or bands was investigated only in patients with permanent dentition. A t-test was performed to evaluate the mean radial errors (MREs) against the corresponding SDs for each landmark in the two categories, of which the significance was set at p < 0.05. RESULTS: The study showed significant differences in the recognition accuracy of the Ap-Inferior point and the Is-Superior point between patients with permanent dentition and mixed dentition, and no significant differences in the recognition process between patients without fixed orthodontic appliances and patients with orthodontic brackets and/or bands and other fixed orthodontic appliances. CONCLUSIONS: The results indicated that growth structures and developmental stages of a dentition had an impact on the performance of the customized CNN model by dental cephalometric landmarks. Fixed orthodontic appliances such as brackets, bands, and other fixed orthodontic appliances, had no significant effect on the performance of the CNN model.


Asunto(s)
Soportes Ortodóncicos , Ortodoncia , Humanos , Inteligencia Artificial , Redes Neurales de la Computación , Aparatos Ortodóncicos , Cefalometría/métodos
10.
Materials (Basel) ; 16(10)2023 May 11.
Artículo en Inglés | MEDLINE | ID: mdl-37241310

RESUMEN

The shape of superelastic Nickel-Titanium (NiTi) archwires can be adjusted with thermal treatments using devices such as the Memory-MakerTM (Forestadent), which potentially affects their mechanical properties. The effect of such treatments on these mechanical properties was simulated by means of a laboratory furnace. Fourteen commercially available NiTi wires (0.018″ × 0.025″) were selected from the manufacturers American Orthodontics, Dentaurum, Forestadent, GAC, Ormco, Rocky Mountain Orthodontics and 3M Unitek. Specimens were heat treated using different combinations of annealing duration (1/5/10 min) and annealing temperature (250-800 °C) and investigated using angle measurements and three-point bending tests. Complete shape adaptation was found at distinct annealing durations/temperatures for each wire ranging between ~650-750 °C (1 min), ~550-700 °C (5 min) and ~450-650 °C (10 min), followed by a loss of superelastic properties shortly afterwards at ~750 °C (1 min), ~600-650 °C (5 min) and ~550-600 °C (10 min). Wire-specific working ranges (complete shaping without loss of superelasticity) were defined and a numerical score (e.g., stable forces) was developed for the three-point bending test. Overall, the wires Titanol Superelastic (Forestadent), Tensic (Dentaurum), FLI CuNiTi27 (Rocky Mountain Orthodontics) and Nitinol Classic (3M Unitek) proved to be the most user-friendly. Thermal shape adjustment requires wire-specific working ranges to allow complete shape acceptance and high scores in bending test performance to ensure permanence of the superelastic behaviour.

11.
J Orofac Orthop ; 2023 Mar 06.
Artículo en Inglés | MEDLINE | ID: mdl-36877253

RESUMEN

PURPOSE: To investigate the skeletal and dental effects of a hybrid fixed functional appliance (FFA) used with different force magnitudes for class II subdivision 1 treatment. METHODS: Treatment records from 70 patients were evaluated: 35 patients were treated with a FFA with standard activation (SUS group) and 35 with a FFA with an additional force-generating spring (TSUS group). Two control groups were matched from the American Association of Orthodontists Foundation (AAOF) Craniofacial Growth Legacy Collection for comparison with the two treatment groups to determine skeletal and dental treatment effects. The cephalometric parameters at T0 (before treatment) and T1 (before debonding) were assessed using the Munich standard cephalometric analysis and by the sagittal occlusal analysis (SO) according to Pancherz. Data were analyzed statistically using SPSS. RESULTS: No statistically significant difference for any cephalometric parameter was observed between the SUS and TSUS groups concerning the measurements at T0 and T1. Both treatment groups exhibited an effective class II therapy mainly due to a significant reduction in SNA, and ANB and an increase in SNB. In contrast to the control group, as the result of treatment a skeletal class I was achieved. CONCLUSION: No significant statistical differences were observed between the patient group treated with the FFA with standard activation (SUS) and those treated with an additional spring (TSUS) regarding the cephalometric parameters investigated. Both variants were equally effective in treating class II division 1 malocclusions.

12.
Orthod Craniofac Res ; 26(3): 433-441, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-36504259

RESUMEN

OBJECTIVE: Tooth movement with elastic chains requires defined force magnitudes. This study assessed the force behaviour of different elastic chains at different configurations of gap width. METHODS: Self-ligating brackets of teeth 5 & 6 and 2 & 3 were bonded to two movable aluminium plates. The plates were positioned on a joint basis with varying distances of 0.5, 2.0, 4.0, 6.0, and 8.0 mm. Reset forces of open and closed chains from four different manufacturers were investigated in four different configurations. Configurations differed in either having an additional intermediate ring within the gap (#1, #3) and/or having intermediate rings between teeth adjacent to the gap (#1, #2), or by no intermediate rings (#4). Forces were measured with a universal testing machine. The results were statistically analysed using U-test, H-test and (if applicable) post-hoc tests with a significance level of .05. RESULTS: Configurations #1 and #3, and #2 and #4 formed homogenous subgroups (P < .001). Initial forces in configuration #4 were significantly higher than in configuration #3 (P = .029). Initial forces in closed chains were significantly higher than for open chains (P = .029). CONCLUSIONS: Intermediate chain rings adjacent to the gap are not required to modulate the force. In contrast, leaving a ring unapplied in the tooth gap can help modulate the force. Open thermoset chains with an additional ring within the gap (#3) seem to produce suitable initial forces for a gap closure of 4 mm. With a residual gap width of <2 mm, open thermoset chains and closed thermoset chains (#4) seem suitable.


Asunto(s)
Diente Canino , Soportes Ortodóncicos , Alambres para Ortodoncia , Técnicas de Movimiento Dental/métodos
13.
Life (Basel) ; 12(10)2022 Oct 13.
Artículo en Inglés | MEDLINE | ID: mdl-36295031

RESUMEN

BACKGROUND: The purpose of this study was to retrospectively evaluate and follow up a conservative treatment approach with functional orthodontic appliances for the management of mandibular condyle fractures in children and adolescent patients. METHODS: Between 2020 and 2022, the treatment records of patients with mandibular condyle fractures receiving a functional orthodontic treatment (FOT) were evaluated. In addition to the clinical and functional findings, magnetic resonance images of the mandibular condyles and surrounding structures were assessed. RESULTS: Out of 61 patients, 8 met the inclusion criteria. The follow-up examination records showed no functional limitations. In 75% of cases, mild midline deviations persisted (mean 1.1 mm) without significant alterations to the occlusal relationships. Magnetic resonance imaging (MRI) showed the remodeling of the condyles and the restitution of the ramus heights, even in dislocated and displaced fractures. In three cases, a partial displacement of the articular disc was observed at the follow-up. No differences in the remodeling patterns were noted depending on age, sex, or fracture location. CONCLUSIONS: A FOT led to favorable functional and morphologic outcomes, supporting the concept of a conservative functional approach in children and adolescent patients. Functional adjunctive therapy should be considered in the conservative treatment of mandibular condyle fractures in growing patients.

14.
Materials (Basel) ; 15(12)2022 Jun 15.
Artículo en Inglés | MEDLINE | ID: mdl-35744316

RESUMEN

The aim of this study was the investigation of polymeric coverings to adjust frictional forces between V-shaped wires and brackets, both made of superelastic NiTi. Adjustment of frictional forces is relevant for certain stages during orthodontic therapy. Coverings able to generate frictional forces when assembled to such brackets are additively manufactured. Six different internal widths of coverings were examined in three different environments: dry condition at room temperature (RT) or body temperature (BT), or artificial saliva (AS) at RT. The different coverings significantly affected the frictional forces for all media (p < 0.001). A correlation between internal width of the covering and resulting frictional forces was found. BT and dry environment showed the lowest friction forces for all samples. The highest force was found for two covering types at RT in AS, while the remaining four covering types showed the highest values in dry environment (p < 0.001). Friction could, therefore, be adjusted by variation of bracket covering clipped onto brackets, which is useful for orthodontic therapy. Coverings delivering higher friction provide dental anchorage, while coverings with lower friction can be used for tooth movement or purely esthetic reasons. It was shown that the variation of covering width may be used for adjustment of frictional forces.

15.
Materials (Basel) ; 15(11)2022 May 28.
Artículo en Inglés | MEDLINE | ID: mdl-35683151

RESUMEN

Background: The clinical outcome of aligner therapy is closely related to the precision of its setup, which can be manually or digitally fabricated. The aim of the study is to investigate the suitability of manual setups made for aligner therapy in terms of the precision of tooth movements. Methods: Six dental technicians were instructed to adjust each of eleven duplicate plaster casts of a patient models as follows: a 1 mm pure vestibular translation of tooth 11 and a 15° pure mesial rotation of tooth 23. The processed setup models were 3D scanned and matched with the reference model. The one-sample Wilcoxon signed-rank test (p < 0.05) was used for evaluation. Results: The overall precision of the translational movement covers a wide range of values from 0.25 to 2.26 mm (median: 1.09 mm). The target value for the rotation of tooth 23 was achieved with a median rotation of 9.76° in the apical-occlusal direction. Unwanted movements in the other planes also accompanied the rotation. Conclusions: A manual setup can only be fabricated with limited precision. Besides the very high variability between technicians, additional unwanted movements in other spatial planes occurred. Manually fabricated setups should not be favored for aligner therapy due to limited precision.

16.
J Clin Med ; 11(9)2022 May 04.
Artículo en Inglés | MEDLINE | ID: mdl-35566695

RESUMEN

PURPOSE: To investigate the bracket transfer accuracy of the indirect bonding technique (IDB). METHODS: Systematic search of the literature was conducted in PubMed MEDLINE, Web of Science, Embase, and Scopus through November 2021. SELECTION CRITERIA: In vivo and ex vivo studies investigating bracket transfer accuracy by comparing the planned and achieved bracket positions using the IDB technique were considered. Information concerning patients, samples, and applied methodology was collected. Measured mean transfer errors (MTE) for angular and linear directions were extracted. Risk of bias (RoB) in the studies was assessed using a tailored RoB tool. Meta-analysis of ex vivo studies was performed for overall linear and angular bracket transfer accuracy and for subgroup analyses by type of tray, tooth groups, jaw-related, side-related, and by assessment method. RESULTS: A total of 16 studies met the eligibility criteria for this systematic review. The overall linear mean transfer errors (MTE) in mesiodistal, vertical and buccolingual direction were 0.08 mm (95% CI 0.05; 0.10), 0.09 mm (0.06; 0.11), 0.14 mm (0.10; 0.17), respectively. The overall angular mean transfer errors (MTE) regarding angulation, rotation, torque were 1.13° (0.75; 1.52), 0.93° (0.49; 1.37), and 1.11° (0.68; 1.53), respectively. Silicone trays showed the highest accuracy, followed by vacuum-formed trays and 3D printed trays. Subgroup analyses between tooth groups, right and left sides, and upper and lower jaw showed minor differences. CONCLUSIONS AND IMPLICATIONS: The overall accuracy of the indirect bonding technique can be considered clinically acceptable. Future studies should address the validation of the accuracy assessment methods used.

17.
Dent Mater J ; 41(3): 402-413, 2022 May 31.
Artículo en Inglés | MEDLINE | ID: mdl-35370257

RESUMEN

The aim of the present work was measuring the effect of varying normal forces on frictional forces applied to different bracket types in combination with archwires made of NiTi and stainless steel of variable cross section. The measurements were carried out in artificial saliva. Three-way ANOVA and Bonferroni post-hoc tests (α=0.05) were applied. Except for one subgroup the combination of normal force, bracket system and wire dimension had significant effect on friction (p<0.001) as friction increased with increasing normal forces. Only moderately tied ligatures or passive self-ligating brackets generate low friction forces. There was a statistically significant order (0.016"×0.022"<0.018"×0.025"<0.019"×0.025") for stainless steel wire material. Finite element modeling simulation showed the increasing effect of active clip force on friction especially for 0.025" wire profiles. If compared to NiTi wires, stainless steel archwires delivered higher friction. Combinations between wire-type and ligation should be chosen carefully for the intended treatment step.


Asunto(s)
Soportes Ortodóncicos , Alambres para Ortodoncia , Aleaciones Dentales , Análisis del Estrés Dental , Fricción , Ensayo de Materiales , Diseño de Aparato Ortodóncico , Acero Inoxidable , Titanio
18.
Int J Mol Sci ; 23(3)2022 Jan 28.
Artículo en Inglés | MEDLINE | ID: mdl-35163446

RESUMEN

This study aimed to investigate the effects of different magnitudes and durations of static tensile strain on human periodontal ligament cells (hPDLCs), focusing on osteogenesis, mechanosensing and inflammation. Static tensile strain magnitudes of 0%, 3%, 6%, 10%, 15% and 20% were applied to hPDLCs for 1, 2 and 3 days. Cell viability was confirmed via live/dead cell staining. Reference genes were tested by reverse transcription quantitative real-time polymerase chain reaction (RT-qPCR) and assessed. The expressions of TNFRSF11B, ALPL, RUNX2, BGLAP, SP7, FOS, IL6, PTGS2, TNF, IL1B, IL8, IL10 and PGE2 were analyzed by RT-qPCR and/or enzyme-linked immunosorbent assay (ELISA). ALPL and RUNX2 both peaked after 1 day, reaching their maximum at 3%, whereas BGLAP peaked after 3 days with its maximum at 10%. SP7 peaked after 1 day at 6%, 10% and 15%. FOS peaked after 3 days with its maximum at 3%, 6% and 15%. The expressions of IL6 and PTGS2 both peaked after 1 day, with their minimum at 10%. PGE2 peaked after 1 day (maximum at 20%). The ELISA of IL6 peaked after 3 days, with the minimum at 10%. In summary, the lower magnitudes promoted osteogenesis and caused less inflammation, while the higher magnitudes inhibited osteogenesis and enhanced inflammation. Among all magnitudes, 10% generally caused a lower level of inflammation with a higher level of osteogenesis.


Asunto(s)
Perfilación de la Expresión Génica/métodos , Redes Reguladoras de Genes , Ligamento Periodontal/citología , Técnicas de Movimiento Dental/métodos , Supervivencia Celular , Células Cultivadas , Regulación de la Expresión Génica , Humanos , Osteogénesis , Ligamento Periodontal/metabolismo , Estrés Mecánico
19.
Prog Orthod ; 22(1): 40, 2021 Dec 06.
Artículo en Inglés | MEDLINE | ID: mdl-34866163

RESUMEN

OBJECTIVE: Nowadays, CAD/CAM technologies enrich orthodontics in several ways. While they are commonly used for diagnoses and treatment planning, they can also be applied to create individualized bracket systems. The purpose of this prospective quasi-randomized study was to evaluate the clinical efficiency of a customized bracket system and its comparison with directly bonded conventional self-ligating bracket treatment. MATERIALS AND METHODS: Altogether 38 patients were separated into two groups, treated either with direct bonded self-ligating brackets (Damon, Ormco, USA) or with indirect bonded customized CAD/CAM brackets (Insignia™, Ormco, USA). Overall treatment time, number of treatment appointments, number of lost or repositioned brackets, number of arch wires and wire bends, Little Irregularity Index, cephalometric analyses and ABO scores were compared. Superimpositions of the virtual set-ups and the treatment results of the CAD/CAM group were performed to evaluate the clinical realization of the treatment planning. RESULTS: No differences between both treatment groups were found concerning overall treatment time, number of appointments and number of archwire bends. Bonding failures occurred more often using the CAD/CAM system. Indirectly bonded brackets did not have to be repositioned as often as directly bonded brackets. Treatment results with both systems were similar concerning their effects on the reduction of ABO scores. The number of used archwires was higher in the CAD/CAM group. Treatment with both systems led to further proclination of the incisors. Proclination in the lower jaw was greater than proclination in the upper jaw, and there was a statistically significant difference between the two treatment systems. Comparing the treatment results with the virtual set-ups, mesial positions were met best, followed by vertical positions. Transversal positions showed the greatest discrepancies. Concerning angles, values of angulation showed greatest accordance to the virtual set-up, while values of inclinations showed greatest discrepancies. CONCLUSION: In comparison with a direct bonded self-ligating bracket system the use of indirect bonded customized CAD/CAM brackets showed only minor influence on treatment efficiency and treatment outcomes. Transversal expansion, deep bite correction, expression of torque and anchorage loss remain challenges in the treatment with straight-wire appliances. Trial registration DRKS, DRKS00024350. Registered 15 February 2021, https://www.drks.de/drks_web/navigate.do?navigationId=trial.HTML&TRIAL_ID=DRKS00024350 .


Asunto(s)
Soportes Ortodóncicos , Alambres para Ortodoncia , Cefalometría , Humanos , Diseño de Aparato Ortodóncico , Estudios Prospectivos
20.
Front Bioeng Biotechnol ; 9: 695053, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34513810

RESUMEN

Orthodontic tooth movement is based on the remodeling of tooth-surrounding tissues in response to mechanical stimuli. During this process, human periodontal ligament cells (hPDLCs) play a central role in mechanosensing and mechanotransduction. Various in vitro models have been introduced to investigate the effect of tension on hPDLCs. They provide a valuable body of knowledge on how tension influences relevant genes, proteins, and metabolites. However, no systematic review summarizing these findings has been conducted so far. Aim of this systematic review was to identify all related in vitro studies reporting tension application on hPDLCs and summarize their findings regarding force parameters, including magnitude, frequency and duration. Expression data of genes, proteins, and metabolites was extracted and summarized. Studies' risk of bias was assessed using tailored risk of bias tools. Signaling pathways were identified by protein-protein interaction (PPI) networks using STRING and GeneAnalytics. According to our results, Flexcell Strain Unit® and other silicone-plate or elastic membrane-based apparatuses were mainly adopted. Frequencies of 0.1 and 0.5 Hz were predominantly applied for dynamic equibiaxial and uniaxial tension, respectively. Magnitudes of 10 and 12% were mostly employed for dynamic tension and 2.5% for static tension. The 10 most commonly investigated genes, proteins and metabolites identified, were mainly involved in osteogenesis, osteoclastogenesis or inflammation. Gene-set enrichment analysis and PPI networks gave deeper insight into the involved signaling pathways. This review represents a brief summary of the massive body of knowledge in this field, and will also provide suggestions for future researches on this topic.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...