Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Sci Rep ; 9(1): 17720, 2019 Nov 27.
Artículo en Inglés | MEDLINE | ID: mdl-31776363

RESUMEN

Aluminum is a common dopant across oxide cathodes for improving the bulk and cathode-electrolyte interface (CEI) stability. Aluminum in the bulk is known to enhance structural and thermal stability, yet the exact influence of aluminum at the CEI remains unclear. To address this, we utilized a combination of X-ray photoelectron and absorption spectroscopy to identify aluminum surface environments and extent of transition metal reduction for Ni-rich LiNi0.8Co0.2-yAlyO2 (0%, 5%, or 20% Al) layered oxide cathodes tested at 4.75 V under thermal stress (60 °C). For these tests, we compared the conventional LiPF6 salt with the more thermally stable LiBF4 salt. The CEI layers are inherently different between these two electrolyte salts, particularly for the highest level of Al-doping (20%) where a thicker (thinner) CEI layer is found for LiPF6 (LiBF4). Focusing on the aluminum environment, we reveal the type of surface aluminum species are dependent on the electrolyte salt, as Al-O-F- and Al-F-like species form when using LiPF6 and LiBF4, respectively. In both cases, we find cathode-electrolyte reactions drive the formation of a protective Al-F-like barrier at the CEI in Al-doped oxide cathodes.

2.
Rev Sci Instrum ; 89(7): 073105, 2018 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-30068129

RESUMEN

Hard X-ray photoelectron spectroscopy (HAXPES) has seen continuous development since the first experiments in the 1970s. HAXPES systems are predominantly located at synchrotron sources due to low photoionization cross sections necessitating high X-ray intensities, which limits the technique's availability to a wide range of users and potential applications. Here, a new laboratory-based instrument capable of delivering monochromated X-rays with an energy of 9.25 keV and a microfocused 30 × 45 µm2 X-ray spot is introduced. The system gives an excellent energy resolution of below 500 meV coupled with good X-ray intensity. It allows stable measurements under grazing incidence conditions to maximise signal intensities. This article outlines the instrument behavior, showcases applications including bulk and multilayer measurements, and describes the overall performance of the spectrometer. This system presents an alternative to synchrotron-based experimental end stations and will help expand the number and range of HAXPES experiments performed in the future.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA