Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Transplant Direct ; 9(10): e1533, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37745948

RESUMEN

Background: Bacterial colonization (BC) of the lower airways is common in lung transplant recipients (LTRs) and increases the risk of chronic lung allograft dysfunction. Diagnosis often requires bronchoscopy. Exhaled breath analysis using electronic nose (eNose) technology may noninvasively detect BC in LTRs. Therefore, we aimed to assess the diagnostic accuracy of an eNose to detect BC in LTRs. Methods: We performed a cross-sectional analysis within a prospective, single-center cohort study assessing the diagnostic accuracy of detecting BC using eNose technology in LTRs. In the outpatient clinic, consecutive LTR eNose measurements were collected. We assessed and classified the eNose measurements for the presence of BC. Using supervised machine learning, the diagnostic accuracy of eNose for BC was assessed in a random training and validation set. Model performance was evaluated using receiver operating characteristic analysis. Results: In total, 161 LTRs were included with 80 exclusions because of various reasons. Of the remaining 81 patients, 16 (20%) were classified as BC and 65 (80%) as non-BC. eNose-based classification of patients with and without BC provided an area under the curve of 0.82 in the training set and 0.97 in the validation set. Conclusions: Exhaled breath analysis using eNose technology has the potential to noninvasively detect BC.

2.
J Breath Res ; 17(4)2023 09 05.
Artículo en Inglés | MEDLINE | ID: mdl-37582348

RESUMEN

In order to prevent long-term immunity-related complications after lung transplantation, close monitoring of immunosuppressant levels using therapeutic drug monitoring (TDM) is paramount. Novel electronic nose (eNose) technology may be a non-invasive alternative to the current invasive procedures for TDM. We investigated the diagnostic and categorization capacity of eNose breathprints for Tacrolimus trough blood plasma levels (TACtrough) in lung transplant recipients (LTRs). We performed eNose measurements in stable LTR attending the outpatient clinic. We evaluated (1) the correlation between eNose measurements and TACtrough, (2) the diagnostic capacity of eNose technology for TACtrough, and (3) the accuracy of eNose technology for categorization of TACtroughinto three clinically relevant categories (low: <7µg ml-1, medium: 7-10µg ml-1, and high: >10µg ml-1). A total of 186 measurements from 86 LTR were included. There was a weak but statistically significant correlation (r= 0.21,p= 0.004) between the eNose measurements and TACtrough. The root mean squared error of prediction for the diagnostic capacity was 3.186 in the training and 3.131 in the validation set. The accuracy of categorization ranged between 45%-63% for the training set and 52%-69% in the validation set. There is a weak correlation between eNose breathprints and TACtroughin LTR. However, the diagnostic as well as categorization capacity for TACtroughusing eNose breathprints is too inaccurate to be applicable in TDM.


Asunto(s)
Trasplante de Pulmón , Tacrolimus , Humanos , Monitoreo de Drogas , Pruebas Respiratorias/métodos , Nariz Electrónica
3.
J Heart Lung Transplant ; 42(2): 236-245, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36283951

RESUMEN

BACKGROUND: There is a need for reliable biomarkers for the diagnosis of chronic lung allograft dysfunction (CLAD). In this light, we investigated the diagnostic value of exhaled breath analysis using an electronic nose (eNose) for CLAD, CLAD phenotype, and CLAD stage in lung transplant recipients (LTR). METHODS: We performed eNose measurements in LTR with and without CLAD, visiting the outpatient clinic. Through supervised machine learning, the diagnostic value of eNose for CLAD was assessed in a random training and validation set. Next, we investigated the diagnostic value of the eNose measurements combined with known risk factors for CLAD. Model performance was evaluated using ROC-analysis. RESULTS: We included 152 LTR (median age 60 years, 49% females), of whom 38 with CLAD. eNose-based classification of patients with and without CLAD provided an AUC of 0.86 in the training set, and 0.82 in the validation set. After adding established risk factors for CLAD (age, gender, type of transplantation, time after transplantation and prior occurrence of acute cellular rejection) to a model with the eNose data, the discriminative ability of the model improved to an AUC of 0.94 (p = 0.02) in the training set and 0.94 (p = 0.04) in the validation set. Discrimination between BOS and RAS was good (AUC 0.95). Discriminative ability for other phenotypes (AUCs ranging 0.50-0.92) or CLAD stages (AUC 0.56) was limited. CONCLUSION: Exhaled breath analysis using eNose is a promising novel biomarker for enabling diagnosis and phenotyping CLAD. eNose technology could be a valuable addition to the diagnostic armamentarium for suspected graft failure in LTR.


Asunto(s)
Nariz Electrónica , Trasplante de Pulmón , Femenino , Masculino , Aloinjertos , Trasplante de Pulmón/efectos adversos , Curva ROC , Trasplante Homólogo , Humanos
4.
Front Immunol ; 14: 1254659, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-38239369

RESUMEN

Background: Data on cellular response and the decay of antibodies and T cells in time are scarce in lung transplant recipients (LTRs). Additionally, the development and durability of humoral and cellular immune responses have not been investigated in patients on the waitlist for lung transplantation (WLs). Here, we report our 6-month follow-up of humoral and cellular immune responses of LTRs and WLs, compared with controls. Methods: Humoral responses to two doses of the mRNA-1273 vaccination were assessed by determining spike (S)-specific IgG antibodies and neutralizing antibodies. Cellular responses were investigated by interferon gamma (IFN-γ) release assay (IGRA) and IFN-γ ELISpot assay at 28 days and 6 months after the second vaccination. Results: In LTRs, the level of antibodies and T-cell responses was significantly lower at 28 days after the second vaccination. Also, WLs had lower antibody titers and lower T-cell responses compared with controls. Six months after the second vaccination, all groups showed a decrease in antibody titers and T-cell responses. In WLs, the rate of decline of neutralizing antibodies and T-cell responses was significantly higher than in controls. Conclusion: Our results show that humoral and cellular responses in LTRs, if they develop, decrease at rates comparable with controls. In contrast, the inferior cellular responses and the rapid decay of both humoral and cellular responses in the WL groups imply that WLs may not be protected adequately by two vaccinations and repeat boostering may be necessary to induce protection that lasts beyond the months immediately post-transplantation.


Asunto(s)
COVID-19 , Receptores de Trasplantes , Humanos , Vacunas contra la COVID-19 , Listas de Espera , Estudios de Seguimiento , COVID-19/prevención & control , Vacunación , Anticuerpos Neutralizantes , Inmunidad Celular , Pulmón
5.
ERJ Open Res ; 8(3)2022 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-35821754

RESUMEN

Exhaled breath analysis using eNose technology holds promise as a point-of-care indicator of clinical status after lung transplantation. This case study invites further exploration of eNose technology in the field of lung transplantation. https://bit.ly/3wgQ3DE.

6.
J Heart Lung Transplant ; 41(6): 765-772, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-35606065

RESUMEN

BACKGROUND: Serological responses to COVID-19 vaccination are diminished in recipients of solid organ transplants, especially in lung transplant recipients (LTR), probably as result of immunosuppressive treatment. There is currently no marker of immunosuppression that can be used to predict the COVID-19 vaccination response. Here, we study whether torque tenovirus (TTV), a highly prevalent virus can be used as an indicator of immunosuppression. METHODS: The humoral response to the mRNA 1273 vaccine was assessed in 103 LTR, who received a transplant between 4 and 237 months prior to vaccination, by measuring Spike (S)-specific IgG levels at baseline, 28 days after first, and 28 days after the second vaccination. TTV loads were determined by RT-PCR and Pearson's correlation coefficient was calculated to correlate serological responses to TTV load. RESULTS: Humoral responses to COVID-19 vaccination were observed in 41 of 103 (40%) LTR at 28 days after the second vaccination. Sixty-two of 103 (60%) were non-responders. Lower TTV loads at baseline (significantly) correlated with higher S-specific antibodies and a higher percentage of responders. Lower TTV loads also strongly correlated with longer time since transplantation, indicating that participants with lower TTV loads were longer after transplantation. CONCLUSIONS: This study shows a better humoral response to the SARS-CoV-2 vaccine in subjects with a lower TTV load pre-vaccination. In addition, TTV load correlates with the time after transplantation. Further studies on the use of TTV load in vaccination efficacy studies in immunocompromised cohorts should provide leads for the potential use of this marker for optimizing vaccination response.


Asunto(s)
COVID-19 , Torque teno virus , Vacuna nCoV-2019 mRNA-1273 , COVID-19/prevención & control , Vacunas contra la COVID-19 , Humanos , Pulmón , SARS-CoV-2 , Torque , Torque teno virus/genética , Receptores de Trasplantes , Vacunación
7.
J Pers Med ; 10(4)2020 Nov 21.
Artículo en Inglés | MEDLINE | ID: mdl-33233334

RESUMEN

Home spirometry after lung transplantation is common practice, to monitor graft function. However, there is little experience with online home monitoring applications with direct data transfer to the hospital. We evaluated the feasibility and patient experiences with a new online home monitoring application, integrated with a Bluetooth-enabled spirometer and real-time data transfer. Consecutive lung transplant recipients were asked to evaluate this home monitoring application for three months in a pilot study. Home spirometry measurements were compared with in-hospital lung function tests (the forced expiratory volume in 1 s (FEV1) and forced vital capacity (FVC)) at the end of the study. Ten patients participated. The home and hospital spirometry measurements showed a high correlation, for both the FEV1 (r = 0.99, p < 0.01) and FVC (r = 0.99, p < 0.01). The adherence and patient satisfaction were high, and the patients preferred the home monitoring application over the current home spirometer, with a difference of 1.4 ± 1.5 points on a scale from 0 to 10 (p = 0.02). Online home monitoring with direct data transfer is feasible and reliable after lung transplantation and results in high patient satisfaction. Whether the implementation of online home monitoring enables the earlier detection of lung function decline and improves patient and graft outcomes will be the subject of future research.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...