Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 29
Filtrar
1.
J Digit Imaging ; 35(2): 240-247, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-35083620

RESUMEN

Organs-at-risk contouring is time consuming and labour intensive. Automation by deep learning algorithms would decrease the workload of radiotherapists and technicians considerably. However, the variety of metrics used for the evaluation of deep learning algorithms make the results of many papers difficult to interpret and compare. In this paper, a qualitative evaluation is done on five established metrics to assess whether their values correlate with clinical usability. A total of 377 CT volumes with heart delineations were randomly selected for training and evaluation. A deep learning algorithm was used to predict the contours of the heart. A total of 101 CT slices from the validation set with the predicted contours were shown to three experienced radiologists. They examined each slice independently whether they would accept or adjust the prediction and if there were (small) mistakes. For each slice, the scores of this qualitative evaluation were then compared with the Sørensen-Dice coefficient (DC), the Hausdorff distance (HD), pixel-wise accuracy, sensitivity and precision. The statistical analysis of the qualitative evaluation and metrics showed a significant correlation. Of the slices with a DC over 0.96 (N = 20) or a 95% HD under 5 voxels (N = 25), no slices were rejected by the readers. Contours with lower DC or higher HD were seen in both rejected and accepted contours. Qualitative evaluation shows that it is difficult to use common quantification metrics as indicator for use in clinic. We might need to change the reporting of quantitative metrics to better reflect clinical acceptance.


Asunto(s)
Aprendizaje Profundo , Algoritmos , Benchmarking , Humanos , Órganos en Riesgo , Tomografía Computarizada por Rayos X/métodos
2.
Neth Heart J ; 30(2): 84-95, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-34143416

RESUMEN

BACKGROUND: The p.Arg14del (c.40_42delAGA) phospholamban (PLN) pathogenic variant is a founder mutation that causes dilated cardiomyopathy (DCM) and arrhythmogenic cardiomyopathy (ACM). Carriers are at increased risk of malignant ventricular arrhythmias and heart failure, which has been ascribed to cardiac fibrosis. Importantly, cardiac fibrosis appears to be an early feature of the disease, occurring in many presymptomatic carriers before the onset of overt disease. As with most monogenic cardiomyopathies, no evidence-based treatment is available for presymptomatic carriers. AIMS: The PHOspholamban RElated CArdiomyopathy intervention STudy (iPHORECAST) is designed to demonstrate that pre-emptive treatment of presymptomatic PLN p.Arg14del carriers using eplerenone, a mineralocorticoid receptor antagonist with established antifibrotic effects, can reduce disease progression and postpone the onset of overt disease. METHODS: iPHORECAST has a multicentre, prospective, randomised, open-label, blinded endpoint (PROBE) design. Presymptomatic PLN p.Arg14del carriers are randomised to receive either 50 mg eplerenone once daily or no treatment. The primary endpoint of the study is a multiparametric assessment of disease progression including cardiac magnetic resonance parameters (left and right ventricular volumes, systolic function and fibrosis), electrocardiographic parameters (QRS voltage, ventricular ectopy), signs and/or symptoms related to DCM and ACM, and cardiovascular death. The follow-up duration is set at 3 years. BASELINE RESULTS: A total of 84 presymptomatic PLN p.Arg14del carriers (n = 42 per group) were included. By design, at baseline, all participants were in New York Heart Association (NHYA) class I and had a left ventricular ejection fraction > 45% and < 2500 ventricular premature contractions during 24-hour Holter monitoring. There were no statistically significant differences between the two groups in any of the baseline characteristics. The study is currently well underway, with the last participants expected to finish in 2021. CONCLUSION: iPHORECAST is a multicentre, prospective randomised controlled trial designed to address whether pre-emptive treatment of PLN p.Arg14del carriers with eplerenone can prevent or delay the onset of cardiomyopathy. iPHORECAST has been registered in the clinicaltrials.gov-register (number: NCT01857856).

3.
Int J Cardiol ; 293: 211-217, 2019 10 15.
Artículo en Inglés | MEDLINE | ID: mdl-31109778

RESUMEN

BACKGROUND: In pulmonary arterial hypertension (PAH), right ventricular (RV) failure is the main cause of mortality. Non-invasive estimation of ventricular-vascular coupling ratio (VVCR), describing contractile response to afterload, could be a valuable tool for monitoring clinical course in children with PAH. This study aimed to test two hypotheses: VVCR by cardiac magnetic resonance (VVCRCMR) correlates with conventional VVCR by right heart catheterization (VVCRRHC) and both correlate with disease severity. METHODS AND RESULTS: Twenty-seven patients diagnosed with idiopathic and associated PAH without post-tricuspid shunt, who underwent RHC and CMR within 17 days at two specialized centers for pediatric PAH were retrospectively studied. Clinical functional status and hemodynamic data were collected. Median age at time of MRI was 14.3 years (IQR: 11.1-16.8), median PVRi 7.6 WU × m2 (IQR: 4.1-12.2), median mPAP 40 mm Hg (IQR: 28-55) and median WHO-FC 2 (IQR: 2-3). VVCRCMR, defined as stroke volume/end-systolic volume ratio was compared to VVCRRHC by single-beat pressure method using correlation and Bland-Altman plots. VVCRCMR and VVCRRHC showed a strong correlation (r = 0.83, p < 0.001). VVCRCMR and VVCRRHC both correlated with clinical measures of disease severity (pulmonary vascular resistance index [PVRi], mean pulmonary artery pressure [mPAP], mean right atrial pressure [mRAP], and World Health Organization functional class [WHO-FC]; all p ≤ 0.02). CONCLUSIONS: Non-invasively measured VVCRCMR is feasible in pediatric PAH and comparable to invasively assessed VVCRRHC. Both correlate with functional and hemodynamic measures of disease severity. The role of VVCR assessed by CMR and RHC in clinical decision-making and follow-up in pediatric PAH warrants further clinical investigation.


Asunto(s)
Cateterismo Cardíaco/métodos , Imagen por Resonancia Cinemagnética/métodos , Hipertensión Arterial Pulmonar , Disfunción Ventricular Derecha , Cuidados Posteriores/métodos , Niño , Toma de Decisiones Clínicas , Investigación sobre la Eficacia Comparativa , Precisión de la Medición Dimensional , Femenino , Ventrículos Cardíacos/diagnóstico por imagen , Ventrículos Cardíacos/fisiopatología , Humanos , Masculino , Hipertensión Arterial Pulmonar/complicaciones , Hipertensión Arterial Pulmonar/diagnóstico , Hipertensión Arterial Pulmonar/fisiopatología , Índice de Severidad de la Enfermedad , Disfunción Ventricular Derecha/diagnóstico , Disfunción Ventricular Derecha/etiología , Disfunción Ventricular Derecha/fisiopatología
4.
Int J Cardiovasc Imaging ; 34(6): 947-957, 2018 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-29285725

RESUMEN

The objective of this study was to evaluate the influence of iterative reconstruction on coronary calcium scores (CCS) at different heart rates for four state-of-the-art CT systems. Within an anthropomorphic chest phantom, artificial coronary arteries were translated in a water-filled compartment. The arteries contained three different calcifications with low (38 mg), medium (80 mg) and high (157 mg) mass. Linear velocities were applied, corresponding to heart rates of 0, < 60, 60-75 and > 75 bpm. Data were acquired on four state-of-the-art CT systems (CT1-CT4) with routinely used CCS protocols. Filtered back projection (FBP) and three increasing levels of iterative reconstruction (L1-L3) were used for reconstruction. CCS were quantified as Agatston score and mass score. An iterative reconstruction susceptibility (IRS) index was used to assess susceptibility of Agatston score (IRSAS) and mass score (IRSMS) to iterative reconstruction. IRS values were compared between CT systems and between calcification masses. For each heart rate, differences in CCS of iterative reconstructed images were evaluated with CCS of FBP images as reference, and indicated as small (< 5%), medium (5-10%) or large (> 10%). Statistical analysis was performed with repeated measures ANOVA tests. While subtle differences were found for Agatston scores of low mass calcification, medium and high mass calcifications showed increased CCS up to 77% with increasing heart rates. IRSAS of CT1-T4 were 17, 41, 130 and 22% higher than IRSMS. Not only were IRS significantly different between all CT systems, but also between calcification masses. Up to a fourfold increase in IRS was found for the low mass calcification in comparison with the high mass calcification. With increasing iterative reconstruction strength, maximum decreases of 21 and 13% for Agatston and mass score were found. In total, 21 large differences between Agatston scores from FBP and iterative reconstruction were found, while only five large differences were found between FBP and iterative reconstruction mass scores. Iterative reconstruction results in reduced CCS. The effect of iterative reconstruction on CCS is more prominent with low-density calcifications, high heart rates and increasing iterative reconstruction strength.


Asunto(s)
Angiografía por Tomografía Computarizada/normas , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Frecuencia Cardíaca , Interpretación de Imagen Radiográfica Asistida por Computador/normas , Calcificación Vascular/diagnóstico por imagen , Simulación por Computador , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/fisiopatología , Humanos , Modelos Cardiovasculares , Fantasmas de Imagen , Calcificación Vascular/fisiopatología
5.
Int J Cardiovasc Imaging ; 34(6): 959-966, 2018 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-29285727

RESUMEN

To evaluate the influence of heart rate on coronary calcium scores (CCS) using a dynamic phantom on four high-end computed tomography (CT) systems from different manufacturers. Artificial coronary arteries were moved in an anthropomorphic chest phantom at linear velocities, corresponding to < 60, 60-75 and > 75 beats per minute (bpm). Data was acquired with routinely used clinical protocols for CCS on four high-end CT systems (CT1-CT4). CCS, quantified as Agatston and mass scores were compared to reference scores at < 60 bpm. Influence of heart rate was assessed for each system with the cardiac motion susceptibility (CMS) Index. At increased heart rates (> 75 bpm), Agatston scores of the low mass calcification were similar to the reference score, while Agatston scores of the medium and high mass calcification increased significantly up to 50% for all CT systems. Threefold CMS increases at > 75 bpm in comparison with < 60 bpm were shown. For medium and high mass calcifications, significant differences in CMS between CT systems were found. Heart rate substantially influences CCS for high-end CT systems of four major manufacturers, but CT systems differ in motion susceptibility. Follow-up CCS CT scans should be acquired on the same CT system and protocol, and preferably with comparable heart rates.


Asunto(s)
Angiografía por Tomografía Computarizada , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Frecuencia Cardíaca , Fantasmas de Imagen , Calcificación Vascular/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/fisiopatología , Humanos , Valor Predictivo de las Pruebas , Calcificación Vascular/fisiopatología
6.
Int J Cardiovasc Imaging ; 33(6): 899-914, 2017 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-28102510

RESUMEN

To evaluate the influence of dose reduction in combination with iterative reconstruction (IR) on coronary calcium scores (CCS) in a dynamic phantom on state-of-the-art CT systems from different manufacturers. Calcified inserts in an anthropomorphic chest phantom were translated at 20 mm/s corresponding to heart rates between 60 and 75 bpm. The inserts were scanned five times with routinely used CCS protocols at reference dose and 40 and 80% dose reduction on four high-end CT systems. Filtered back projection (FBP) and increasing levels of IR were applied. Noise levels were determined. CCS, quantified as Agatston and mass scores, were compared to physical mass and scores at FBP reference dose. For the reference dose in combination with FBP, noise level variation between CT systems was less than 18%. Decreasing dose almost always resulted in increased CCS, while at increased levels of IR, CCS decreased again. The influence of IR on CCS was smaller than the influence of dose reduction. At reference dose, physical mass was underestimated 3-30%. All CT systems showed similar CCS at 40% dose reduction in combinations with specific reconstructions. For some CT systems CCS was not affected at 80% dose reduction, in combination with IR. This multivendor study showed that radiation dose reductions of 40% did not influence CCS in a dynamic phantom using state-of-the-art CT systems in combination with specific reconstruction settings. Dose reduction resulted in increased noise and consequently increased CCS, whereas increased IR resulted in decreased CCS.


Asunto(s)
Angiografía por Tomografía Computarizada/instrumentación , Angiografía Coronaria/instrumentación , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Vasos Coronarios/diagnóstico por imagen , Fantasmas de Imagen , Dosis de Radiación , Exposición a la Radiación/prevención & control , Interpretación de Imagen Radiográfica Asistida por Computador , Tomógrafos Computarizados por Rayos X , Calcificación Vascular/diagnóstico por imagen , Angiografía por Tomografía Computarizada/métodos , Angiografía Coronaria/métodos , Diseño de Equipo , Valor Predictivo de las Pruebas , Exposición a la Radiación/efectos adversos
7.
Horm Cancer ; 6(4): 168-75, 2015 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-25985881

RESUMEN

Radiological examination may unexpectedly reveal an adrenal mass. Current algorithms for differentiating between benign and malignant lesions mainly rely on size and densitometry on unenhanced CT, which have limited specificity. We examined the diagnostic value of urinary steroid profiling by gas chromatography/mass-spectrometry (GC/MS) in differentiating between benign and malignant adrenal tumors. A retrospective study in two referral centers for patients with adrenal disease was performed. All urinary steroid profiles ordered for evaluation of an adrenal tumor between January 2000 and November 2011 were examined. Patients were diagnosed with adrenal cortical carcinoma (ACC), adrenal cortical adenoma (ACA), or other adrenal mass. Results of hormonal measurements, imaging studies, pathology reports, and clinical outcome were retrieved from medical records. The diagnostic value of individual urinary steroid metabolites was determined by receiver operating characteristics analysis. Cut-off values were compared to reference values from an age and gender-standardized population of healthy controls. Eighteen steroid metabolites were excreted in significantly higher concentrations in patients with ACC (n = 27) compared to patients with ACA (n = 107) or other adrenal conditions (n = 18). Tetrahydro-11-deoxycortisol (THS) at a cut-off value of 2.35 µmol/24 h differentiated ACC from other adrenal disorders with 100% sensitivity and 99% specificity. Elevated urinary excretion of THS was associated with a very high sensitivity and specificity to differentiate between an ACC and a benign adrenal mass. Urinary steroid profiling might be a useful diagnostic test for the evaluation of patients with an adrenal incidentaloma.


Asunto(s)
Neoplasias de la Corteza Suprarrenal/diagnóstico , Carcinoma/diagnóstico , Esteroides/orina , Adulto , Anciano , Estudios de Cohortes , Cortodoxona/análogos & derivados , Cortodoxona/orina , Femenino , Humanos , Masculino , Persona de Mediana Edad , Pronóstico
8.
Eur J Vasc Endovasc Surg ; 46(5): 542-8, 2013 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-24091093

RESUMEN

OBJECTIVES: Abdominal aortic aneurysm (AAA) is a major cause of death in developed countries. The AAA diameter is still the only validated prognostic measure for rupture, and therapeutic interventions are initiated accordingly. This still leads to unnecessary interventions in some cases or unidentified impending ruptures. Vascular calcification has been validated abundantly as a risk factor in the cardiovascular field and may strengthen the rupture risk assessment of the AAA. With this study we aim to assess the correlation between AAA calcification and rupture risk in a retrospective unmatched case-control population. METHODS: A database of 334 AAA patients was evaluated. Three groups were formed: elective (eAAA; n = 233), ruptured (rAAA; n = 73) and symptomatic non-ruptured (sAAA; n = 28) AAA patients. The Abdominal Aortic Calcification-8 score (AAC-8) was used to measure the severity of vascular calcification. RESULTS: The AAA diameter (61 ± 12 mm vs. 74 ± 21 mm; p < .001) and AAC-8 score (3.4 ± 2 points vs. 4.9 ± 2.3 points; p < .001) of the eAAA and the combined rAAA and sAAA groups, respectively, were significantly different after univariate analysis. Multivariate analysis showed that larger AAA diameter (odds ratio [OR]: 1.048/mm increase; 95% confidence interval [CI]: 1.042-1.082; p < .001) and a higher AAC-8 score (OR: 1.34/point increase; 95% CI: 1.19-1.53; p < .001) were significantly associated with development into a sAAA or rAAA. Peripheral artery disease was significantly correlated to eventual elective treatment (OR: 0.39; 95% CI: .15-1; p = .049). CONCLUSION: This study suggests a trend of an increased degree of calcification in symptomatic or even ruptured AAA patients compared with elective AAA patients.


Asunto(s)
Aneurisma de la Aorta Abdominal/complicaciones , Rotura de la Aorta/etiología , Calcificación Vascular/complicaciones , Anciano , Anciano de 80 o más Años , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/cirugía , Rotura de la Aorta/diagnóstico por imagen , Rotura de la Aorta/cirugía , Aortografía/métodos , Procedimientos Quirúrgicos Electivos , Urgencias Médicas , Femenino , Humanos , Modelos Logísticos , Masculino , Persona de Mediana Edad , Análisis Multivariante , Oportunidad Relativa , Valor Predictivo de las Pruebas , Pronóstico , Estudios Retrospectivos , Factores de Riesgo , Índice de Severidad de la Enfermedad , Tomografía Computarizada por Rayos X , Calcificación Vascular/diagnóstico por imagen , Calcificación Vascular/cirugía , Procedimientos Quirúrgicos Vasculares
9.
Eur J Radiol ; 82(2): e58-63, 2013 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-23092538

RESUMEN

INTRODUCTION: Multi detector computed tomography (MDCT) underestimates the coronary calcium score as compared to electron beam tomography (EBT). Therefore clinical risk stratification based on MDCT calcium scoring may be inaccurate. The aim of this study was to assess the feasibility of a new phantom which enables establishment of a calcium scoring protocol for MDCT that yields a calcium score comparable to the EBT values and to the physical mass. MATERIALS AND METHODS: A phantom containing 100 small calcifications ranging from 0.5 to 2.0mm was scanned on EBT using a standard coronary calcium protocol. In addition, the phantom was scanned on a 320-row MDCT scanner using different scanning, reconstruction and scoring parameters (tube voltage 80-135 kV, slice thickness 0.5-3.0mm, reconstruction kernel FC11-FC15 and threshold 110-150 HU). The Agatston and mass score of both modalities was compared and the influence of the parameters was assessed. RESULTS: On EBT the Agatston and mass scores were between 0 and 20, and 0 and 3mg, respectively. On MDCT the Agatston and mass scores were between 0 and 20, and 0 and 4 mg, respectively. All parameters showed an influence on the calcium score. The Agatston score on MDCT differed 52% between the 80 and 135kV, 65% between 0.5 and 3.0mm and 48% between FC11 and FC15. More calcifications were detected with a lower tube voltage, a smaller slice thickness, a sharper kernel and a lower threshold. Based on these observations an acquisition protocol with a tube voltage of 100 kV and two reconstructions protocols were defined with a FC12 reconstruction kernel; one with a slice thickness of 3.0mm and a one with a slice thickness of 0.5mm. This protocol yielded an Agatston score as close to the EBT as possible, but also a mass score as close to the physical phantom value as possible, respectively. CONCLUSION: With the new phantom one acquisition protocol and two reconstruction protocols can be defined which produces Agatston scores comparable to EBT values and to the physical mass.


Asunto(s)
Algoritmos , Calcinosis/diagnóstico por imagen , Angiografía Coronaria/instrumentación , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Fantasmas de Imagen , Interpretación de Imagen Radiográfica Asistida por Computador/instrumentación , Tomografía Computarizada por Rayos X/instrumentación , Calcinosis/complicaciones , Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/complicaciones , Diseño de Equipo , Análisis de Falla de Equipo , Humanos , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Tomografía Computarizada por Rayos X/métodos
10.
Neth Heart J ; 20(10): 419-24, 2012 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-22918718

RESUMEN

BACKGROUND: Data on long-term complications in adult patients with congenital heart disease (ACHD) and a prosthetic valve are scarce. Moreover, the influence of prosthetic valves on quality of life (QoL) and functional outcome in ACHD patients with prosthetic valves has not been studied. OBJECTIVES: The primary objective of the PROSTAVA study is to investigate the relation between prosthetic valve characteristics (type, size and location) and functional outcome as well as QoL in ACHD patients. The secondary objectives are to investigate the prevalence and predictors of prosthesis-related complications including prosthesis-patient mismatch. METHODS: The PROSTAVA study, a multicentre cross-sectional observational study, will include approximately 550 ACHD patients with prosthetic valves. Primary outcome measures are maximum oxygen uptake during cardiopulmonary exercise testing and QoL. Secondary outcomes are the prevalence and incidence of valve-related complications including prosthesis-patient mismatch. Other evaluations are medical history, physical examination, echocardiography, MRI, rhythm monitoring and laboratory evaluation (including NT-proBNP). IMPLICATIONS: Identification of the relation between prosthetic valve characteristics in ACHD patients on one hand and functional outcome, QoL, the prevalence and predictors of prosthesis-related complications on the other hand may influence the choice of valve prosthesis, the indication for more extensive surgery and the indication for re-operation.

11.
J Nucl Cardiol ; 17(3): 479-85, 2010 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-20238193

RESUMEN

BACKGROUND: In Idiopathic Dilated Cardiomyopathy (IDC) an imbalance between myocardial oxygen consumption and supply has been postulated. The ensuing subclinical myocardial ischemia may contribute to progressive deterioration of LV function. beta-blocker is the therapy of choice in these patients. However, not all patients respond to the same extent. The aim of this study was to elucidate whether differences between responders and non-responders can be identified with respect to regional myocardial perfusion reserve (MPR) and contractile performance. METHODS: Patients with newly diagnosed IDC underwent Positron Emission Tomography (PET) scanning using both (13)N-ammonia as a perfusion tracer (baseline and dipyridamole stress), and (18)F-fluoro-deoxyglucose as a metabolism tracer, and a dobutamine stress MRI. MRI and PET were repeated 6 months after maximal beta-blocker therapy. MPR (assessed by PET) as well as wall motion score (WMS, assessed by MRI) were evaluated in a 17 segment-model. Functional response to beta-blocker therapy was assigned as a stable or improved LVEF or diminished LVEF. RESULTS: Sixteen patients were included (age 47.9 +/- 11.5 years; 12 males, LVEF 28.6 +/- 8.4%). Seven patients showed improved LVEF (9.7 +/- 3.1%), and nine patients did not show improved LVEF (-3.4 +/- 3.9%). MPR improved significantly in responders (1.56 +/- .23 to 1.93 +/- .49, P = .049), and MPR decreased in non-responders; however, not significantly (1.98 +/- .70 to 1.61 +/- .28, P = .064), but was significantly different between both groups (P = .017) after beta-blocker therapy. A significant correlation was found between change in perfusion reserve and change in LVEF: a decrease in perfusion reserve was associated with a decrease in LVEF and vice versa. Summed rest score of wall motion in responders improved from 26 to 21 (P = .022) whereas in non-responders no change was observed from 26 to 25) (P = ns). Summed stress score of wall motion in responders improved from 23 to 21 (P = .027) whereas in non-responders no change was observed from 27 to 26) (P = ns). CONCLUSION: In IDC patients, global as well as regional improvement after initiation of beta-blocker treatment is accompanied by an improvement in regional perfusion parameters. On the other hand in IDC patients with further left ventricular function deterioration after initiation of beta-blocker therapy this is accompanied by a decrease in perfusion reserve.


Asunto(s)
Antagonistas Adrenérgicos beta/uso terapéutico , Cardiomiopatía Dilatada/fisiopatología , Circulación Coronaria , Contracción Miocárdica , Función Ventricular Izquierda , Cardiomiopatía Dilatada/diagnóstico por imagen , Cardiomiopatía Dilatada/tratamiento farmacológico , Dipiridamol/farmacología , Femenino , Fluorodesoxiglucosa F18 , Humanos , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Miocardio/metabolismo , Consumo de Oxígeno , Tomografía de Emisión de Positrones , Radiofármacos
12.
J Comput Assist Tomogr ; 33(3): 317-27, 2009.
Artículo en Inglés | MEDLINE | ID: mdl-19478621

RESUMEN

This meta-analysis evaluates the diagnostic accuracy of multidetector computed tomography (MDCT) and magnetic resonance imaging (MRI) for bypass graft occlusion and stenosis detection compared with coronary angiography in post-coronary artery bypass graft patients. The indication for noninvasive imaging in post-coronary artery bypass graft patients with these techniques is discussed. Overall, MRI had significantly lower sensitivity (81%) and specificity (91%) for occlusion detection than MDCT (96% and 98%, respectively). Only 2 studies assessed the accuracy of stenosis detection with MRI. Stenosis detection with MDCT had a pooled sensitivity of 89% and specificity of 97%. Multidetector computed tomography is therefore superior to MRI for the noninvasive detection of coronary bypass graft occlusion and stenosis. For stenosis detection, the accuracy of MDCT is, however, not sufficient to warrant a wide clinical use. The remaining indication for MRI-guided bypass graft assessment is in combination with myocardial evaluation such as magnetic resonance perfusion, wall motion, and stress test as a "one-stop-shop" procedure.


Asunto(s)
Puente de Arteria Coronaria/estadística & datos numéricos , Oclusión Coronaria/diagnóstico , Oclusión Coronaria/epidemiología , Estenosis Coronaria/diagnóstico , Estenosis Coronaria/epidemiología , Angiografía por Resonancia Magnética/estadística & datos numéricos , Tomografía Computarizada por Rayos X/estadística & datos numéricos , Angiografía Coronaria/estadística & datos numéricos , Humanos , Incidencia , Complicaciones Posoperatorias/diagnóstico , Complicaciones Posoperatorias/epidemiología , Pronóstico , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Resultado del Tratamiento
13.
Eur J Radiol ; 70(1): 61-8, 2009 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-18308496

RESUMEN

PURPOSE: To assess the influence of temporal resolution on image quality of computed tomographic (CT) coronary angiography by comparing 64-row Dual Source CT (DSCT) and Single Source CT (SSCT) at different heart rates. METHODS: An anthropomorphic moving heart phantom was scanned at rest, and at 50 beats per minute (bpm) up to 110 bpm, with intervals of 10 bpm. 3D volume rendered images and curved multi-planar reconstructions (MPRs) were acquired and image quality of the coronary arteries was rated on a 5-points scale (1=poor image quality with many artefacts, 5=excellent image quality) for each heart rate and each scanner by 3 observers. Paired sample t-test and Wilcoxon Signed Ranks test were used to assess clinically relevant differences between both modalities. RESULTS: The mean image quality scores at 70, 100 and 110 bpm were significantly higher for DSCT compared to SSCT. The overall mean image quality scores for DSCT (4.2+/-0.6) and SSCT (3.0+/-1.1) also differed significantly (p<0.001). CONCLUSION: These initial results show a clinically relevant overall higher image quality for DSCT compared to SSCT, especially at heart rates of 70, 100 and 110 bpm. With its comparatively high image quality and low radiation dose, DSCT appears to be the method of choice in CT coronary angiography at heart rates above 70 bpm.


Asunto(s)
Artefactos , Angiografía Coronaria/métodos , Frecuencia Cardíaca , Intensificación de Imagen Radiográfica/métodos , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Tomografía Computarizada por Rayos X/métodos , Angiografía Coronaria/instrumentación , Humanos , Fantasmas de Imagen , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Tomografía Computarizada por Rayos X/instrumentación
14.
Neth Heart J ; 16(7-8): 270-1, 2008 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-18711617
15.
Eur Radiol ; 18(11): 2425-32, 2008 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-18651148

RESUMEN

The purpose of this study is to assess the capability of dual-source computed tomography (DSCT) in evaluating coronary artery anomalies. Early detection and evaluation of coronary artery anomalies is essential because of their potential association with myocardial ischemia and sudden death. In 16 patients (12 men, mean age 50 +/- 14 years), anomalous coronary arteries were detected on contrast-enhanced DSCT in a patient cohort of 230 individuals (incidence of 7%). Six different types of anomalies were diagnosed (three fistula, four anomalies of the circumflex artery, four anomalous right coronary arteries, three anomalies of the left coronary artery, one absent left main coronary artery, and one left coronary artery arising from the pulmonary trunk). Of the 16 patients, 10 also underwent conventional coronary angiography (CAG). Retrospective evaluation of the CAGs by an experienced interventional cardiologist resulted in a precise diagnosis in 50% of patients. With DSCT, sufficient image quality and exact visualization of the aberrant anatomy were achieved in all patients. Therefore, DSCT seems to be an accurate diagnostic tool for examining the precise origin, course, and shape of aberrant coronary arteries.


Asunto(s)
Angiografía Coronaria/métodos , Anomalías de los Vasos Coronarios/diagnóstico por imagen , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Tomografía Computarizada por Rayos X/métodos , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Intensificación de Imagen Radiográfica/métodos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
16.
Eur Radiol ; 18(9): 1800-8, 2008 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-18491099

RESUMEN

Therapy advice based on dual-source computed tomography (DSCT) in comparison with coronary angiography (CAG) was investigated and the results evaluated after 1-year follow-up. Thirty-three consecutive patients (mean age 61.9 years) underwent DSCT and CAG and were evaluated independently. In an expert reading (the "gold standard"), CAG and DSCT examinations were evaluated simultaneously by an experienced radiologist and cardiologist. Based on the presence of significant stenosis and current guidelines, therapy advice was given by all readers blinded from the results of other readings and clinical information. Patients were treated based on a multidisciplinary team evaluation including all clinical information. In comparison with the gold standard, CAG had a higher specificity (91%) and positive predictive value (PPV) (95%) compared with DSCT (82% and 91%, respectively). DSCT had a higher sensitivity (96%) and negative predictive value (NPV) (89%) compared with CAG (91% and 83%, respectively). The DSCT-based therapy advice did not lead to any patient being denied the revascularization they needed according to the multidisciplinary team evaluation. During follow-up, two patients needed additional revascularization. The high NPV for DSCT for revascularization assessment indicates that DSCT could be safely used to select patients benefiting from medical therapy only.


Asunto(s)
Angiografía Coronaria/métodos , Estenosis Coronaria/diagnóstico por imagen , Estenosis Coronaria/cirugía , Revascularización Miocárdica/métodos , Tomografía Computarizada por Rayos X/métodos , Adulto , Femenino , Humanos , Masculino , Selección de Paciente , Cuidados Preoperatorios/métodos , Pronóstico , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Cirugía Asistida por Computador/métodos
17.
Neth Heart J ; 15(1): 5-11, 2007 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-17612701

RESUMEN

BACKGROUND.: New developments have made 16-slice multidetector computed tomography (MDCT) a promising technique for detecting significant coronary stenoses. At present, there is a paucity of data on the relation between fractional flow reserve (FFR) measurement and MDCT stenosis detection. OBJECTIVE.: The aim of this study was to investigate the relation between the anatomical severity of coronary artery disease detected by MDCT and functional severity measured by fractional flow reserve (FFR). METHODS.: We studied 53 patients (39 men and 14 women, age 62.5+/-8.1 years) with single-vessel disease scheduled for percutaneous coronary intervention (PCI). All patients underwent MDCT scanning one day prior to PCI and FFR was measured before PCI in the target vessel. RESULTS.: MDCT analysis could be performed in 52 of 53 patients (98.1%) and all patients had adequate FFR and quantitative coronary angiography (QCA) measurements. The mean stenosis diameters calculated by MDCT and QCA were 67.0+/-11.6% and 60.8+/-11.6% respectively. No significant relation was found between MDCT and QCA (r=0.22, p=0.12) The mean FFR in all patients was 0.67+/-0.18. A relation of r=-0.46 (p=0.0006) between QCA and FFR was found. In contrast, no relation between MDCT and FFR could be demonstrated (r=-0.09, p=0.50). Furthermore, a high incidence of false-positive and false-negative findings was present in both diagnostic modalities. CONCLUSION.: There is no clear relation between the anatomical and functional severity of coronary artery disease as defined by MDCT and FFR. Therefore, functional assessment of coronary artery disease remains mandatory for clinical decisionmaking. (Neth Heart J 2007;15:5-11.).

18.
Int J Cardiovasc Imaging ; 23(3): 369-77, 2007 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-17086363

RESUMEN

PURPOSE: The purpose of this study is to assess the diagnostic accuracy of 64-MDCT in symptomatic patients after CABG and to explore the advantages of the 64-MDCT results on the CAG procedure. MATERIAL AND METHODS: From December 2004 until August 2005, 34 post-CABG patients (29 men, mean age 63.5 +/- 8.5 years) with 69 coronary artery bypass grafts were scanned on a 64-MDCT (Somatom Sensation 64, Siemens AG, Forchheim, Germany) prior to CAG. Angiograms and 64-MDCT images were evaluated for the existence of occlusions or significant stenosis (>or=50% lumen reduction) in bypass grafts and native coronary arteries. RESULTS: 64-MDCT had a sensitivity, a specificity, and a diagnostic accuracy of 100% for occlusion detection. For stenosis detection, sensitivity was 100%, specificity 98.7% and diagnostic accuracy 98.7%. For detecting significant stenosis in native coronary arteries, 64-MDCT had a sensitivity of 80.0%, specificity of 90.8%, and a diagnostic accuracy of 87.1%. Seventeen patients (50.0%) did not need invasive treatment, 14 patients (41.2%) underwent a percutaneous coronary intervention (PCI), and 3 patients (8.8%) underwent surgery. Treatment advice based on 64-MDCT was correct in 88.2% of patients and when 64-MDCT results would have been known 58.8% of diagnostic CAG procedures could have been prevented. CONCLUSION: In conclusion, 64-MDCT has a high diagnostic accuracy in detecting bypass graft stenosis and occlusions, and 64-MDCT based treatment advice was correct in 88.2% of patients.


Asunto(s)
Puente de Arteria Coronaria , Reestenosis Coronaria/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Anciano , Medios de Contraste , Angiografía Coronaria , Enfermedad Coronaria/diagnóstico por imagen , Enfermedad Coronaria/cirugía , Femenino , Humanos , Yopamidol/análogos & derivados , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Recurrencia , Sensibilidad y Especificidad
19.
Acta Radiol ; 47(10): 1049-57, 2006 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-17135007

RESUMEN

Cardiac morbidity and mortality are closely related to cardiac volumes and global left ventricular (LV) function, expressed as left ventricular ejection fraction. Accurate assessment of these parameters is required for the prediction of prognosis in individual patients as well as in entire cohorts. The current standard of reference for left ventricular function is analysis by short-axis magnetic resonance imaging. In recent years, major extensive technological improvements have been achieved in computed tomography. The most marked development has been the introduction of the multidetector CT (MDCT), which has significantly improved temporal and spatial resolutions. In order to assess the current status of MDCT for analysis of LV function, the current available literature on this subject was reviewed. The data presented in this review indicate that the global left ventricular functional parameters measured by contemporary multi-detector row systems combined with adequate reconstruction algorithms and post-processing tools show a narrow diagnostic window and are interchangeable with those obtained by MRI.


Asunto(s)
Imagen por Resonancia Magnética/métodos , Tomografía Computarizada por Rayos X/métodos , Disfunción Ventricular Izquierda/diagnóstico , Función Ventricular Izquierda/fisiología , Humanos , Pronóstico , Disfunción Ventricular Izquierda/diagnóstico por imagen , Disfunción Ventricular Izquierda/fisiopatología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...