Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 272
Filtrar
1.
Eur J Heart Fail ; 2024 May 10.
Artículo en Inglés | MEDLINE | ID: mdl-38726573

RESUMEN

AIM: This analysis aimed to compare the clinical outcomes associated with heart failure (HF) readmissions and to identify associations with HF hospitalizations (HFH) in patients treated with the MitraClip™ NTR/XTR System in the EXPAND study. METHODS AND RESULTS: The global, real-world EXPAND study enrolled 1041 patients with primary or secondary mitral regurgitation (MR) treated with the MitraClip NTR/XTR System. Echocardiograms were analysed by an independent echocardiographic core laboratory. The study population was stratified into HFH and No-HFH groups based on the occurrence of HFH 1 year post-index procedure. Clinical outcomes including MR severity, New York Heart Association (NYHA) functional class, Kansas City Cardiomyopathy Questionnaire (KCCQ) score, and all-cause mortality were compared (HFH: n = 181; No-HFH: n = 860). Both groups achieved consistent 1-year MR reduction to ≤1+ (HFH vs. No-HFH: 87.3% vs. 89.5%, p = 0.6) and significant 1-year improvement in KCCQ scores (+16.5 vs. +22.3, p = 0.09) and NYHA functional class. However, more patients in the No-HFH group had 1-year NYHA class ≤II (HFH vs. No-HFH: 67.9% vs. 81.9%, p < 0.01). All-cause mortality at 1 year was 36.8% in the HFH group versus 10.4% in the No-HFH group (p < 0.001). The HFH rate decreased by 63% at 1 year post-M-TEER versus 1 year pre-treatment (relative risk 0.4, p < 0.001). Independent HFH associations were MR ≥2+ at discharge, HFH 1 year prior to treatment, baseline NYHA class ≥III, baseline tricuspid regurgitation ≥2+, and baseline left ventricular ejection fraction ≤40%. CONCLUSIONS: This study reports the impact of HFH on clinical outcomes post-treatment in the EXPAND study. Results demonstrate that the occurrence of HFH was associated with worse 1-year survival, and treatment with the MitraClip system substantially reduced HFH and improved patient symptoms and quality of life.

2.
Artículo en Inglés | MEDLINE | ID: mdl-38599918

RESUMEN

BACKGROUND: The next generation supra-annular, self-expanding Evolut FX transcatheter aortic valve (TAV) system was designed to improve catheter deliverability, provide stable and symmetric valve deployment, and assess commissural alignment during the procedure. The impact of these modifications has not been clinically evaluated. METHODS: Procedural information was collected by survey in 2 Stages: Stage I comprised 23 centers with extensive experience with Evolut TAV systems, and Stage II comprised an additional 46 centers with a broad range of balloon- and self-expanding system experience. Operators were to compare the experience with the Evolut FX to the predicate Evolut PRO+ system. RESULTS: There were 285 cases during Stage I from June 24 to August 12, 2022, and 254 cases during Stage II from August 15 to September 11, 2022. Overall, the cusp overlap technique was used in 88.6 %, and commissural alignment was achieved in 96.1 % of these cases. Compared to implanter's previous experience with the Evolut PRO+ system, less resistance was noted with the Evolut FX system: in 83.0 % of cases during vascular insertion, in 84.7 % of cases while tracking through the vasculature, in 84.4 % of cases while traversing over the arch, and 76.1 % of cases in advancing across the valve. Better symmetry of valve depth was observed in 423 of 525 cases (80.6 %). CONCLUSION: Evolut FX system design modifications translated into improvements in catheter deliverability, deployment symmetry and stability, and commissural alignment as assessed by experienced self-expanding and balloon expandable operators.

3.
JACC Cardiovasc Interv ; 17(8): 1007-1016, 2024 Apr 22.
Artículo en Inglés | MEDLINE | ID: mdl-38573257

RESUMEN

BACKGROUND: Data on valve reintervention after transcatheter aortic valve replacement (TAVR) or surgical aortic valve replacement (SAVR) are limited. OBJECTIVES: The authors compared the 5-year incidence of valve reintervention after self-expanding CoreValve/Evolut TAVR vs SAVR. METHODS: Pooled data from CoreValve and Evolut R/PRO (Medtronic) randomized trials and single-arm studies encompassed 5,925 TAVR (4,478 CoreValve and 1,447 Evolut R/PRO) and 1,832 SAVR patients. Reinterventions were categorized by indication, timing, and treatment. The cumulative incidence of reintervention was compared between TAVR vs SAVR, Evolut vs CoreValve, and Evolut vs SAVR. RESULTS: There were 99 reinterventions (80 TAVR and 19 SAVR). The cumulative incidence of reintervention through 5 years was higher with TAVR vs SAVR (2.2% vs 1.5%; P = 0.017), with differences observed early (≤1 year; adjusted subdistribution HR: 3.50; 95% CI: 1.53-8.02) but not from >1 to 5 years (adjusted subdistribution HR: 1.05; 95% CI: 0.48-2.28). The most common reason for reintervention was paravalvular regurgitation after TAVR and endocarditis after SAVR. Evolut had a significantly lower incidence of reintervention than CoreValve (0.9% vs 1.6%; P = 0.006) at 5 years with differences observed early (adjusted subdistribution HR: 0.30; 95% CI: 0.12-0.73) but not from >1 to 5 years (adjusted subdistribution HR: 0.61; 95% CI: 0.21-1.74). The 5-year incidence of reintervention was similar for Evolut vs SAVR (0.9% vs 1.5%; P = 0.41). CONCLUSIONS: A low incidence of reintervention was observed for CoreValve/Evolut R/PRO and SAVR through 5 years. Reintervention occurred most often at ≤1 year for TAVR and >1 year for SAVR. Most early reinterventions were with the first-generation CoreValve and managed percutaneously. Reinterventions were more common following CoreValve TAVR compared with Evolut TAVR or SAVR.


Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Complicaciones Posoperatorias , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Prótesis Valvulares Cardíacas , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Complicaciones Posoperatorias/cirugía , Diseño de Prótesis , Ensayos Clínicos Controlados Aleatorios como Asunto , Medición de Riesgo , Factores de Riesgo , Índice de Severidad de la Enfermedad , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Resultado del Tratamiento , Incidencia , Retratamiento
4.
J Surg Res ; 295: 385-392, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38070251

RESUMEN

INTRODUCTION: The membranous septum (MS) length measured by cardiac computed tomography (CT) is useful for the prediction of permanent pacemaker implantation (PPMI) and new left bundle branch block (LBBB) after transcatheter aortic valve replacement. However, its predictive value for patients undergoing surgical aortic valve replacement (SAVR) is unknown. METHODS: A total of 2531 consecutive patients were registered in the institutional Society of Thoracic Surgeons database between July 2017 and June 2020. Patients who underwent non-SAVR procedures, had prior pacemaker/implantable cardioverter defibrillator, prior SAVR, no preprocedural CT assessment, or suboptimal CT imaging were excluded. RESULTS: A total of 126 SAVR with preprocedural CT assessment were analyzed. Bicuspid aortic valve morphology was confirmed on CT in 59.5% of patients. There were three new PPMIs and five new LBBBs observed after SAVR at the time of discharge. In-hospital mortality was 0.8%. Low left ventricular (LV) ejection fraction (<50%), LV mass index >120 g/m2, large right coronary artery height, and MS length <1.5 mm predicted new PPMI/LBBB. Multivariate analysis showed LV mass index >120 g/m2 (odds ratio: 9.165; 95% confidence interval: 1.644-51.080; P = 0.011) and MS length <1.5 mm (odds ratio: 14.449; 95% confidence interval: 1.632-127.954; P = 0.016) were independent predictors for new PPMI/LBBB. CONCLUSIONS: Short MS length on preoperative cardiac CT is a powerful and novel predictor for the risk of new PPMI/LBBB after SAVR. Special care should be taken in patients with short MS length to avoid suture-mediated trauma.


Asunto(s)
Estenosis de la Válvula Aórtica , Marcapaso Artificial , Humanos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Factores de Riesgo , Resultado del Tratamiento , Arritmias Cardíacas , Bloqueo de Rama/terapia
5.
Ann Thorac Surg ; 117(1): 87-94, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37806334

RESUMEN

BACKGROUND: The benefits of fast-track extubation in the intensive care unit (ICU) after cardiac surgery are well established. Although extubation in the operating room (OR) is safe in carefully selected patients, widespread use of this strategy in cardiac surgery remains unproven. This study was designed to evaluate perioperative outcomes with OR vs ICU extubation in patients undergoing nonemergency, isolated coronary artery bypass grafting (CABG). METHODS: The Society of Thoracic Surgeons (STS) data for all single-center patients who underwent nonemergency isolated CABG over a 6-year interval were analyzed. Perioperative morbidity and mortality with ICU vs OR extubation were compared. RESULTS: Between January 1, 2017 and December 31, 2022, 1397 patients underwent nonemergency, isolated CABG; 891 (63.8%) of these patients were extubated in the ICU, and 506 (36.2%) were extubated in the OR. Propensity matching resulted in 414 pairs. In the propensity-matched cohort, there were no differences between the 2 groups in incidence of reintubation, reoperation for bleeding, total operative time, stroke or transient ischemic attack, renal failure, or 30-day mortality. OR-extubated patients had shorter ICU hours (14 hours vs 20 hours; P < .0001), shorter postoperative hospital length of stay (3 days vs 5 days; P < .0001), a greater likelihood of being discharged directly to home (97.3% vs 89.9%; P < .0001), and a lower 30-day readmission rate (1.7% vs 4.1%; P = .04). CONCLUSIONS: Routine extubation in the OR is a feasible and safe strategy for a broad spectrum of patients after nonemergency CABG, with no increase in perioperative morbidity or mortality. Wider adoption of routine OR extubation for nonemergency CABG is indicated.


Asunto(s)
Extubación Traqueal , Quirófanos , Humanos , Extubación Traqueal/métodos , Tiempo de Internación , Estudios Retrospectivos , Puente de Arteria Coronaria
6.
JACC Case Rep ; 23: 101992, 2023 Oct 04.
Artículo en Inglés | MEDLINE | ID: mdl-37954954

RESUMEN

Coronary artery obstruction caused by sinus sequestration is well described after transcatheter aortic valve implantation in failed bioprosthetic valves, which usually occurs during or shortly after the transcatheter aortic valve implantation procedure. We report the presentation, management, and outcomes of 2 cases of very late sinus sequestration in native aortic annuli, which has not been described before to our knowledge. (Level of Difficulty: Advanced.).

7.
JACC Cardiovasc Interv ; 16(23): 2820-2832, 2023 Dec 11.
Artículo en Inglés | MEDLINE | ID: mdl-37905772

RESUMEN

BACKGROUND: Favorable 6-month outcomes from the CLASP IID Registry (Edwards PASCAL transcatheter valve repair system pivotal clinical trial) demonstrated that mitral valve transcatheter edge-to-edge repair with the PASCAL transcatheter valve repair system is safe and beneficial for treating prohibitive surgical risk degenerative mitral regurgitation (DMR) patients with complex mitral valve anatomy. OBJECTIVES: The authors sought to assess 1-year safety, echocardiographic and clinical outcomes from the CLASP IID Registry. METHODS: Patients with 3+ or 4+ DMR who were at prohibitive surgical risk, had complex mitral valve anatomy based on the MitraClip Instructions for Use, and deemed suitable for treatment with the PASCAL system were enrolled prospectively. Safety, clinical, echocardiographic, functional, and quality-of-life outcomes were assessed at 1 year. Study oversight included a central screening committee, echocardiographic core laboratory, and clinical events committee. RESULTS: Ninety-eight patients were enrolled. One-year Kaplan-Meier (KM) estimates of freedom from composite major adverse events, all-cause mortality, and heart failure hospitalization were 83.5%, 89.3%, and 91.5%, respectively. Significant mitral regurgitation (MR) reduction was achieved at 1 year (P < 0.001 vs baseline) including 93.2% at MR ≤2+ and 57.6% at MR ≤1+ with improvements in related echocardiographic measures. NYHA functional class and Kansas City Cardiomyopathy Questionnaire score also improved significantly (P < 0.001 vs baseline). CONCLUSIONS: At 1 year, treatment with the PASCAL system demonstrated safety and significant MR reduction, with continued improvement in clinical, echocardiographic, functional, and quality-of-life outcomes, illustrating the value of the PASCAL system in the treatment of prohibitive surgical risk patients with 3+ or 4+ DMR and complex mitral valve anatomy.


Asunto(s)
Cateterismo Cardíaco , Insuficiencia de la Válvula Mitral , Humanos , Cateterismo Cardíaco/efectos adversos , Ecocardiografía , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Resultado del Tratamiento , Ensayos Clínicos como Asunto
8.
JACC Cardiovasc Interv ; 16(21): 2600-2610, 2023 11 13.
Artículo en Inglés | MEDLINE | ID: mdl-37877913

RESUMEN

BACKGROUND: The fourth-generation mitral transcatheter edge-to-edge repair (M-TEER) device introduced an improved clip deployment sequence, independent leaflet grasping, and 2 wider clip sizes to tailor the treatment of patients with mitral regurgitation (MR) for a broad range of anatomies. The 30-day safety and effectiveness of the fourth-generation M-TEER device were previously demonstrated. OBJECTIVES: The aim of this study was to evaluate 1-year outcomes in a contemporary, real-world cohort of subjects treated with the MitraClip G4 system. METHODS: EXPAND G4 is an ongoing prospective, multicenter, international, single-arm study that enrolled subjects with primary and secondary MR. One-year outcomes included MR severity (echocardiographic core laboratory assessed), heart failure hospitalization, all-cause mortality, functional capacity (NYHA functional class), and quality of life (Kansas City Cardiomyopathy Questionnaire). RESULTS: A total of 1,164 subjects underwent M-TEER from 2020 to 2022. At 1 year, there was a durable reduction in MR to mild or less in 92.6% and to none or trace in 44.2% (P < 0.0001 vs baseline). Few subjects had major adverse events through 1 year (<2% for myocardial infarction, surgical reintervention, or single-leaflet device attachment). The 1-year Kaplan-Meier estimates for all-cause mortality and heart failure hospitalization were 12.3% and 16.9%. Significant improvements in functional capacity (NYHA functional class I or II in 82%; P < 0.0001 vs baseline) and quality of life (18.5-point Kansas City Cardiomyopathy Questionnaire overall summary score improvement; P < 0.0001) were observed. CONCLUSIONS: M-TEER with the fourth-generation M-TEER device was safe and effective at 1 year, with durable reductions in MR severity to ≤1+ in more than 90% of patients and concomitant improvements in functional status and quality of life.


Asunto(s)
Cardiomiopatías , Insuficiencia Cardíaca , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Humanos , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Calidad de Vida , Estudios Prospectivos , Resultado del Tratamiento , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía
9.
J Am Coll Cardiol ; 82(2): 109-123, 2023 07 11.
Artículo en Inglés | MEDLINE | ID: mdl-37407110

RESUMEN

BACKGROUND: Previous studies demonstrated transcatheter aortic valve replacement (TAVR) with an earlier generation balloon-expandable valve to be noninferior to surgical aortic valve replacement (SAVR) for death and disabling stroke in intermediate-risk patients with symptomatic, severe aortic stenosis at 5 years. However, limited long-term data are available with the more contemporary SAPIEN 3 (S3) bioprosthesis. OBJECTIVES: The aim of this study was to compare 5-year risk-adjusted outcomes in intermediate-risk patients undergoing S3 TAVR vs SAVR. METHODS: Propensity score matching was performed to account for baseline differences in intermediate-risk patients undergoing S3 TAVR in the PARTNER 2 (Placement of Aortic Transcatheter Valves) S3 single-arm study and SAVR in the PARTNER 2A randomized clinical trial. The primary composite endpoint consisted of 5-year all-cause death and disabling stroke. RESULTS: A total of 783 matched pairs of intermediate-risk patients with severe aortic stenosis were studied. There were no differences in the primary endpoint between S3 TAVR and SAVR at 5 years (40.2% vs 42.7%; HR: 0.87; 95% CI: 0.74-1.03; P = 0.10). The incidence of mild or greater paravalvular regurgitation was more common after S3 TAVR. There were no differences in structural valve deterioration-related stage 2 and 3 hemodynamic valve deterioration or bioprosthetic valve failure. CONCLUSIONS: In this propensity-matched analysis of intermediate-risk patients, 5-year rates of death and disabling stroke were similar between S3 TAVR and SAVR. Rates of structural valve deterioration-related hemodynamic valve deterioration were similar, but paravalvular regurgitation was more common after S3 TAVR. Longer-term follow-up is needed to further evaluate differences in late adverse clinical events and bioprosthetic valve durability. (PII S3i [PARTNER II Trial: Placement of Aortic Transcatheter Valves II - S3 Intermediate], NCT03222128; PII A (PARTNER II Trial: Placement of Aortic Transcatheter Valves II - XT Intermediate and High Risk], NCT01314313).


Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Accidente Cerebrovascular , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/etiología , Resultado del Tratamiento , Instrumentos Quirúrgicos , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/cirugía
10.
JACC Cardiovasc Interv ; 16(12): 1463-1473, 2023 06 26.
Artículo en Inglés | MEDLINE | ID: mdl-37380228

RESUMEN

BACKGROUND: The fourth-generation MitraClip G4 System builds on the previous NTR/XTR system with additional wider clip sizes (NTW and XTW), an independent grasping feature, and an improved clip deployment sequence. OBJECTIVES: The primary objective of this study was to assess the safety and performance of the MitraClip G4 System within a contemporary real-world setting. METHODS: EXPAND G4 is a prospective, multicenter, international, single-arm, postapproval study that enrolled patients with primary (degenerative) mitral regurgitation (MR) and secondary (functional) MR at 60 centers. Follow-up of the full cohort has been conducted through 30 days. Echocardiograms were analyzed by an echocardiography core laboratory. Study outcomes included MR severity, functional capacity measured by NYHA functional class, quality of life measured using the Kansas City Cardiomyopathy Questionnaire, major adverse event rates, and all-cause mortality. RESULTS: In EXPAND G4, 1,141 subjects with primary MR and secondary MR were treated from March 2021 to February 2022. Implantation and acute procedural success rates were 98.0% and 96.2%, respectively, with a mean of 1.4 ± 0.6 clips implanted per subject. MR was significantly reduced at 30 days compared with baseline (98% achieved MR ≤ 2+, and 91% achieved MR ≤ 1+; P < 0.0001). Functional capacity and quality of life were substantially improved, with 83% of patients achieving NYHA functional class I or II. Likewise, an 18-point improvement was observed in Kansas City Cardiomyopathy Questionnaire summary scores compared with baseline. The composite major adverse event rate was 2.7%, and the all-cause death rate was 1.3% at 30 days. CONCLUSIONS: This study demonstrates for the first time the effectiveness and safety of MitraClip G4 System at 30 days in a cohort of >1,000 patients with MR in a contemporary, real-world setting.


Asunto(s)
Cardiomiopatías , Insuficiencia de la Válvula Mitral , Humanos , Estudios Prospectivos , Calidad de Vida , Resultado del Tratamiento , Ecocardiografía , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía
11.
JACC Cardiovasc Interv ; 16(12): 1474-1485, 2023 06 26.
Artículo en Inglés | MEDLINE | ID: mdl-37380229

RESUMEN

BACKGROUND: Anatomical and clinical criteria to define mitral transcatheter edge-to-edge repair (TEER) "unsuitability" have been proposed on the basis of a Heart Valve Collaboratory consensus opinion from physician experience with early-generation TEER devices but lacked an evidence-based approach. OBJECTIVES: The aim of this study was to explore the spectrum of TEER suitability using echocardiographic and clinical outcomes from the EXPAND G4 real-world postapproval study. METHODS: EXPAND G4 is a global, prospective, multicenter, single-arm study that enrolled 1,164 subjects with mitral regurgitation (MR) treated with the MitraClip G4 System. Three groups were defined using the Heart Valve Collaboratory TEER unsuitability criteria: 1) risk of stenosis (RoS); 2) risk of inadequate MR reduction (RoIR); and 3) subjects with baseline moderate or less MR (MMR). A TEER-suitable (TS) group was defined by the absence of these characteristics. Endpoints included independent core laboratory-assessed echocardiographic characteristics, procedural outcomes, MR reduction, NYHA functional class, Kansas City Cardiomyopathy Questionnaire score, and major adverse events through 30 days. RESULTS: Subjects in the RoS (n = 56), RoIR (n = 54), MMR (n = 326), and TS (n = 303) groups had high 30-day MR reduction rates (≤1+: RoS 97%, MMR 93%, and TS 91%; ≤2+: RoIR 94%). Thirty-day improvements in functional capacity (NYHA functional class I or II at 30 days vs baseline: RoS 94% vs 29%, RoIR 88% vs 30%, MMR 79% vs 26%, and TS 83% vs 33%) and quality of life (change in Kansas City Cardiomyopathy Questionnaire score: RoS +27 ± 26, RoIR +16 ± 26, MMR +19 ± 26, and TS +19 ± 24) were safely achieved in all groups, with low major adverse events (<3%) and all-cause mortality (RoS 1.8%, RoIR 0%, MMR 1.5%, and TS 1.3%). CONCLUSIONS: Patients previously deemed TEER unsuitable can be safely and effectively treated with the mitral TEER fourth-generation device.


Asunto(s)
Cardiomiopatías , Insuficiencia de la Válvula Mitral , Humanos , Estudios Prospectivos , Calidad de Vida , Especies Reactivas de Oxígeno , Resultado del Tratamiento , Constricción Patológica , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía
12.
Circulation ; 147(21): 1594-1605, 2023 05 23.
Artículo en Inglés | MEDLINE | ID: mdl-37154049

RESUMEN

BACKGROUND: In patients with severe symptomatic aortic stenosis at low surgical risk, transfemoral transcatheter aortic valve replacement (TAVR) with the SAPIEN 3 valve has been shown to reduce the composite of death, stroke, or rehospitalization at 2-year follow-up compared with surgical aortic valve replacement (SAVR). Whether TAVR is cost-effective compared with SAVR for low-risk patients remains uncertain. METHODS: Between 2016 and 2017, 1000 low-risk patients with aortic stenosis were randomly assigned to TAVR with the SAPIEN 3 valve or SAVR in the PARTNER 3 trial (Placement of Aortic Transcatheter Valves). Of these patients, 929 underwent valve replacement, were enrolled in the United States, and were included in the economic substudy. Procedural costs were estimated using measured resource use. Other costs were determined by linkage with Medicare claims or by regression models when linkage was not feasible. Health utilities were estimated using the EuroQOL 5-item questionnaire. With the use of a Markov model informed by in-trial data, lifetime cost-effectiveness from the perspective of the US health care system was estimated in terms of cost per quality-adjusted life-year gained. RESULTS: Although procedural costs were nearly $19 000 higher with TAVR, total index hospitalization costs were only $591 more with TAVR compared with SAVR. Follow-up costs were lower with TAVR such that TAVR led to 2-year cost savings of $2030/patient compared with SAVR (95% CI, -$6222 to $1816) and a gain of 0.05 quality-adjusted life-years (95% CI, -0.003 to 0.102). In our base-case analysis, TAVR was projected to be an economically dominant strategy with a 95% probability that the incremental cost-effectiveness ratio for TAVR would be <$50 000/quality-adjusted life-year gained (consistent with high economic value from a US health care perspective). These findings were sensitive to differences in long-term survival, however, such that a modest long-term survival advantage with SAVR would render SAVR cost-effective (although not cost saving) compared with TAVR. CONCLUSIONS: For patients with severe aortic stenosis and low surgical risk similar to those enrolled in the PARTNER 3 trial, transfemoral TAVR with the SAPIEN 3 valve is cost saving compared with SAVR at 2 years and is projected to be economically attractive in the long run as long as there are no substantial differences in late death between the 2 strategies. Long-term follow-up will be critical to ultimately determine the preferred treatment strategy for low-risk patients from both a clinical and economic perspective.


Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Anciano , Estados Unidos , Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Resultado del Tratamiento , Medicare , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Factores de Riesgo
13.
J Am Coll Cardiol ; 81(18): 1766-1776, 2023 05 09.
Artículo en Inglés | MEDLINE | ID: mdl-37137586

RESUMEN

BACKGROUND: Surgical management of isolated tricuspid regurgitation (TR) is associated with high morbidity and mortality, thereby creating a significant need for a lower-risk transcatheter solution. OBJECTIVES: The single-arm, multicenter, prospective CLASP TR (Edwards PASCAL TrAnScatheter Valve RePair System in Tricuspid Regurgitation [CLASP TR] Early Feasibility Study) evaluated 1-year outcomes of the PASCAL transcatheter valve repair system (Edwards Lifesciences) to treat TR. METHODS: Study inclusion required a previous diagnosis of severe or greater TR and persistent symptoms despite medical treatment. An independent core laboratory evaluated echocardiographic results, and a clinical events committee adjudicated major adverse events. The study evaluated primary safety and performance outcomes, with echocardiographic, clinical, and functional endpoints. Study investigators report 1-year all-cause mortality and heart failure hospitalization rates. RESULTS: Sixty-five patients were enrolled: mean age of 77.4 years; 55.4% female; and 97.0% with severe to torrential TR. At 30 days, cardiovascular mortality was 3.1%, the stroke rate was 1.5%, and no device-related reinterventions were reported. Between 30 days and 1 year, there were an additional 3 cardiovascular deaths (4.8%), 2 strokes (3.2%), and 1 unplanned or emergency reintervention (1.6%). One-year postprocedure, TR severity significantly reduced (P < 0.001), with 31 of 36 (86.0%) patients achieving moderate or less TR; 100% had at least 1 TR grade reduction. Freedom from all-cause mortality and heart failure hospitalization by Kaplan-Meier analyses were 87.9% and 78.5%, respectively. Their New York Heart Association functional class significantly improved (P < 0.001) with 92% in class I or II, 6-minute walk distance increased by 94 m (P = 0.014), and overall Kansas City Cardiomyopathy Questionnaire scores improved by 18 points (P < 0.001). CONCLUSIONS: The PASCAL system demonstrated low complication and high survival rates, with significant and sustained improvements in TR, functional status, and quality of life at 1 year. (Edwards PASCAL TrAnScatheter Valve RePair System in Tricuspid Regurgitation [CLASP TR] Early Feasibility Study [CLASP TR EFS]; NCT03745313).


Asunto(s)
Insuficiencia Cardíaca , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Tricúspide , Humanos , Femenino , Anciano , Masculino , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Estudios Prospectivos , Calidad de Vida , Resultado del Tratamiento , Cateterismo Cardíaco/métodos , Índice de Severidad de la Enfermedad
14.
JACC Cardiovasc Interv ; 16(5): 589-602, 2023 03 13.
Artículo en Inglés | MEDLINE | ID: mdl-36922046

RESUMEN

BACKGROUND: The third-generation MitraClip NTR/XTR transcatheter edge-to-edge repair system was introduced to assist in leaflet grasping with the longer clip arms of MitraClip XTR and to improve ease of use with the modified delivery catheter. OBJECTIVES: The EXPAND study evaluated contemporary real-world outcomes in subjects with mitral regurgitation (MR) treated with the third-generation MitraClip NTR/XTR transcatheter edge-to-edge repair system. METHODS: EXPAND is a prospective, multicenter, international, single-arm study that enrolled patients with primary MR and secondary MR at 57 centers. Follow-up was conducted through 12 months. Echocardiograms were analyzed by an echocardiographic core laboratories. Study outcomes included: MR severity, functional capacity measured by New York Heart Association functional class, quality of life measured by Kansas City Cardiomyopathy Questionnaire, heart failure hospitalizations, all-cause mortality. RESULTS: 1,041 patients were enrolled from April 2018 through March 2019, of which 50.5% had primary or mixed etiology. Implant success was 98.9%; 1.5 ± 0.6 clips were implanted per subject. Significant MR reduction from baseline (≥MR 3+: 56.0%) to 30 days (≤MR 1+:88.8%) was maintained through 1 year (MR ≤1+: 89.2%). A total of 84.5% and 93.0% of subjects in primary MR and secondary MR, respectively, had ≤1+ MR at 1 year. Significant improvements were observed in clinical outcomes (New York Heart Association functional class I/II in 80.3%, +21.6 improvement in Kansas City Cardiomyopathy Questionnaire score) at 1 year. All-cause mortality and heart failure hospitalizations at 1 year were 14.9% and 18.9%, respectively, which was significantly lower than previous studies. CONCLUSIONS: The study demonstrates treatment with the third-generation system resulted in substantial reduction of MR in a contemporary real-world practice, compared with the results of earlier EVEREST and COAPT trials.(The MitraClip® EXPAND Study of the Next Generation of MitraClip® Devices [EXPAND]; NCT03502811).


Asunto(s)
Cardiomiopatías , Insuficiencia Cardíaca , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Humanos , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Resultado del Tratamiento , Calidad de Vida , Estudios Prospectivos , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/etiología , Insuficiencia Cardíaca/diagnóstico por imagen , Insuficiencia Cardíaca/terapia , Insuficiencia Cardíaca/complicaciones , Cateterismo Cardíaco , Cardiomiopatías/complicaciones
15.
Glob Chang Biol ; 29(10): 2759-2775, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-36799318

RESUMEN

Large across-model spread in simulating land carbon (C) dynamics has been ubiquitously demonstrated in model intercomparison projects (MIPs), and became a major impediment in advancing climate change prediction. Thus, it is imperative to identify underlying sources of the spread. Here, we used a novel matrix approach to analytically pin down the sources of across-model spread in transient peatland C dynamics in response to a factorial combination of two atmospheric CO2 levels and five temperature levels. We developed a matrix-based MIP by converting the C cycle module of eight land models (i.e., TEM, CENTURY4, DALEC2, TECO, FBDC, CASA, CLM4.5 and ORCHIDEE) into eight matrix models. While the model average of ecosystem C storage was comparable to the measurement, the simulation differed largely among models, mainly due to inter-model difference in baseline C residence time. Models generally overestimated net ecosystem production (NEP), with a large spread that was mainly attributed to inter-model difference in environmental scalar. Based on the sources of spreads identified, we sequentially standardized model parameters to shrink simulated ecosystem C storage and NEP to almost none. Models generally captured the observed negative response of NEP to warming, but differed largely in the magnitude of response, due to differences in baseline C residence time and temperature sensitivity of decomposition. While there was a lack of response of NEP to elevated CO2 (eCO2 ) concentrations in the measurements, simulated NEP responded positively to eCO2 concentrations in most models, due to the positive responses of simulated net primary production. Our study used one case study in Minnesota peatland to demonstrate that the sources of across-model spreads in simulating transient C dynamics can be precisely traced to model structures and parameters, regardless of their complexity, given the protocol that all the matrix models were driven by the same gross primary production and environmental variables.


Asunto(s)
Carbono , Ecosistema , Dióxido de Carbono , Cambio Climático , Simulación por Computador
16.
J Am Heart Assoc ; 12(4): e027504, 2023 02 21.
Artículo en Inglés | MEDLINE | ID: mdl-36752231

RESUMEN

Background The current standard of care for the treatment of patients with primary mitral regurgitation (MR) is surgical mitral valve repair. Transcatheter edge-to-edge repair with the MitraClip device provides a less invasive treatment option for patients with both primary and secondary MR. Worldwide, >150 000 patients have been treated with the MitraClip device. However, in the United States, MitraClip is approved for use only in primary patients with MR who are at high or prohibitive risk for mitral valve surgery. The REPAIR MR (Percutaneous MitraClip Device or Surgical Mitral Valve Repair in Patients With Primary Mitral Regurgitation Who Are Candidates for Surgery) trial is designed to compare early and late outcomes associated with transcatheter edge-to-edge repair with the MitraClip and surgical repair of primary MR in older or moderate surgical risk patients. Methods and Results The REPAIR MR trial is a prospective, randomized, parallel-controlled, open-label multicenter, noninferiority trial for the treatment of severe primary MR (verified by an independent echocardiographic core laboratory). Patients with severe MR and indications for surgery because of symptoms (New York Heart Association class II-IV), or without symptoms with left ventricular ejection fraction ≤60%, pulmonary artery systolic pressure >50 mm Hg, or left ventricular end-systolic diameter ≥40 mm are eligible for the trial provided they meet the moderate surgical risk criteria as follows: (1) ≥75 years of age, or (2) if <75 years of age, then the subject has a Society of Thoracic Surgeons Predicted Risk Of Mortality score of ≥2% for mitral repair (or Society of Thoracic Surgeons replacement score of ≥4%), or the presence of a comorbidity that may introduce a surgery-specific risk. The local surgeon must determine that the mitral valve can be surgically repaired. Additionally, an independent eligibility committee will confirm that the MR can be reduced to mild or less with both the MitraClip and surgical mitral valve repair with a high degree of certainty. A total of 500 eligible subjects will be randomized in a 1:1 ratio to receive the MitraClip device or to undergo surgical mitral valve repair (control group). There are 2 co-primary end points for the trial, both of which will be evaluated at 2 years. Each subject will be followed for 10 years after enrollment. The study has received approval from both the Food and Drug Administration and the Centers for Medicare and Medicaid Services, and enrolled its first subject in July 2020. Conclusions The REPAIR MR trial will determine the safety and effectiveness of transcatheter edge-to-edge repair with the MitraClip in patients with primary MR who are at moderate surgical risk and are candidates for surgical MV repair. The trial will generate contemporary comparative clinical evidence for the MitraClip device and surgical MV repair. Registration https://clinicaltrials.gov/ct2/show/NCT04198870; NCT04198870.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Humanos , Anciano , Estados Unidos , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/etiología , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Volumen Sistólico , Estudios Prospectivos , Resultado del Tratamiento , Función Ventricular Izquierda , Medicare , Implantación de Prótesis de Válvulas Cardíacas/métodos , Cateterismo Cardíaco/efectos adversos
17.
Curr Cardiol Rep ; 25(3): 97-107, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36680732

RESUMEN

PURPOSE OF REVIEW: Percutaneous structural interventions have provided patients with an effective therapeutic option, and its growth has been aided by echocardiography. We describe the vital role that transesophageal echocardiography (TEE) plays in screening patients prior to their procedure. RECENT FINDINGS: A multimodality imaging approach is employed by the valve team, but TEE plays a unique role in diagnosis and planning. Utilization of all TEE views and features such as biplane, 3D imaging, and multiplanar reconstruction ensures accurate assessment of the structural lesion of interest. The role of TEE remains essential in the planning of structural interventions, and these studies should be performed in a systematic and comprehensive manner.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Ecocardiografía Tridimensional , Humanos , Ecocardiografía Transesofágica/métodos , Ecocardiografía Tridimensional/métodos , Imagen Multimodal
18.
Eur J Heart Fail ; 25(3): 411-421, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36597850

RESUMEN

AIMS: Mitral valve transcatheter edge-to-edge repair is a guideline-recommended treatment option for patients with secondary mitral regurgitation (SMR). The purpose of this analysis was to report contemporary real-world outcomes in SMR patients treated with third-generation MitraClip systems. METHODS AND RESULTS: EXPAND is a prospective, multicentre, international, single-arm study with 1041 patients treated for mitral regurgitation (MR) with MitraClip NTR/XTR, with 30-day and 1-year follow-up. All echocardiograms were analysed by an independent echocardiographic core lab. Study outcomes included procedural outcomes, durability of MR reduction, and major adverse events including all-cause mortality and heart failure hospitalizations (HFH). A subgroup of 413 symptomatic patients (age 74.7 ± 10.1 years, 58% male) with severe SMR were included. MR reduction to MR ≤ 1+ and MR ≤ 2+ was achieved in 93.0% and 98.5% of patients, respectively, which was sustained at 1-year follow-up. All-cause mortality was 17.7% at 1-year- follow-up, and the combined endpoint of all-cause mortality or first HFH occurred in 34% of patients. This combined endpoint was significantly less frequently observed in MR ≤ 1+ patients (Kaplan-Maier estimates: 29.7% vs. 69.6% for MR ≤ 1+ vs. MR ≥ 2 +; p < 0.0001). New York Heart Association (NYHA) functional class improved significantly from baseline (NYHA ≤ II: 17%) to 1-year follow-up (NYHA ≤ II: 78%) (p < 0.0001). While MR reduction was comparable between NTR-only vs. XTR-only treated patients, less XTR clips were required for achieving MR reduction. CONCLUSIONS: Under real-world conditions, optimal sustained MR reduction to MR ≤ 1+ was achieved in a high percentage of patients with third-generation MitraClip, which translated into symptomatic improvement and low event rates. These results appear to be comparable with recent randomized clinical trials.


Asunto(s)
Insuficiencia Cardíaca , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Humanos , Masculino , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Femenino , Insuficiencia de la Válvula Mitral/cirugía , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Estudios Prospectivos , Resultado del Tratamiento , Cateterismo Cardíaco
19.
Glob Chang Biol ; 29(8): 2046-2049, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36703026

RESUMEN

The perception of greater impact via new sinks, as opposed to through avoided emissions, has already led some large investors to focus on sink-related projects. This is a flawed perception when applied universally and carries a risk that effective routes to mitigation through avoiding emissions are side-lined. In reality, both emissions avoidance and emissions removal are needed, and both can be a cost-effective means of delivering mitigation.


Asunto(s)
Clima , Efecto Invernadero , Cambio Climático
20.
Glob Chang Biol ; 29(8): 2256-2273, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36560840

RESUMEN

Accurate estimation and forecasts of net biome CO2 exchange (NBE) are vital for understanding the role of terrestrial ecosystems in a changing climate. Prior efforts to improve NBE predictions have predominantly focused on increasing models' structural realism (and thus complexity), but parametric error and uncertainty are also key determinants of model skill. Here, we investigate how different parameterization assumptions propagate into NBE prediction errors across the globe, pitting the traditional plant functional type (PFT)-based approach against a novel top-down, machine learning-based "environmental filtering" (EF) approach. To do so, we simulate these contrasting methods for parameter assignment within a flexible model-data fusion framework of the terrestrial carbon cycle (CARDAMOM) at a global scale. In the PFT-based approach, model parameters from a small number of select locations are applied uniformly within regions sharing similar land cover characteristics. In the EF-based approach, a pixel's parameters are predicted based on underlying relationships with climate, soil, and canopy properties. To isolate the role of parametric from structural uncertainty in our analysis, we benchmark the resulting PFT-based and EF-based NBE predictions with estimates from CARDAMOM's Bayesian optimization approach (whereby "true" parameters consistent with a suite of data constraints are retrieved on a pixel-by-pixel basis). When considering the mean absolute error of NBE predictions across time, we find that the EF-based approach matches or outperforms the PFT-based approach at 55% of pixels-a narrow majority. However, NBE estimates from the EF-based approach are susceptible to compensation between errors in component flux predictions and predicted parameters can align poorly with the assumed "true" values. Overall, though, the EF-based approach is comparable to conventional approaches and merits further investigation to better understand and resolve these limitations. This work provides insight into the relationship between terrestrial biosphere model performance and parametric uncertainty, informing efforts to improve model parameterization via PFT-free and trait-based approaches.


Asunto(s)
Dióxido de Carbono , Ecosistema , Teorema de Bayes , Clima , Ciclo del Carbono
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...