Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 58
Filtrar
1.
Urol Int ; 107(7): 684-692, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37071970

RESUMEN

INTRODUCTION: Diffusion-weighted imaging (DWI) as part of multiparametric magnetic resonance imaging (mpMRI) is an important sequence for the detection of prostate cancer (PCa). The objective of this retrospective analysis was to evaluate changes in apparent diffusion coefficient (ADC) measurements in biopsy-proven PCa undergoing TULSA-PRO (MR-guided transurethral ultrasound ablation of the prostate) at 3.0 T after 1, 3, and 6-12 months posttreatment. METHODS: Nineteen patients underwent follow-up examinations after 1, 3, and 6-12 months including mpMRI at 3.0 T and urological-clinical examinations with quantitative analysis of ADCs. RESULTS: In PCa, a significant increase of ADC values after 6-12 months was measured after TULSA-PRO treatment by 29.1% (pre-TULSA: 0.79 ± 0.16 × 10-3 mm2/s, 6-12 months: 1.02 ± 0.35 × 10-3 mm2/s), while the corresponding value in the reference tissue decreased by 48.5% (pre-TULSA: 1.20 ± 0.15 × 10-3 mm2/s, 6-12 months: 0.91 ± 0.29 × 10-3 mm2/s). The mean ADC values in the early follow-up groups at 1 and 3 months did not change significantly. CONCLUSION: DWI with ADC as part of mpMRI can serve as a biomarker to dynamically monitor the follow-up after TULSA after 6-12 months. For early posttreatment progression, it is not suitable due to too many confounding variables.


Asunto(s)
Neoplasias de la Próstata , Masculino , Humanos , Estudios Retrospectivos , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/cirugía , Imagen de Difusión por Resonancia Magnética/métodos , Próstata/diagnóstico por imagen , Próstata/cirugía , Próstata/patología , Biopsia
2.
Haematologica ; 106(8): 2170-2179, 2021 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-34011137

RESUMEN

The COVID-19 pandemic has resulted in significant morbidity and mortality worldwide. To prevent severe infection, mass COVID-19 vaccination campaigns with several vaccine types are currently underway. We report pathological and immunological findings in 8 patients who developed vaccine-induced immune thrombotic thrombocytopenia (VITT) after administration of SARS-CoV-2 vaccine ChAdOx1 nCoV-19. We analyzed patient material using enzyme immune assays, flow cytometry and heparin-induced platelet aggregation assay and performed autopsies on two fatal cases. Eight patients (5 female, 3 male) with a median age of 41.5 years (range, 24 to 53) were referred to us with suspected thrombotic complications 6 to 20 days after ChAdOx1 nCoV-19 vaccination. All patients had thrombocytopenia at admission. Patients had a median platelet count of 46.5 x109/L (range, 8 to 92). Three had a fatal outcome and 5 were successfully treated. Autopsies showed arterial and venous thromboses in various organs and the occlusion of glomerular capillaries by hyaline thrombi. Sera from VITT patients contain high titer antibodies against platelet factor 4 (PF4) (OD 2.59±0.64). PF4 antibodies in VITT patients induced significant increase in procoagulant markers (P-selectin and phosphatidylserine externalization) compared to healthy volunteers and healthy vaccinated volunteers. The generation of procoagulant platelets was PF4 and heparin dependent. We demonstrate the contribution of antibody-mediated platelet activation in the pathogenesis of VITT.


Asunto(s)
COVID-19 , Trombocitopenia , Adulto , Autoanticuerpos , Plaquetas , Vacunas contra la COVID-19 , ChAdOx1 nCoV-19 , Femenino , Humanos , Masculino , Persona de Mediana Edad , Pandemias , SARS-CoV-2 , Trombocitopenia/inducido químicamente , Vacunación/efectos adversos , Adulto Joven
3.
Onco Targets Ther ; 9: 6425-6433, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27799790

RESUMEN

PURPOSE: The aim of this study was to evaluate an intravoxel incoherent motion (IVIM) model-based analysis of diffusion-weighted imaging (DWI) for assessing the response of hepatocellular carcinoma (HCC) to locoregional therapy. PATIENTS AND METHODS: Respiratory-gated DWI (b=0, 50, and 800 s/mm2) was retrospectively analyzed in 25 patients who underwent magnetic resonance imaging at 1.5 T before and 6 weeks following the first cycle of transarterial chemoembolization therapy, transarterial ethanol-lipiodol embolization therapy, and transarterial radioembolization therapy. In addition to the determination of apparent diffusion coefficient, ADC(0,800), an estimation of the diffusion coefficient, D', and the perfusion fraction, f', was performed by using a simplified IVIM approach. Parameters were analyzed voxel-wise. Tumor response was assessed in a central slice by using a region of interest (ROI) covering the whole tumor. HCCs were categorized into two groups, responders and nonresponders, according to tumor size changes on first and second follow ups (if available) and changes of contrast-enhanced region on the first follow up. RESULTS: In total, 31 HCCs were analyzed: 17 lesions were assigned to responders and 14 were to nonresponders. In responders, ADC(0,800) and D' were increased after therapy by ~30% (P=0.00004) and ~42% (P=0.00001), respectively, whereas f' was decreased by ~37% (P=0.00094). No significant changes were found in nonresponders. Responders and nonresponders were better differentiated by changes in D' than by changes in ADC(0,800) (area under the curve =0.878 vs 0.819 or 0.714, respectively). CONCLUSION: In patients with HCCs undergoing embolization therapy, diffusion changes were better reflected by D' than by conventional ADC(0,800), which is influenced by counteracting perfusion changes as assessed by f'.

4.
Cardiovasc Intervent Radiol ; 39(1): 21-7, 2016 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-26361776

RESUMEN

PURPOSE: To intra-individually compare discomfort levels and patient satisfaction after arterial access closure using the ExoSeal(®) vascular closure device (VCD) and manual compression (MC) in a prospective study design. METHODS: Patients undergoing two planned interventions from 07/2013 to 09/2014 could participate in the study. Access closure was performed with an ExoSeal(®)-VCD in one and MC in the other intervention. Patients were clinically and sonographically examined and were given questionnaires 1 day after intervention [groin- and back-pain during bedrest (100-point visual analog scale; 0: no pain); comfortability of bedrest (10-point Likert scale, 1: comfortable), satisfaction with closure (10-point Likert scale, 1: very satisfied)]. Results were analyzed in a cross-over design. RESULTS: 48 patients (29 male, median age 62.5 (32-88) years) were included. An ExoSeal(®)-VCD was used first in 25 cases. As four of these subsequently refused MC as second intervention, data from 44 patients could be analyzed. All closures were technically successful (successful device deployment) without major complications. Groin- and back-pain after VCD-use/MC was 0 (0-15) vs. 10 (0-80) and 0 (0-75) vs. 25 (0-90), respectively (p < 0.0001). Bedrest after VCD-use was more comfortable than after MC [1 (range 1-7) vs. 6 (2-10); p < 0.0001]. Satisfaction with the closure procedure and with the intervention in general was higher after VCD-use compared to MC [1 (1-3) vs. 5 (2-10) and 1 (1-2) vs. 2 (1-4), respectively; p < 0.0001]. CONCLUSION: Intra-individual comparison showed pain levels and discomfort to be significantly lower after ExoSeal(®) use compared to MC. VCD closure was associated with higher satisfaction both with the closure itself and with the intervention in general.


Asunto(s)
Arteria Femoral , Técnicas Hemostáticas , Satisfacción del Paciente/estadística & datos numéricos , Dispositivos de Cierre Vascular/estadística & datos numéricos , Adulto , Anciano , Anciano de 80 o más Años , Estudios Cruzados , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Encuestas y Cuestionarios , Resultado del Tratamiento
5.
Eur Radiol ; 26(8): 2779-89, 2016 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-26560720

RESUMEN

OBJECTIVES: To retrospectively determine incidence of early arterial blood flow stasis and its influencing factors during resin-based radioembolization (RE) of liver tumours. METHODS: Data of patients undergoing resin-based RE from 06/2006-12/2013 were reviewed. Second RE procedures of the same liver lobe were excluded. 90-yttrium dose was calculated according to the body surface area method. Data were categorized according to RE without full dose application because of early stasis and with full dose application. Clinical/procedural characteristics were recorded. Logistic regression was performed to identify associations between clinical/procedural characteristics and early stasis. RESULTS: 362 patients [220 male; mean age 62 years (range 26-90)] underwent 416 RE sessions with early stasis occurring in 103 REs (24.8 %). Highest incidence and degree of stasis were observed in breast cancer metastases [42.6 % (20/47); 55.8 % of mean intended dose administered]. Independent risk factors were: metastasized breast cancer (odds ratio [OR] 2.18, p = 0.02), liver tumour-burden <25 % and 25-50 % (ORs 5.33, 15.64; p < 0.0001), tumour hypovascularity (OR 2.70, p = 0.04), previous bevacizumab therapy (OR 2.79, p = 0.0009) and concurrent chemotherapy (OR 8.69, p < 0.0001). CONCLUSION: Early stasis was observed in 24.8 % of resin-based REs. In the presence of the identified risk factors, extra care should be taken during microsphere administration. KEY POINTS: • Early arterial blood flow stasis is a known problem of resin-based RE. • The study showed that early stasis occurs in 25 % of REs. • Several clinical and procedural factors are associated with early stasis. • In patients at risk extra care should be taken during RE.


Asunto(s)
Braquiterapia/métodos , Embolia/terapia , Embolización Terapéutica/métodos , Neoplasias Hepáticas/terapia , Microesferas , Radioisótopos de Itrio/uso terapéutico , Adulto , Anciano , Anciano de 80 o más Años , Embolia/etiología , Femenino , Humanos , Incidencia , Neoplasias Hepáticas/complicaciones , Neoplasias Hepáticas/diagnóstico , Masculino , Persona de Mediana Edad , Radiofármacos/uso terapéutico , Estudios Retrospectivos , Factores de Riesgo
6.
Magn Reson Imaging ; 33(10): 1258-1266, 2015 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-26271178

RESUMEN

OBJECTIVES: To intraindividually compare gadoxetate disodium and gadofosveset trisodium regarding vessel contrast, image quality and vessel delineation in dynamic contrast-enhanced liver MRI at 3.0T. METHODS: Twelve patients underwent 3.0T MRI twice (24 examinations) with a single dose of gadoxetate disodium and gadofosveset trisodium, respectively. Signal intensity in abdominal vessels and tissue was determined. Vessel-to-background ratio (VBR) was calculated for each vessel and dynamic phase. All images were evaluated by two radiologists regarding image quality, vessel delineation and anatomic variants or pathologies with digital subtraction angiography as the standard of reference. RESULTS: Gadofosveset trisodium demonstrated a significantly higher VBR compared to gadoxetate disodium (arterial phase: 0.57±0.12 [SD] vs. 0.46±0.19; portal venous phase: 0.51±0.11 vs. 0.37±0.14; equilibrium phase: 0.48±0.10 vs. 0.31±0.13; p≤0.01). Image quality and vessel delineation were rated equal or better for gadofosveset trisodium in all cases. These differences were not significant for most vessel segments. All anatomic variants were correctly identified by both readers for both contrast agents. CONCLUSIONS: Although gadofosveset trisodium provides a significantly higher vessel contrast at 3.0T, gadoxetate disodium is equivalent by qualitative measurements. Thus, gadoxetate-enhanced liver MRI at 3.0T enables reliable assessment of the upper abdominal vasculature with the additional benefit of hepatobiliary imaging.


Asunto(s)
Medios de Contraste , Gadolinio DTPA , Gadolinio , Aumento de la Imagen , Hígado/irrigación sanguínea , Imagen por Resonancia Magnética , Compuestos Organometálicos , Anciano , Angiografía de Substracción Digital , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados
7.
Magn Reson Imaging ; 33(9): 1035-1042, 2015 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-26220860

RESUMEN

INTRODUCTION: Compared to standard arterial-only first-pass MR-angiography (FPMRA), imaging during the equilibrium phase of a blood pool contrast agent (steady state) has been shown to provide higher image quality and better stenosis grading. Homogenous Dixon fat-suppression promises to increase contrast by suppression of fat adjacent to vessels. This study was performed to compare diagnostic image quality and vessel-to-background contrasts in equilibrium phase Dixon-based fat-free MRA (DFSMRA) of run-off vessels to FPMRA imaging and equilibrium phase T1-weighted non-fat-suppressed ultra-high resolution MRA (SSMRA). MATERIAL AND METHODS: In a prospective, intra-individual comparative study, 17 patients with known or suspected peripheral arterial occlusive disease (PAOD; 11 men, mean age 65.6±18.1 [23-89] years) received FPMRA, DFSMRA, and SSMRA at 1.5 Tesla using a clinical whole body MRI scanner. All sequences were performed within the same session applying a single dose of a blood pool contrast agent (gadofosveset trisodium) that was injected during acquisition of FPMRA. The diagnostic image quality of the run-off vessels was evaluated on a 3-point scale. Quantitative analysis consisted of contrast-ratio (CR) measurements of vascular lumen signals compared to signals of adjacent muscle and fat. RESULTS: The average image quality of vessel visualization was rated highest in SSMRA (mean 1.34±0.41), followed by standard FPMRA (mean 1.15±0.33) and DFSMRA (mean 0.99±0.61). Image quality was rated similarly high in the thighs and pelvic region, whereas small vessels in the lower legs and in the feet were best visualized by SSMRA. CR of vascular lumen compared to adjacent fatty tissue was 2.7 times higher in DFSMRA compared to SSMRA, whereas CR of vascular lumen to muscle was 1.3 times higher in SSMRA. CONCLUSION: Vessel to fat contrast is strongly increased in DFSMRA compared to T1-weighted ultra-high resolution non-fat suppressed SSMRA, whereas vessel to muscle contrast is decreased in DFSMRA. Given the current technical limitations of DFSMRA, possible benefits are outweighed by advantages of first-pass imaging regarding arterial selectivity as well as advantages of SSMRA with respect to spatial resolution.


Asunto(s)
Arteriopatías Oclusivas/patología , Medios de Contraste , Aumento de la Imagen , Angiografía por Resonancia Magnética , Enfermedad Arterial Periférica/patología , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Gadolinio , Humanos , Imagenología Tridimensional , Masculino , Persona de Mediana Edad , Compuestos Organometálicos , Pelvis/irrigación sanguínea , Pelvis/patología , Estudios Prospectivos , Sensibilidad y Especificidad , Muslo/irrigación sanguínea , Muslo/patología , Adulto Joven
9.
Eur J Med Res ; 20: 26, 2015 Mar 19.
Artículo en Inglés | MEDLINE | ID: mdl-25889755

RESUMEN

BACKGROUND: Cystic lesions of the pancreas resembling intraductal papillary mucinous neoplasms (IPMN) have been reported to develop in an increased rate following liver transplantation and immunosuppression. The cause for this possible association is thus far elusive. PRESENTATION OF THE CASE: We report on a 60-year-old male patient who developed an extensive multicystic change of the entire pancreas, suspicious for IPMN, under follow-up after liver transplantation for secondary sclerosing cholangitis. A total pancreaduodenectomy with splenectomy was performed. The postoperative histopathological assessment revealed a multifocal branch duct IPMN of the gastric subtype showing low-grade dysplasia. DISCUSSION: In the absence of evidence-based guidelines for the management of suspected IPMNs in liver transplant recipients, each patient's management should be discussed in detail. CONCLUSION: Prospective studies may help to understand the disease and identify risk factors for malignant transformation in IPMNs after liver transplantation for treatment optimization.


Asunto(s)
Trasplante de Hígado , Conductos Pancreáticos/cirugía , Neoplasias Pancreáticas/cirugía , Humanos , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Neoplasias Pancreáticas/diagnóstico
10.
Eur Radiol ; 25(10): 2869-79, 2015 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-25903702

RESUMEN

OBJECTIVES: To compare systematically quantitative MRI, MR spectroscopy (MRS), and different histological methods for liver fat quantification in order to identify possible incongruities. METHODS: Fifty-nine consecutive patients with liver disorders were examined on a 3 T MRI system. Quantitative MRI was performed using a dual- and a six-echo variant of the modified Dixon (mDixon) sequence, calculating proton density fat fraction (PDFF) maps, in addition to single-voxel MRS. Histological fat quantification included estimation of the percentage of hepatocytes containing fat vesicles as well as semi-automatic quantification (qHisto) using tissue quantification software. RESULTS: In 33 of 59 patients, the hepatic fat fraction was >5% as determined by MRS (maximum 45%, mean 17%). Dual-echo mDixon yielded systematically lower PDFF values than six-echo mDixon (mean difference 1.0%; P < 0.001). Six-echo mDixon correlated excellently with MRS, qHisto, and the estimated percentage of hepatocytes containing fat vesicles (R = 0.984, 0.967, 0.941, respectively, all P < 0.001). Mean values obtained by the estimated percentage of hepatocytes containing fat were higher by a factor of 2.5 in comparison to qHisto. Six-echo mDixon and MRS showed the best agreement with values obtained by qHisto. CONCLUSIONS: Six-echo mDixon, MRS, and qHisto provide the most robust and congruent results and are therefore most appropriate for reliable quantification of liver fat. KEY POINTS: • Six-echo mDixon correlates excellently with MRS, qHisto, and the estimated percentage of fat-containing hepatocytes. • Six-echo mDixon, MRS, and qHisto provide the most robust and congruent results. • Dual-echo mDixon yields systematically lower PDFF values than six-echo mDixon. • The percentage of fat-containing hepatocytes is 2.5-fold higher than fat fraction determined by qHisto. • Performance characteristics and systematic differences of the various methods should be considered.


Asunto(s)
Hígado Graso/patología , Adolescente , Adulto , Anciano , Femenino , Hepatocitos/patología , Técnicas Histológicas , Humanos , Imagen por Resonancia Magnética/métodos , Espectroscopía de Resonancia Magnética/métodos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Programas Informáticos , Adulto Joven
11.
Eur Radiol ; 25(11): 3207-13, 2015 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-25903709

RESUMEN

OBJECTIVES: Our aim was to retrospectively evaluate the occurrence of respiratory motion artefacts in patients undergoing dynamic liver magnetic resonance (MR) either with gadoxetate disodium or gadobutrol. METHODS: Two hundred and thirty liver MR studies (115 with gadobutrol, 115 with gadoxetate disodium) were analysed. Respiratory motion artefacts on dynamic 3D T1-weighted MR images (pre-contrast, arterial, venous, and late-dynamic phase) were assessed using a five-point rating scale. Severe motion was defined as a score ≥ 4. Mean motion scores were compared with the Mann-Whitney-U-test. The chi-squared-test was used for dichotomous comparisons. RESULTS: Mean motion scores for gadoxetate disodium and gadobutrol showed no relevant differences for each phase of the dynamic contrast series (pre-contrast: 1.85 ± 0.70 vs. 1.88 ± 0.57, arterial: 1.85 ± 0.81 vs. 1.87 ± 0.74, venous: 1.82 ± 0.67 vs. 1.74 ± 0.64, late-dynamic: 1.75 ± 0.62 vs. 1.79 ± 0.63; p = 0.469, 0.557, 0.382 and 0.843, respectively). Severe motion artefacts had a similar incidence using gadoxetate disodium and gadobutrol (11/460 [2.4%] vs. 7/460 [1.5%]; p = 0.341). CONCLUSIONS: Gadoxetate disodium is associated with equivalent motion scores compared to gadobutrol in dynamic liver MRI. In addition, both contrast agents demonstrated a comparable and acceptable rate of severe respiratory motion artefacts. KEY POINTS: • Gadobutrol and gadoxetate disodium showed comparable motion scores in dynamic phase imaging. • The incidence of severe motion artefacts was pronounced in arterial phase imaging. • Adverse respiratory side effects were not recorded in 115 examinations with gadoxetate disodium.


Asunto(s)
Artefactos , Medios de Contraste , Gadolinio DTPA , Cirrosis Hepática/patología , Hepatopatías/patología , Compuestos Organometálicos , Adulto , Anciano , Anciano de 80 o más Años , Arterias , Femenino , Humanos , Imagenología Tridimensional , Imagen por Resonancia Magnética/métodos , Masculino , Persona de Mediana Edad , Movimiento (Física) , Respiración , Estudios Retrospectivos
12.
Radiother Oncol ; 113(1): 115-20, 2014 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-25304719

RESUMEN

BACKGROUND AND PURPOSE: Diffusion weighted imaging (DWI) as a functional MR technique allows for both qualitative and quantitative assessment of tumour cellularity and changes during therapy. The objective of this study was to evaluate changes of apparent diffusion coefficient (ADC) in biopsy proven prostate cancer (PCa) under intensity modulated radiotherapy (IMRT) at 3T. MATERIAL & METHODS: Thirteen patients with biopsy proven PCa treated with intensity modulated external beam radiotherapy (IMRT) underwent four standardized MR examinations after approval of the local institutional review board. These included DWI at 3T on a strict time table: before, in between, directly after (between 1 and 4 days after the last radiation), as well as 3 months after IMRT. Quantitative analysis of two different ADCs, - the ADC(0,800) and the ADC(50,800), was performed dynamically over 4 time points in PCa, gluteal muscle and healthy prostate tissue. RESULTS: In PCa, a significant increase of ADC(0,800)/ADC(50,800) values was measured under IMRT by about 16%/15% (P=0.00008/0.00017), 21%/21% (P=0.00006/0.00030), and 33%/34% (P=0.00004/0.00002) at the three time points compared to initial value. Healthy prostate tissue did not show any significant increase. CONCLUSION: DWI is suitable as a biomarker for radiation therapy response of PCa by allowing the dynamic monitoring of treatment effectiveness.


Asunto(s)
Neoplasias de la Próstata/radioterapia , Radioterapia de Intensidad Modulada , Anciano , Anciano de 80 o más Años , Biopsia , Imagen de Difusión por Resonancia Magnética/métodos , Humanos , Masculino , Persona de Mediana Edad , Clasificación del Tumor , Estudios Prospectivos , Prostatectomía , Neoplasias de la Próstata/patología , Neoplasias de la Próstata/cirugía , Resultado del Tratamiento
13.
Eur Radiol ; 24(10): 2482-90, 2014 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-25030459

RESUMEN

OBJECTIVES: To evaluate hepatobiliary magnetic resonance imaging (MRI) using Gd-EOB-DTPA in relation to various liver function tests in patients with liver disorders. METHODS: Fifty-one patients with liver disease underwent Gd-EOB-DTPA-enhanced liver MRI. Based on region-of-interest (ROI) analysis, liver signal intensity was calculated using the spleen as reference tissue. Liver-spleen contrast ratio (LSCR) and relative liver enhancement (RLE) were calculated. Serum levels of total bilirubin, gamma glutamyl transpeptidase (GGT), aspartate aminotransferase (AST), alanine aminotransferase (ALT), glutamate dehydrogenase (GLDH), lactate dehydrogenase (LDH), serum albumin level (AL), prothrombin time (PT), creatinine (CR) as well as international normalised ratio (INR) and model for end-stage liver disease (MELD) score were tested for correlation with LSCR and RLE. RESULTS: Pre-contrast LSCR values correlated with total bilirubin (r = -0.39; p = 0.005), GGT (r = -0.37; p = 0.009), AST (r = -0.38; p = 0.013), ALT (r = -0.29; p = 0.046), PT (r = 0.52; p < 0.001), GLDH (r = -0.55; p = 0.044), INR (r = -0.42; p = 0.003), and MELD Score (r = -0.53; p < 0.001). After administration of Gd-EOB-DTPA bilirubin (r = -0.45; p = 0.001), GGT (r = -0.40; p = 0.004), PT (r = 0.54; p < 0.001), AST (r = -0.46; p = 0.002), ALT (r = -0.31; p = 0.030), INR (r = -0.45; p = 0.001) and MELD Score (r = -0.56; p < 0.001) significantly correlated with LSCR. RLE correlated with bilirubin (r = -0.40; p = 0.004), AST (r = -0.38; p = 0.013), PT (r = 0.42; p = 0.003), GGT (r = -0.33; p = 0.020), INR (r = -0.36; p = 0.011) and MELD Score (r = -0.43; p = 0.003). CONCLUSIONS: Liver-spleen contrast ratio and relative liver enhancement using Gd-EOB-DTPA correlate with a number of routinely used biochemical liver function tests, suggesting that hepatobiliary MRI may serve as a valuable biomarker for liver function. The strongest correlation with liver enhancement was found for the MELD Score. KEY POINTS: • Relative enhancement (RLE) of Gd-EOB-DTPA is related to biochemical liver function tests. • Correlation of RLE with bilirubin, ALT, AST, GGT, INR and MELD Score is reverse. • The correlation of relative liver enhancement with prothrombin time is positive. • AST, ALT, GLDH, prothrombin time, INR and MELD Score correlate with pre-contrast liver-spleen contrast ratio. • Such biomarkers may help to evaluate liver function.


Asunto(s)
Biomarcadores/sangre , Gadolinio DTPA , Hepatopatías/patología , Pruebas de Función Hepática/métodos , Imagen por Resonancia Magnética/métodos , Adulto , Anciano , Anciano de 80 o más Años , Alanina Transaminasa/sangre , Bilirrubina/sangre , Medios de Contraste , Femenino , Glutamato Deshidrogenasa/sangre , Humanos , L-Lactato Deshidrogenasa/sangre , Hepatopatías/sangre , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Estudios Retrospectivos , Albúmina Sérica/metabolismo , gamma-Glutamiltransferasa/sangre
14.
J Magn Reson Imaging ; 40(4): 857-63, 2014 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-24924914

RESUMEN

PURPOSE: To evaluate the use of the recently proposed ultrafast B1 (+) mapping approach DREAM (Dual Refocusing Echo Acquisition Mode) for a refinement of patient adaptive radiofrequency (RF) shimming. MATERIALS AND METHODS: Volumetric DREAM B1 (+) calibration scans centered in the upper abdomen were acquired in 20 patients and three volunteers with written informed consent at a clinical dual source 3 Tesla (T) MR system. Based on these data, RF transmit settings were optimized by central-slice based RF-shimming (CS-RF shim) and by a refined, multi-slice adaptive approach (MS-RF shim). Simulations were performed to compare flip angle accuracy and B1 (+) homogeneity (cv = stddev/mean) achieved by CS-RF shim versus MS-RF shim for transversal and coronal slices, and for volume shimming on the spine. RESULTS: By MS-RF shim, mean deviation from nominal flip angle was reduced to less than 11% in all slices, all targets, and all subjects. Relative improvements in B1 (+) cv (MS-RF shim versus CS-RF) were up to 14%/39%/47% in transversal slices/coronal slices/ spine area. CONCLUSION: Volumetric information about B1 (+) can be used to further improve the accuracy and homogeneity of the B1 (+) field yielding higher diagnostic confidence, and will also be of value for various quantitative methods which are sensitive to flip angle imperfections.


Asunto(s)
Algoritmos , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Imagenología Tridimensional/métodos , Imagen por Resonancia Magnética/métodos , Imagen de Cuerpo Entero/métodos , Adulto , Anciano , Humanos , Persona de Mediana Edad , Ondas de Radio , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Adulto Joven
15.
J Magn Reson Imaging ; 40(4): 996-1001, 2014 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-24845363

RESUMEN

PURPOSE: To implement and evaluate high spatial resolution three-dimensional MR contrast-enhanced angiography (3D-CEMRA) of the thighs using a blood pool contrast agent (BPCA) using the quadrature body coil only in patients with peripheral arterial occlusive disease (PAOD) in cases receiver coils cannot be used at 1.5 Tesla (T). MATERIALS AND METHODS: Nineteen patients (mean age: 68.7 ± 11.2 years; range, 38-83 years) with known PAOD (Fontaine stages; III: 16, IV: 3) prospectively underwent 3D-CEMRA at 1.5T with a noninterpolated voxel size of 0.49 × 0.49 × 0.48 mm(3) . Digital subtraction angiography (DSA) was available for comparison in all patients. Two readers independently evaluated movement artifacts, overall image quality of 3D-CEMRA, and grade of stenosis as compared to DSA. SNR and CNR levels were quantified. RESULTS: The 3D-CEMRA was successfully completed in all patients. Patient movement artifacts that affected stenosis grading occurred in 3/38 thighs. Overall image quality was rated excellent in 15/38, good in 12/38, and diagnostic in 8/38 thighs. Stenosis grading matched with that in DSA in 35/38 thighs. High SNR and CNR were measured in all vessels. CONCLUSION: The 0.125 mm(3) spatial resolution 3D-CEMRA of the thighs with a BPCA is feasible using a quadrature body coil exclusively with excellent image quality despite long acquisition times. J. Magn. Reson. Imaging 2014;40:996-1001. © 2014 Wiley Periodicals, Inc.


Asunto(s)
Arteriopatías Oclusivas/fisiopatología , Gadolinio , Aumento de la Imagen/instrumentación , Angiografía por Resonancia Magnética/instrumentación , Compuestos Organometálicos , Enfermedad Arterial Periférica/fisiopatología , Muslo/fisiopatología , Adulto , Anciano , Anciano de 80 o más Años , Arteriopatías Oclusivas/patología , Velocidad del Flujo Sanguíneo/fisiología , Medios de Contraste , Diseño de Equipo , Análisis de Falla de Equipo , Estudios de Factibilidad , Femenino , Humanos , Aumento de la Imagen/métodos , Imagenología Tridimensional/instrumentación , Imagenología Tridimensional/métodos , Angiografía por Resonancia Magnética/métodos , Masculino , Persona de Mediana Edad , Enfermedad Arterial Periférica/patología , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Muslo/irrigación sanguínea , Muslo/patología
16.
Eur Radiol ; 24(2): 267-76, 2014 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-24081644

RESUMEN

OBJECTIVES: To evaluate diffusion-weighted MRI with acquisition of three b-values and calculation of fractioned ADCs for response evaluation of neuroendocrine liver metastases undergoing selective internal radiotherapy (SIRT). METHODS: Ten consecutive patients with neuroendocrine liver metastases underwent MRI before and following SIRT. Diffusion-weighted imaging included acquisition of the b-values 0, 50 and 800 s/mm(2) and calculation of ADC(50,800), ADC(0,50) and ADC(0,800) maps. According to therapy response, lesions were categorised into group A [≥20% reduction of the longest diameter (LD) in comparison to baseline MRI] and group B (<20% reduction of the LD). RESULTS: Twelve out of 31 metastases were categorised as group A and 19 out of 31 metastases were categorised as group B. Pretherapeutic values of ADC(0,800) and ADC(50,800) did not differ significantly between the two groups; however, ADC(0,50) was 32% lower in group A (P = 0.049). ADC(0,800) and ADC(50,800) increased significantly after therapy in both groups, however, group differences were not statistically significant. Conversely, the increase in ADC(0,50) was about a factor of 7 larger in group A than in group B (P = 0.023). CONCLUSIONS: Our study showed that the ADC(0,50) is a promising biomarker for response assessment of neuroendocrine liver metastases following SIRT. KEY POINTS: • Diffusion-weighted MRI offers new information about neuroendocrine hepatic metastases. • Evaluation of perfusion and diffusion components requires fractioned apparent diffusion coefficients (ADCs). • Perfusion effects represented by ADC (0.50) can be observed in neuroendocrine metastases. • Pretherapeutic ADC (0.50) was significantly lower in metastases with a response ≥20%. • Such biomarkers may help evaluate liver metastases in patients undergoing therapy.


Asunto(s)
Braquiterapia/métodos , Imagen de Difusión por Resonancia Magnética/métodos , Neoplasias Gastrointestinales/patología , Neoplasias Gastrointestinales/radioterapia , Neoplasias Hepáticas/diagnóstico , Neoplasias Hepáticas/radioterapia , Tumores Neuroendocrinos/diagnóstico , Tumores Neuroendocrinos/radioterapia , Anciano , Diagnóstico Diferencial , Femenino , Estudios de Seguimiento , Humanos , Neoplasias Hepáticas/secundario , Masculino , Microesferas , Persona de Mediana Edad , Tumores Neuroendocrinos/secundario , Estudios Retrospectivos
17.
Invest Radiol ; 49(2): 93-100, 2014 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-24089021

RESUMEN

OBJECTIVES: The objective of this study was to evaluate the diagnostic benefit of an intravoxel incoherent motion (IVIM) model-based characterization of pancreatic masses from diffusion-weighted imaging (DWI) with 3 b values. MATERIALS AND METHODS: This retrospective study had an approval from the institutional review board, and informed patient consent was waived. The 1.5-T DWI data of 42 patients with or without pancreatic disease, acquired by a respiratory-gated spin-echo echo-planar imaging sequence with 3 b values (0, 50, 800 s/mm²), were retrospectively analyzed. The IVIM-related parameters D', which is the apparent diffusion coefficient [ADC(50,800)], and f', as well as ADC(0,50), and conventional ADC(0,800) were calculated voxelwise. Regions of interest were analyzed in pancreatic adenocarcinomas (CAs, n = 12), neuroendocrine pancreatic tumors (NETs, n = 9), and chronic pancreatitis (CPs, n = 11), not affected tissue of each pathologic group, and in the head, body, and tail of the healthy pancreas (n = 10). RESULTS: By ADC(0,800) and D', CAs could hardly be distinguished from neuroendocrine pancreatic tumors and chronic pancreatitis. However, CAs revealed very low ADC(0,50) and f' values, which differed significantly from all other groups. In the healthy pancreas, ADC(0,800) and D' values were significantly higher for the head than for the body and tail, but no significant differences were found for ADC(0,50) and f'. CONCLUSIONS: The determination of IVIM-based microcirculation-sensitive parameter maps from DWI with 3 b values significantly improved the discrimination of CAs from NETs, CPs, and the healthy tissue.


Asunto(s)
Adenocarcinoma/patología , Artefactos , Imagen por Resonancia Magnética/métodos , Tumores Neuroendocrinos/patología , Neoplasias Pancreáticas/patología , Pancreatitis/patología , Técnicas de Imagen Sincronizada Respiratorias/métodos , Adulto , Anciano , Anciano de 80 o más Años , Enfermedad Crónica , Diagnóstico Diferencial , Femenino , Humanos , Aumento de la Imagen/métodos , Imagenología Tridimensional/métodos , Masculino , Persona de Mediana Edad , Movimiento (Física) , Movimiento , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
18.
Magn Reson Med ; 70(1): 136-46, 2013 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-22926895

RESUMEN

This work presents a novel method for the rapid and simultaneous measurement of R1 and R2* relaxation rates. It is based on a dynamic short repetition time steady-state spoiled multigradient-echo sequence and baseline R1 and B1 measurements. The accuracy of the approach was evaluated in simulations and a phantom experiment. The sensitivity and specificity of the method were demonstrated in one volunteer and in four patients with intracranial tumors during carbogen inhalation. We utilized (ΔR2*, ΔR1) scatter plots to analyze the multiparametric response amplitude of each voxel within an area of interest. In normal tissue R2* decreased and R1 increased moderately in response to the elevated blood and tissue oxygenation. A strong negative ΔR2* and ΔR1 response was observed in veins and some tumor areas. Moderate positive ΔR2* and ΔR1 response amplitudes were found in fluid-rich tissue as in cerebrospinal fluid, peritumoral edema, and necrotic areas. The multiparametric approach was shown to increase the specificity and sensitivity of oxygen-enhanced MRI compared to measuring ΔR2* or ΔR1 alone. It is thus expected to provide an optimal tool for the identification of tissue areas with low oxygenation, e.g., in tumors with compromised oxygen supply.


Asunto(s)
Imagen por Resonancia Magnética/métodos , Imagen Molecular/métodos , Neoplasias/diagnóstico , Neoplasias/metabolismo , Oximetría/métodos , Oxígeno/sangre , Administración por Inhalación , Anciano , Femenino , Humanos , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Masculino , Persona de Mediana Edad , Oxígeno/administración & dosificación , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
19.
Neuroimaging Clin N Am ; 22(2): 235-57, x, 2012 May.
Artículo en Inglés | MEDLINE | ID: mdl-22548930

RESUMEN

Recent advances in magnetic resonance (MR) hardware and software have improved the resolution and spatial coverage of head and neck first-pass contrast-enhanced (CE) MR angiography. Despite these improvements, high-quality submillimeter-resolution 1.5 T and 3 T carotid CE MR angiography is not consistently available in the general radiology practice. This article reviews the important imaging parameters and potential pitfalls that affect carotid CE MR angiography image quality, and the dose and timing of the gadolinium-based contrast agent, and summarizes vendor-specific protocols for high-quality submillimeter-resolution carotid CE MR angiography at 1.5 and 3 T.


Asunto(s)
Arterias Carótidas/patología , Enfermedades de las Arterias Carótidas/patología , Medios de Contraste , Aumento de la Imagen/métodos , Angiografía por Resonancia Magnética/métodos , Humanos
20.
AJR Am J Roentgenol ; 198(5): 1188-95, 2012 May.
Artículo en Inglés | MEDLINE | ID: mdl-22528912

RESUMEN

OBJECTIVE: The purpose of this study was to investigate the prevalence of incidental deep venous thrombosis (DVT) in patients with clinically suspected peripheral arterial occlusive disease (PAOD) using contrast-enhanced MR angiography (MRA) with a blood pool contrast agent. SUBJECTS AND METHODS: Two hundred fifty-nine MRA examinations with blood pool contrast agent in 245 consecutive patients (161 men; age range, 36-92 years), yielding a total of 4102 assessable arterial and venous vessel segments, were assessed with regard to the rate of incidentally observed acute and organized DVT and arterial stenosis grades. Incidental DVT was confirmed using duplex ultrasound. Contralateral nondiseased veins served as internal controls. The relationship between PAOD stages and acute and organized DVT was investigated using chi-square tests and a Mann-Whitney U test. RESULTS: Arterial stenosis grading using MRA with blood pool contrast agent revealed less than 50% luminal stenosis in 78% of segments (3199/4102), 50% or greater stenosis in 8% of segments (317/4102), and occlusion in 14% of segments (586/4102). Incidental DVT was observed in 26 of 245 patients (11%) (acute DVT was seen in 10 patients and 26 segments; organized DVT was seen in 17 patients and 35 segments; and one patient had both acute and organized DVT). All incidentally diagnosed cases of DVT were confirmed by duplex ultrasound. Internal controls revealed no false-positive or -negative findings (26 patients and 172 segments). Incidental acute DVT was significantly more common among patients without arterial stenosis greater than 50% (p < 0.05). Otherwise, there was no significant relationship between Fontaine PAOD stages and the occurrence of acute (p = 0.688) or organized (p = 0.995) DVT. CONCLUSION: Incidental DVT was prevalent in 11% of patients with clinically suspected PAOD. MRA with blood pool contrast agent has a potential role in the simultaneous assessment of arteries and veins and can detect concomitant venous disease affecting therapeutic management.


Asunto(s)
Arteriopatías Oclusivas/diagnóstico , Medios de Contraste , Gadolinio , Angiografía por Resonancia Magnética/métodos , Compuestos Organometálicos , Enfermedades Vasculares Periféricas/diagnóstico , Trombosis de la Vena/diagnóstico , Adulto , Anciano , Anciano de 80 o más Años , Arteriopatías Oclusivas/diagnóstico por imagen , Arteriopatías Oclusivas/epidemiología , Distribución de Chi-Cuadrado , Femenino , Humanos , Interpretación de Imagen Asistida por Computador , Hallazgos Incidentales , Masculino , Persona de Mediana Edad , Enfermedades Vasculares Periféricas/diagnóstico por imagen , Enfermedades Vasculares Periféricas/epidemiología , Prevalencia , Estadísticas no Paramétricas , Ultrasonografía Doppler Dúplex , Trombosis de la Vena/diagnóstico por imagen , Trombosis de la Vena/epidemiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...