Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 22
Filtrar
1.
Scand J Immunol ; 69(1): 36-42, 2009 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-19140875

RESUMEN

Inflammation plays a key role in the development of atherosclerosis. Genetic differences in molecules related to inflammation have therefore been linked to the susceptibility for and severity of atherosclerosis. We hypothesized that the additive contribution from different genes of importance for inflammation would enhance the severity of cardiovascular disease. Blood samples were collected from 230 adults admitted for elective coronary angiography. A total of 130 patients had significant (>50%) stenosis in at least one main coronary artery branch and 100 had not. Six polymorphisms in five different genes were analysed: myeloperoxidase (MPO) -129G/A and -463G/A, toll-like receptor 4 (TLR4) Asp299Gly, interleukin-6 (IL6) -174G/C, surfactant protein D (SFTPD) Met11Thr and regulated upon normal T-cell expressed and secreted (CCL5) -403G/A. The IL6 polymorphism was significantly associated (P = 0.017) to angiographic significant coronary artery disease, and this relation remained after adjustment for age, gender, smoking and hypercholesterolaemia (P = 0.007). The TLR4 (P = 0.050) and SFTPD (P = 0.058) polymorphisms were also associated with the presence of coronary stenosis in univariate but not in multivariate analyses. For MPO and CCL5 no associations were found. There was a significant linear association between the number of high-risk gene variants (IL6-174CC, SFTPD 11CC and TLR4 299AA) and the proportion of patients with coronary artery disease (P < 0.0005). Inherited factors related to inflammation may increase susceptibility for severe coronary artery disease. Furthermore, the additive contribution from different inflammatory genetic markers strongly enhances the individual severity of cardiovascular disease.


Asunto(s)
Enfermedad Coronaria/genética , Predisposición Genética a la Enfermedad , Interleucina-6/genética , Proteína D Asociada a Surfactante Pulmonar/genética , Receptor Toll-Like 4/genética , Enfermedad Coronaria/patología , Femenino , Ligamiento Genético , Marcadores Genéticos , Humanos , Inflamación/genética , Inflamación/patología , Masculino , Persona de Mediana Edad , Polimorfismo Genético
2.
Acta Radiol ; 47(7): 680-6, 2006 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-16950705

RESUMEN

PURPOSE: To evaluate whether the favorable results achieved with multislice computed tomography (MSCT) of coronary arteries at larger centers could be paralleled at a local hospital. MATERIAL AND METHODS: Fifty consecutive patients with suspected coronary artery disease scheduled for invasive investigation with quantitative coronary angiography (QCA) at a university hospital underwent MSCT with a 16-slice scanner at a local hospital. Diagnostic accuracy of MSCT for coronary artery disease was assessed using a 16-segment coronary artery model with QCA as the gold standard. RESULTS: Segments with diameter <2 mm, as defined by QCA, segments distal to occlusions, and stented segments were excluded. Of the remaining 489 segments, 73 (15%) were not assessable with MSCT. Sensitivity, specificity, and positive and negative predictive values for significant (>50%) stenosis for the 416 assessable segments were 92%, 82%, 53%, and 98%, respectively. CONCLUSION: Our beginners' experience demonstrated favorable results regarding sensitivity and negative predictive value. The positive predictive value, however, was unsatisfactory. Calcifications were identified as the most important factor for false-positive results with MSCT. With widespread use of MSCT coronary angiography, there is a risk of recruiting patients without significant coronary artery disease to unnecessary and potentially harmful invasive procedures.


Asunto(s)
Angiografía Coronaria/métodos , Estenosis Coronaria/diagnóstico por imagen , Hospitales Comunitarios , Tomografía Computarizada por Rayos X , Adulto , Anciano , Anciano de 80 o más Años , Medios de Contraste , Femenino , Humanos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Valor Predictivo de las Pruebas , Sensibilidad y Especificidad , Ácidos Triyodobenzoicos
3.
Acta Anaesthesiol Scand ; 48(9): 1155-62, 2004 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-15352962

RESUMEN

BACKGROUND: The pharmacokinetic properties of the short-acting micro opioid receptor-agonist remifentanil makes it possible to give cardiac surgical patients a deep intraoperative anesthesia without experiencing postoperative respiratory depression and a prolonged stay in the intensive care unit (ICU). However, previous investigations have shown that patients who received remifentanil required additional analgesia during the early postoperative period as compared to patients who received fentanyl. The aim of the present study therefore was to investigate the effects of supplementing remifentanil to a standard fentanyl-based anesthesia in coronary artery bypass grafting (CABG). METHODS: The study was prospective, randomized, double-blind, and placebo-controlled. Twenty male patients aged 55-70 years were included. All patients received a standard fentanyl and isoflurane-based anesthesia. In addition, the patients were randomized to receive either remifentanil 0.5 micro g kg(-1) min(-1) or placebo during surgery. Hemodynamic recordings and measurements of blood glucose and plasma adrenaline and noradrenaline were performed intra- and postoperatively. RESULTS: Remifentanil reduced the hemodynamic and metabolic response to surgical stress compared to the standard fentanyl-based anesthetic regimen. However, the patients in the remifentanil group had a lower cardiac output (CO), left ventricular stroke work index (LVSWI), and mixed venous oxygen saturation (SvO(2)), and a higher central venous pressure (CVP) than the patients in the placebo group during the early postoperative phase, indicating a postoperative cardiac depression in the remifentanil group. CONCLUSION: In CABG, remifentanil reduces the hemodynamic and metabolic responses during surgery but seems to give a cardiac depression in the early postoperative phase.


Asunto(s)
Anestesia General , Anestésicos Intravenosos/efectos adversos , Puente de Arteria Coronaria , Piperidinas/efectos adversos , Complicaciones Posoperatorias/inducido químicamente , Complicaciones Posoperatorias/fisiopatología , Anciano , Anestesia Intravenosa , Arritmias Cardíacas/inducido químicamente , Arritmias Cardíacas/epidemiología , Biomarcadores , Análisis de los Gases de la Sangre , Creatina Quinasa/sangre , Depresión Química , Método Doble Ciego , Electrocardiografía Ambulatoria , Hemodinámica/efectos de los fármacos , Humanos , Isoenzimas/sangre , Masculino , Persona de Mediana Edad , Monitoreo Intraoperatorio , Propofol , Estudios Prospectivos , Remifentanilo , Troponina I/sangre
4.
J Am Coll Cardiol ; 38(6): 1598-603, 2001 Nov 15.
Artículo en Inglés | MEDLINE | ID: mdl-11704369

RESUMEN

OBJECTIVES: The purpose of this study was to assess the clinical and angiographic benefits of elective stenting in coronary arteries with a reference diameter of 2.1 to 3.0 mm, as compared with traditional percutaneous transluminal coronary angioplasty (PTCA). BACKGROUND: The problems related to small-vessel stenting might be overcome using modern stents designed for small vessels, combined with effective antiplatelet therapy. METHODS: In five centers, 145 patients with stable or unstable angina were randomly assigned to elective stenting treatment with the heparin (Hepamed)-coated beStent or PTCA. Control angiography was performed after six months. The primary end point was the minimal lumen diameter (MLD) at follow-up. Secondary end points were the restenosis rate, event-free survival and angina status. RESULTS: At follow-up, there was a trend toward a larger MLD in the stent group (1.69 +/- 0.52 mm vs. 1.57 +/- 0.44 mm, p = 0.096). Event-free survival at follow-up was significantly higher in the stent group: 90.5% vs. 76.1% (p = 0.016). The restenosis rate was low in both groups (9.7% and 18.8% in the stent and PTCA groups, respectively; p = 0.15). Analyzed as treated, both the MLD and restenosis rate were significantly improved in patients who had stents as compared with PTCA. CONCLUSIONS: In small coronary arteries, both PTCA and elective stenting are associated with good clinical and angiographic outcomes after six months. Compared with PTCA, elective treatment with the heparin-coated beStent improves the clinical outcome; however, there was only a nonsignificant trend toward angiographic improvement.


Asunto(s)
Angioplastia Coronaria con Balón , Enfermedad Coronaria/terapia , Stents , Distribución de Chi-Cuadrado , Materiales Biocompatibles Revestidos , Angiografía Coronaria , Enfermedad Coronaria/diagnóstico por imagen , Reestenosis Coronaria/epidemiología , Reestenosis Coronaria/prevención & control , Vasos Coronarios/patología , Diseño de Equipo , Heparina/uso terapéutico , Humanos , Inhibidores de Agregación Plaquetaria/uso terapéutico , Estadísticas no Paramétricas , Análisis de Supervivencia , Resultado del Tratamiento
6.
Scand Cardiovasc J ; 35(1): 14-8, 2001 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-11354565

RESUMEN

OBJECTIVE: In Norway "Transmyocardial laser revascularization" as a routine method was prohibited by the Ministry of Health in 1995 due to lacking evidence of treatment effect and concerns about procedural morbidity and mortality. In 1999 Norwegian health authorities asked for a re-evaluation of the method based on a systematic review of literature. METHODS: Medline and Embase were searched and a total of 267 articles were identified. Publications were classified by an expert panel according to type of study and importance for the project. RESULTS: Based on the literature review the panel concluded that heart laser treatment does not have a life-saving effect, nor does it improve myocardial function. However, the method has a considerable short-term symptomatic effect, the mechanism of which is not understood. Neoangiogenesis, denervation and placebo may play a role. Based on the report the Norwegian health authorities recommended use of this method be restricted to scientific trials only. CONCLUSIONS: Based on a systematic literature review it was concluded that the only documented effect of heart laser treatment is symptom relief, the mechanism for which is unclear. It could partly or totally be a placebo effect. A conflict of interest may arise when new technologies are to be implemented in health care. The communication between professionals evaluating scientific results and decision makers is challenging. Quality assurance of this process may be obtained by use of expert panels working under the auspices of an official institution.


Asunto(s)
Cardiopatías/mortalidad , Cardiopatías/cirugía , Terapia por Láser/mortalidad , Terapia por Láser/tendencias , Revascularización Miocárdica/mortalidad , Revascularización Miocárdica/tendencias , Humanos , Terapia por Láser/efectos adversos , Revascularización Miocárdica/efectos adversos , Noruega , Tasa de Supervivencia
7.
J Am Soc Echocardiogr ; 13(12): 1053-64, 2000 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-11119272

RESUMEN

Regional strain rate in the left ventricle can be assessed in real time and color mapped. The method is termed strain rate imaging (SRI), and findings correspond well with 2-dimensional echocardiography. This study addresses SRI as a method for localizing coronary lesions, compared with standard echocardiography. Twenty patients with acute myocardial infarction who underwent coronary angiography for clinical reasons were examined with SRI and standard echocardiography. Wall motion was graded by SRI color and separately by wall thickening. Strain rate imaging and 2-dimensional echocardiography results agreed well. An infarct-related artery was identified from angiograms combined with electrocardiograms. Both methods identified an infarct-related artery in 19 possible cases and had equal sensitivity and specificity for wall segments affected by lesion. Combining the information from both methods did not change accuracy. The study validates SRI as a method for assessing regional wall function in coronary artery disease. The advantages of SRI are discussed and measurements of strain rates are given.


Asunto(s)
Ecocardiografía/métodos , Infarto del Miocardio/diagnóstico por imagen , Infarto del Miocardio/fisiopatología , Adulto , Anciano , Análisis de Varianza , Angiografía Coronaria , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Sensibilidad y Especificidad , Estadísticas no Paramétricas , Disfunción Ventricular Izquierda/diagnóstico por imagen , Disfunción Ventricular Izquierda/fisiopatología
8.
J Intern Med ; 248(6): 492-500, 2000 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-11155142

RESUMEN

OBJECTIVE: To study cardiovascular status and risk factors in persons with newly diagnosed type 2 diabetes and controls in a large population. DESIGN: Case-control study. SETTING: Population screening. SUBJECTS: The screening of 74 499 individuals (88.1%), aged 20 years and older, in Nord-Trøndelag County, Norway, during 1984-86 detected 428 persons with undiagnosed diabetes according to the 1980 WHO criteria, of whom 205 attended a clinical follow-up examination assessing cardiovascular status and risk factors. METHODS: For each of 205 cases, one control person matched by age and sex underwent the same clinical examination. Lipids, body mass index, waist/hip ratio, blood pressure, pulse rate, blood pressure medication, kidney function, cardiovascular disease, family history and lifestyle were recorded. RESULTS: At the screening prior to the diagnosis of diabetes, those with diabetes reported poorer general health, less physical activity, more siblings with diabetes and more frequent use of antihypertensive medication. They had higher body mass index, systolic and diastolic blood pressure and pulse rate compared with controls. At the clinical evaluation, diabetics had higher urine albumin levels, increased waist/hip ratio, and higher total cholesterol/HDL cholesterol ratios than the controls. They also reported a greater incidence of angina pectoris and had more ECG changes. CONCLUSIONS: Diabetics presented with more cardiovascular risk factors, angina pectoris and ECG changes than the controls, and they had an established metabolic syndrome more often than controls. These results suggest that prevention of cardiovascular disease in diabetics requires earlier diagnosis of the diabetes.


Asunto(s)
Enfermedades Cardiovasculares/epidemiología , Diabetes Mellitus Tipo 2/epidemiología , Tamizaje Masivo , Adulto , Anciano , Anciano de 80 o más Años , Glucemia/análisis , Enfermedades Cardiovasculares/sangre , Enfermedades Cardiovasculares/diagnóstico , Distribución de Chi-Cuadrado , Diabetes Mellitus Tipo 2/sangre , Diabetes Mellitus Tipo 2/diagnóstico , Ayuno/sangre , Femenino , Humanos , Masculino , Tamizaje Masivo/métodos , Tamizaje Masivo/estadística & datos numéricos , Persona de Mediana Edad , Noruega/epidemiología , Distribución Aleatoria , Factores de Riesgo , Encuestas y Cuestionarios
9.
Am J Hypertens ; 9(11): 1090-8, 1996 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-8931834

RESUMEN

Hemodynamic alterations associated with the blood pressure response in subjects with white coat hypertension may provide insight into the pathophysiologic mechanisms of this condition. Systemic arterial hemodynamics were investigated with a recently validated method based on noninvasive estimates of aortic root pressure and flow in 28 subjects with white coat hypertension (diastolic pressure > or = 90 mm Hg measured by the general practitioner [GP arterial pressure] and ambulatory daytime pressures < 140/90 mm Hg), in 23 subjects with previously untreated, ambulatory hypertension (GP diastolic pressure > or = 90 and < 115 mm Hg and ambulatory daytime diastolic pressure > or = 90 mm Hg), and in 32 normotensive subjects. The groups did not differ significantly concerning age, gender, body surface area, heart rate, stroke index and cardiac index, but total peripheral resistance index was increased and total arterial compliance reduced in the white coat group and the hypertensive group compared to the normotensive group. The subjects in the white coat group with a systolic arterial pressure during echocardiography that was > 5 mm Hg higher than the ambulatory daytime systolic pressure (n = 19) had increased cardiac index, increased total peripheral resistance, and decreased total arterial compliance compared to the normotensive group. The subjects in this group with a hemodynamic pattern characterized by a high ratio of cardiac index/peripheral vascular resistance were significantly younger than the subjects with the opposite pattern. Thus, the blood pressure increase in subjects with white coat hypertension is associated with increased cardiac output, increased peripheral vascular resistance, and reduced total arterial compliance, but the hemodynamic pattern may be influenced by age.


Asunto(s)
Hemodinámica , Hipertensión/fisiopatología , Adulto , Arterias/fisiología , Presión Sanguínea , Monitoreo Ambulatorio de la Presión Arterial , Adaptabilidad , Ecocardiografía , Femenino , Frecuencia Cardíaca , Humanos , Hipertensión/etiología , Masculino , Persona de Mediana Edad , Visita a Consultorio Médico , Volumen Sistólico , Resistencia Vascular
10.
Eur Heart J ; 16(6): 866-8, 1995 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-7588934

RESUMEN

This is a report of a 63-year-old man who in the course of an inferior wall myocardial infarction developed a left ventricular aneurysm with communication to the right atrium and a haemodynamically significant intracardiac shunt. The unusual complication of a myocardial infarction was correctly diagnosed by transthoracic Doppler echocardiography, and later a successful surgical repair was done.


Asunto(s)
Ecocardiografía Doppler , Fístula/etiología , Aneurisma Cardíaco/etiología , Cardiopatías/diagnóstico por imagen , Cardiopatías/etiología , Infarto del Miocardio/complicaciones , Fístula/diagnóstico por imagen , Humanos , Masculino , Persona de Mediana Edad
11.
Acta Radiol ; 35(6): 590-6, 1994 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-7946684

RESUMEN

The study was an attempt to evaluate the benefit of intravascular ultrasound imaging (IVUS) as a supplement to follow-up angiography after endovascular stent implantation. A consecutive series of 15 patients underwent stent implantation in the peripheral or coronary arteries. Ten Palmaz stents, 3 Palmaz-Schatz stents and 2 Wallstents were used. After a period from 1 to 6 months (mean 3.2 months) follow-up angiography was performed. In 12 cases the angiography was combined with IVUS of the stent and the adjacent vessel segments. In one case IVUS failed due to the tortuous course of the vessel, in another case the stent was occluded, and in one case IVUS was considered too hazardous. In stents of diameter > or = 5 mm, ultrasound (US) did not reveal more information concerning vessel and stent diameter, stent stenosis and intraluminal surface contact than angiography alone. Smaller stents were insufficiently visualized by conventional radiologic methods. In small stents only IVUS permitted an exact stent identification and differentiation between stent stenosis and stenosis of the native vessel. At US imaging artifacts, caused by the highly reflectant metallic stent struts, interfered with the native vessel wall and partly obscured its structural details.


Asunto(s)
Arteriopatías Oclusivas/diagnóstico por imagen , Stents , Ultrasonografía Intervencional , Anciano , Angiografía , Arteriopatías Oclusivas/cirugía , Femenino , Humanos , Arteria Ilíaca/diagnóstico por imagen , Arteria Ilíaca/cirugía , Masculino , Persona de Mediana Edad , Vena Safena/diagnóstico por imagen , Vena Safena/cirugía , Arteria Subclavia/diagnóstico por imagen , Arteria Subclavia/cirugía , Grado de Desobstrucción Vascular
12.
J Am Soc Echocardiogr ; 6(3 Pt 1): 279-85, 1993.
Artículo en Inglés | MEDLINE | ID: mdl-8333976

RESUMEN

To assess whether aortic valve replacement (AVR) results in changes in the flow velocity distribution in the left ventricular outflow tract (LVOT), 10 patients undergoing AVR for aortic stenosis were studied. By extracting velocity information from color flow maps as digital data, instantaneous cross-sectional velocity profiles were constructed. Velocity profiles obtained 1 to 3 days before AVR were compared with recordings made 3 months later. The LVOT velocity profiles were variably skewed both before and after surgery, and no systematic or uniform changes could be detected after AVR. The highest velocities were most often localized in the region from the center of the outflow tract diameter toward the septum both before and after surgery. At the time of peak flow the ratio of the maximum to the cross-sectional mean velocity was 1.38 +/- 0.13 before and 1.39 +/- 0.08 after AVR (NS), and the ratio of the maximum to the mean velocity time integral was 1.47 +/- 0.10 before and 1.56 +/- 0.10 after (NS). We conclude that AVR in patients with aortic stenosis does not result in a change in LVOT velocity profiles that will influence stroke volume estimates with the Doppler technique.


Asunto(s)
Válvula Aórtica/cirugía , Velocidad del Flujo Sanguíneo , Ecocardiografía Doppler , Prótesis Valvulares Cardíacas , Función Ventricular Izquierda , Anciano , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/cirugía , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados
13.
Am J Cardiol ; 71(11): 944-8, 1993 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-8465786

RESUMEN

To assess the frequency and severity of intraventricular gradients after valve replacement for severe valvular aortic stenosis 25 patients (valve area 0.59 +/- 0.19 cm2) were studied serially with Doppler echocardiography on postoperative days 1, 2, 3, 5 and 7. Pulsed Doppler was used to search for increased intraventricular velocities. Mid-to-late systolic intraventricular velocities > or = 2 m/s were defined as intraventricular gradients. In 13 patients (52%) intraventricular gradients were found at least once during days 1 to 7 (group A) and were most frequent at day 3 (44%). The typical location of these velocities was at the midventricular level close to the septum. In 4 patients intraventricular gradients > 64 mm Hg were found. Left ventricular end-diastolic and end-systolic diameters recorded preoperatively were significantly smaller in group A than in the rest (43.6 +/- 5.4 vs 50 +/- 5.8 mm and 24.6 +/- 5.6 vs 33.1 +/- 7.3 mm, both p < 0.05) and the fractional shortening was significantly higher (44 +/- 9 vs 34 +/- 9%, p < 0.05). It is concluded that intraventricular gradients are frequent during the first week after valve replacement for severe aortic stenosis. These gradients are mostly mild and transient in nature, but significant gradients associated with clinical deterioration may occur. The risk of developing intraventricular gradients postoperatively may be predicted at a preoperative echocardiographic examination, and patients with a small left ventricular cavity size and maintained contractility are at particular risk.(ABSTRACT TRUNCATED AT 250 WORDS)


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Bioprótesis , Prótesis Valvulares Cardíacas , Sístole , Función Ventricular/fisiología , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/fisiopatología , Velocidad del Flujo Sanguíneo/efectos de los fármacos , Presión Sanguínea/efectos de los fármacos , Dopamina/farmacología , Ecocardiografía Doppler , Femenino , Frecuencia Cardíaca , Humanos , Masculino , Persona de Mediana Edad , Contracción Miocárdica/efectos de los fármacos , Periodo Posoperatorio , Estudios Prospectivos
14.
Tidsskr Nor Laegeforen ; 113(2): 190-2, 1993 Jan 20.
Artículo en Noruego | MEDLINE | ID: mdl-8430398

RESUMEN

Organization of anticoagulation therapy in general practice is described on the basis of data from 56 general practitioners interviewed by questionnaire. The average number of patients controlled by each practitioner was 12.0, and 52% of the general practitioners performed the analyses themselves. In municipalities with a local hospital only 13% of the general practitioners performed the analyses themselves, compared with 75% in municipalities without a hospital. The average weekly number of Thrombotests performed by each practitioner was 12.2. When an external laboratory was used 88% were contacted earlier in the case of International Normalized Ratio (INR) > 4.8 while this was uncommon (12%) in the case of International Normalized Ratio < 2.0. We discuss the advantages and possible disadvantages of near testing of patients on oral anticoagulation therapy.


Asunto(s)
Anticoagulantes/administración & dosificación , Medicina Familiar y Comunitaria/organización & administración , Terapia Trombolítica/métodos , Medicina Familiar y Comunitaria/normas , Humanos , Noruega , Tiempo de Protrombina , Encuestas y Cuestionarios
15.
Am Heart J ; 125(1): 138-46, 1993 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-8417509

RESUMEN

Exercise Doppler echocardiography was used to assess hemodynamics in 25 patients with a < or = 21 mm aortic valve prosthesis (14 with a Medtronic-Hall 21 mm valve, three with a Medtronic-Hall 20 mm valve, three with a Sorin 21 mm valve, one with a Duromedics 21 mm valve, and four with a Carpentier-Edwards 21 mm valve). A symptom-limited upright bicycle exercise test was performed, and Doppler gradients were recorded during exercise. Gradients increased with exercise from 30 +/- 8/16 +/- 4 mm Hg (peak/mean) at rest to 46 +/- 12/24 +/- 7 mm Hg during exercise; both p < 0.001. Mean exercise gradient exceeded 30 mm Hg in five patients, and the highest mean gradient recorded was 37 mm Hg. Within the group of mechanical valves, gradients at exercise were similar for different types of valves. A linear relationship was found between gradients at rest and during exercise (peak r = 0.75, mean r = 0.77; both p < 0.001). Additional findings were midventricular velocities exceeding 1.5 m/sec in late systole in 10 patients (40%) and intraventricular flow (> or = 0.2 m/sec) toward the apex during isovolumic relaxation in 11 patients (44%). The patients with these velocity patterns had significantly smaller left ventricular cavities (end-diastolic diameter 39.8 +/- 4.8 vs 46.5 +/- 4.2 mm, p < 0.01; end-systolic diameter 24.2 +/- 3.0 vs 28.5 +/- 4.5 mm, p = 0.013).(ABSTRACT TRUNCATED AT 250 WORDS)


Asunto(s)
Bioprótesis , Ecocardiografía Doppler , Prueba de Esfuerzo , Prótesis Valvulares Cardíacas , Anciano , Análisis de Varianza , Válvula Aórtica/diagnóstico por imagen , Bioprótesis/estadística & datos numéricos , Ecocardiografía Doppler/métodos , Ecocardiografía Doppler/estadística & datos numéricos , Prueba de Esfuerzo/métodos , Prueba de Esfuerzo/estadística & datos numéricos , Femenino , Prótesis Valvulares Cardíacas/estadística & datos numéricos , Hemodinámica , Humanos , Masculino , Persona de Mediana Edad , Postura/fisiología , Diseño de Prótesis , Análisis de Regresión , Descanso
16.
Scand J Thorac Cardiovasc Surg ; 27(2): 87-92, 1993.
Artículo en Inglés | MEDLINE | ID: mdl-8211010

RESUMEN

To assess the value of two-dimensional echocardiography (2D ECHO) for predicting prosthetic aortic valve size, the diameter of the aortic annulus was measured before implantation of a Medtronic-Hall valve in 24 patients and a Carpentier-Edwards supra-annular valve in 34. In the Medtronic-Hall group, the average prosthesis size was similar to the average annulus diameter, i.e. 23.2 +/- 2.1 vs 23.0 +/- 3.4 mm (NS), 95% confidence interval for the difference -1.0-0.7 mm. In the Carpentier-Edwards group the corresponding figures were 23.5 +/- 2.1 and 22.0 +/- 2.3 mm (p < 0.001), with 95% confidence interval 0.9-2.0 mm. Correlation between annulus diameter indicated by preoperative 2D ECHO and prosthesis size was stronger in the Medtronic-Hall (r = 0.88, p < 0.001) than in the Carpentier-Edwards group (r = 0.73, p < 0.001). The authors conclude that prosthetic aortic valve size may be accurately predicted by 2D ECHO, with Medtronic-Hall valve size similar to, and Carpentier-Edwards prostheses on average 1-2 mm larger than the 2D ECHO-estimated annulus diameter.


Asunto(s)
Bioprótesis , Ecocardiografía Doppler , Prótesis Valvulares Cardíacas , Adulto , Anciano , Anciano de 80 o más Años , Válvula Aórtica/anatomía & histología , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiología , Femenino , Hemodinámica , Humanos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Cuidados Posoperatorios , Valor Predictivo de las Pruebas , Cuidados Preoperatorios , Estudios Prospectivos , Diseño de Prótesis
17.
Am J Cardiol ; 70(2): 240-6, 1992 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-1626514

RESUMEN

To assess resting hemodynamics of an unselected group of patients with prostheses or bioprostheses sized less than or equal to 21 mm implanted into the aortic valve position during a 7-year period, 46 of 50 eligible patients were examined by Doppler echocardiography. The valves were Carpentier-Edwards (CE) supraannular 21 mm (n = 8), Medtronic-Hall (MH) 20 mm (n = 8) and 21 mm (n = 21), and the rest (n = 9) were other valves with only 1 to 3 patients in each group. Gradients, valve areas and dimensionless obstruction indexes (ratio of subvalvular/valvular velocities and velocity time integrals) were compared. By analysis of variance, gradients did not differ significantly between the CE supraannular 21 mm, the MH 20 and 21 mm prostheses (peak/mean 25 +/- 8/14 +/- 5, 31 +/- 13/16 +/- 6 and 25 +/- 10/13 +/- 5 mm Hg; p = not significant). Only 2 patients had a mean gradient greater than 25 mm Hg. The valve area was slightly larger for the MH 21 mm group compared with the CE supraannular 21 mm group (1.34 +/- 0.15 vs 1.16 +/- 0.14 cm2, p less than 0.05). The dimensionless obstruction indexes did not differ (CE supraannular 21 mm 0.36 +/- 0.07/0.40 +/- 0.07 (velocities/velocity time integrals), MH 20 mm 0.40 +/- 0.12/0.47 +/- 0.12, MH 21 mm 0.38 +/- 0.05/0.44 +/- 0.06; p = not significant).(ABSTRACT TRUNCATED AT 250 WORDS)


Asunto(s)
Bioprótesis , Ecocardiografía Doppler , Prótesis Valvulares Cardíacas , Adulto , Anciano , Anciano de 80 o más Años , Análisis de Varianza , Válvula Aórtica/fisiopatología , Bioprótesis/estadística & datos numéricos , Ecocardiografía Doppler/estadística & datos numéricos , Femenino , Prótesis Valvulares Cardíacas/estadística & datos numéricos , Hemodinámica/fisiología , Humanos , Masculino , Persona de Mediana Edad , Diseño de Prótesis , Falla de Prótesis , Reproducibilidad de los Resultados
18.
J Am Soc Echocardiogr ; 4(6): 645-7, 1991.
Artículo en Inglés | MEDLINE | ID: mdl-1760190

RESUMEN

A case with impeded disc movement caused by thrombus formation in a Medtronic-Hall aortic valve prosthesis is reported. A correct diagnosis, including both mechanism and severity of the prosthesis failure, was established by Doppler echocardiography. The patient was promptly referred for surgery without invasive or other supplementary investigations.


Asunto(s)
Válvula Aórtica , Ecocardiografía Doppler , Prótesis Valvulares Cardíacas , Complicaciones Posoperatorias , Trombosis/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Femenino , Humanos , Persona de Mediana Edad , Reoperación , Trombosis/cirugía
19.
Am J Cardiol ; 67(9): 869-72, 1991 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-2011987

RESUMEN

In 131 patients undergoing aortic valve replacement (53 bioprostheses, 78 mechanical), the pressure decrease across the prosthesis was recorded with Doppler ultrasound at a baseline study early postoperatively (mean 11 +/- 5 days) and compared with a repeat measurement 3 to 5 months later. At baseline the hemodynamic state was markedly different, with increased heart rate (89 +/- 14 vs. 74 +/- 13 beats/min, p less than 0.001) and decreased left ventricular ejection time index (367 +/- 21 vs 390 +/- 22, p less than 0.001). A minor and clinically insignificant decrease in pressure decrease with time was found. The 95% confidence interval for the difference was 0.2 to 3.0 and 0.2 to 1.7 mm Hg for the peak and the mean pressure decrease, respectively. The change in pressure decrease was statistically significant for bioprostheses (mean 16 +/- 5 vs 14 +/- 4 mm Hg, p less than 0.01) and smaller (less than or equal to 23 mm) valves (mean 17 +/- 4 vs 15 +/- 4 mm Hg, p less than 0.01), whereas no significant changes were found for mechanical valves or valves of a larger size. The change in mean pressure decrease from baseline to the second examination was within +/- 5 mm Hg for 82% of patients. It is concluded that despite a different hemodynamic state in the early postoperative period, the pressure decrease across aortic valve prostheses obtained at this time can be used as a reference for later comparison.


Asunto(s)
Válvula Aórtica , Presión Sanguínea/fisiología , Ecocardiografía Doppler , Prótesis Valvulares Cardíacas , Válvula Aórtica/fisiopatología , Bioprótesis , Velocidad del Flujo Sanguíneo/fisiología , Intervalos de Confianza , Humanos , Variaciones Dependientes del Observador , Periodo Posoperatorio , Análisis de Regresión , Reproducibilidad de los Resultados , Volumen Sistólico/fisiología , Factores de Tiempo , Función Ventricular Izquierda/fisiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...