1.
Med Phys ; 2024 Jun 26.
Artículo en Inglés | MEDLINE | ID: mdl-38922963

RESUMEN

BACKGROUND: Historically, [131I]I has been a common isotope in radionuclide therapy, with [177Lu]Lu-labelled radiopharmaceuticals now seeing a surge in use. These can include no-carrier-added or carrier-added [177Lu]Lu with slight impurities of [177mLu]Lu with a significantly longer half-life than [131I]I. Wastewater from therapy wards can contain a mixture of these radioisotopes. In some countries, national regulations require wastewater to be stored in dedicated systems before it is discharged into the public sewage system. To fulfill legal requirements, the nuclide specific activity concentration must be verified. PURPOSE: We evaluate a method for determining the activity concentration of [177mLu]Lu /[177Lu]Lu at equilibrium and [131I]I in pure and mixed samples in order to prove that the determined values are reliably below the limits for release. METHODS: We analysed the emitted energy spectrum of 1 L samples with a wastewater counter using an energy window-based approach by evaluating measurements from two different time points. Based on the law of decay and the time and energy-dependent measured values, equation systems were set up to calculate the count rates for [131I]I and [177mLu]Lu, which were converted into activity concentration using calibration factors. RESULTS: There is strong linear correlation between the nominal and determined activity concentrations (correlation coefficients R = 0.99; coefficient of determinations R2 = 0.99). We underestimate the actual activity concentration by a median of -1.4% for [177mLu]Lu and overestimate the activity concentration for [131I]I by a median of 7.1%. CONCLUSION: We show that an undercut of the clearance levels for material release is measurable. We analyse and determine activity concentrations of mixed samples consisting of [131I]I and [177mLu]Lu/[177Lu]Lu in equilibrium. The method is simple to implement using a conventional wastewater counter, however with a slightly increased effort, as two samples and measurements are required. The methodology can be adapted for the analysis of other nuclide mixtures.

2.
Med Phys ; 50(1): 590-599, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-36208077

RESUMEN

BACKGROUND: Nuclear medicine therapies using [177 Lu]Lu-labeled radiopharmaceuticals have increased significantly in recent years. Some of these radiopharmaceuticals contain long-lived impurities of [177m Lu]Lu. Identification of this specific contamination and its quantification is important in different scenarios. PURPOSE: In this study, standard measurement hardware used for handling radioisotopes was evaluated for the measurement of [177m Lu]Lu and [177 Lu]Lu at equilibrium. Device-specific detection limits (LODs) for [177m Lu]Lu were determined according to international standards and then validated. METHODS: The LODs were determined according to the international standard ISO 11929-1 for [177m Lu]Lu for five identical portable contamination monitors (PCMs), a wastewater counter (WWC), and a release counter system (RCS) at different measuring times. Subsequent activity measurements of the defined samples were used to validate the linearity of the measurement instruments down to the LOD for each system. RESULTS: The average LOD across all PCMs was 0.249 ± 0.009 and 0.129 ± 0.005 Bq/cm2 for 10 and 30 s measurements, respectively. The LODs of WWC varied between 3.3 and 4.7 Bq/L for measurement times of 300 s and 0.8-1.3 Bq/L for 3600 s depending on the energy window studied. The LOD of the RCS depended on the container volume and was 0.08 Bq/g for the 50 L container at 60 s measurement. The measurements for all examined devices were linear down to the LOD (correlation coefficient R ≥ 0.96; coefficient of determination R2  ≥ 0.92). CONCLUSIONS: All investigated measuring instruments (PCM, WWC, RCS) were suitable for the determination of [177m Lu]Lu at equilibrium, and their specific LODs were determined. Based on the measurements performed, activity is overestimated; however, this is tolerable because assumptions and measurements in the context of radiation protection should be conservative.


Asunto(s)
Medicina Nuclear , Radiofármacos , Lutecio , Radioisótopos , Estándares de Referencia
3.
EJNMMI Phys ; 8(1): 57, 2021 Jul 30.
Artículo en Inglés | MEDLINE | ID: mdl-34328565

RESUMEN

BACKGROUND: The introduction of hybrid SPECT/CT devices enables quantitative imaging in SPECT, providing a methodological setup for quantitation using SPECT tracers comparable to PET/CT. We evaluated a specific quantitative reconstruction algorithm for SPECT data using a 99mTc-filled NEMA phantom. Quantitative and qualitative image parameters were evaluated for different parametrizations of the acquisition and reconstruction protocol to identify an optimized quantitative protocol. RESULTS: The reconstructed activity concentration (ACrec) and the signal-to-noise ratio (SNR) of all examined protocols (n = 16) were significantly affected by the parametrization of the weighting factor k used in scatter correction, the total number of iterations and the sphere volume (all, p < 0.0001). The two examined SPECT acquisition protocols (with 60 or 120 projections) had a minor impact on the ACrec and no significant impact on the SNR. In comparison to the known AC, the use of default scatter correction (k = 0.47) or object-specific scatter correction (k = 0.18) resulted in an underestimation of ACrec in the largest sphere volume (26.5 ml) by - 13.9 kBq/ml (- 16.3%) and - 7.1 kBq/ml (- 8.4%), respectively. An increase in total iterations leads to an increase in estimated AC and a decrease in SNR. The mean difference between ACrec and known AC decreased with an increasing number of total iterations (e.g., for 20 iterations (2 iterations/10 subsets) = - 14.6 kBq/ml (- 17.1%), 240 iterations (24i/10s) = - 8.0 kBq/ml (- 9.4%), p < 0.0001). In parallel, the mean SNR decreased significantly from 2i/10s to 24i/10s by 76% (p < 0.0001). CONCLUSION: Quantitative SPECT imaging is feasible with the used reconstruction algorithm and hybrid SPECT/CT, and its consistent implementation in diagnostics may provide perspectives for quantification in routine clinical practice (e.g., assessment of bone metabolism). When combining quantitative analysis and diagnostic imaging, we recommend using two different reconstruction protocols with task-specific optimized setups (quantitative vs. qualitative reconstruction). Furthermore, individual scatter correction significantly improves both quantitative and qualitative results.

4.
EJNMMI Phys ; 8(1): 15, 2021 Feb 17.
Artículo en Inglés | MEDLINE | ID: mdl-33595735

RESUMEN

BACKGROUND: SPECT-CT using radiolabeled phosphonates is considered a standard for assessing bone metabolism (e.g., in patients with osteoarthritis of knee joints). However, SPECT can be influenced by metal artifacts in CT caused by endoprostheses affecting attenuation correction. The current study examined the effects of metal artifacts in CT of a specific endoprosthesis design on quantitative hybrid SPECT-CT imaging. The implant was positioned inside a phantom homogenously filled with activity (955 MBq 99mTc). CT imaging was performed for different X-ray tube currents (I = 10, 40, 125 mA) and table pitches (p = 0.562 and 1.375). X-ray tube voltage (U = 120 kVp) and primary collimation (16 × 0.625 mm) were kept constant for all scans. The CT reconstruction was performed with five different reconstruction kernels (slice thickness, 1.25 mm and 3.75 mm, each 512 × 512 matrix). Effects from metal artifacts were analyzed for different CT scans and reconstruction protocols. ROI analysis of CT and SPECT data was performed for two slice positions/volumes representing the typical locations for target structures relative to the prosthesis (e.g., femur and tibia). A reference region (homogenous activity concentration without influence from metal artifacts) was analyzed for comparison. RESULTS: Significant effects caused by CT metal artifacts on attenuation-corrected SPECT were observed for the different slice positions, reconstructed slice thicknesses of CT data, and pitch and CT-reconstruction kernels used (all, p < 0.0001). Based on the optimization, a set of three protocols was identified minimizing the effect of CT metal artifacts on SPECT data. Regarding the reference region, the activity concentration in the anatomically correlated volume was underestimated by 8.9-10.1%. A slight inhomogeneity of the reconstructed activity concentration was detected inside the regions with a median up to 0.81% (p < 0.0001). Using an X-ray tube current of 40 mA showed the best result, balancing quantification and CT exposure. CONCLUSION: The results of this study demonstrate the need for the evaluation of SPECT-CT protocols in prosthesis imaging. Phantom experiments demonstrated the possibility for quantitative SPECT-CT of bone turnover in a specific prosthesis design. Meanwhile, a systematic bias caused by metal implants on quantitative SPECT data has to be considered.

5.
Nuklearmedizin ; 59(4): 308-315, 2020 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-32215881

RESUMEN

AIM: The study examined the local dose distribution as well as the time course of skin exposure of hand and fingers from [68Ga]Ga-DOTA-NOC synthesis using a self-shielded synthesis module. METHODS: A compact calibrated electronic dosimeter (ED) with a miniaturized probe was used for real-time measurements of skin dose equivalent Hp (0.07) (reference point: left and right index finger). A time resolved assessment of exposure during radiotracer production was performed. Additionally, thermoluminescence dosimeters (TLD) were used to determine local dose distribution for five different positions (e. g. fingertips). Cumulated Hp (0.07) estimated by ED was analysed and correlated with the measurements obtained by a TLD positioned close to the ED. RESULTS: The cumulative skin exposure from the production process measured by ED, was 74.7 ±â€Š32.7 µSv/GBq and 40.1 ± 14.3 µSv/GBq for the right and left hand, respectively. The exposure recorded by the ED was in the average 19.4 % ±â€Š40.0 % (median = 21.3 %) lower compared to the results from TLD. Highest exposure was recorded during synthesis (guided hand: 24.5 ±â€Š12.2 µSv/GBq) and measuring of product yield including preparation of probes for quality control (guided hand: 36.1 ±â€Š12.7 µSv/GBq). The highest local exposure was measured by a TLD close to the tip of the index finger of the guiding hand (range: 773-1257 µS/GBq). CONCLUSION: The chosen methodology using ED, proved to be a good concept for identifying procedure steps with an increased exposure level and to determine the time course of skin exposure and to identify procedure steps for further optimization of handling. Furthermore, miniaturized electronic dosimeters may be used for online surveillance of local exposure rates at hands and fingers.


Asunto(s)
Dedos/efectos de la radiación , Mano/efectos de la radiación , Compuestos Organometálicos , Piel/efectos de la radiación , Humanos , Protección Radiológica , Dosimetría Termoluminiscente
6.
Health Phys ; 114(1): 58-63, 2018 01.
Artículo en Inglés | MEDLINE | ID: mdl-29049048

RESUMEN

In radioembolic therapy (RET) of hepatic malignancies using yttrium-90 (Y)-labeled resin microspheres, radiation protection is primarily concerned with avoiding contamination by radioactive spheres. However, as Y is bound to the microsphere surface by a potentially reversible ion-exchange process, the aim of this study was to assess the extent of the potential excreted activity in urine. After RET with Y-labeled resin-based microspheres, urinary excretion of free Y was prospectively analyzed in 51 interventions (n = 45 patients) by sampling urine over 48 h (two 24-h intervals) consecutively. The measured urinary concentration of Y, normalized to the administered microsphere activity, was a median of 58.5 kBq L GBq (range = 3.5-590.9 kBq L GBq) and 17.8 kBq L GBq (1.8-58.8 kBq L GBq) for the first and second 24-h periods after administration, respectively (p ≤ 0.0001, F = 28.4, result from ANOVA). The total excreted activity significantly decreased (p ≤ 0.0001) from a median of 72.5 kBq in the first 24-h period to a median of 22.1 kBq in the second 24-h period. Urinary excretion of free Y after resin-based RET occurs for a longer period and at a higher activity excretion than previously published, which has to be considered when patients are either hospitalized or return home after RET. Existing approaches for patient hospitalization, especially in temporary radiation protection areas, justified by the previously reported lower excretion rate, should be re-evaluated, and as a consequence, the current product safety information and handling recommendations for Y-labeled resin-based microspheres may need to be revised.


Asunto(s)
Braquiterapia/métodos , Neoplasias Hepáticas/orina , Microesferas , Protección Radiológica/métodos , Radiofármacos/orina , Radioisótopos de Itrio/orina , Adulto , Anciano , Femenino , Hospitalización , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Contaminantes Radiactivos del Agua
7.
PLoS One ; 12(11): e0187570, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-29107992

RESUMEN

In peptide receptor radionuclide therapy (PRRT) of patients with neuroendocrine neoplasias (NENs), intratherapeutic dosimetry is mandatory for organs at risk (e.g. kidneys) and tumours. We evaluated commercial dosimetry software (Dosimetry Toolkit) using varying imaging scenarios, based on planar and/or tomographic data, regarding the differences in calculated organ/tumour doses and the use for clinical routines. A total of 16 consecutive patients with NENs treated by PRRT with 177Lu-DOTATATE were retrospectively analysed. Single-photon emission computed tomography (SPECT)/low-dose computed tomography (CT) of the thorax and abdomen and whole body (WB) scintigraphy were acquired up to 7 days p.i. (at a maximum of five imaging time points). Different dosimetric scenarios were evaluated: (1) a multi-SPECT-CT scenario using SPECT/CT only; (2) a planar scenario using WB scintigraphy only; and (3) a hybrid scenario using WB scintigraphy in combination with a single SPECT/low-dose CT. Absorbed doses for the kidneys, liver, spleen, lungs, bladder wall and tumours were calculated and compared for the three different scenarios. The mean absorbed dose for the kidneys estimated by the multi-SPECT-CT, the planar and the hybrid scenario was 0.5 ± 0.2 Sv GBq-1, 0.8 ± 0.4 Sv GBq-1 and 0.6 ± 0.3 Sv GBq-1, respectively. The absorbed dose for the residual organs was estimated higher by the planar scenario compared to the multi-SPECT-CT or hybrid scenario. The mean absorbed tumour doses were 2.6 ± 1.5 Gy GBq-1 for the multi-SPECT-CT, 3.1 ± 2.2 Gy GBq-1 for the hybrid scenario and 5.3 ± 6.3 Gy GBq-1 for the planar scenario. SPECT-based dosimetry methods determined significantly lower kidney doses than the WB scintigraphy-based method. Dosimetry based completely on SPECT data is time-consuming and tedious. Approaches combining SPECT/CT and WB scintigraphy have the potential to ensure compromise between accuracy and user-friendliness.


Asunto(s)
Lutecio/uso terapéutico , Radiofármacos/uso terapéutico , Receptores de Péptidos/metabolismo , Programas Informáticos , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Lutecio/farmacocinética , Masculino , Persona de Mediana Edad , Imagen Multimodal , Radiofármacos/farmacocinética , Distribución Tisular , Tomografía Computarizada de Emisión de Fotón Único , Tomografía Computarizada por Rayos X
8.
Nuklearmedizin ; 56(3): 69-72, 2017 Jun 13.
Artículo en Inglés | MEDLINE | ID: mdl-28383088

RESUMEN

AIM: 223Radium-dichloride (223Ra) administration is an upcoming therapeutic option in patients with castration-resistant metastatic prostate cancer (mCRPC), whose renal and faecal excretion of 223Ra has been primarily estimated from data of a phase-I clinical trial in patients with normal renal function. In the rare case of concomitant renal insufficiency requiring haemodialysis (HD), an estimation of the contamination of dialysate would be beneficial. METHODS: The excretion of 223Ra and its concentration in the dialysate in a patient with mCRPC and end-stage renal disease was examined for six consecutive treatment cycles. Dialysate samples were measured using a commercial system with NaI-scintillation detector. RESULTS: HD showed a residual activity level in the remaining dialysate. The excreted activity was a median of 46.1 kBq (range = 42.0- 83.4 kBq) and 11.2 kBq (range = 8.4- 19.9 kBq) for the first (24 h post injection p.i.) and second HD (96 h p.i.), respectively. The activity concentration decreased significantly from a median of 4.18 kBq/l (range = 2.98-5.14 kBq/l) to 0.85 kBq/l (range = 0.69- 1.31 kBq/l, p < 0.0001). For all consecutive time points, the activity concentration further decreased significantly (p < 0.0001). The activity concentration of dialysate from HD performed 125.4 h p.i. [95 % confidence interval = 120.5-130.4 h p.i.] reached the threshold for unrestricted waste disposal. CONCLUSION: The observed extraction of 223Ra by HD exceeded the data determined from the phase-I study. The activity concentration in the dialysate observed for the first HD's p.i. was above the threshold for unrestricted disposal of radioactive waste in Germany. Therefore, the specific requirement for waste handling has to be followed to fulfil the radiation protection regulations.


Asunto(s)
Neoplasias Óseas/radioterapia , Neoplasias Óseas/secundario , Neoplasias de la Próstata Resistentes a la Castración/patología , Neoplasias de la Próstata Resistentes a la Castración/radioterapia , Radio (Elemento)/aislamiento & purificación , Radio (Elemento)/uso terapéutico , Diálisis Renal/métodos , Eliminación de Componentes Sanguíneos/métodos , Soluciones para Diálisis/análisis , Soluciones para Diálisis/química , Humanos , Masculino , Persona de Mediana Edad , Dosis de Radiación , Protección Radiológica/métodos , Radioisótopos/sangre , Radioisótopos/aislamiento & purificación , Radioisótopos/uso terapéutico , Radiofármacos/sangre , Radiofármacos/aislamiento & purificación , Radiofármacos/uso terapéutico , Radio (Elemento)/sangre , Resultado del Tratamiento
9.
J Shoulder Elbow Surg ; 25(4): e96-103, 2016 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-26652693

RESUMEN

BACKGROUND: This study evaluates bone remodeling processes in the proximal humerus induced by the implantation of a stemless shoulder prosthesis with regard to time of response and type and extent of bone turnover. METHODS: Twenty-eight patients with primary osteoarthritis of the shoulder undergoing a stemless shoulder arthroplasty were prospectively evaluated. The local metabolic bone activity in 5 regions of interest (ROIs 1-5) around the implant and in 1 reference region (ROI ref.) in the humeral diaphysis was analyzed after the application of technetium Tc 99m DPD using single-photon emission computed tomography integrated with multidetector computed tomography (SPECT/CT). The study cohort was divided into 4 groups according to the timing of the most recent follow-up appointment to evaluate the primary osseointegrative response after surgery. The bone uptake values were expressed in target (ROIs 1-5) to nontarget (ROI ref.) ratios. RESULTS: No difference within the 4 subgroups with respect to the time of local metabolic bone activity in the ROIs was found at 90 days after surgery. The highest initial metabolic activity and most temporal modifications were found in ROI 1, which was localized in the superior segment of the stem. CONCLUSIONS: SPECT/CT data suggest that the primary osseointegration of a stemless shoulder prosthesis is almost completed 3 months after implantation. Variations in metabolic activity pattern in the ROIs during follow-up may be caused by different loading conditions of the bone.


Asunto(s)
Artroplastia de Reemplazo/instrumentación , Oseointegración , Osteoartritis/cirugía , Articulación del Hombro/diagnóstico por imagen , Tomografía Computarizada por Tomografía Computarizada de Emisión de Fotón Único , Anciano , Remodelación Ósea , Femenino , Humanos , Prótesis Articulares , Masculino , Persona de Mediana Edad , Osteoartritis/fisiopatología , Estudios Prospectivos , Diseño de Prótesis , Articulación del Hombro/fisiopatología , Articulación del Hombro/cirugía
10.
BMC Med Imaging ; 15: 18, 2015 Jun 02.
Artículo en Inglés | MEDLINE | ID: mdl-26033371

RESUMEN

BACKGROUND: The diagnosis of hip pain after total hip replacement (THR) represents a highly challenging question that is of increasing concern to orthopedic surgeons. This retrospective study assesses bone scintigraphy with Hybrid SPECT/CT for the diagnosis of painful THR in a selected cohort of patients. METHODS: Bone SPECT/CT datasets of 23 patients (mean age 68.9 years) with a painful hip after THR were evaluated. Selection of the patients required an inconclusive radiograph, normal serum levels of inflammatory parameters (CRP and ESR) or a negative aspiration of the hip joint prior to the examination. The standard of reference was established by an interdisciplinary adjudication-panel using all imaging data and clinical follow-up data (>12 month). Pathological and physiological uptake patterns were defined and applied. RESULTS: The cause of pain in this study group could be determined in 18 out of 23 cases. Reasons were aseptic loosening (n = 5), spine-related (n = 5), heterotopic ossification (n = 5), neuronal (n = 1), septic loosening (n = 1) and periprosthetic stress fracture (n = 1). In (n = 5) cases the cause of hip pain could not be identified. SPECT/CT imaging correctly identified the cause of pain in (n = 13) cases, in which the integrated CT-information led to the correct diagnosis in (n = 4) cases, mainly through superior anatomic correlation. Loosening was correctly assessed in all cases with a definite diagnosis. CONCLUSIONS: SPECT/CT of THA reliably detects or rules out loosening and provides valuable information about heterotopic ossifications. Furthermore differential diagnoses may be detected with a whole-body scan and mechanical or osseous failure is covered by CT-imaging. SPECT/CT holds great potential for imaging-based assessment of painful prostheses.


Asunto(s)
Artralgia/diagnóstico , Artralgia/etiología , Artroplastia de Reemplazo de Cadera/efectos adversos , Articulación de la Cadera/diagnóstico por imagen , Tomografía Computarizada de Emisión de Fotón Único/métodos , Anciano , Cementos para Huesos , Femenino , Humanos , Masculino , Imagen Multimodal/métodos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Tomografía Computarizada por Rayos X/métodos , Resultado del Tratamiento
12.
Acta Orthop Scand ; 74(1): 85-8, 2003 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-12635799

RESUMEN

A proprioceptive deficit is an important determinant of disability in various shoulder disorders, such as instability and osteoarthrosis. In 15 patients with impingement syndrome stage II (Neer 1983), who were treated by arthroscopic subacromial decompression, we measured movement sense by determining threshold levels for the perception of motion of the shoulder. The patients were placed in a specially designed chair allowing continuous passive motion of the shoulder joint, while avoiding cutaneous, auditory and visual stimuli. To assess movement detection thresholds, passive abduction movements of the shoulder were performed at a starting angle of 60 degrees, an amplitude of 10 degrees and an angular velocity of 1.3 degrees/s. Before surgery, all patients had higher threshold levels for the perception of motion in their affected shoulders then in the other side. After decompression, proprioception had improved on the decompressed side, but was unchanged on the other side.


Asunto(s)
Descompresión Quirúrgica , Cinestesia , Síndrome de Abducción Dolorosa del Hombro/fisiopatología , Síndrome de Abducción Dolorosa del Hombro/cirugía , Adulto , Artroscopía , Descompresión Quirúrgica/métodos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Terapia Pasiva Continua de Movimiento , Síndrome de Abducción Dolorosa del Hombro/rehabilitación