1.
J Pharm Biomed Anal ; 224: 115153, 2023 Feb 05.
Artículo en Inglés | MEDLINE | ID: mdl-36423496

RESUMEN

A satellite laboratory "toolkit" consisting of a handheld Raman spectrometer, portable direct analysis in real-time mass spectrometer (DART-MS) and portable Fourier transform infrared (FT-IR) spectrometer was employed to examine 926 pharmaceutical, unknown and dietary supplement products collected at an international mail facility (IMF) for the presence of declared and undeclared active pharmaceutical ingredients (APIs) over the course of 68 working days. The toolkit successfully identified over 650 APIs, including over 200 unique APIs, using two or more devices. The performance of each individual device, and toolkit as a whole, were evaluated on all products and a subset of the products was forwarded to full-service laboratories for confirmatory analysis to determine false positive and false negative rates of the toolkit. The subset consisted of seven negative items (those not found to contain APIs using the toolkit) and 124 positive items (those found to contain at least one API using the toolkit). Overall, no false positives were detected in the negative items and only four false negatives and five false positives were detected in the positive items. Regarding the positive items, 119 of the 124 items were found to contain at least one API using at least two toolkit devices; each of these APIs were confirmed by a full-service laboratory. Furthermore, 90.2% of the APIs found by confirmatory laboratory analysis were detected by at least two toolkit devices. Based on these metrics and the fact that no false positives were detected by more than one device, it was concluded that when the toolkit detects and subsequently verifies/confirms an API using two or more devices, the results are as reliable as those generated by a full-service laboratory.


Asunto(s)
Laboratorios , Servicios Postales , Análisis de Fourier , Espectroscopía Infrarroja por Transformada de Fourier , Preparaciones Farmacéuticas
2.
J Pharm Biomed Anal ; 203: 114183, 2021 Sep 05.
Artículo en Inglés | MEDLINE | ID: mdl-34098507

RESUMEN

A "toolkit" consisting of a handheld Raman spectrometer equipped with a 1064 nm laser, a portable Fourier transform infrared (FT-IR) spectrometer and a portable direct analysis in real-time mass spectrometer (DART-MS) was employed in a laboratory setting to examine 82 representative products collected during a nationwide mail blitz for the presence of APIs. These results were compared to those obtained using laboratory-based methods; 8 of the products were not found to contain APIs and 74 of the products were found to contain a total of 88 APIs (65 of the 88 APIs were unique). The individual performance of each device and combined performance of the three-device toolkit were evaluated with regard to true positives, true negatives, false positives and false negatives. Using this toolkit, 81 (92.0 %) of the APIs were detected by at least one technique and 47 (64.8 %) of the APIs were detected by at least two techniques. Seven false negatives (8.0 %) were encountered and while the toolkit yielded 12 false positives, no false positives were detected by more than one technique. Overall, this study demonstrated that when the toolkit detects an API using two or more devices, the results are as reliable as those generated by a full-service laboratory.


Asunto(s)
Preparaciones Farmacéuticas , Servicios Postales , Espectroscopía Infrarroja por Transformada de Fourier
3.
J Forensic Sci ; 65(4): 1274-1279, 2020 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-31986222

RESUMEN

This study describes the performance of handheld Raman devices for determining whether suspect pharmaceutical tablets declared to contain controlled substances were consistent with authentic (CWA) or not consistent with authentic (NCWA) tablets using a simple, rapid, field-friendly method capable of being used by nonexperts. Twenty-five authentic products and 84 known NCWA tablets were examined using three "parent" devices for a total of 327 analyses. On average, the parent devices yielded a true pass rate of 100%, a true fail rate of 98.4%, a false pass rate of 1.6%, and a false fail rate of 0%. The methods/libraries were then transferred to 13 identical "daughter" devices, which were used to examine 10 suspect finished dosage forms in duplicate (six known NCWA tablets and four authentic tablets) for a total of 260 measurements. On average, the daughter devices had a true pass rate of 100%, a true fail rate of 95.5%, a false pass rate of 4.5%, and a false fail rate of 0.0%. These data demonstrate that the parent-daughter electronic transfer method was successful, which permits the ability to develop methods in the laboratory that can be seamlessly pushed out to field devices. The methods can then be used to (i) prioritize samples for additional testing using other more time-consuming laboratory-based techniques needed to detect and quantify active ingredients and (ii) help support the interdiction of dangerous tablets at ports of entry, thereby preventing them from reaching the supply chain.


Asunto(s)
Sustancias Controladas/análisis , Medicamentos Falsificados/química , Espectrometría Raman , Comprimidos/química , Química Farmacéutica/métodos , Humanos
4.
J Forensic Sci ; 60(4): 1078-84, 2015 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-25782994

RESUMEN

Suspect hypodermic needles and syringes were seized from an unlicensed individual who was allegedly injecting patients with silicone (polydimethylsiloxane [PDMS]) for cosmetic enhancement. Since control syringe barrels and needles often contain an interfering PDMS lubricant, a risk for false positives of foreign PDMS exists. The focus of this report was to minimize this risk and determine a quick and reliable test for the presence of blood in PDMS matrices. Using ATR-FT-IR spectroscopy, the risk for false-positive identification of foreign PDMS was reduced by (i) overfilling the sampling aperture to prevent spectral distortions and (ii) sampling a region of the suspect syringe/needle assembly where manufacturer-applied PDMS is not typically located. Analysis for blood indicated that the Teichman microchemical test was effective for detecting blood in the presence of PDMS. Overall, detecting PDMS established intent and detecting blood established that the needle containing the PDMS had been used for injection.


Asunto(s)
Sangre , Técnicas Cosméticas , Dimetilpolisiloxanos/aislamiento & purificación , Fraude , Agujas , Análisis Químico de la Sangre , Dimetilpolisiloxanos/química , Ciencias Forenses , Humanos , Indicadores y Reactivos , Microscopía , Espectroscopía Infrarroja por Transformada de Fourier
5.
Am J Trop Med Hyg ; 91(5): 920-924, 2014 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-25266348

RESUMEN

There is an urgent need for accurate and inexpensive handheld instruments for the evaluation of medicine quality in the field. A blinded evaluation of the diagnostic accuracy of the Counterfeit Detection Device 3 (CD-3), developed by the US Food and Drug Administration Forensic Chemistry Center, was conducted in the Lao People's Democratic Republic. Two hundred three samples of the oral antimalarial artesunate were compared with authentic products using the CD-3 by a trainer and two trainees. The specificity (95% confidence interval [95% CI]), sensitivity (95% CI), positive predictive value (95% CI), and negative predictive value (95% CI) of the CD-3 for detecting counterfeit (falsified) artesunate were 100% (93.8-100%), 98.4% (93.8-99.7%), 100% (96.2-100%), and 97.4% (90.2-99.6%), respectively. Interobserver agreement for 203 samples of artesunate was 100%. The CD-3 holds promise as a relatively inexpensive and easy to use instrument for field evaluation of medicines, potentially empowering drug inspectors, customs agents, and pharmacists.


Asunto(s)
Antimaláricos/análisis , Artemisininas/análisis , Medicamentos Falsificados/análisis , Fluorescencia , Imagen Óptica/instrumentación , Artesunato , Cromatografía Líquida de Alta Presión , Intervalos de Confianza , Laos , Malaria/tratamiento farmacológico , Imagen Óptica/métodos , Sensibilidad y Especificidad
6.
Anal Chem ; 83(15): 5972-8, 2011 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-21651233

RESUMEN

Advantages and limitations of analyzing authentic and counterfeit pharmaceutical tablets with both macro (nonimaging) attenuated total internal reflection Fourier transform infrared (ATR-FT-IR) spectroscopy and micro ATR-FT-IR spectroscopic imaging have been evaluated. The results of this study demonstrated that micro ATR imaging was more effective for extracting formulation information (sourcing), whereas a macro ATR approach was better suited for counterfeit detection (screening). More importantly, this study demonstrated that a thorough analysis of the counterfeit core can be achieved by combining the results of both techniques.


Asunto(s)
Medicamentos Falsificados/análisis , Espectroscopía Infrarroja por Transformada de Fourier/métodos , Comprimidos/química , Modelos Teóricos
7.
Appl Spectrosc ; 63(9): 979-91, 2009 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-19796479

RESUMEN

A planar array infrared (PA-IR) spectrograph containing an attenuated total internal reflection (ATR) accessory has been constructed in order to permit rapid analysis of poorly transmitting materials. The technique has been optimized to allow molecular spectroscopic information to be collected in roughly 2 seconds with a corresponding peak-to-peak noise value as low as 2.14 x 10(-4) absorbance units. Additionally, up to 150 spectra could be extracted from sample sizes as large as 6 mm where each spatial element measured 40 x 200 microm at the sample position. An application study for this technique entailed developing an embedding method that allows cross-sectioned pharmaceutical tablets to be brought into intimate contact with the internal reflection element (IRE) of the accessory. A supplemental investigation involved calculating the yield strength of multiple IRE materials in order to determine the maximum amount of pressure that can be applied to a sample without damaging the IRE. Finally, feasibility was demonstrated for using the instrument/accessory as a means to rapidly authenticate suspected counterfeit pharmaceutical tablets.


Asunto(s)
Contaminación de Medicamentos , Imagen Molecular/instrumentación , Imagen Molecular/métodos , Espectrofotometría Infrarroja/métodos , Espectroscopía Infrarroja por Transformada de Fourier/métodos , Antiinflamatorios no Esteroideos/análisis , Diseño de Equipo , Estudios de Factibilidad , Ensayo de Materiales/métodos , Naproxeno/análisis , Medicamentos sin Prescripción/análisis , Comprimidos/análisis , Factores de Tiempo
8.
Am J Vet Res ; 69(9): 1217-28, 2008 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-18764697

RESUMEN

OBJECTIVE: To determine whether renal crystals can be experimentally induced in animals fed melamine or the related triazine compound cyanuric acid, separately or in combination, and to compare experimentally induced crystals with those from a cat with triazine-related renal failure. ANIMALS: 75 fish (21 tilapia, 24 rainbow trout, 15 channel catfish, and 15 Atlantic salmon), 4 pigs, and 1 cat that was euthanatized because of renal failure. PROCEDURES: Fish and pigs were fed a target dosage of melamine (400 mg/kg), cyanuric acid (400 mg/kg), or melamine and cyanuric acid (400 mg of each compound/kg) daily for 3 days and were euthanatized 1, 3, 6, 10, or 14 days after administration ceased. Fresh, frozen, and formalin-fixed kidneys were examined for crystals. Edible tissues were collected for residue analysis. Crystals were examined for composition via Raman spectroscopy and hydrophilic-interaction liquid chromatography-tandem mass spectrometry. RESULTS: All animals fed the combination of melamine and cyanuric acid developed goldbrown renal crystals arranged in radial spheres (spherulites), similar to those detected in the cat. Spectral analyses of crystals from the cat, pigs, and fish were consistent with melamine-cyanurate complex crystals. Melamine and cyanuric acid residues were identified in edible tissues of fish. CONCLUSIONS AND CLINICAL RELEVANCE: Although melamine and cyanuric acid appeared to have low toxicity when administered separately, they induced extensive renal crystal formation when administered together. The subsequent renal failure may be similar to acute uric acid nephropathy in humans, in which crystal spherulites obstruct renal tubules.


Asunto(s)
Riñón/efectos de los fármacos , Triazinas/farmacología , Alimentación Animal/análisis , Animales , Gatos , Cristalización , Peces , Contaminación de Alimentos , Intestinos/efectos de los fármacos , Intestinos/patología , Riñón/patología , Masculino , Espectrometría Raman , Análisis de Supervivencia , Porcinos , Triazinas/química , Triazinas/toxicidad
9.
J Forensic Sci ; 51(2): 321-9, 2006 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-16566765

RESUMEN

In forensic evidence, gamma-hydroxybutyric acid (GHB) has frequently been encountered in one of its salt forms (gamma-hydroxybutyrate), but has also been encountered in its free acid form (GHB). Owing to the physical properties, encounters of the free acid have been largely restricted to forensic exhibits comprising aqueous solutions, such as acidic beverages that have been "spiked" or formulated with GHB salts or gamma-butyrolactone (GBL). The analysis of GHB free acid presents particular difficulties including the potential for altering the original proportions of GHB free acid, GHB carboxylate, and GBL in the course of analysis, and discrimination between GHB free acid and carboxylate forms. In this work, the formation of GHB free acid in aqueous solutions (water and/or D2O) was studied as a function of solution pH. Proton nuclear magnetic resonance (1HNMR) and Fourier-transform infrared spectrometry (FT-IR) measurements were obtained on freshly prepared mixtures of NaGHB and HCl stock solutions representing a series of points along the GHB titration curve. Both 1HNMR and FT-IR were shown to track the changing proportions of GHB free acid and carboxylate forms as a function of pH, while simultaneously monitoring for the formation of the lactone (GBL). The results were consistent with acid-base conversion behavior for a carboxylic acid. 1HNMR was shown to provide an ideal means for analysis of aqueous-based GHB/GBL forensic exhibits based on simple dilution of the neat liquid exhibit, without altering the original proportions of GHB free acid, carboxylate, and GBL in the samples.

10.
J Forensic Sci ; 51(2): 330-9, 2006 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-16566766

RESUMEN

A reference standard for gamma-hydroxybutyric acid (GHB) free acid is not commercially available, making its analysis in forensic exhibits more difficult. GHB free acid is typically encountered in aqueous solution and in the presence of the lactone, gamma-butyrolactone (GBL), presenting difficulty in Fourier transform infrared (FT-IR) analysis. The strong infrared (IR) absorptivity of the GBL carbonyl band, the shifting of the GBL carbonyl band in aqueous solutions, and the position of the O-H bend for water can mask the main carbonyl band for GHB free acid. Model solutions of beta-hydroxybutyric acid (BHB) and GBL were studied in order to further understand the masking of the GHB free acid carbonyl band in FT-IR analysis. The use of second derivative FT-IR spectroscopy was shown to provide resolution of the free acid carbonyl band, and a presumptive test for GHB free acid was developed and applied. An extension of this work included preparing, for use as a standard reference material, small amounts (< or = 10 mg) of GHB free acid. Preparation was based on the instantaneous reaction of GHB's sodium salt with a stoichiometric amount of hydrochloric acid in aqueous solution, and subsequent isolation of the free acid in neat liquid form. Both FT-IR and proton nuclear magnetic resonance spectra of the neat reference material were obtained and used to verify its identity. The isolation of GHB free acid from actual forensic exhibits is also presented, with identity confirmation using FT-IR.

11.
Chem Res Toxicol ; 18(12): 1821-9, 2005 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-16359172

RESUMEN

The reaction of dimethylarsinic acid (DMAV) with hydrogen sulfide (H2S) is of biological significance and may be implicated in the overall toxicity and carcinogenicity of arsenic. The course of the reaction in aqueous phase was monitored, and an initial product, dimethylthioarsinic acid, was observed by using LC-ICP-MS and LC-ESI-MS. Dimethylarsinous acid was observed as a minor product. A second slower-forming product was identified, and the electrospray mass chromatograms for this species produced ions at m/z 275, 171, and 137 in positive mode. To aid in the identification of this slower-forming product, crystalline standards of sodium dimethyldithioarsinate and dimethylarsino dimethyldithioarsinate were prepared and re-characterized by using improved spectroscopic and structural analysis techniques. An aqueous solution of sodium dimethyldithioarsinate produced a single major chromatographic peak that matched the retention time (7.6 min) of the slower-forming product and contained similar molecular ions at m/z 275, 171, and 137 via LC-ESI-MS. The dimethylarsino dimethyldithioarsinate standard produced four aqueous phase species one of which coeluted with the slower forming product. This coeluting peak also produced the identical ESI-MS ions as the slower-forming product of DMAV + H2S. ESI-MS/MS experiments conducted on sodium dimethyldithioarsinate in deuterated water produced molecular ions at m/z 276, 173, and 137. Subsequent collisionally activated dissociation (CAD) experiments on m/z 276 did not produce a product ion at m/z 173. These data indicate that two different species are present in solution, while NMR data indicate that only dimethyldithioarsinic acid exists in aqueous solutions. This discrepancy was investigated by conducting NMR studies on the acidic solution of sodium dimethyldithioarsinate after taking this solution to dryness. The resolubilized solution produced a proton NMR signal characteristic of dimethylarsino dimethyldithioarsinate. Therefore, it was concluded that the ESI-MS ion at m/z 275 associated with the slowly forming second reaction product and the sodium dimethyldithioarsinate compound is a product of the ESI desolvation process.


Asunto(s)
Ácido Cacodílico/química , Sulfuro de Hidrógeno/química , Cromatografía de Gases y Espectrometría de Masas , Modelos Moleculares , Espectrometría de Masa por Ionización de Electrospray
12.
J Forensic Sci ; 50(2): 326-35, 2005 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-15813543

RESUMEN

The recent emergence of a new class of piperazine-type compounds has brought about the need for laboratory screening methods for both seized drugs and toxicological samples. These piperazine compounds, which include 1-benzylpiperazine (BZP) and 1-(3-trifluoromethylphenyl)piperazine (TFMPP), exhibit comparable physiological effects and can be substituted for the classic amphetamine-type drugs. We have optimized a chiral capillary electrophoresis (CE) separation that detects a set of 6 piperazine and 4 chiral amphetamine compounds in under 23 min using a 200 mM phosphate buffer at a pH = 2.8 with 20 mM hydroxypropyl- beta-cyclodextrin (HPbeta3CD). In addition to the above compounds, a series of "clandestine" BZP diHCl samples were also analyzed using this method to assess the ruggedness of the procedure. The novel CE separation was tailored to simultaneously detect these piperzine compounds in addition to amphetamine-type drugs. Distinct migration time and UV-spectral data were obtained for all compounds of interest.


Asunto(s)
Anfetaminas/análisis , Antinematodos/análisis , Drogas de Diseño/análisis , Electroforesis Capilar/métodos , Piperazinas/análisis , Anfetaminas/aislamiento & purificación , Antinematodos/aislamiento & purificación , Drogas de Diseño/aislamiento & purificación , Humanos , Piperazina , Piperazinas/aislamiento & purificación , Sensibilidad y Especificidad , Estereoisomerismo , Trastornos Relacionados con Sustancias
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...