Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Heart ; 2024 Aug 09.
Artículo en Inglés | MEDLINE | ID: mdl-39122559

RESUMEN

BACKGROUND: Young patients suffering from cryptogenic stroke alongside a patent foramen ovale (PFO) are often considered for percutaneous device closure to reduce the risk of stroke recurrence. Residual right-to-left shunt after device closure may persist in approximately a quarter of the patients at 6 months, and some may close at a later time point. This study aimed to assess the prevalence and persistence of residual right-to-left shunt after percutaneous PFO closure. METHODS: Consecutive patients undergoing transoesophageal echocardiography-guided PFO closure for cryptogenic stroke between 2006 and 2021, with echocardiographic follow-up including contrast bubble study and Valsalva manoeuvre, were enrolled. Follow-up transthoracic echocardiography was performed at 6 months and repeated at 12 months in case of residual right-to-left shunt. Primary outcomes included the prevalence and grade of residual right-to-left shunt at 6 and 12 months after percutaneous PFO closure. RESULTS: 227 patients were included with a mean age of 43±11 years and 50.2% were women. At 6-month follow-up, 72.7% had no residual right-to-left shunt, 12.3% small residual right-to-left shunt, 6.6% moderate residual right-to-left shunt and 8.4% large residual right-to-left shunt. At 12-month follow-up, the presence of residual right-to-left shunt in all patients was 12.3%, of whom 6.6% had small residual right-to-left shunt, 2.6% had moderate residual right-to-left shunt and 3.1% had large residual right-to-left shunt. CONCLUSIONS: Residual right-to-left shunts are common at 6 months after percutaneous closure of PFO. However, the majority are small and two-thirds of residual right-to-left shunts achieve complete closure between 6 and 12 months.

2.
J Clin Med ; 12(14)2023 Jul 20.
Artículo en Inglés | MEDLINE | ID: mdl-37510913

RESUMEN

INTRODUCTION: Increasing survival of adult congenital heart disease (ACHD) patients comes at the price of a range of late complications-arrhythmias, heart failure, and valvular dysfunction. Transcatheter valve interventions have become a legitimate alternative to conventional surgical treatment in selected acquired heart disease patients. However, literature on technical aspects, hemodynamic effects, and clinical outcomes of percutaneous atrioventricular (AV) valve interventions in ACHD patients is scarce. METHOD: This is a descriptive cohort from CAHAL (Center of Congenital Heart Disease Amsterdam-Leiden). ACHD patients with severe AV valve regurgitation who underwent a transcatheter intervention in the period 2020-2022 were included. Demographic, clinical, procedural, and follow-up data were collected from patient records. RESULTS: Five ACHD patients with severe or torrential AV valve regurgitation are described. Two patients underwent a transcatheter edge-to-edge repair (TEER), one patient underwent a valve-in-valve procedure, one patient received a Cardioband system, and one patient received both a Cardioband system and TEER. No periprocedural complications occurred. Post-procedural AV valve regurgitation as well as NYHA functional class improved in all patients. The median post-procedural NYHA functional class improved from 3.0 (IQR [2.5-4.0]) to 2.0 (IQR [1.5-2.5]). One patient died 9 months after the procedure due to advanced heart failure with multiorgan dysfunction. CONCLUSION: Transcatheter valve repair is feasible and safe in selected complex ACHD patients. A dedicated heart team is essential for determining an individualized treatment strategy as well as pre- and periprocedural imaging to address the underlying mechanism(s) of AV regurgitation and guide the transcatheter intervention. Long-term follow-up is essential to evaluate the clinical outcomes of transcatheter AV valve repair in ACHD patients.

3.
Catheter Cardiovasc Interv ; 102(2): 273-280, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37221985

RESUMEN

BACKGROUND: NobleStitch EL is a novel suture-based technique used for patent foramen ovale (PFO) closure and an alternative to traditional double-disc devices without the need for antithrombotic therapy. However, successful closure rates are still unknown, and certain anatomies may be unfavorable for successful closure. AIMS: We assessed the efficacy of the NobleStitch EL and sought to identify patient-related anatomical features associated with successful suture-based closure. METHODS: We included 55 patients who underwent PFO closure with the NobleStitch EL in The Netherlands and Switzerland. Successful closure was defined as residual right-to-left shunt grade ≤1 with Valsalva maneuver at a cardiac ultrasound. Predefined possible anatomical determinants for effective closure included PFO length, atrial septal aneurysm, PFO entry- and exit diameter. RESULTS: Successful closure was achieved in 33 patients (60%). The PFO length was shorter in patients with successful closure compared to unsuccessful closure with a median length of 9.6 mm (IQR 8.0-15.0) versus 13.3 mm (IQR 11.4-18.6) on preprocedural ultrasound (p = 0.041) and 9.9 mm (IQR 8.0-13.1) versus 12.5 mm (IQR 9.7-15.4) on angiography (p = 0.049). Additionally, the PFO exit diameter and PFO volume were smaller in patients with successful closure than unsuccessful closure, with a mean diameter of 7.0 ± 3.1 mm versus 9.5 ± 3.8 mm (p = 0.015) and a median volume of 381 mm3 (IQR 286-894) versus 985 mm3 (IQR 572-1550) (p = 0.016). CONCLUSION: In our study cohort, the successful PFO closure rate using NobleStitch EL was relatively low (60%). With this alternative procedure, patients with a small PFO driven by a short PFO tunnel length and small exit diameter seem to be eligible for successful suture-based closure.


Asunto(s)
Foramen Oval Permeable , Accidente Cerebrovascular , Humanos , Foramen Oval Permeable/diagnóstico por imagen , Foramen Oval Permeable/terapia , Foramen Oval Permeable/complicaciones , Resultado del Tratamiento , Ecocardiografía Transesofágica , Cateterismo Cardíaco , Suturas
5.
JACC Case Rep ; 3(14): 1589-1593, 2021 Oct 20.
Artículo en Inglés | MEDLINE | ID: mdl-34729507

RESUMEN

This report describes the case of a symptomatic patient with a right coronary artery fistula draining into the coronary sinus who underwent transcatheter closure, which was deployed in the drainage site to seal off the exit of the fistula. (Level of Difficulty: Advanced.).

6.
J Imaging ; 6(9)2020 Aug 24.
Artículo en Inglés | MEDLINE | ID: mdl-34460741

RESUMEN

We present a numerical illumination model to calculate direct as well as diffuse or Hapke scattered radiation scenarios on arbitrary planetary surfaces. This includes small body surfaces such as main belt asteroids as well as e.g., the lunar surface. The model is based on the ray tracing method. This method is not restricted to spherical or ellipsoidal shapes but digital terrain data of arbitrary spatial resolution can be fed into the model. Solar radiation is the source of direct radiation, wavelength-dependent effects (e.g. albedo) can be accounted for. Mutual illumination of individual bodies in implemented (e.g. in binary or multiple systems) as well as self-illumination (e.g. crater floors by crater walls) by diffuse or Hapke radiation. The model is validated by statistical methods. A χ2 test is utilized to compare simulated images with DAWN images acquired during the survey phase at small body 4 Vesta and to successfully prove its validity.

7.
Science ; 349(6247): aaa9816, 2015 Jul 31.
Artículo en Inglés | MEDLINE | ID: mdl-26228158

RESUMEN

The Philae lander, part of the Rosetta mission to investigate comet 67P/Churyumov-Gerasimenko, was delivered to the cometary surface in November 2014. Here we report the precise circumstances of the multiple landings of Philae, including the bouncing trajectory and rebound parameters, based on engineering data in conjunction with operational instrument data. These data also provide information on the mechanical properties (strength and layering) of the comet surface. The first touchdown site, Agilkia, appears to have a granular soft surface (with a compressive strength of 1 kilopascal) at least ~20 cm thick, possibly on top of a more rigid layer. The final landing site, Abydos, has a hard surface.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA