Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 215
Filtrar
1.
AACN Adv Crit Care ; 35(2): 146-156, 2024 Jun 15.
Artículo en Inglés | MEDLINE | ID: mdl-38848565

RESUMEN

Serious illness communication can be especially distressing for patients who are critically ill and their loved ones who experience forms of discrimination based on identities such as their race, gender, sexual orientation, and other intersecting identities. In this article, we discuss the concept of intersectionality and its association with serious illness communication, decision-making, and care in the intensive care unit. Additionally, we present relevant concepts from clinical practice and contemporary nursing and health care literature to support critical care nurses in fostering more inclusive serious illness communication in the intensive care unit.


Asunto(s)
Enfermería de Cuidados Críticos , Enfermedad Crítica , Unidades de Cuidados Intensivos , Humanos , Masculino , Femenino , Enfermedad Crítica/enfermería , Enfermería de Cuidados Críticos/normas , Persona de Mediana Edad , Adulto , Comunicación , Anciano , Relaciones Enfermero-Paciente , Anciano de 80 o más Años , Estados Unidos
2.
Pediatr Blood Cancer ; : e31117, 2024 May 28.
Artículo en Inglés | MEDLINE | ID: mdl-38804882

RESUMEN

BACKGROUND: Aromatase inhibitors (AI) may improve height in short stature conditions; however, the effect in childhood cancer survivors (CCS) is unknown. We assessed final adult height (FAH) in CCS treated with AI and GH compared with those treated with GH alone. METHODS: Retrospective cohort study of GH-deficient male CCS treated between 2007 and 2023. FAH was noted as the height at the fusion of growth plates or 18 years of age. Multivariable linear regression was used to examine treatment association with FAH, adjusting for other risk factors. RESULTS: Ninety-two patients were included; 70 were treated with GH and 22 with combination AI/GH. The mean age at GH initiation did not differ between groups. The mean age at AI initiation was 13.7 ± 1.9 years. A greater proportion of patients in the AI/GH group were treated with stem cell transplantation, abdominal radiation, total body irradiation, and cis-retinoic acid (p < .01). Multivariable linear regression demonstrated no significant treatment association with FAH Z-score (ß = 0.04, 95% CI: -0.9 to 0.9). History of spinal radiation (ß = -0.93, 95% CI: -1.7 to -0.2), lower starting height Z-score (ß = -0.8, 95% CI: -1.2 to -0.4), and greater difference between bone age and chronological age (ß = -0.3, 95% CI: -0.5 to -0.07) were associated with lower FAH Z-score. CONCLUSIONS: Adjuvant AI was not associated with increased FAH in male CCS compared with GH monotherapy. Future work is needed to determine the optimal adjunctive treatment to maximize FAH for this population.

3.
Front Immunol ; 15: 1386586, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38779663

RESUMEN

Background: Sepsis, a life-threatening condition caused by the dysregulated host response to infection, is a major global health concern. Understanding the impact of viral or bacterial pathogens in sepsis is crucial for improving patient outcomes. This study aimed to investigate the human cytomegalovirus (HCMV) seropositivity as a risk factor for development of sepsis in patients with COVID-19. Methods: A multicenter observational study enrolled 95 intensive care patients with COVID-19-induced sepsis and 80 post-surgery individuals as controls. HCMV serostatus was determined using an ELISA test. Comprehensive clinical data, including demographics, comorbidities, and 30-day mortality, were collected. Statistical analyses evaluated the association between HCMV seropositivity and COVID-19 induced sepsis. Results: The prevalence of HCMV seropositivity did not significantly differ between COVID-19-induced sepsis patients (78%) and controls (71%, p = 0.382) in the entire cohort. However, among patients aged ≤60 years, HCMV seropositivity was significantly higher in COVID-19 sepsis patients compared to controls (86% vs 61%, respectively; p = 0.030). Nevertheless, HCMV serostatus did not affect 30-day survival. Discussion: These findings confirm the association between HCMV seropositivity and COVID-19 sepsis in non-geriatric patients. However, the lack of an independent effect on 30-day survival can be explained by the cross-reactivity of HCMV specific CD8+ T-cells towards SARS-CoV-2 peptides, which might confer some protection to HCMV seropositive patients. The inclusion of a post-surgery control group strengthens the generalizability of the findings. Further research is needed to elucidate the underlying mechanisms of this association, explore different patient populations, and identify interventions for optimizing patient management. Conclusion: This study validates the association between HCMV seropositivity and severe COVID-19-induced sepsis in non-geriatric patients, contributing to the growing body of evidence on viral pathogens in sepsis. Although HCMV serostatus did not independently influence 30-day survival, future investigations should focus on unraveling the intricate interplay between HCMV, immune responses, and COVID-19. These insights will aid in risk stratification and the development of targeted interventions for viral sepsis.


Asunto(s)
COVID-19 , Infecciones por Citomegalovirus , Citomegalovirus , SARS-CoV-2 , Sepsis , Humanos , COVID-19/inmunología , COVID-19/mortalidad , COVID-19/epidemiología , COVID-19/complicaciones , Masculino , Femenino , Persona de Mediana Edad , Sepsis/inmunología , Sepsis/epidemiología , Sepsis/mortalidad , Citomegalovirus/inmunología , Anciano , Infecciones por Citomegalovirus/inmunología , Infecciones por Citomegalovirus/epidemiología , Infecciones por Citomegalovirus/mortalidad , Infecciones por Citomegalovirus/complicaciones , SARS-CoV-2/inmunología , Factores de Riesgo , Adulto , Anticuerpos Antivirales/sangre
4.
PLoS One ; 19(3): e0300739, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38547245

RESUMEN

INTRODUCTION: An increasing amount of longitudinal health data is available on critically ill septic patients in the age of digital medicine, including daily sequential organ failure assessment (SOFA) score measurements. Thus, the assessment in sepsis focuses increasingly on the evaluation of the individual disease's trajectory. Machine learning (ML) algorithms may provide a promising approach here to improve the evaluation of daily SOFA score dynamics. We tested whether ML algorithms can outperform the conventional ΔSOFA score regarding the accuracy of 30-day mortality prediction. METHODS: We used the multicentric SepsisDataNet.NRW study cohort that prospectively enrolled 252 sepsis patients between 03/2018 and 09/2019 for training ML algorithms, i.e. support vector machine (SVM) with polynomial kernel and artificial neural network (aNN). We used the Amsterdam UMC database covering 1,790 sepsis patients for external and independent validation. RESULTS: Both SVM (AUC 0.84; 95% CI: 0.71-0.96) and aNN (AUC 0.82; 95% CI: 0.69-0.95) assessing the SOFA scores of the first seven days led to a more accurate prognosis of 30-day mortality compared to the ΔSOFA score between day 1 and 7 (AUC 0.73; 95% CI: 0.65-0.80; p = 0.02 and p = 0.05, respectively). These differences were even more prominent the shorter the time interval considered. Using the SOFA scores of day 1 to 3 SVM (AUC 0.82; 95% CI: 0.68 0.95) and aNN (AUC 0.80; 95% CI: 0.660.93) led to a more accurate prognosis of 30-day mortality compared to the ΔSOFA score (AUC 0.66; 95% CI: 0.58-0.74; p < 0.01 and p < 0.01, respectively). Strikingly, all these findings could be confirmed in the independent external validation cohort. CONCLUSIONS: The ML-based algorithms using daily SOFA scores markedly improved the accuracy of mortality compared to the conventional ΔSOFA score. Therefore, this approach could provide a promising and automated approach to assess the individual disease trajectory in sepsis. These findings reflect the potential of incorporating ML algorithms as robust and generalizable support tools on intensive care units.


Asunto(s)
Puntuaciones en la Disfunción de Órganos , Sepsis , Humanos , Estudios Retrospectivos , Unidades de Cuidados Intensivos , Aprendizaje Automático , Sepsis/diagnóstico , Pronóstico , Curva ROC
5.
EuroIntervention ; 20(6): e363-e375, 2024 03 18.
Artículo en Inglés | MEDLINE | ID: mdl-38506737

RESUMEN

BACKGROUND: There is a lack of comparative data on transcatheter aortic valve implantation (TAVI) in degenerated surgical prostheses (valve-in-valve [ViV]). AIMS: We sought to compare outcomes of using two self-expanding transcatheter heart valve (THV) systems for ViV. METHODS: In this retrospective multicentre registry, we included consecutive patients undergoing transfemoral ViV using either the ACURATE neo/neo2 (ACURATE group) or the Evolut R/PRO/PRO+ (EVOLUT group). The primary outcome measure was technical success according to Valve Academic Research Consortium (VARC)-3. Secondary outcomes were 30-day all-cause mortality, device success (VARC-3), coronary obstruction (CO) requiring intervention, rates of severe prosthesis-patient mismatch (PPM), and aortic regurgitation (AR) ≥moderate. Comparisons were made after 1:1 propensity score matching. RESULTS: The study cohort comprised 835 patients from 20 centres (ACURATE n=251; EVOLUT n=584). In the matched cohort (n=468), technical success (ACURATE 92.7% vs EVOLUT 88.9%; p=0.20) and device success (69.7% vs 73.9%; p=0.36) as well as 30-day mortality (2.8% vs 1.6%; p=0.392) were similar between the two groups. The mean gradients and rates of severe PPM, AR ≥moderate, or CO did not differ between the groups. Technical and device success were higher for the ACURATE platform among patients with a true inner diameter (ID) >19 mm, whereas a true ID ≤19 mm was associated with higher device success - but not technical success - among Evolut recipients. CONCLUSIONS: ViV TAVI using either ACURATE or Evolut THVs showed similar procedural outcomes. However, a true ID >19 mm was associated with higher device success among ACURATE recipients, whereas in patients with a true ID ≤19 mm, device success was higher when using Evolut.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Bioprótesis , Oclusión Coronaria , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Catéteres , Insuficiencia de la Válvula Aórtica/etiología , Insuficiencia de la Válvula Aórtica/cirugía , Válvulas Cardíacas , Sistema de Registros , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos
6.
PLoS One ; 19(2): e0299320, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38422105

RESUMEN

This will be the first meta-analysis on the efficacy, safety, and side effects of oliceridine on postoperative pain. Our aim with this work is to evaluate the clinical utility of this relatively new substance in a broad postoperative context. Oliceridine is a new so-called bias opioid that is approved for severe pain requiring an opioid. Due to its biased agonism, it is said to have fewer side effects than conventional opioids. This systematic review and meta-analysis will analyze the efficacy, safety, and side effects of oliceridine compared to placebo or morphine in acute postoperative pain for up to 72 hours. In January 2024, an extensive search in various databases will be performed without restrictions for randomized controlled trials with at least single blinding. After data extraction, data will be pooled and meta-analytic calculations performed. A random-effects model will be used. Dichotomous data will be presented as risk ratio and continuous data as standardized mean difference. Dose-dependent side effects will be evaluated with meta-regression. Heterogeneity will be assessed via the Q statistic and prediction interval in case of a sufficient number of included studies. Publication bias will be examined using funnel plot and Duval and Tweedie's trim and fill method.


Asunto(s)
Analgésicos Opioides , Dolor Postoperatorio , Compuestos de Espiro , Tiofenos , Humanos , Analgésicos Opioides/efectos adversos , Analgésicos Opioides/uso terapéutico , Metaanálisis como Asunto , Dolor Postoperatorio/tratamiento farmacológico , Compuestos de Espiro/efectos adversos , Compuestos de Espiro/uso terapéutico , Revisiones Sistemáticas como Asunto , Tiofenos/efectos adversos , Tiofenos/uso terapéutico
7.
Int J Mol Sci ; 25(3)2024 Jan 23.
Artículo en Inglés | MEDLINE | ID: mdl-38338680

RESUMEN

Sepsis is a common life-threatening disease caused by dysregulated immune response and metabolic acidosis which lead to organ failure. An abnormal expression of aquaporins plays an important role in organ failure. Additionally, genetic variants in aquaporins impact on the outcome in sepsis. Thus, we investigated the polymorphism (rs17553719) and expression of aquaporin-3 (AQP3) and correlated these measurements with the survival of sepsis patients. Accordingly, we collected blood samples on several days (plus clinical data) from 265 sepsis patients who stayed in different ICUs in Germany. Serum plasma, DNA, and RNA were then separated to detect the promotor genotypes of AQP3 mRNA expression of AQP3 and several cytokines. The results showed that the homozygote CC genotype exhibited a significant decrease in 30-day survival (38.9%) compared to the CT (66.15%) and TT genotypes (76.3%) (p = 0.003). Moreover, AQP3 mRNA expression was significantly higher and nearly doubled in the CC compared to the CT (p = 0.0044) and TT genotypes (p = 0.018) on the day of study inclusion. This was accompanied by an increased IL-33 concentration in the CC genotype (day 0: p = 0.0026 and day 3: p = 0.008). In summary, the C allele of the AQP3 polymorphism (rs17553719) shows an association with increased AQP3 expression and IL-33 concentration accompanied by decreased survival in patients with sepsis.


Asunto(s)
Acuaporinas , Sepsis , Humanos , Acuaporina 3/genética , Acuaporinas/genética , Acuaporinas/metabolismo , Genotipo , Interleucina-33/genética , Interleucina-33/metabolismo , ARN Mensajero/metabolismo , Sepsis/genética , Sepsis/metabolismo
8.
JACC Cardiovasc Interv ; 17(3): 374-387, 2024 Feb 12.
Artículo en Inglés | MEDLINE | ID: mdl-38180419

RESUMEN

BACKGROUND: The COVID-19 pandemic adversely affected health care systems. Patients in need of transcatheter aortic valve replacement (TAVR) are especially susceptible to treatment delays. OBJECTIVES: This study sought to evaluate the impact of the COVID-19 pandemic on global TAVR activity. METHODS: This international registry reported monthly TAVR case volume in participating institutions prior to and during the COVID-19 pandemic (January 2018 to December 2021). Hospital-level information on public vs private, urban vs rural, and TAVR volume was collected, as was country-level information on socioeconomic status, COVID-19 incidence, and governmental public health responses. RESULTS: We included 130 centers from 61 countries, including 65,980 TAVR procedures. The first and second pandemic waves were associated with a significant reduction of 15% (P < 0.001) and 7% (P < 0.001) in monthly TAVR case volume, respectively, compared with the prepandemic period. The third pandemic wave was not associated with reduced TAVR activity. A greater reduction in TAVR activity was observed in Africa (-52%; P = 0.001), Central-South America (-33%; P < 0.001), and Asia (-29%; P < 0.001). Private hospitals (P = 0.005), urban areas (P = 0.011), low-volume centers (P = 0.002), countries with lower development (P < 0.001) and economic status (P < 0.001), higher COVID-19 incidence (P < 0.001), and more stringent public health restrictions (P < 0.001) experienced a greater reduction in TAVR activity. CONCLUSIONS: TAVR procedural volume declined substantially during the first and second waves of the COVID-19 pandemic, especially in Africa, Central-South America, and Asia. National socioeconomic status, COVID-19 incidence, and public health responses were associated with treatment delays. This information should inform public health policy in case of future global health crises.


Asunto(s)
Estenosis de la Válvula Aórtica , COVID-19 , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Pandemias , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/epidemiología , Resultado del Tratamiento , COVID-19/epidemiología , Sistema de Registros , Factores de Riesgo
9.
Int J Cardiol ; 400: 131792, 2024 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-38244892

RESUMEN

BACKGROUND: ACURATE neo2 (Neo2) implantation is performed after systematic Balloon Aortic Valvuloplasty (BAV) in most patients. No reports exist about the feasibility and safety of direct Neo2 transcatheter aortic valve implantation (TAVI) in comparison to the standard practice. AIM: We aimed to identify the patients' baseline anatomical characteristics, procedural, and early post-procedural outcomes in patients treated using Neo2 with and without BAV. METHODOLOGY: This is a retrospective multicentre analysis of 499 patients with severe aortic stenosis who underwent TAVI using Neo2. The comparison was done according to the performance or omission of BAV. Echocardiography and computed tomography were analysed by an independent Core Lab. Propensity score matching (PSM) was performed based on the annular diameter and AV calcium volume, which identified 84 matched pairs. RESULTS: Among the cohort included, 391 (78%) patients received BAV (BAV-yes) and 108 (22%) were not attempted (BAV-no or Direct TAVI). Patients in BAV-no cohort had smaller annular diameter (22.6 vs 23.4 mm; p < 0.001) and lower calcium volume (163 vs 581 mm3; p < 0.001) compared to BAV-yes cohort. In the matched cohort, VARC-3 device technical success was similar (95%) and all other outcome measures were statistically comparable between cohorts. CONCLUSION: Direct TAVI using ACURATEneo2 without pre-TAVI balloon aortic valvuloplasty in patients with mild or less valve calcifications might be feasible and associated with comparable early outcomes compared to patients with similar anatomical features undergoing systematic balloon valvuloplasty.


Asunto(s)
Estenosis de la Válvula Aórtica , Valvuloplastia con Balón , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Valvuloplastia con Balón/métodos , Calcio , Resultado del Tratamiento , Estudios Retrospectivos , Diseño de Prótesis
10.
Int J Mol Sci ; 25(2)2024 Jan 19.
Artículo en Inglés | MEDLINE | ID: mdl-38279209

RESUMEN

Sepsis involves an immunological systemic response to a microbial pathogenic insult, leading to a cascade of interconnected biochemical, cellular, and organ-organ interaction networks. Potential drug targets can depict aquaporins, as they are involved in immunological processes. In immune cells, AQP3 and AQP9 are of special interest. In this study, we tested the hypothesis that these aquaporins are expressed in the blood cells of septic patients and impact sepsis survival. Clinical data, routine laboratory parameters, and blood samples from septic patients were analyzed on day 1 and day 8 after sepsis diagnosis. AQP expression and cytokine serum concentrations were measured. AQP3 mRNA expression increased over the duration of sepsis and was correlated with lymphocyte count. High AQP3 expression was associated with increased survival. In contrast, AQP9 expression was not altered during sepsis and was correlated with neutrophil count, and low levels of AQP9 were associated with increased survival. Furthermore, AQP9 expression was an independent risk factor for sepsis lethality. In conclusion, AQP3 and AQP9 may play contrary roles in the pathophysiology of sepsis, and these results suggest that AQP9 may be a novel drug target in sepsis and, concurrently, a valuable biomarker of the disease.


Asunto(s)
Acuaporinas , Sepsis , Humanos , Acuaporina 3/genética , Acuaporina 3/metabolismo , Acuaporinas/genética , Acuaporinas/metabolismo , Sepsis/genética
11.
Int J Mol Sci ; 25(1)2024 Jan 03.
Artículo en Inglés | MEDLINE | ID: mdl-38203778

RESUMEN

Sepsis is a life-threatening condition caused by the dysregulated host response to infection. Novel therapeutic options are urgently needed and aquaporin inhibitors could suffice as aquaporin 5 (Aqp5) knockdown provided enhanced sepsis survival in a murine sepsis model. Potential AQP5 inhibitors provide sulfonamides and their derivatives. In this study, we tested the hypothesis that sulfonamides reduce AQP5 expression in different conditions. The impact of sulfonamides on AQP5 expression and immune cell migration was examined in cell lines REH and RAW 264.7 by qPCR, Western blot and migration assay. Subsequently, whether furosemide and methazolamide are capable of reducing AQP5 expression after LPS incubation was investigated in whole blood samples of healthy volunteers. Incubation with methazolamide (10-5 M) and furosemide (10-6 M) reduced AQP5 mRNA and protein expression by about 30% in REH cells. Pre-incubation of the cells with methazolamide reduced cell migration towards SDF1-α compared to non-preincubated cells to control level. Pre-incubation with methazolamide in PBMCs led to a reduction in LPS-induced AQP5 expression compared to control levels, while furosemide failed to reduce it. Methazolamide appears to reduce AQP5 expression and migration of immune cells. However, after LPS administration, the reduction in AQP5 expression by methazolamide is no longer possible. Hence, our study indicates that methazolamide is capable of reducing AQP5 expression and has the potential to be used in sepsis prophylaxis.


Asunto(s)
Metazolamida , Sepsis , Humanos , Animales , Ratones , Furosemida , Lipopolisacáridos , Sulfonamidas , Movimiento Celular , Sulfanilamida , Sepsis/tratamiento farmacológico , ARN Mensajero/genética , Acuaporina 5/genética
12.
Clin Res Cardiol ; 113(1): 38-47, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37115228

RESUMEN

BACKGROUND: New-generation self-expanding transcatheter aortic heart valves (THV) were designed to overcome technical constraints of their preceding generations. We sought to compare the efficacy and safety of the self-expanding ACURATE neo2 (Neo2) versus Evolut PRO (PRO) devices. METHODS: Seven hundred nine patients undergoing transfemoral transcatheter aortic valve implantation (TAVI) with either Neo2 (n = 496) or PRO (n = 213) were included. Propensity score matching (PSM) was performed to account for differences in baseline characteristics. In-hospital and 30-day clinical outcomes were evaluated according to Valve Academic Research Consortium-3 criteria. RESULTS: Baseline characteristics were comparable between both groups after PSM (Neo2: n = 155, Evolut Pro: n = 155). Technical success rates were high in both groups (Neo2: 94.8% vs PRO: 97.4%; p = 0.239). Need for permanent pacemaker implantation was less frequent with Neo2 compared with PRO (7.5% vs 20.6%; p = 0.002), whereas major vascular complications were more frequent with Neo2 (Neo2: 11.6% vs PRO: 4.5%; p = 0.022). Intended valve performance at discharge was high in both groups without relevant differences among groups (Neo2: 97.4% vs. 95.3%; p = 0.328). CONCLUSIONS: Short-term outcomes after TAVI using latest-generation self-expanding THV were excellent, with overall low rates of adverse events. However, Neo2 was associated with lower pacemaker rates and reduced the prevalence of moderate-severe paravalvular leakage. Transprosthetic gradients after TAVI were higher with Neo2 compared with PRO.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Diseño de Prótesis , Resultado del Tratamiento
13.
J Neuroeng Rehabil ; 20(1): 111, 2023 08 21.
Artículo en Inglés | MEDLINE | ID: mdl-37605197

RESUMEN

Understanding of the human body's internal processes to maintain balance is fundamental to simulate postural control behaviour. The body uses multiple sensory systems' information to obtain a reliable estimate about the current body state. This information is used to control the reactive behaviour to maintain balance. To predict a certain motion behaviour with knowledge of the muscle forces, forward dynamic simulations of biomechanical human models can be utilized. We aim to use predictive postural control simulations to give therapy recommendations to patients suffering from postural disorders in the future. It is important to know which types of modelling approaches already exist to apply such predictive forward dynamic simulations. Current literature provides different models that aim to simulate human postural control. We conducted a systematic literature research to identify the different approaches of postural control models. The different approaches are discussed regarding their applied biomechanical models, sensory representation, sensory integration, and control methods in standing and gait simulations. We searched on Scopus, Web of Science and PubMed using a search string, scanned 1253 records, and found 102 studies to be eligible for inclusion. The included studies use different ways for sensory representation and integration, although underlying neural processes still remain unclear. We found that for postural control optimal control methods like linear quadratic regulators and model predictive control methods are used less, when models' level of details is increasing, and nonlinearities become more important. Considering musculoskeletal models, reflex-based and PD controllers are mainly applied and show promising results, as they aim to create human-like motion behaviour considering physiological processes.


Asunto(s)
Marcha , Equilibrio Postural , Humanos , Movimiento (Física) , Músculos , Reflejo
14.
JACC Cardiovasc Interv ; 16(16): 2004-2017, 2023 08 28.
Artículo en Inglés | MEDLINE | ID: mdl-37480891

RESUMEN

OBJECTIVES: The authors sought to evaluate the incidence, predictors, and outcomes of new permanent pacemaker implantation (PPI) after transcatheter aortic valve replacement (TAVR) with contemporary self-expanding valves (SEV). BACKGROUND: Need for PPI is frequent post-TAVR, but conflicting data exist on new-generation SEV and on the prognostic impact of PPI. METHODS: This study included 3,211 patients enrolled in the multicenter NEOPRO (A Multicenter Comparison of Acurate NEO Versus Evolut PRO Transcatheter Heart Valves) and NEOPRO-2 (A Multicenter Comparison of ACURATE NEO2 Versus Evolut PRO/PRO+ Transcatheter Heart Valves 2) registries (January 2012 to December 2021) who underwent transfemoral TAVR with SEV. Implanted transcatheter heart valves (THV) were Acurate neo (n = 1,090), Acurate neo2 (n = 665), Evolut PRO (n = 1,312), and Evolut PRO+ (n = 144). Incidence and predictors of new PPI and 1-year outcomes were evaluated. RESULTS: New PPI was needed in 362 patients (11.3%) within 30 days after TAVR (8.8%, 7.7%, 15.2%, and 10.4%, respectively, after Acurate neo, Acurate neo2, Evolut PRO, and Evolut PRO+). Independent predictors of new PPI were Society of Thoracic Surgeons Predicted Risk of Mortality score, baseline right bundle branch block and depth of THV implantation, both in patients treated with Acurate neo/neo2 and in those treated with Evolut PRO/PRO+. Predischarge reduction in ejection fraction (EF) was more frequent in patients requiring PPI (P = 0.014). New PPI was associated with higher 1-year mortality (16.9% vs 10.8%; adjusted HR: 1.66; 95% CI: 1.13-2.43; P = 0.010), particularly in patients with baseline EF <40% (P for interaction = 0.049). CONCLUSIONS: New PPI was frequently needed after TAVR with SEV (11.3%) and was associated with higher 1-year mortality, particularly in patients with EF <40%. Baseline right bundle branch block and depth of THV implantation independently predicted the need of PPI.


Asunto(s)
Marcapaso Artificial , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Incidencia , Bloqueo de Rama , Pronóstico , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
15.
Antibiotics (Basel) ; 12(7)2023 Jun 28.
Artículo en Inglés | MEDLINE | ID: mdl-37508212

RESUMEN

Bacteria of the genus Streptomyces produce various specialized metabolites. Single biosynthetic gene clusters (BGCs) can give rise to different products that can vary in terms of their biological activities. For example, for alnumycin and the shunt product K115, antimicrobial activity was described, while no antimicrobial activity was detected for the shunt product 1,6-dihydro 8-propylanthraquinone. To investigate the antibacterial activity of 1,6-dihydro 8-propylanthraquinone, we produced alnumycin and 1,6-dihydro 8-propylanthraquinone from a Streptomyces isolate containing the alnumycin BGC. The strain was cultivated in liquid glycerol-nitrate-casein medium (GN), and both compounds were isolated using an activity and mass spectrometry-guided purification. The structures were validated via nuclear magnetic resonance (NMR) spectroscopy. A minimal inhibitory concentration (MIC) test revealed that 1,6-dihydro 8-propylanthraquinone exhibits antimicrobial activity against E. coli ΔtolC, B. subtilis, an S. aureus type strain, and a vancomycin intermediate-resistance S. aureus strain (VISA). Activity of 1,6-dihydro 8-propylanthraquinone against E. coli ΔtolC was approximately 10-fold higher than that of alnumycin. We were unable to confirm gyrase inhibition for either compound and believe that the modes of action of both compounds are worth reinvestigating.

16.
Sensors (Basel) ; 23(12)2023 Jun 08.
Artículo en Inglés | MEDLINE | ID: mdl-37420590

RESUMEN

Biomechanical simulation allows for in silico estimations of biomechanical parameters such as muscle, joint and ligament forces. Experimental kinematic measurements are a prerequisite for musculoskeletal simulations using the inverse kinematics approach. Marker-based optical motion capture systems are frequently used to collect this motion data. As an alternative, IMU-based motion capture systems can be used. These systems allow flexible motion collection without nearly any restriction regarding the environment. However, one limitation with these systems is that there is no universal way to transfer IMU data from arbitrary full-body IMU measurement systems into musculoskeletal simulation software such as OpenSim. Thus, the objective of this study was to enable the transfer of collected motion data, stored as a BVH file, to OpenSim 4.4 to visualize and analyse the motion using musculoskeletal models. By using the concept of virtual markers, the motion saved in the BVH file is transferred to a musculoskeletal model. An experimental study with three participants was conducted to verify our method's performance. Results show that the present method is capable of (1) transferring body dimensions saved in the BVH file to a generic musculoskeletal model and (2) correctly transferring the motion data saved in the BVH file to a musculoskeletal model in OpenSim 4.4.


Asunto(s)
Sistema Musculoesquelético , Programas Informáticos , Humanos , Simulación por Computador , Movimiento (Física) , Fenómenos Biomecánicos
17.
J Am Heart Assoc ; 12(15): e029464, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37489732

RESUMEN

Background ACURATE neo2 is a transcatheter aortic valve implantation system consisting of a self-expanding bioprosthetic valve with supra-annular leaflet position and featuring innovations to facilitate placement accuracy and reduce paravalvular regurgitation. Methods and Results The goal of the Early neo2 (Early neo2 Registry of the ACURATE neo2 TAVI Prosthesis) was to gather real-life data on safety and efficacy in a European transcatheter aortic valve implantation population treated with ACURATE neo2. Data were collected from 554 consecutive patients treated with ACURATE neo2 at 12 European sites (mean age, 82 years; 66% women; mean European System for Cardiac Operative Risk Evaluation II, 4.5%±3.8%) between September 2020 and March 2021. The composite primary end point was the occurrence of any of the following: postoperative (in-hospital) paravalvular regurgitation grade ≥2, in-hospital acute kidney injury stage 3, postoperative pacemaker implantation, 30-day death, and 30-day stroke. The primary end point occurred in 12.6% of patients. The 30-day rates for all-cause death and all stroke were 1.3% and 2.7%, respectively, and 1.5% of patients exhibited stage 3 acute kidney injury. A total of 34 patients (6.2%) received a postoperative permanent pacemaker. Per core laboratory-adjudicated echocardiographic analysis, mean postoperative aortic valve gradient was 7.6±3.3 mm Hg, and 2.8% of patients exhibited paravalvular regurgitation grade ≥2. Conclusions In this report of postmarket use of the ACURATE neo2 valve in a real-world transcatheter aortic valve implantation population, patients exhibited favorable postoperative hemodynamics and clinical outcomes and a low rate of postoperative pacemaker implantation.


Asunto(s)
Lesión Renal Aguda , Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Accidente Cerebrovascular , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Femenino , Anciano de 80 o más Años , Masculino , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Diseño de Prótesis , Resultado del Tratamiento , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Sistema de Registros , Accidente Cerebrovascular/epidemiología
18.
JACC cardiovasc. interv ; (23): (23)00846-4, jul.2023. ilus
Artículo en Inglés | Sec. Est. Saúde SP, CONASS, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1444382

RESUMEN

OBJECTIVES: The authors sought to evaluate the incidence, predictors, and outcomes of new permanent pacemaker implantation (PPI) after transcatheter aortic valve replacement (TAVR) with contemporary self-expanding valves (SEV). BACKGROUND: Need for PPI is frequent post-TAVR, but conflicting data exist on new-generation SEV and on the prognostic impact of PPI. METHODS: This study included 3,211 patients enrolled in the multicenter NEOPRO (A Multicenter Comparison of Acurate NEO Versus Evolut PRO Transcatheter Heart Valves) and NEOPRO-2 (A Multicenter Comparison of ACURATE NEO2 Versus Evolut PRO/PRO+ Transcatheter Heart Valves 2) registries (January 2012 to December 2021) who underwent transfemoral TAVR with SEV. Implanted transcatheter heart valves (THV) were Acurate neo (n = 1,090), Acurate neo2 (n = 665), Evolut PRO (n = 1,312), and Evolut PRO+ (n = 144). Incidence and predictors of new PPI and 1-year outcomes were evaluated. RESULTS: New PPI was needed in 362 patients (11.3%) within 30 days after TAVR (8.8%, 7.7%, 15.2%, and 10.4%, respectively, after Acurate neo, Acurate neo2, Evolut PRO, and Evolut PRO+). Independent predictors of new PPI were Society of Thoracic Surgeons Predicted Risk of Mortality score, baseline right bundle branch block and depth of THV implantation, both in patients treated with Acurate neo/neo2 and in those treated with Evolut PRO/PRO+. Predischarge reduction in ejection fraction (EF) was more frequent in patients requiring PPI (P = 0.014). New PPI was associated with higher 1-year mortality (16.9% vs 10.8%; adjusted HR: 1.66; 95% CI: 1.13-2.43; P = 0.010), particularly in patients with baseline EF <40% (P for interaction = 0.049). CONCLUSIONS: New PPI was frequently needed after TAVR with SEV (11.3%) and was associated with higher 1-year mortality, particularly in patients with EF <40%. Baseline right bundle branch block and depth of THV implantation independently predicted the need of PPI.


Asunto(s)
Marcapaso Artificial
19.
Cell Chem Biol ; 30(6): 573-590.e6, 2023 06 15.
Artículo en Inglés | MEDLINE | ID: mdl-37130519

RESUMEN

The natural product family of the fusicoccanes (FCs) has been shown to display anti-cancer activity, especially when combined with established therapeutic agents. FCs stabilize 14-3-3 protein-protein interactions (PPIs). Here, we tested combinations of a small library of FCs with interferon α (IFNα) on different cancer cell lines and report a proteomics approach to identify the specific 14-3-3 PPIs that are induced by IFNα and stabilized by FCs in OVCAR-3 cells. Among the identified 14-3-3 target proteins are THEMIS2, receptor interacting protein kinase 2 (RIPK2), EIF2AK2, and several members of the LDB1 complex. Biophysical and structural biology studies confirm these 14-3-3 PPIs as physical targets of FC stabilization, and transcriptome as well as pathway analyses suggest possible explanations for the observed synergistic effect of IFNα/FC treatment on cancer cells. This study elucidates the polypharmacological effects of FCs in cancer cells and identifies potential targets from the vast interactome of 14-3-3s for therapeutic intervention in oncology.


Asunto(s)
Interferón-alfa , Neoplasias Ováricas , Humanos , Femenino , Interferón-alfa/farmacología , Apoptosis , Línea Celular Tumoral , Muerte Celular
20.
Biomech Model Mechanobiol ; 22(4): 1395-1410, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-37210464

RESUMEN

Fundamental knowledge about in vivo kinematics and contact conditions at the articulating interfaces of total knee replacements are essential for predicting and optimizing their behavior and durability. However, the prevailing motions and contact stresses in total knee replacements cannot be precisely determined using conventional in vivo measurement methods. In silico modeling, in turn, allows for a prediction of the loads, velocities, deformations, stress, and lubrication conditions across the scales during gait. Within the scope of this paper, we therefore combine musculoskeletal modeling with tribo-contact modeling. In the first step, we compute contact forces and sliding velocities by means of inverse dynamics approach and force-dependent kinematic solver based upon experimental gait data, revealing contact forces during healthy/physiological gait of young subjects. In a second step, the derived data are employed as input data for an elastohydrodynamic model based upon the finite element method full-system approach taking into account elastic deformation, the synovial fluid's hydrodynamics as well as mixed lubrication to predict and discuss the subject-specific pressure and lubrication conditions.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Articulación de la Rodilla , Humanos , Articulación de la Rodilla/fisiología , Modelos Biológicos , Fenómenos Mecánicos , Marcha/fisiología , Fenómenos Biomecánicos , Simulación por Computador
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...