Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
J Thorac Oncol ; 17(4): 519-531, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-34973418

RESUMEN

INTRODUCTION: Electromagnetic navigation bronchoscopy (ENB) is a minimally invasive, image-guided approach to access lung lesions for biopsy or localization for treatment. However, no studies have reported prospective 24-month follow-up from a large, multinational, generalizable cohort. This study evaluated ENB safety, diagnostic yield, and usage patterns in an unrestricted, real-world observational design. METHODS: The NAVIGATE single-arm, pragmatic cohort study (NCT02410837) enrolled subjects at 37 academic and community sites in seven countries with prospective 24-month follow-up. Subjects underwent ENB using the superDimension navigation system versions 6.3 to 7.1. The prespecified primary end point was procedure-related pneumothorax requiring intervention or hospitalization. RESULTS: A total of 1388 subjects were enrolled for lung lesion biopsy (1329; 95.7%), fiducial marker placement (272; 19.6%), dye marking (23; 1.7%), or lymph node biopsy (36; 2.6%). Concurrent endobronchial ultrasound-guided staging occurred in 456 subjects. General anesthesia (78.2% overall, 56.6% Europe, 81.4% United States), radial endobronchial ultrasound (50.6%, 4.0%, 57.4%), fluoroscopy (85.0%, 41.7%, 91.0%), and rapid on-site evaluation use (61.7%, 17.3%, 68.5%) differed between regions. Pneumothorax and bronchopulmonary hemorrhage occurred in 4.7% and 2.7% of subjects, respectively (3.2% [primary end point] and 1.7% requiring intervention or hospitalization). Respiratory failure occurred in 0.6%. The diagnostic yield was 67.8% (range: 61.9%-70.7%; 55.2% Europe, 69.8% United States). Sensitivity for malignancy was 62.6%. Lung cancer clinical stage was I to II in 64.7% (55.3% Europe, 65.8% United States). CONCLUSIONS: Despite a heterogeneous cohort and regional differences in procedural techniques, ENB demonstrates low complications and a 67.8% diagnostic yield while allowing biopsy, staging, fiducial placement, and dye marking in a single procedure.


Asunto(s)
Neoplasias Pulmonares , Neumotórax , Broncoscopía/métodos , Estudios de Cohortes , Fenómenos Electromagnéticos , Humanos , Pulmón/patología , Neoplasias Pulmonares/complicaciones , Neoplasias Pulmonares/diagnóstico , Neoplasias Pulmonares/cirugía , Neumotórax/epidemiología , Neumotórax/etiología , Neumotórax/patología , Estudios Prospectivos , Estados Unidos
2.
J Thorac Oncol ; 14(3): 445-458, 2019 03.
Artículo en Inglés | MEDLINE | ID: mdl-30476574

RESUMEN

INTRODUCTION: Electromagnetic navigation bronchoscopy (ENB) is a minimally invasive technology that guides endoscopic tools to pulmonary lesions. ENB has been evaluated primarily in small, single-center studies; thus, the diagnostic yield in a generalizable setting is unknown. METHODS: NAVIGATE is a prospective, multicenter, cohort study that evaluated ENB using the superDimension navigation system (Medtronic, Minneapolis, Minnesota). In this United States cohort analysis, 1215 consecutive subjects were enrolled at 29 academic and community sites from April 2015 to August 2016. RESULTS: The median lesion size was 20.0 mm. Fluoroscopy was used in 91% of cases (lesions visible in 60%) and radial endobronchial ultrasound in 57%. The median ENB planning time was 5 minutes; the ENB-specific procedure time was 25 minutes. Among 1157 subjects undergoing ENB-guided biopsy, 94% (1092 of 1157) had navigation completed and tissue obtained. Follow-up was completed in 99% of subjects at 1 month and 80% at 12 months. The 12-month diagnostic yield was 73%. Pathology results of the ENB-aided tissue samples showed malignancy in 44% (484 of 1092). Sensitivity, specificity, positive predictive value, and negative predictive value for malignancy were 69%, 100%, 100%, and 56%, respectively. ENB-related Common Terminology Criteria for Adverse Events grade 2 or higher pneumothoraces (requiring admission or chest tube placement) occurred in 2.9%. The ENB-related Common Terminology Criteria for Adverse Events grade 2 or higher bronchopulmonary hemorrhage and grade 4 or higher respiratory failure rates were 1.5% and 0.7%, respectively. CONCLUSIONS: NAVIGATE shows that an ENB-aided diagnosis can be obtained in approximately three-quarters of evaluable patients across a generalizable cohort based on prospective 12-month follow-up in a pragmatic setting with a low procedural complication rate.


Asunto(s)
Broncoscopía/métodos , Enfermedades Pulmonares/diagnóstico , Neumotórax/diagnóstico , Adulto , Anciano , Anciano de 80 o más Años , Fenómenos Electromagnéticos , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Pronóstico , Estudios Prospectivos , Adulto Joven
3.
BMC Pulm Med ; 17(1): 59, 2017 04 11.
Artículo en Inglés | MEDLINE | ID: mdl-28399830

RESUMEN

BACKGROUND: Electromagnetic navigation bronchoscopy (ENB) is an image-guided, minimally invasive approach that uses a flexible catheter to access pulmonary lesions. METHODS: NAVIGATE is a prospective, multicenter study of the superDimension™ navigation system. A prespecified 1-month interim analysis of the first 1,000 primary cohort subjects enrolled at 29 sites in the United States and Europe is described. Enrollment and 24-month follow-up are ongoing. RESULTS: ENB index procedures were conducted for lung lesion biopsy (n = 964), fiducial marker placement (n = 210), pleural dye marking (n = 17), and/or lymph node biopsy (n = 334; primarily endobronchial ultrasound-guided). Lesions were in the peripheral/middle lung thirds in 92.7%, 49.7% were <20 mm, and 48.4% had a bronchus sign. Radial EBUS was used in 54.3% (543/1,000 subjects) and general anesthesia in 79.7% (797/1,000). Among the 964 subjects (1,129 lesions) undergoing lung lesion biopsy, navigation was completed and tissue was obtained in 94.4% (910/964). Based on final pathology results, ENB-aided samples were read as malignant in 417/910 (45.8%) subjects and non-malignant in 372/910 (40.9%) subjects. An additional 121/910 (13.3%) were read as inconclusive. One-month follow-up in this interim analysis is not sufficient to calculate the true negative rate or diagnostic yield. Tissue adequacy for genetic testing was 80.0% (56 of 70 lesions sent for testing). The ENB-related pneumothorax rate was 4.9% (49/1,000) overall and 3.2% (32/1,000) CTCAE Grade ≥2 (primary endpoint). The ENB-related Grade ≥2 bronchopulmonary hemorrhage and Grade ≥4 respiratory failure rates were 1.0 and 0.6%, respectively. CONCLUSIONS: One-month results of the first 1,000 subjects enrolled demonstrate low adverse event rates in a generalizable population across diverse practice settings. Continued enrollment and follow-up are required to calculate the true negative rate and delineate the patient, lesion, and procedural factors contributing to diagnostic yield. TRIAL REGISTRATION: ClinicalTrials.gov NCT02410837 . Registered 31 March 2015.


Asunto(s)
Broncoscopía/métodos , Neoplasias Pulmonares/diagnóstico , Pulmón/patología , Adulto , Anciano , Anciano de 80 o más Años , Diagnóstico Diferencial , Fenómenos Electromagnéticos , Europa (Continente) , Femenino , Humanos , Biopsia Guiada por Imagen/métodos , Ganglios Linfáticos/patología , Masculino , Persona de Mediana Edad , Estadificación de Neoplasias , Neumotórax/epidemiología , Neumotórax/etiología , Estudios Prospectivos , Tomografía Computarizada por Rayos X , Estados Unidos , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...