Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 92
Filtrar
1.
Clin Transl Radiat Oncol ; 43: 100674, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37753462

RESUMEN

We compiled a sampling of the treatment techniques of intensity-modulated total body irradiation, total marrow irradiation and total marrow and lymphoid irradiation utilized by several centers across North America and Europe. This manuscript does not serve as a consensus guideline, but rather is meant to serve as a convenient reference for centers that are considering starting an intensity-modulated program.

3.
Cancer Biother Radiopharm ; 38(1): 26-37, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36154291

RESUMEN

Background: PET imaging using radiolabeled immunoconstructs shows promise in cancer detection and in assessing tumor response to therapies. The authors report the first-in-human pilot study evaluating M5A, a humanized anti-carcinoembryonic antigen (CEA) monoclonal antibody (mAb), radiolabeled with 64Cu in patients with CEA-expressing malignancies. The purpose of this pilot study was to identify the preferred patient population for further evaluation of this agent in an expanded trial. Methods: Patients with CEA-expressing primary or metastatic cancer received 64Cu-DOTA-hT84.66-M5A with imaging performed at 1 and 2 days postinfusion. 64Cu-DOTA-hT84.66-M5A PET scan findings were correlated with CT, MRI, and/or FDG PET scans and with histopathologic findings from planned surgery or biopsy performed postscan. Results: Twenty patients received 64Cu-DOTA-hT84.66-M5A. Twelve patients demonstrated positive images, which were confirmed in 10 patients as tumor by standard-of-care (SOC) imaging, biopsy, or surgical findings. Four of the 8 patients with negative imaging were confirmed as true negative, with the remaining 4 patients having disease demonstrated by SOC imaging or surgery. All 5 patients with locally advanced rectal cancer underwent planned biopsy or surgery after 64Cu-DOTA-hT84.66-M5A imaging (4 patients imaged 6-8 weeks after completing neoadjuvant chemotherapy and radiation therapy) and demonstrated a high concordance between biopsy findings and 64Cu-DOTA-hT84.66-M5A PET scan results. Three patients demonstrated positive uptake at the primary site later confirmed by biopsy and at surgery as residual disease. Two patients with negative scans each demonstrated complete pathologic response. In 5 patients with medullary thyroid cancer, 64Cu-DOTA-hT84.66-M5A identified disease not seen on initial CT scans in 3 patients, later confirmed to be disease by subsequent surgery or MRI. Conclusions: 64Cu-DOTA-hT84.66-M5A demonstrates promise in tumor detection, particularly in patients with locally advanced rectal cancer and medullary thyroid cancer. A successor trial in locally advanced rectal cancer has been initiated to further evaluate this agent's ability to define tumor extent before and assess disease response after neoadjuvant chemotherapy and radiotherapy. clinical trial.gov (NCT02293954).


Asunto(s)
Neoplasias del Recto , Neoplasias de la Tiroides , Humanos , Antígeno Carcinoembrionario , Proyectos Piloto , Anticuerpos Monoclonales/uso terapéutico
4.
Front Oncol ; 12: 1017355, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36387179

RESUMEN

Background: Total Marrow and Lymphoid Irradiation (TMLI) is a promising component of the preparative regimen for hematopoietic cell transplantation in patients with high-risk acute myeloid leukemia (AML) and acute lymphoid leukemia (ALL). Extramedullary (EM) relapse after TMLI is comparable to TBI and non-TBI conditioning regimens. This study evaluates outcomes of patients treated with radiotherapy (RT) with EM relapse previously treated with TMLI. Methods: A retrospective analysis of five prospective TMLI trials was performed. TMLI targeted bones and major lymphoid tissues using image-guided tomotherapy, with total dose ranging from 12 to 20 Gy. EM recurrences were treated at the discretion of the hematologist and radiation oncologist using RT ± chemotherapy. Descriptive statistics and survival analysis were then performed on this cohort. Results: In total, 254 patients with refractory or relapsed AML or ALL were treated with TMLI at our institution. Twenty-one patients were identified as receiving at least one subsequent course of radiation. A total of 67 relapse sites (median=2 sites/patient, range=1-16) were treated. Eleven relapsed patients were initially treated with curative intent. Following the initial course of subsequent RT, 1-year, 3-year and 5-year estimates of OS were 47.6%, 32.7% and 16.3%, respectively. OS was significantly better in patients treated with curative intent, with median OS of 50.7 months vs 1.6 months (p<0.001). 1-year, 3-year and 5-year estimates of PFS were 23.8%, 14.3% and 14.3%, respectively. PFS was significantly better in patients treated with curative intent, with median PFS of 6.6 months vs 1.3 months (p<0.001). Following RT, 86.6% of the sites had durable local control. Conclusions: RT is an effective modality to treat EM relapse in patients with acute leukemia who relapse after HCT achieving high levels of local control. In patients with limited relapse amenable to curative intent, radiation confers favorable long-term survival. Radiation as salvage treatment for EM relapse after HCT warrants further evaluation.

5.
Front Oncol ; 12: 1003908, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36263219

RESUMEN

Purpose: TMI utilizes IMRT to deliver organ sparing targeted radiotherapy in patients undergoing hematopoietic cell transplantation (HCT). TMI addresses an unmet need, specifically patients with refractory or relapsed (R/R) hematologic malignancies who have poor outcomes with standard HCT regimens and where attempts to improve outcomes by adding or dose escalating TBI are not possible due to increased toxicities. Over 500 patients have received TMI at this center. This review summarizes this experience including planning and delivery, clinical results, and future directions. Methods: Patients were treated on prospective allogeneic HCT trials using helical tomographic or VMAT IMRT delivery. Target structures included the bone/marrow only (TMI), or the addition of lymph nodes, and spleen (total marrow and lymphoid irradiation, TMLI). Total dose ranged from 12 to 20 Gy at 1.5-2.0 Gy fractions twice daily. Results: Trials demonstrate engraftment in all patients and a low incidence of radiation related toxicities and extramedullary relapses. In R/R acute leukemia TMLI 20 Gy, etoposide, and cyclophosphamide (Cy) results in a 1-year non-relapse mortality (NRM) rate of 6% and 2-year overall survival (OS) of 48%; TMLI 12 Gy added to fludarabine (flu) and melphalan (mel) in older patients (≥ 60 years old) results in a NRM rate of 33% comparable to flu/mel alone, and 5-year OS of 42%; and TMLI 20 Gy/flu/Cy and post-transplant Cy (PTCy) in haplo-identical HCT results in a 2-year NRM rate of 13% and 1-year OS of 83%. In AML in complete remission, TMLI 20 Gy and PTCy results in 2-year NRM, OS, and GVHD free/relapse-free survival (GRFS) rates of 0%, 86·7%, and 59.3%, respectively. Conclusion: TMI/TMLI shows significant promise, low NRM rates, the ability to offer myeloablative radiation containing regimens to older patients, the ability to dose escalate, and response and survival rates that compare favorably to published results. Collaboration between radiation oncology and hematology is key to successful implementation. TMI/TMLI represents a paradigm shift from TBI towards novel strategies to integrate a safer and more effective target-specific radiation therapy into HCT conditioning beyond what is possible with TBI and will help expand and redefine the role of radiotherapy in HCT.

6.
Front Oncol ; 12: 946725, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35957914

RESUMEN

Purpose/Objectives: The aim of this study is to report historical treatment planning experience at our institution for patients receiving total marrow and lymphatic irradiation (TMLI) as part of the conditioning regimen prior to hematopoietic stem cell transplant. Materials/Methods: Based on a review of all historical clinical TMLI treatments plans, we retrieved a 12-Gy cohort of 108 patients with a prescription dose of 12 Gy to the skeletal bones, lymph nodes, spleen, and spinal canal, and retrieved a 20-Gy cohort of 120 patients with an escalated prescription dose of 20 Gy to the skeletal bones, lymph nodes, spleen, and spinal cord, and 12 Gy to the brain and liver. Representative dosimetric parameters including mean and median dose, D80, and D10 (dose covering 80% and 10% of the structure volume, respectively) for targets and normal organs were extracted and compared between the two groups of patients. Results: For the 12-Gy cohort, the average mean dose for normal organs ranged from 18.3% to 78.3% of 12 Gy, and the average median dose ranged from 18.3% to 77.5% of 12 Gy. For the 20-Gy cohort, the average mean dose for normal organs ranged from 13.0% to 76.0% of 20 Gy, and the average median dose ranged from 12.5% to 75.0% of 20 Gy. Compared to the mean dose to normal organs in the 12-Gy cohort, the average mean dose to normal organs increased from 0.0% to 73.1%, with only four normal organs showing a >50% increase. Normal organ dose in TMLI plans using volumetric modulated arc therapy fields fell within the dose range in historical TMLI plans. Conclusion: Dosimetric data in historical TMLI plans at our institution are summarized at prescription dose levels of 12 Gy and 20 Gy, respectively. Compared to the normal organ dose with a prescription dose of 12 Gy, the mean and median dose to most normal organs at an escalated prescription dose of 20 Gy had an increase less than prescription dose scaling. Dosimetric results from this study can be used as reference data to facilitate clinical implementation of TMLI at other institutions.

7.
Front Oncol ; 12: 941814, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35924145

RESUMEN

Total marrow irradiation (TMI) has significantly improved radiation conditioning for hematopoietic cell transplantation in hematologic diseases by reducing conditioning-induced toxicities and improving survival outcomes in relapsed/refractory patients. Recently, preclinical three-dimensional image-guided TMI has been developed to enhance mechanistic understanding of the role of TMI and to support the development of experimental therapeutics. However, a dosimetric comparison between preclinical and clinical TMI reveals that the preclinical TMI treatment lacks the ability to reduce the dose to some of the vital organs that are very close to the skeletal system and thus limits the ability to evaluate radiobiological relevance. To overcome this limit, we introduce a novel Sparse Orthogonal Collimator (SOC)-based TMI and evaluate its ability to enhance dosimetric conformality. The SOC-TMI-based dose modulation technique significantly improves TMI treatment planning by reducing radiation exposures to critical organs that are close to the skeletal system that leads to reducing the gap between clinical and preclinical TMI.

8.
Blood Adv ; 6(14): 4098-4106, 2022 07 26.
Artículo en Inglés | MEDLINE | ID: mdl-35838754

RESUMEN

Posttransplant cyclophosphamide (PTCy) platform has shown low rates of graft-versus-host disease (GVHD) and nonrelapse mortality (NRM) after haploidentical hematopoietic cell transplantation (HaploHCT). However, because of the limited disease control, relapse rate remains a major cause of treatment failure in high-risk patients. Total marrow and lymphoid irradiation (TMLI) allows for delivery of high radiation to bone marrow and other targeted structures, without increasing off-target radiation exposure and toxicity to end organs. In this phase 1 trial, 31 patients with high-risk and/or active primary refractory leukemias or myelodysplastic syndrome underwent peripheral blood stem cell HaploHCT with TMLI, fludarabine, and cyclophosphamide as the conditioning regimen. Radiation dose was escalated in increments of 200 cGy (1200-2000 cGy). GVHD prophylaxis was PTCy with tacrolimus/mycophenolate mofetil. Grade 2 toxicities by the Bearman scale were mucositis (n = 1), hepatic (n = 3), gastrointestinal (n = 5), and cardiac (n = 2). One patient (1800 cGy) experienced grade 3 pulmonary toxicity (dose-limiting toxicity). At a follow-up duration of 23.9 months for the whole cohort; 2-year NRM was 13%. Cumulative incidence of day 100 grade 2 to 4 and 3 to 4 acute GVHD was 52% and 6%, respectively. Chronic GVHD at 2 years was 35%. For patients treated with 2000 cGy, with a median follow-up duration of 12.3 months, 1-year relapse/progression, progression-free survival, and overall survival rates were 17%, 74%, and 83%, respectively. In conclusion, HaploHCT-TMLI with PTCy was safe and feasible in our high-risk patient population with promising outcomes.


Asunto(s)
Ciclofosfamida , Enfermedad Injerto contra Huésped , Trasplante Haploidéntico , Médula Ósea , Ciclofosfamida/efectos adversos , Enfermedad Injerto contra Huésped/prevención & control , Humanos , Irradiación Linfática , Recurrencia
9.
Lancet Oncol ; 23(7): 910-918, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-35714666

RESUMEN

BACKGROUND: Men with grade group 2 or 3 prostate cancer are often considered ineligible for active surveillance; some patients with grade group 2 prostate cancer who are managed with active surveillance will have early disease progression requiring radical therapy. This study aimed to investigate whether MRI-guided focused ultrasound focal therapy can safely reduce treatment burden for patients with localised grade group 2 or 3 intermediate-risk prostate cancer. METHODS: In this single-arm, multicentre, phase 2b study conducted at eight health-care centres in the USA, we recruited men aged 50 years and older with unilateral, MRI-visible, primary, intermediate-risk, previously untreated prostate adenocarcinoma (prostate-specific antigen ≤20 ng/mL, grade group 2 or 3; tumour classification ≤T2) confirmed on combined biopsy (combining MRI-targeted and systematic biopsies). MRI-guided focused ultrasound energy, sequentially titrated to temperatures sufficient for tissue ablation (about 60-70°C), was delivered to the index lesion and a planned margin of 5 mm or more of normal tissue, using real-time magnetic resonance thermometry for intraoperative monitoring. Co-primary outcomes were oncological outcomes (absence of grade group 2 and higher cancer in the treated area at 6-month and 24-month combined biopsy; when 24-month biopsy data were not available and grade group 2 or higher cancer had occurred in the treated area at 6 months, the 6-month biopsy results were included in the final analysis) and safety (adverse events up to 24 months) in all patients enrolled in the study. This study is registered with ClinicalTrials.gov, NCT01657942, and is no longer recruiting. FINDINGS: Between May 4, 2017, and Dec 21, 2018, we assessed 194 patients for eligibility and treated 101 patients with MRI-guided focused ultrasound. Median age was 63 years (IQR 58-67) and median concentration of prostate-specific antigen was 5·7 ng/mL (IQR 4·2-7·5). Most cancers were grade group 2 (79 [78%] of 101). At 24 months, 78 (88% [95% CI 79-94]) of 89 men had no evidence of grade group 2 or higher prostate cancer in the treated area. No grade 4 or grade 5 treatment-related adverse events were reported, and only one grade 3 adverse event (urinary tract infection) was reported. There were no treatment-related deaths. INTERPRETATION: 24-month biopsy outcomes show that MRI-guided focused ultrasound focal therapy is safe and effectively treats grade group 2 or 3 prostate cancer. These results support focal therapy for select patients and its use in comparative trials to determine if a tissue-preserving approach is effective in delaying or eliminating the need for radical whole-gland treatment in the long term. FUNDING: Insightec and the National Cancer Institute.


Asunto(s)
Antígeno Prostático Específico , Neoplasias de la Próstata , Anciano , Humanos , Imagen por Resonancia Magnética/métodos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Próstata/patología , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/patología , Neoplasias de la Próstata/terapia
10.
J Appl Clin Med Phys ; 23(6): e13613, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-35441441

RESUMEN

PURPOSE/OBJECTIVES: The aim of this study is to compare intrafractional motion using two commercial non-invasive immobilization systems for linac-based intracranial stereotactic radiosurgery (SRS) under guidance with a surface-guided radiotherapy (SGRT) system. MATERIALS/METHODS: Twenty-one patients who received intracranial SRS were retrospectively selected. Ten patients were immobilized with a vacuum fixation biteplate system, while 11 patients were immobilized with an open-face mask system. A setup margin of 1 mm was used in treatment planning. Real-time surface motion data in 37 treatment fractions using the vacuum fixation system and 44 fractions using the open-face mask were recorded by an SGRT system. Variances of intrafractional motion along three translational directions and three rotational directions were compared between the two immobilization techniques with Levene's tests. Intrafractional motion variation over time during treatments was also evaluated. RESULTS: Using the vacuum fixation system, the average and standard deviations of the shifts were 0.01 ± 0.18 mm, -0.06 ± 0.30 mm, and  0.02 ± 0.26 mm in the anterior-posterior (AP), superior-inferior (SI), and left-right (LR) directions, and -0.02 ± 0.19°, -0.01 ± 0.13°, and 0.01 ± 0.13° for rotations in yaw, roll, and pitch, respectively; using the open-face mask system, the average and standard deviations of the shifts were -0.06 ± 0.20 mm, -0.02 ± 0.35 mm, and 0.01 ± 0.40 mm in the AP, SI, and LR directions, and were 0.05 ± 0.23°, 0.02 ± 0.21°, and 0.00 ± 0.16° for rotations in yaw, roll, and pitch, respectively. There was a significant increase in intrafractional motion variance over time during treatments. CONCLUSION: Patients with the vacuum fixation system had significantly smaller intrafractional motion variation compared to those with the open-face mask system. Using intrafractional motion techniques such as surface imaging system is recommended to minimize dose deviation due to intrafractional motion. The increase in intrafractional motion over time indicates clinical benefits with shorter treatment time.


Asunto(s)
Radiocirugia , Humanos , Inmovilización/métodos , Posicionamiento del Paciente , Radiocirugia/métodos , Planificación de la Radioterapia Asistida por Computador/métodos , Estudios Retrospectivos
11.
Front Oncol ; 12: 1042652, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36686805

RESUMEN

Background: The aim of this study is to report historical treatment planning experience at our institution for patients receiving total marrow and lymphatic irradiation (TMLI) using volumetric modulated arc therapy (VMAT) as part of the conditioning regimen prior to hematopoietic stem cell transplant. Methods: We identified a total of fifteen patients with VMAT TMLI, ten with a prescription dose of 20 Gy (targeting the skeletal bones, lymph nodes, spleen, and spinal canal, with 12 Gy to the brain and liver) and five with a prescription dose of 12-16 Gy (targeting the skeletal bones, lymph nodes, spleen, and spinal canal). Representative dosimetric parameters including total treatment time, mean and median dose, D80, and D10 (dose covering 80% and 10% of the structure volume, respectively) for targets and normal organs were extracted and compared to historical patients treated with helical tomotherapy. Results: The median treatment time for the first and subsequent fractions was 1.5 and 1.1 hours, respectively. All the target volumes had a mean dose greater than the prescribed dose except the ribs, which had an average mean dose of 19.5 Gy. The skeletal bones had an average mean dose of 21.1 Gy. The brain and liver have average mean doses of 14.8 and 14.1 Gy, respectively. The mean lung dose had an average of 7.6 ± 0.6 Gy for the 20-Gy cohort. Relative to the prescription dose of 20 Gy, the average mean dose for the normal organ volumes ranged from 16.5% to 72.0%, and the average median dose for the normal organs ranged from 16.5% to 71.0%. Dosimetry for patients treated to 12-16 Gy fell within expected ranges based on historical helical tomotherapy plans. Conclusions: Dosimetric data in the VMAT TMLI plans at our institution are summarized for 20 Gy and 12-16 Gy cohorts. Dose distributions and treatment times are overall similar to plans generated with helical tomotherapy. TMLI may be delivered effectively using a VMAT technique, even at escalated doses.

12.
Front Pediatr ; 9: 774348, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34926349

RESUMEN

Total body irradiation (TBI) has been a pivotal component of the conditioning regimen for allogeneic myeloablative haematopoietic stem cell transplantation (HSCT) in very-high-risk acute lymphoblastic leukaemia (ALL) for decades, especially in children and young adults. The myeloablative conditioning regimen has two aims: (1) to eradicate leukaemic cells, and (2) to prevent rejection of the graft through suppression of the recipient's immune system. Radiotherapy has the advantage of achieving an adequate dose effect in sanctuary sites and in areas with poor blood supply. However, radiotherapy is subject to radiobiological trade-offs between ALL cell destruction, immune and haematopoietic stem cell survival, and various adverse effects in normal tissue. To diminish toxicity, a shift from single-fraction to fractionated TBI has taken place. However, HSCT and TBI are still associated with multiple late sequelae, leaving room for improvement. This review discusses the past developments of TBI and considerations for dose, fractionation and dose-rate, as well as issues regarding TBI setup performance, limitations and possibilities for improvement. TBI is typically delivered using conventional irradiation techniques and centres have locally developed heterogeneous treatment methods and ways to achieve reduced doses in several organs. There are, however, limitations in options to shield organs at risk without compromising the anti-leukaemic and immunosuppressive effects of conventional TBI. Technological improvements in radiotherapy planning and delivery with highly conformal TBI or total marrow irradiation (TMI), and total marrow and lymphoid irradiation (TMLI) have opened the way to investigate the potential reduction of radiotherapy-related toxicities without jeopardising efficacy. The demonstration of the superiority of TBI compared with chemotherapy-only conditioning regimens for event-free and overall survival in the randomised For Omitting Radiation Under Majority age (FORUM) trial in children with high-risk ALL makes exploration of the optimal use of TBI delivery mandatory. Standardisation and comprehensive reporting of conventional TBI techniques as well as cooperation between radiotherapy centres may help to increase the ratio between treatment outcomes and toxicity, and future studies must determine potential added benefit of innovative conformal techniques to ultimately improve quality of life for paediatric ALL patients receiving TBI-conditioned HSCT.

13.
Cancers (Basel) ; 13(20)2021 Oct 15.
Artículo en Inglés | MEDLINE | ID: mdl-34680320

RESUMEN

Targeted radionuclide therapy (TRT) has recently seen a surge in popularity with the use of radionuclides conjugated to small molecules and antibodies. Similarly, immunotherapy also has shown promising results, an example being chimeric antigen receptor T cell (CAR-T) therapy in hematologic malignancies. Moreover, TRT and CAR-T therapies possess unique features that require special consideration when determining how to dose as well as the timing and sequence of combination treatments including the distribution of the TRT dose in the body, the decay rate of the radionuclide, and the proliferation and persistence of the CAR-T cells. These characteristics complicate the additive or synergistic effects of combination therapies and warrant a mathematical treatment that includes these dynamics in relation to the proliferation and clearance rates of the target tumor cells. Here, we combine two previously published mathematical models to explore the effects of dose, timing, and sequencing of TRT and CAR-T cell-based therapies in a multiple myeloma setting. We find that, for a fixed TRT and CAR-T cell dose, the tumor proliferation rate is the most important parameter in determining the best timing of TRT and CAR-T therapies.

14.
Int J Radiat Oncol Biol Phys ; 111(3): 671-683, 2021 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-34119592

RESUMEN

PURPOSE: Total marrow irradiation (TMI) has significantly advanced radiation conditioning for hematopoietic cell transplantation in hematologic malignancies by reducing conditioning-induced toxicities and improving survival outcomes in relapsed/refractory patients. However, the relapse rate remains high, and the lack of a preclinical TMI model has hindered scientific advancements. To accelerate TMI translation to the clinic, we developed a TMI delivery system in preclinical models. METHODS AND MATERIALS: A Precision X-RAD SmART irradiator was used for TMI model development. Images acquired with whole-body contrast-enhanced computed tomography (CT) were used to reconstruct and delineate targets and vital organs for each mouse. Multiple beam and CT-guided Monte Carlo-based plans were performed to optimize doses to the targets and to vary doses to the vital organs. Long-term engraftment and reconstitution potential were evaluated by a congenic bone marrow transplantation (BMT) model and serial secondary BMT, respectively. Donor cell engraftment was measured using noninvasive bioluminescence imaging and flow cytometry. RESULTS: Multimodal imaging enabled identification of targets (skeleton and spleen) and vital organs (eg, lungs, gut, liver). In contrast to total body irradiation (TBI), TMI treatment allowed variation of radiation dose exposure to organs relative to the target dose. Dose reduction mirrored that in clinical TMI studies. Similar to TBI, mice treated with different TMI regimens showed full long-term donor engraftment in primary BMT and second serial BMT. The TBI-treated mice showed acute gut damage, which was minimized in mice treated with TMI. CONCLUSIONS: A novel multimodal image guided preclinical TMI model is reported here. TMI conditioning maintained long-term engraftment with reconstitution potential and reduced organ damage. Therefore, this TMI model provides a unique opportunity to study the therapeutic benefit of reduced organ damage and BM dose escalation to optimize treatment regimens in BMT and hematologic malignancies.


Asunto(s)
Trasplante de Médula Ósea , Neoplasias Hematológicas , Animales , Médula Ósea/diagnóstico por imagen , Humanos , Ratones , Recurrencia Local de Neoplasia , Acondicionamiento Pretrasplante , Irradiación Corporal Total
15.
Clin Cancer Res ; 27(13): 3674-3682, 2021 07 01.
Artículo en Inglés | MEDLINE | ID: mdl-33622706

RESUMEN

PURPOSE: Current FDA-approved imaging modalities are inadequate for localizing prostate cancer biochemical recurrence (BCR). 18F-DCFPyL is a highly selective, small-molecule prostate-specific membrane antigen-targeted PET radiotracer. CONDOR was a prospective study designed to determine the performance of 18F-DCFPyL-PET/CT in patients with BCR and uninformative standard imaging. EXPERIMENTAL DESIGN: Men with rising PSA ≥0.2 ng/mL after prostatectomy or ≥2 ng/mL above nadir after radiotherapy were eligible. The primary endpoint was correct localization rate (CLR), defined as positive predictive value with an additional requirement of anatomic lesion colocalization between 18F-DCFPyL-PET/CT and a composite standard of truth (SOT). The SOT consisted of, in descending priority (i) histopathology, (ii) subsequent correlative imaging findings, or (iii) post-radiation PSA response. The trial was considered a success if the lower bound of the 95% confidence interval (CI) for CLR exceeded 20% for two of three 18F-DCFPyL-PET/CT readers. Secondary endpoints included change in intended management and safety. RESULTS: A total of 208 men with a median baseline PSA of 0.8 ng/mL (range: 0.2-98.4 ng/mL) underwent 18F-DCFPyL-PET/CT. The CLR was 84.8%-87.0% (lower bound of 95% CI: 77.8-80.4). A total of 63.9% of evaluable patients had a change in intended management after 18F-DCFPyL-PET/CT. The disease detection rate was 59% to 66% (at least one lesion detected per patient by 18F-DCFPyL-PET/CT by central readers). CONCLUSIONS: Performance of 18F-DCFPyL-PET/CT achieved the study's primary endpoint, demonstrating disease localization in the setting of negative standard imaging and providing clinically meaningful and actionable information. These data further support the utility of 18F-DCFPyL-PET/CT to localize disease in men with recurrent prostate cancer.See related commentary by True and Chen, p. 3512.


Asunto(s)
Lisina/análogos & derivados , Recurrencia Local de Neoplasia/diagnóstico por imagen , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Neoplasias de la Próstata/diagnóstico por imagen , Urea/análogos & derivados , Adulto , Anciano , Anciano de 80 o más Años , Humanos , Masculino , Persona de Mediana Edad , Recurrencia Local de Neoplasia/sangre , Estudios Prospectivos , Antígeno Prostático Específico/sangre , Neoplasias de la Próstata/sangre
16.
Med Dosim ; 46(2): 171-178, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33272744

RESUMEN

We aimed to compare prototype treatment plans for a new biology-guided radiotherapy (BgRT) machine in its intensity-modulated radiation therapy (IMRT) mode with those using existing IMRT delivery techniques in treatment of nasopharyngeal carcinoma (NPC). We retrospectively selected ten previous NPC patients treated in 33 fractions according to the NRG-HN001 treatment protocol. Three treatment plans were generated for each patient: a helical tomotherapy (HT) plan with a 2.5-cm jaw, a volumetric modulated arc therapy (VMAT) plan using 2 to 4 6-MV arc fields, and a prototype IMRT plan for a new BgRT system which uses a 6-MV photon beam on a ring gantry that rotates at 60 rotations per minute with a couch that moves in small incremental steps. Treatment plans were compared using dosimetric parameters to planning target volumes (PTVs) and organs at risk (OARs) as specified by the NRG-HN001 protocol. Plans for the three modalities had comparable dose coverage, mean dose, and dose heterogeneity to the primary PTV, while the prototype IMRT plans had greater dose heterogeneity to the non-primary PTVs, with the average homogeneity index ranging from 1.28 to 1.50 in the prototype plans. Six of all the 7 OAR mean dose parameters were lower with statistical significance in the prototype plans compared to the HT and VMAT plans with the other mean dose parameter being comparable, and all the 18 OAR maximum dose parameters were comparable or lower with statistical significance in the prototype plans. The average left and right parotid mean doses in the prototype plans were 10.5 Gy and 10.4 Gy lower than those in the HT plans, respectively, and were 5.1 Gy and 5.2 Gy lower than those in the VMAT plans, respectively. Compared to that with the HT and VMAT plans, the treatment time was longer with statistical significance with the prototype IMRT plans. Based on dosimetric comparison of ten NPC cases, the prototype IMRT plans achieved comparable or better critical organ sparing compared to the HT and VMAT plans for definitive NPC radiotherapy. However, there was higher dose heterogeneity to non-primary targets and longer estimated treatment time with the prototype plans.


Asunto(s)
Neoplasias Nasofaríngeas , Radioterapia de Intensidad Modulada , Biología , Humanos , Carcinoma Nasofaríngeo/radioterapia , Neoplasias Nasofaríngeas/radioterapia , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador , Estudios Retrospectivos
17.
J Nucl Med ; 62(1): 55-61, 2021 01.
Artículo en Inglés | MEDLINE | ID: mdl-32620701

RESUMEN

Radioimmunotherapy, an approach using radiolabeled antibodies, has had minimal success in the clinic with several ß-emitting radionuclides for the treatment of ovarian cancer. Alternatively, radioimmunotherapy with α-emitters offers the advantage of depositing much higher energy over shorter distances but was thought to be inappropriate for the treatment of solid tumors, for which antibody penetration is limited to a few cell diameters around the vascular system. However, the deposition of high-energy α-emitters to tumor markers adjacent to a typical leaky tumor vascular system may have large antitumor effects at the tumor vascular level, and their reduced penetration in normal tissue would be expected to lower off-target toxicity. Methods: To evaluate this concept, DOTAylated-huCC49 was labeled with the α-emitter 225Ac to target tumor-associated glycoprotein 72-positive xenografts in a murine model of ovarian cancer. Results:225Ac-labeled DOTAylated-huCC49 radioimmunotherapy significantly reduced tumor growth in a dose-dependent manner (1.85, 3.7, and 7.4 kBq), with the 7.4-kBq dose extending survival by more than 3-fold compared with the untreated control. Additionally, a multitreatment regime (1.85 kBq followed by 5 weekly doses of 0.70 kBq for a total of 5.4 kBq) extended survival almost 3-fold compared with the untreated control group, without significant off-target toxicity. Conclusion: These results establish the potential for antibody-targeted α-radionuclide therapy for ovarian cancer, which may be generalized to α-radioimmunotherapy in other solid tumors.


Asunto(s)
Actinio/uso terapéutico , Partículas alfa/uso terapéutico , Anticuerpos Monoclonales/inmunología , Antígenos de Neoplasias/metabolismo , Compuestos Heterocíclicos con 1 Anillo/química , Neoplasias Ováricas/radioterapia , Radioinmunoterapia/métodos , Animales , Anticuerpos Monoclonales/química , Anticuerpos Monoclonales/farmacocinética , Línea Celular Tumoral , Transformación Celular Neoplásica , Femenino , Humanos , Marcaje Isotópico , Ratones , Terapia Molecular Dirigida , Neoplasias Ováricas/inmunología , Neoplasias Ováricas/metabolismo , Neoplasias Ováricas/patología , Distribución Tisular
19.
Lancet Oncol ; 21(10): e477-e487, 2020 10.
Artículo en Inglés | MEDLINE | ID: mdl-33002443

RESUMEN

The use of total body irradiation as part of conditioning regimens for acute leukaemia is progressively declining because of concerns of late toxic effects and the introduction of radiation-free regimens. Total marrow irradiation and total marrow and lymphoid irradiation represent more targeted forms of radiotherapy compared with total body irradiation that have the potential to decrease toxicity and escalate the dose to the bone marrow for high-risk patients. We review the technological basis and the clinical development of total marrow irradiation and total marrow and lymphoid irradiation, highlighting both the possible advantages as well as the current roadblocks for widespread implementation among transplantation units. The exact role of total marrow irradiation or total marrow and lymphoid irradiation in new conditioning regimens seems dependent on its technological implementation, aiming to make the whole procedure less time consuming, more streamlined, and easier to integrate into the clinical workflow. We also foresee a role for computer-assisted planning, as a way to improve planning and delivery and to incorporate total marrow irradiation and total marrow and lymphoid irradiation in multi-centric phase 2-3 trials.


Asunto(s)
Trasplante de Médula Ósea , Médula Ósea/efectos de la radiación , Leucemia Mieloide Aguda/terapia , Irradiación Linfática , Acondicionamiento Pretrasplante , Humanos , Irradiación Linfática/efectos adversos , Dosis de Radiación , Planificación de la Radioterapia Asistida por Computador , Acondicionamiento Pretrasplante/efectos adversos , Acondicionamiento Pretrasplante/tendencias , Resultado del Tratamiento , Irradiación Corporal Total/efectos adversos
20.
Pract Radiat Oncol ; 10(5): e406-e414, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32302694

RESUMEN

PURPOSE: We aimed to predict and compare radiation-induced, organ-specific, secondary solid-tumor occurrence risks from conventional total body irradiation (TBI) and total marrow irradiation (TMI) for patients undergoing hematopoietic cell transplant. METHODS AND MATERIALS: We retrospectively selected 20 patients who received TMI treatments before hematopoietic cell transplant. Ten patients (5 men; 5 women) received 12 Gy to the skeletal bones, lymph nodes, and spleen, and the other 10 patients (5 men; 5 women) received an escalated dose of 20 Gy to the same targets and 12 Gy to the brain and liver. A conventional TBI treatment plan was generated for each patient with a prescription dose of 12 Gy, using anterior-posterior and posterior-anterior photon beams with lung shielding and a chest wall boost with electron beams. Secondary cancer risks were estimated using linear-exponential and plateau models for major organs. RESULTS: At the 12 Gy dose level, using the linear-exponential model, the total radiation-induced secondary solid-tumor risks for major organs were 159.3 ± 8.7 for men and 221.5 ± 14.4 for women per 10,000 people per year with the TMI plans, which is a reduction of 38.8% and 32.9%, respectively, compared with those with the TBI plans. At the 20 Gy dose level, the risks were 220.3 ± 8.3 for men and 298.5 ± 9.3 for women with the TMI plans, which is a reduction of 14.6% and 9.2%, respectively, compared with those with the 12 Gy TBI plans. Significant risk reductions were also found with the TMI plans using the plateau risk model. CONCLUSIONS: At both the 12 Gy and 20 Gy prescription dose levels, a conditioning regimen using TMI could significantly lower overall radiation-induced secondary solid-tumor risks for major organs compared with a conditioning regimen with standard 12 Gy TBI. Clinical data from long-term follow-up studies are needed to verify the model predictions.


Asunto(s)
Trasplante de Células Madre Hematopoyéticas , Irradiación Corporal Total , Médula Ósea , Femenino , Humanos , Masculino , Dosificación Radioterapéutica , Estudios Retrospectivos , Acondicionamiento Pretrasplante , Irradiación Corporal Total/efectos adversos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...